SUBMERSIBLE TURBINE PUMP I/C Series 7 Inch Or Larger Diameter Wells
Webtrol’s I/C (Irrigation/Commercial) Series Submersible Turbines are designed to withstand the rigorous demands generated through use in irrigation / industrial / commercial use. These pumps are hand built by journeyman to exacting standards and inspected throughout the assembly process as part of Webtrol’s commitment to quality. The design of the Webtrol I/C Series Submersible Turbine is virtually maintenance free in comparison to a lineshaft style turbine pump. Ease of installation, dependability, performance and efficiency are just a few more of the reasons you should look at the Webtrol I/C series Submersible Turbine. We know your time is valuable so Webtrol puts more time into the building of our pumps so you won’t have to spend more time pulling it. Features And Benefits • Heavy wall close grain iron castings • Brass impellers precision balanced • Cutlass rubber bowl bearings • Heavy duty stainless steel shaft • Built in up-thrust protection • Stainless steel pump intake screen and hardware... Specifications Webtrol I/C Series Submersible Turbine Pumps are available from 30 to 1750 Gallons Per Minute. Models, 5 Hp - 200 Hp.
Effective Date: 4/08 Prices are subject to change without notice, catalog updated monthly.
63
I/C SUBMERSIBLE TURBINE PUMP Construction And Design Features
64
1
Discharge One piece steel discharge
2
Pump Bowls Heavy wall close grain iron castings.
3
Pump Bowl Bearings Each bowl is fitted with a extra long, cutlass rubber sleeve bearing.
4
Impellers Balanced brass impellers secured to the pump shaft with precision machined locking collars.
5
Pump Shaft Heavy duty stainless steel pump shaft with stainless steel coupling.
6
Up-Thrust Bearing Built in up-thrust protection is provided by use of a large diameter brass bearing that engages a precision machined surface located inside the motor bracket, unlike most pumps that simply allow the pump shaft to rise up until it rubs against a screw located in the discharge.
7
Wire Cover Heavy gauge stainless steel wire cover.
8
Franklin Electric Motor Water lubricated motor, hermetically sealed windings in a stainless steel enclosure.
9
Quality Construction Webtrol only uses quality components, precision machined and carefully constructed by people who care. Every complete pump is thoroughly tested for flow, pressure and motor load.
Effective Date: 4/08 Prices are subject to change without notice, catalog updated monthly.
I/C SUBMERSIBLE TURBINE PUMP 75-150 GPM, 3450 RPM, 60 Cycle - Performance Curve 20
1102T25011L1 1102T25010L1
700
10
110 Series
1102T2009L1
0
NPSHR - (feet)
800
1102T2008L1
600
Total Dynamic Head (feet)
1102T1507L1 500 1102T1506L1
400
1102T1005L1
1102T1004L1 300
1102T753L1 200 1102T502L1
100
Operating Range
0
0
25
50
75
100
125
150
Flow (gallons per minute) Note: For well of 7” or larger diameter. Caution: Do not use pump at flow rates outside of operating range. To do so can cause premature pump failure. These curves are based on factory tests when pumping clear, fresh, non-aerated water at a temperature not exceeding 85°F and under suction conditions as indicated. Due to production tolerances, these curves can vary plus or minus five percent.
Effective Date: 4/08 Prices are subject to change without notice, catalog updated monthly.
65
I/C SUBMERSIBLE TURBINE PUMP 110 Series Pump & Component Specifications Complete Pump SERIES WIRE
110
3
HP
Motor
MTR. STGS DISCH. LENGTH PH VOLTS DIA.
MODEL NO.
WT (LBS.)
MODEL NO.
Control Box WT (LBS.)
MODEL NO.
5
2
4.0”
51.31”
1
230
6”
1102T502L1
184
10S250-6M
110
31S250-M
5
2
4.0”
48.81”
3
230
6”
1102T502L1-3PH
175
10S250-6M3PH
101
SEE NOTE 3
7.5
3
4.0”
59.93”
1
230
6”
1102T753L1
215
10S275-6M
123
31S275-M
7.5
3
4.0”
56.13”
3
230
6”
1102T753L1-3PH
200
10S275-6M3PH
108
SEE NOTE 3
10
4
4.0”
68.76”
1
230
6”
1102T1004L1
252
10S2100-6M
141
31S2100-M
Pump End
WT (LBS.)
MODEL NO.
WT (LBS.)
8
110T2L1LM
74
110T2L1LM
74
13.5 110T3L1LM
92
110T3L1LM
92
14.6 110T4L1LM
111
10
4
4.0”
63.56”
3
230
6”
1102T1004L1-3PH
227
10S2100-6M3PH
116
SEE NOTE 3
10
5
4.0”
73.58”
1
230
6”
1102T1005L1
270
10S2100-6M
141
31S2100-M
110T4L1LM
111
14.6 110T5L1LM
129
10
5
4.0”
68.38”
3
230
6”
1102T1005L1-3PH
245
10S2100-6M3PH
116
SEE NOTE 3
110T5L1LM
129
15
6
4.0”
81.68”
1
230
6”
1102T1506L1
302
10S2150-M
154
31S2150-DM
15
6
4.0”
75.88”
3
230
6”
1102T1506L1-3PH
277
10S2150-M3PH
129
SEE NOTE 3
110T6L1LM
148
15
7
4.0”
86.43”
1
230
6”
1102T1507L1
320
10S2150-M
154
31S2150-DM
15
7
4.0”
80.63”
3
230
6”
1102T1507L1-3PH
295
10S2150-M3PH
129
20
8
4.0”
82.81”
3
230
6”
1102T2008L1-3PH
330
10S2200-M3PH
145
20
9
4.0”
87.63”
3
230
6”
1102T2009L1-3PH
348
10S2200-M3PH
145
25
10
4.0”
95.13”
3
230
6”
1102T25010L1-3PH 378
10S2250-M3PH
156
SEE NOTE 3
110T10L1LM 222
25
11
4.0”
99.88”
3
230
6”
1102T25011L1-3PH 396
10S2250-M3PH
156
SEE NOTE 3
110T11L1LM
18
110T6L1LM
148
110T7L1LM
166
SEE NOTE 3
110T7L1LM
166
SEE NOTE 3
110T8L1LM
185
SEE NOTE 3
110T9L1LM
203
18
240
Note: 1). For 7” diameter wells or larger. 2). Motor controls used on 3 phase units must be equipped with quick trip (10 seconds maximum) heaters on each leg or warranty is void. 3). Solid state starters sold separately. See motors and controls section. 4). 50 cycle and 316 stainless steel motors are available upon request.
Complete Pump Numbering System Model Number: Nominal Rated Flow (GPM)
( )
2 = 230V 8 = 208V Voltage 3 = 380V 4 = 460V 5 = 575V Turbine Divide By 10 For Rated Motor HP (Example: 400 : 10 = 40 HP)
66
Pump Head Only - Numbering System
1102T502L1-3PH Model Number: Motor Type: SP = 2 Wire Blank = 3 Wire 3 PH = 3 Phase
110T2L1LM
Nominal Rated Flow (GPM)
LM = Less Motor
Turbine
Impeller Trim
Impeller Trim Number of Stages
Effective Date: 4/08 Prices are subject to change without notice, catalog updated monthly.
Number of Stages
I/C SUBMERSIBLE TURBINE PUMP 120-200 GPM, 3450 RPM, 60 Cycle - Performance Curve 30 20 1402T3009M1
140 Series
700
10
NPSHR - (feet)
800
0
1402T3008M1 600
Total Dynamic Head (feet)
1402T2507M1
500
1402T2006M1
1402T2005M1
400
1402T1504M1 300 1402T1003M1 200 1402T752M1
100
1402T501M1
Operating Range
0
0
50
100
150
200
250
300
Flow (gallons per minute) Note: For well of 7” or larger diameter. Caution: Do not use pump at flow rates outside of operating range. To do so can cause premature pump failure. These curves are based on factory tests when pumping clear, fresh, non-aerated water at a temperature not exceeding 85°F and under suction conditions as indicated. Due to production tolerances, these curves can vary plus or minus five percent.
Effective Date: 4/08 Prices are subject to change without notice, catalog updated monthly.
67
I/C SUBMERSIBLE TURBINE PUMP 140 Series Pump & Component Specifications Complete Pump SERIES WIRE
140
3
HP
Motor
MTR. STGS DISCH. LENGTH PH VOLTS DIA.
MODEL NO.
WT (LBS.)
MODEL NO.
Control Box WT (LBS.)
MODEL NO.
5
1
4.0”
46.50”
1
230
6”
1402T501M1
166
10S250-6M
110
31S250-M
5
1
4.0”
44.00”
3
230
6”
1402T501M1-3PH
157
10S250-6M3PH
101
SEE NOTE 3
7.5
2
4.0”
55.11”
1
230
6”
1402T752M1
198
10S275-6M
123
31S275-M
7.5
2
4.0”
51.31”
3
230
6”
1402T752M1-3PH
183
10S275-6M3PH
108
SEE NOTE 3
10
3
4.0”
63.95”
1
230
6”
1402T1003M1
235
10S2100-6M
141
31S2100-M
10
3
4.0”
58.75”
3
230
6”
1402T1003M1-3PH 210
10S2100-6M3PH
116
SEE NOTE 3
15
4
4.0”
71.99”
1
230
6”
1402T1504M1
10S2150-M
154
31S2150-DM
15
4
4.0”
66.19”
3
230
6”
1402T1504M1-3PH 243
10S2150-M3PH
129
20
5
4.0”
68.38”
3
230
6”
1402T2005M1-3PH 277
10S2200-M3PH
20
6
4.0”
73.25”
3
230
6”
1402T2006M1-3PH 296
10S2200-M3PH
25
7
4.0”
80.63”
3
230
6”
1402T2507M1-3PH 326
30
8
4.0”
87.94”
3
230
6”
30
9
4.0”
92.75”
3
230
6”
Pump End
WT (LBS.)
MODEL NO.
WT (LBS.)
8
140T1M1LM
56
140T1M1LM
56
140T2M1LM
75
13.5
140T2M1LM
75
14.6
140T3M1LM
94
140T3M1LM
94
18
140T4M1LM
113
SEE NOTE 3
140T4M1LM
113
145
SEE NOTE 3
140T5M1LM 132
145
SEE NOTE 3
140T6M1LM 151
10S2250-M3PH
156
SEE NOTE 3
140T7M1LM 170
1402T3008M1-3PH 363
10S2300-M3PH
174
SEE NOTE 3
140T8M1LM 189
1402T3009M1-3PH 382
10S2300-M3PH
174
SEE NOTE 3
140T9M1LM 208
267
Note: 1). For 7” diameter wells or larger. 2). Motor controls used on 3 phase units must be equipped with quick trip (10 seconds maximum) heaters on each leg or warranty is void. 3). Solid state starters sold separately. See motors and controls section. 4). For 460 volt pumps or motor, change the fourth digit to a 4 (Ex: 1404T501M1-3PH) (Ex:10S450-6M3PH) (460V not available in 1PH). 5). 50 cycle and 316 stainless steel motors are available upon request.
Complete Pump Numbering System Model Number: Nominal Rated Flow (GPM)
( )
2 = 230V 8 = 208V Voltage 3 = 380V 4 = 460V 5 = 575V Turbine Divide By 10 For Rated Motor HP (Example: 400 : 10 = 40 HP)
68
Pump Head Only - Numbering System
1402T1003M1-3PH Model Number: Motor Type: SP = 2 Wire Blank = 3 Wire 3 PH = 3 Phase
140T3M1LM
Nominal Rated Flow (GPM)
LM = Less Motor
Turbine
Impeller Trim
Impeller Trim Number of Stages
Effective Date: 4/08 Prices are subject to change without notice, catalog updated monthly.
Number of Stages
I/C SUBMERSIBLE TURBINE PUMP 180-280 GPM, 3450 RPM, 60 Cycle - Performance Curve 30 20 2004T5009H2
200 Series
700
10
NPSHR - (feet)
800
0
2004T4008H2 600
Total Dynamic Head (feet)
2004T4007H2
500
2002T3006H2
2002T2505H2
400
2002T2004H2 300 2002T1503H2 200 2002T1002H2
100
2002T501H2
Operating Range
0
0
50
100
150
200
250
300
Flow (gallons per minute) Note: For well of 7” or larger diameter. Caution: Do not use pump at flow rates outside of operating range. To do so can cause premature pump failure. These curves are based on factory tests when pumping clear, fresh, non-aerated water at a temperature not exceeding 85°F and under suction conditions as indicated. Due to production tolerances, these curves can vary plus or minus five percent.
Effective Date: 4/08 Prices are subject to change without notice, catalog updated monthly.
69
I/C SUBMERSIBLE TURBINE PUMP 200 Series Pump & Component Specifications Complete Pump SERIES WIRE
200
3
HP
STGS DISCH. LENGTH PH VOLTS
Motor MTR. DIA.
MODEL NO.
WT (LBS.)
MODEL NO.
Control Box WT (LBS.)
MODEL NO.
5
1
4.0”
46.50”
1
230
6”
2002T501H2
165
10S250-6M
110
31S250-M
5
1
4.0”
44.00”
3
230
6”
2002T501H2-3PH
156
10S250-6M3PH
101
SEE NOTE 3
10
2
4.0”
59.13”
1
230
6”
2002T1002H2
215
10S2100-6M
141
31S2100-M
10
2
4.0”
53.94”
3
230
6”
2002T1002H2-3PH
190
10S2100-6M3PH
116
SEE NOTE 3
15
3
4.0”
67.18”
1
230
6”
2002T1503H2
247
10S2150-M
154
31S2150-DM
15
3
4.0”
61.38”
3
230
6”
2002T1503H2-3PH
222
10S2150-M3PH
129
20
4
4.0”
63.56”
3
230
6”
2002T2004H2-3PH
257
10S2200-M3PH
25
5
4.0”
71.00”
3
230
6”
2002T2505H2-3PH
287
10S2250-M3PH
30
6
4.0”
78.38”
3
230
6”
2002T3006H2-3PH
324
40
7
4.0”
88.25”
3
460
6”
2004T4007H2-3PH
40
8
4.0”
93.06”
3
460
6”
2004T4008H2-3PH
50
9
4.0”
114.88”
3
460
6”
2004T5009H2-3PH
Pump End
WT (LBS.)
MODEL NO.
WT (LBS.)
8
200T1H2LM
55
200T1H2LM
55
14.6 200T2H2LM
74
200T2H2LM
74
200T3H2LM
93
SEE NOTE 3
200T3H2LM
93
145
SEE NOTE 3
200T4H2LM
112
156
SEE NOTE 3
200T5H2LM
131
10S2300-M3PH
174
SEE NOTE 3
200T6H2LM
150
371
10S4400-M3PH
202
SEE NOTE 3
200T7H2LM
169
390
10S4400-M3PH
202
SEE NOTE 3
200T8H2LM
188
507
10S4500-M3PH
300
SEE NOTE 3
200T9H2LM
207
18
Note: 1). For 7” diameter wells or larger. 2). Motor controls used on 3 phase units must be equipped with quick trip (10 seconds maximum) heaters on each leg or warranty is void. 3). Solid state starters sold separately. See motors and controls section. 4). For 460 volt pumps or motor, change the fourth digit to a 4 (Ex: 2004T501H2-3PH) (Ex:10S450-6M3PH) (460V not available in 1PH). 5). 50 cycle and 316 stainless steel motors are available upon request.
Complete Pump Numbering System Model Number: Nominal Rated Flow (GPM)
( )
2 = 230V 8 = 208V Voltage 3 = 380V 4 = 460V 5 = 575V Turbine Divide By 10 For Rated Motor HP (Example: 400 : 10 = 40 HP)
70
Pump Head Only - Numbering System
2002T2004H2-3PH Model Number: Motor Type: SP = 2 Wire Blank = 3 Wire 3 PH = 3 Phase
200T4H2LM
Nominal Rated Flow (GPM)
LM = Less Motor
Turbine
Impeller Trim
Impeller Trim Number of Stages
Effective Date: 4/08 Prices are subject to change without notice, catalog updated monthly.
Number of Stages
I/C SUBMERSIBLE TURBINE PUMP 230-400 GPM, 3450 RPM, 60 Cycle - Performance Curve 40 2504T6006L1
20
250 Series
700
0
NPSHR - (feet)
800
2504T5005L1
Total Dynamic Head (feet)
600
2504T4004L1
500
400
2502T3003L1
300 2502T2002L1 2502T1502L3
200
2502T1001L1 2502T751L3
100
Operating Range
0
0
100
200
300
400
500
600
Flow (gallons per minute) Note: For well of 9” or larger diameter. Caution: Do not use pump at flow rates outside of operating range. To do so can cause premature pump failure. These curves are based on factory tests when pumping clear, fresh, non-aerated water at a temperature not exceeding 85°F and under suction conditions as indicated. Due to production tolerances, these curves can vary plus or minus five percent.
Effective Date: 4/08 Prices are subject to change without notice, catalog updated monthly.
71
I/C SUBMERSIBLE TURBINE PUMP 250 Series Pump & Component Specifications Complete Pump SERIES WIRE
250
3
HP
Motor
MTR. STGS DISCH. LENGTH PH VOLTS DIA.
MODEL NO.
WT (LBS.)
MODEL NO.
Control Box WT (LBS.)
MODEL NO.
7.5
1
4.0”
55.05”
1
230
6”
2502T751L3
245
10S275-6M
123
31S275-M
7.5
1
4.0”
51.25”
3
230
6”
2502T751L3-3PH
230
10S275-6M3PH
108
SEE NOTE 3
10
1
4.0”
59.08”
1
230
6”
2502T1001L1
263
10S2100-6M
141
31S2100-M
10
1
4.0”
53.88”
3
230
6”
2502T1001L1-3PH
338
10S2100-6M3PH
116
SEE NOTE 3
15
2
4.0”
68.55”
1
230
6”
2502T1502L3
316
10S2150-M
154
31S2150-DM
Pump End
WT (LBS.)
MODEL NO.
WT (LBS.)
13.5
250T1L3LM
122
250T1L3LM
122
250T1L1LM
122
14.6
18
250T1L1LM
122
250T2L3LM
162
15
2
4.0”
62.75”
3
230
6”
2502T1502L3-3PH
291
10S2150-M3PH
129
SEE NOTE 3
250T2L3LM
162
20
2
4.0”
60.13”
3
230
6”
2502T2002L1-3PH
307
10S2200-M3PH
145
SEE NOTE 3
250T2L1LM
162
30
3
4.0”
71.50”
3
230
6”
2502T3003L1-3PH
376
10S2300-M3PH
174
SEE NOTE 3
250T3L1LM
202
40
4
4.0”
82.88”
3
460
6”
2504T4004L1-3PH
444
10S4400-M3PH
202
SEE NOTE 3
250T4L1LM
242
50
5
4.0”
106.13”
3
460
6”
2504T5005L1-3PH
582
10S4500-M3PH
300
SEE NOTE 3
250T5L1LM
282
60
6
4.0”
118.38”
3
460
6”
2504T6006L1-3PH
652
10S4600-M3PH
330
SEE NOTE 3
250T6L1LM
322
Note: 1). For 9” diameter wells or larger. 2). Motor controls used on 3 phase units must be equipped with quick trip (10 seconds maximum) heaters on each leg or warranty is void. 3). Solid state starters sold separately. See motors and controls section. 4). For 460 volt pumps or motor, change the fourth digit to a 4 (Ex: 2504T751L3-3PH) (Ex:10S475-6M3PH) (460V not available in 1PH). 5). 50 cycle and 316 stainless steel motors are available upon request.
Complete Pump Numbering System Model Number: Nominal Rated Flow (GPM)
( )
2 = 230V 8 = 208V Voltage 3 = 380V 4 = 460V 5 = 575V Turbine Divide By 10 For Rated Motor HP (Example: 400 : 10 = 40 HP)
72
Pump Head Only - Numbering System
2502T2002L1-3PH Model Number: Motor Type: SP = 2 Wire Blank = 3 Wire 3 PH = 3 Phase
250T2L1LM
Nominal Rated Flow (GPM)
LM = Less Motor
Turbine
Impeller Trim
Impeller Trim Number of Stages
Effective Date: 4/08 Prices are subject to change without notice, catalog updated monthly.
Number of Stages
I/C SUBMERSIBLE TURBINE PUMP 250-450 GPM, 3450 RPM, 60 Cycle - Performance Curve 40 3004T6006M1 20
300 Series
700
0
NPSHR - (feet)
800
3004T5005M1
Total Dynamic Head (feet)
600
3004T4004M1
500
400
3002T3003M1
300 3002T2002M1 3002T1502M3
200
3002T1001M1 3002T751M3
100
Operating Range
0
0
100
200
300
400
500
600
Flow (gallons per minute) Note: For well of 9” or larger diameter. Caution: Do not use pump at flow rates outside of operating range. To do so can cause premature pump failure. These curves are based on factory tests when pumping clear, fresh, non-aerated water at a temperature not exceeding 85°F and under suction conditions as indicated. Due to production tolerances, these curves can vary plus or minus five percent.
Effective Date: 4/08 Prices are subject to change without notice, catalog updated monthly.
73
I/C SUBMERSIBLE TURBINE PUMP 300 Series Pump & Component Specifications Complete Pump SERIES WIRE
300
3
HP
Motor
MTR. STGS DISCH. LENGTH PH VOLTS DIA.
MODEL NO.
WT (LBS.)
MODEL NO.
Control Box WT (LBS.)
MODEL NO.
WT (LBS.)
MODEL NO.
WT (LBS.)
7.5
1
4.0”
55.05”
1
230
6”
3002T751M3
245
10S275-6M
123
31S275-M
7.5
1
4.0”
51.25”
3
230
6”
3002T751M3-3PH
230
10S275-6M3PH
108
SEE NOTE 3
10
1
4.0”
59.08”
1
230
6”
3002T1001M1
263
10S2100-6M
141
31S2100-M
10
1
4.0”
53.88”
3
230
6”
3002T1001M1-3PH 238
10S2100-6M3PH
116
SEE NOTE 3
15
2
4.0”
68.55”
1
230
6”
3002T1502M3
10S2150-M
154
31S2150-DM
15
2
4.0”
62.75”
3
230
6”
3002T1502M3-3PH 291
10S2150-M3PH
129
SEE NOTE 3
300T2M3LM 162
20
2
4.0”
60.13”
3
230
6”
3002T2002M1-3PH 307
10S2200-M3PH
145
SEE NOTE 3
300T2M1LM 162
30
3
4.0”
71.50”
3
230
6”
3002T3003M1-3PH 376
10S2300-M3PH
174
SEE NOTE 3
300T3M1LM 202
40
4
4.0”
82.88”
3
460
6”
3004T4004M1-3PH 444
10S4400-M3PH
202
SEE NOTE 3
300T4M1LM 242
50
5
4.0”
106.13”
3
460
6”
3004T5005M1-3PH 582
10S4500-M3PH
300
SEE NOTE 3
300T5M1LM 282
60
6
4.0”
118.38”
3
460
6”
3004T6006M1-3PH 652
10S4600-M3PH
330
SEE NOTE 3
300T6M1LM 322
316
13.5
Pump End 300T1M3LM 122 300T1M3LM 122
14.6
300T1M1LM 122
18
300T2M3LM 162
300T1M1LM 122
Note: 1). For 9” diameter wells or larger. 2). Motor controls used on 3 phase units must be equipped with quick trip (10 seconds maximum) heaters on each leg or warranty is void. 3). Solid state starters sold separately. See motors and controls section. 4). For 460 volt pumps or motor, change the fourth digit to a 4 (Ex: 3004T751M3-3PH) (Ex:10S475-6M3PH) (460V not available in 1PH). 5). 50 cycle and 316 stainless steel motors are available upon request.
Complete Pump Numbering System Model Number: Nominal Rated Flow (GPM)
( )
2 = 230V 8 = 208V Voltage 3 = 380V 4 = 460V 5 = 575V Turbine Divide By 10 For Rated Motor HP (Example: 400 : 10 = 40 HP)
74
Pump Head Only - Numbering System
3002T1502M3-3PH Model Number: Motor Type: SP = 2 Wire Blank = 3 Wire 3 PH = 3 Phase
300T2M3LM
Nominal Rated Flow (GPM)
LM = Less Motor
Turbine
Impeller Trim
Impeller Trim Number of Stages
Effective Date: 4/08 Prices are subject to change without notice, catalog updated monthly.
Number of Stages
I/C SUBMERSIBLE TURBINE PUMP 300-500 GPM, 3450 RPM, 60 Cycle - Performance Curve 50 3504T12506H1 25
350 Series
700
10
NPSHR - (feet)
800
3504T10005H1
600
Total Dynamic Head (feet)
3504T7504H1 500
3504T6003H1
400
3502T3003H4
300
3504T4002H1 3502T2002H4
200
3502T2001H1 3502T1001H4
100
Operating Range
0
0
100
200
300
400
500
600
Flow (gallons per minute) Note: For well of 9” or larger diameter. Caution: Do not use pump at flow rates outside of operating range. To do so can cause premature pump failure. These curves are based on factory tests when pumping clear, fresh, non-aerated water at a temperature not exceeding 85°F and under suction conditions as indicated. Due to production tolerances, these curves can vary plus or minus five percent.
Effective Date: 4/08 Prices are subject to change without notice, catalog updated monthly.
75
I/C SUBMERSIBLE TURBINE PUMP 350 Series Pump & Component Specifications Complete Pump SERIES WIRE
350
3
HP
Motor
MTR. STGS DISCH. LENGTH PH VOLTS DIA.
MODEL NO.
WT (LBS.)
MODEL NO.
Control Box WT (LBS.)
Pump End
MODEL NO.
WT (LBS.)
MODEL NO.
WT (LBS.)
14.6
10
1
4.0”
59.08”
1
230
6”
3502T1001H4
263
10S2100-6M
141
31S2100-M
350T1H4LM
122
10
1
4.0”
53.88”
3
230
6”
3502T1001H4-3PH
238
10S2100-6M3PH
116
SEE NOTE 3
350T1H4LM
122
20
1
4.0”
53.88”
3
230
6”
3502T2001H1-3PH
267
10S2200-M3PH
145
SEE NOTE 3
350T1H1LM
122
20
2
4.0”
60.13”
3
230
6”
3502T2002H4-3PH
307
10S2200-M3PH
145
SEE NOTE 3
350T2H4LM
162
40
2
4.0”
70.38”
3
230
6”
3504T4002H1-3PH
364
10S4400-M3PH
202
SEE NOTE 3
350T2H1LM
162
30
3
4.0”
71.50”
3
230
6”
3502T3003H4-3PH
376
10S2300-M3PH
174
SEE NOTE 3
350T3H4LM
202
60
3
4.0”
99.63”
3
460
6”
3504T6003H1-3PH
532
10S4600-M3PH
330
SEE NOTE 3
350T3H1LM
202
75
4
4.0”
95.88”
3
460
8”
3504T7504H1-3PH
672
10S4750-M3PH
430
SEE NOTE 3
350T4H1LM
242
100
5
4.0”
110.13”
3
460
8”
3504T10005H1-3PH 812
10S41000-M3PH
530
SEE NOTE 3
350T5H1LM
282
125
6
4.0”
126.38”
3
460
8”
3504T12506H1-3PH 1022 10S41250-M3PH
700
SEE NOTE 3
350T6H1LM
322
Note: 1). For 9” diameter wells or larger. 2). Motor controls used on 3 phase units must be equipped with quick trip (10 seconds maximum) heaters on each leg or warranty is void. 3). Solid state starters sold separately. See motors and controls section. 4). For 460 volt pumps or motor, change the fourth digit to a 4 (Ex: 3504T751H4-3PH) (Ex:10S4100-6M3PH) (460V not available in 1PH). 5). 50 cycle and 316 stainless steel motors are available upon request.
Complete Pump Numbering System Model Number: Nominal Rated Flow (GPM)
( )
2 = 230V 8 = 208V Voltage 3 = 380V 4 = 460V 5 = 575V Turbine Divide By 10 For Rated Motor HP (Example: 400 : 10 = 40 HP)
76
Pump Head Only - Numbering System
3504T6003H1-3PH Model Number: Motor Type: SP = 2 Wire Blank = 3 Wire 3 PH = 3 Phase
350T3H1LM
Nominal Rated Flow (GPM)
LM = Less Motor
Turbine
Impeller Trim
Impeller Trim Number of Stages
Effective Date: 4/08 Prices are subject to change without notice, catalog updated monthly.
Number of Stages
I/C SUBMERSIBLE TURBINE PUMP 300-645 GPM, 3450 RPM, 60 Cycle - Performance Curve 50 25 700
Total Dynamic Head (feet)
600
500
500 Series
5004T7507M1
0
NPSHR - (feet)
800
5004T6006M1
5004T5005M1
400 5004T4004M1
300 5002T3003M1
200 5002T2002M1 5002T1502M3
100
5002T1001M1 5002T751M3 Operating Range
0
0
150
300
450
600
750
900
Flow (gallons per minute) Note: For well of 8” or larger diameter. Caution: Do not use pump at flow rates outside of operating range. To do so can cause premature pump failure. These curves are based on factory tests when pumping clear, fresh, non-aerated water at a temperature not exceeding 85°F and under suction conditions as indicated. Due to production tolerances, these curves can vary plus or minus five percent.
Effective Date: 4/08 Prices are subject to change without notice, catalog updated monthly.
77
I/C SUBMERSIBLE TURBINE PUMP 500 Series Pump & Component Specifications Complete Pump SERIES WIRE
500
3
HP
Motor
MTR. STGS DISCH. LENGTH PH VOLTS DIA.
MODEL NO.
WT (LBS.)
MODEL NO.
Control Box WT (LBS.)
MODEL NO.
Pump End
WT (LBS.)
MODEL NO.
WT (LBS.)
13.5
500T1M3LM
115
500T1M3LM
115
500T1M1LM
115
500T1M1LM
115
7.5
1
6.0”
57.43”
1
230
6”
5002T751M3
238
10S275-6M
123
31S275-M
7.5
1
6.0”
53.63”
3
230
6”
5002T751M3-3PH
223
10S275-6M3PH
108
SEE NOTE 3
10
1
6.0”
61.45”
1
230
6”
5002T1001M1
256
10S2100-6M
141
31S2100-M
10
1
6.0”
56.25”
3
230
6”
5002T1001M1-3PH 231
10S2100-6M3PH
116
SEE NOTE 3
15
2
6.0”
71.68”
1
230
6”
5002T1502M3
10S2150-M
154
31S2150-DM
15
2
6.0”
65.88”
3
230
6”
5002T1502M3-3PH 284
10S2150-M3PH
129
SEE NOTE 3
500T2M3LM 155
20
2
6.0”
63.25”
3
230
6”
5002T2002M1-3PH 300
10S2200-M3PH
145
SEE NOTE 3
500T2M1LM 155
30
3
6.0”
75.38”
3
230
6”
5002T3003M1-3PH 369
10S2300-M3PH
174
SEE NOTE 3
500T3M1LM 195
40
4
6.0”
87.50”
3
460
6”
5004T4004M1-3PH 437
10S4400-M3PH
202
SEE NOTE 3
500T4M1LM 235
50
5
6.0”
111.50”
3
460
6”
5004T5005M1-3PH 575
10S4500-M3PH
300
SEE NOTE 3
500T5M1LM 275
60
6
6.0”
124.50”
3
460
6”
5004T6006M1-3PH 645
10S4600-M3PH
330
SEE NOTE 3
500T6M1LM 315
75
7
6.0”
118.50”
3
460
8”
5004T7507M1-3PH 785
10S4750-M3PH
430
SEE NOTE 3
500T7M1LM 355
309
14.6
18
500T2M3LM 155
Note: 1). For 8” diameter wells or larger. 2). Motor controls used on 3 phase units must be equipped with quick trip (10 seconds maximum) heaters on each leg or warranty is void. 3). Solid state starters sold separately. See motors and controls section. 4). For 460 volt pumps or motor, change the fourth digit to a 4 (Ex: 5004T751M3-3PH) (Ex:10S475-6M3PH) (460V not available in 1PH). 5). 50 cycle and 316 stainless steel motors are available upon request.
Complete Pump Numbering System Model Number: Nominal Rated Flow (GPM)
( )
2 = 230V 8 = 208V Voltage 3 = 380V 4 = 460V 5 = 575V Turbine Divide By 10 For Rated Motor HP (Example: 400 : 10 = 40 HP)
78
Pump Head Only - Numbering System
5002T1502M3-3PH Model Number: Motor Type: SP = 2 Wire Blank = 3 Wire 3 PH = 3 Phase
500T2M3LM
Nominal Rated Flow (GPM)
LM = Less Motor
Turbine
Impeller Trim
Impeller Trim Number of Stages
Effective Date: 4/08 Prices are subject to change without notice, catalog updated monthly.
Number of Stages
I/C SUBMERSIBLE TURBINE PUMP 340-760 GPM, 3450 RPM, 60 Cycle - Performance Curve 50 25
5504T10005M1
550 Series
700
Total Dynamic Head (feet)
600
0
NPSHR - (feet)
800
5504T7504M1
500 5504T6003M1 400
300 5504T4002M1 5502T2502M3 200 5502T2001M1 100
5502T1501M3
Operating Range
0
0
200
400
600
800
1000
1200
Flow (gallons per minute) Note: For well of 8” or larger diameter. Caution: Do not use pump at flow rates outside of operating range. To do so can cause premature pump failure. These curves are based on factory tests when pumping clear, fresh, non-aerated water at a temperature not exceeding 85°F and under suction conditions as indicated. Due to production tolerances, these curves can vary plus or minus five percent.
Effective Date: 4/08 Prices are subject to change without notice, catalog updated monthly.
79
I/C SUBMERSIBLE TURBINE PUMP 550 Series Pump & Component Specifications Complete Pump SERIES WIRE
550
3
HP
Motor
MTR. STGS DISCH. LENGTH PH VOLTS DIA.
MODEL NO.
WT (LBS.)
15
1
6.0”
63.05”
1
230
6”
5502T1501M3
15
1
6.0”
57.25”
3
230
6”
5502T1501M3-3PH 243
267
Control Box MODEL NO.
MODEL NO.
WT (LBS.)
154
31S2150-DM
18
550T1M3LM
113
129
SEE NOTE 3
550T1M3LM
113 113
10S2150-M 10S2150-M3PH
MODEL NO.
Pump End
WT (LBS.)
WT (LBS.)
20
1
6.0”
54.63”
3
230
6”
5502T2001M1-3PH 258
10S2200-M3PH
145
SEE NOTE 3
550T1M1LM
25
2
6.0”
63.25”
3
230
6”
5502T2502M3-3PH 309
10S2250-M3PH
156
SEE NOTE 3
550T2M3LM 153
40
2
6.0”
70.88”
3
460
6”
5504T4002M1-3PH 355
10S4400-M3PH
202
SEE NOTE 3
550T2M1LM 153
60
3
6.0”
99.88”
3
460
6”
5504T6003M1-3PH 523
10S4600-M3PH
330
SEE NOTE 3
550T3M1LM 193
75
4
6.0”
92.88”
3
460
8”
5504T7504M1-3PH 663
10S4750-M3PH
430
SEE NOTE 3
550T4M1LM 233
100
5
6.0”
106.88”
3
460
8”
5504T10005M1-3PH 803
10S41000-M3PH
530
SEE NOTE 3
550T5M1LM 273
Note: 1). For 9” diameter wells or larger. 2). Motor controls used on 3 phase units must be equipped with quick trip (10 seconds maximum) heaters on each leg or warranty is void. 3). Solid state starters sold separately. See motors and controls section. 4). For 460 volt pumps or motor, change the fourth digit to a 4 (Ex: 5504T1501M3-3PH) (Ex:10S4150-6M3PH) (460V not available in 1PH). 5). 50 cycle and 316 stainless steel motors are available upon request.
Complete Pump Numbering System Model Number: Nominal Rated Flow (GPM)
( )
Model Number:
2 = 230V 8 = 208V Voltage 3 = 380V 4 = 460V 5 = 575V
Motor Type: SP = 2 Wire Blank = 3 Wire 3 PH = 3 Phase
Turbine
Impeller Trim
Divide By 10 For Rated Motor HP (Example: 400 : 10 = 40 HP)
Number of Stages
80
Pump Head Only - Numbering System
5504T6003M1-3PH 550T3M1LM
Nominal Rated Flow (GPM)
LM = Less Motor
Turbine
Impeller Trim
Effective Date: 4/08 Prices are subject to change without notice, catalog updated monthly.
Number of Stages
I/C SUBMERSIBLE TURBINE PUMP 360-760 GPM, 3450 RPM, 60 Cycle - Performance Curve 80 40 6004T10004L2
600 Series
700
0
NPSHR - (feet)
800
600
Total Dynamic Head (feet)
6004T7503L2 500 6004T7502L1 400 6004T5002L2
300
6004T4001L1 200
6002T2501L2
100
Operating Range
0
0
200
400
600
800
1000
1200
Flow (gallons per minute) Note: For well of 11” or larger diameter. Caution: Do not use pump at flow rates outside of operating range. To do so can cause premature pump failure. These curves are based on factory tests when pumping clear, fresh, non-aerated water at a temperature not exceeding 85°F and under suction conditions as indicated. Due to production tolerances, these curves can vary plus or minus five percent.
Effective Date: 4/08 Prices are subject to change without notice, catalog updated monthly.
81
I/C SUBMERSIBLE TURBINE PUMP 600 Series Pump & Component Specifications Complete Pump SERIES WIRE
600
3
HP
Motor
MTR. STGS DISCH. LENGTH PH VOLTS DIA.
MODEL NO.
WT (LBS.)
Control Box
MODEL NO.
WT (LBS.)
MODEL NO.
WT (LBS.)
Pump End MODEL NO.
WT (LBS.) 188
25
1
6.0”
65.25”
3
230
6”
6002T2501L2-3PH
344
10S2250-M3PH
156
SEE NOTE 3
600T1L2LM
40
1
6.0”
72.88”
3
460
6”
6004T4001L1-3PH
390
10S4400-M3PH
202
SEE NOTE 3
600T1L1LM
188
50
2
6.0”
95.13”
3
460
6”
6004T5002L2-3PH
548
10S4500-M3PH
300
SEE NOTE 3
600T2L2LM
248
75
2
6.0”
90.63”
3
460
8”
6004T7502L1-3PH
678
10S4750-M3PH
430
SEE NOTE 3
600T2L1LM
248
75
3
6.0”
98.38”
3
460
8”
6004T7503L2-3PH
738
10S4750-M3PH
430
SEE NOTE 3
600T3L2LM
308
100
4
6.0”
114.13”
3
460
8”
6004T10004L2-3PH 898
10S41000-M3PH
530
SEE NOTE 3
600T4L2LM
368
Note: 1). For 11” diameter wells or larger. 2). Motor controls used on 3 phase units must be equipped with quick trip (10 seconds maximum) heaters on each leg or warranty is void. 3). Solid state starters sold separately. See motors and controls section. 4). For 460 volt pumps or motor, change the fourth digit to a 4 (Ex: 6004T2501-3PH) (Ex:10S4250-6M3PH) (460V not available in 1PH). 5). 50 cycle and 316 stainless steel motors are available upon request.
Complete Pump Numbering System Model Number: Nominal Rated Flow (GPM)
( )
2 = 230V 8 = 208V Voltage 3 = 380V 4 = 460V 5 = 575V Turbine Divide By 10 For Rated Motor HP (Example: 400 : 10 = 40 HP)
82
Pump Head Only - Numbering System
6004T7502L1-3PH Model Number: Motor Type: SP = 2 Wire Blank = 3 Wire 3 PH = 3 Phase
600T2L1LM
Nominal Rated Flow (GPM)
LM = Less Motor
Turbine
Impeller Trim
Impeller Trim Number of Stages
Effective Date: 4/08 Prices are subject to change without notice, catalog updated monthly.
Number of Stages
I/C SUBMERSIBLE TURBINE PUMP 500-800 GPM, 3450 RPM, 60 Cycle - Performance Curve 100
650 Series
700
Total Dynamic Head (feet)
600
50
NPSHR - (feet)
800
0
6504T10002M1
500
400 6504T6002M2
300 6504T5001M1
200
6502T3001M2
100
Operating Range
0
0
200
400
600
800
1000
1200
Flow (gallons per minute) Note: For well of 11” or larger diameter. Caution: Do not use pump at flow rates outside of operating range. To do so can cause premature pump failure. These curves are based on factory tests when pumping clear, fresh, non-aerated water at a temperature not exceeding 85°F and under suction conditions as indicated. Due to production tolerances, these curves can vary plus or minus five percent.
Effective Date: 4/08 Prices are subject to change without notice, catalog updated monthly.
83
I/C SUBMERSIBLE TURBINE PUMP 650 Series Pump & Component Specifications Complete Pump
Motor
MTR. STGS DISCH. LENGTH PH VOLTS DIA.
WT (LBS.)
MODEL NO.
Control Box WT (LBS.)
MODEL NO.
WT (LBS.)
Pump End MODEL NO.
WT (LBS.)
SERIES WIRE
HP 30
1
6.0”
67.75”
3
230
6”
6502T3001M2-3PH 362
10S2300-M3PH
174
SEE NOTE 3
650T1M2LM 188
650
50
1
6.0”
87.38”
3
460
6”
6504T5001M1-3PH 488
10S4500-M3PH
300
SEE NOTE 3
650T1M1LM 188
60
2
6.0”
101.13”
3
460
6”
6504T6002M2-3PH 578
10S4600-M3PH
330
SEE NOTE 3
650T2M2LM 248
100
2
6.0”
98.63”
3
460
8”
6504T10002M1-3PH 778
10S41000-M3PH
530
SEE NOTE 3
650T2M1LM 248
3
MODEL NO.
Note: 1). For 11” diameter wells or larger. 2). Motor controls used on 3 phase units must be equipped with quick trip (10 seconds maximum) heaters on each leg or warranty is void. 3). Solid state starters sold separately. See motors and controls section. 4). For 460 volt pumps or motor, change the fourth digit to a 4 (Ex: 6504T3001M2-3PH) (Ex:10S4300-M3PH) (460V not available in 1PH). 5). 50 cycle and 316 stainless steel motors are available upon request.
Complete Pump Numbering System Model Number: Nominal Rated Flow (GPM)
( )
2 = 230V 8 = 208V Voltage 3 = 380V 4 = 460V 5 = 575V Turbine Divide By 10 For Rated Motor HP (Example: 400 : 10 = 40 HP)
84
Pump Head Only - Numbering System
6504T6002M2-3PH Model Number: Motor Type: SP = 2 Wire Blank = 3 Wire 3 PH = 3 Phase
650T2M2LM
Nominal Rated Flow (GPM)
LM = Less Motor
Turbine
Impeller Trim
Impeller Trim Number of Stages
Effective Date: 4/08 Prices are subject to change without notice, catalog updated monthly.
Number of Stages
I/C SUBMERSIBLE TURBINE PUMP 600-1200 GPM, 3450 RPM, 60 Cycle - Performance Curve 800
50
900 Series
700
0
NPSHR - (feet)
100
Total Dynamic Head (feet)
600
9004T12503H2
500
9004T15002H1 400 9004T7502H2 300 9004T7501H1 200 9004T4001H2
100
Operating Range
0
0
300
600
900
1200
1500
1800
Flow (gallons per minute) Note: For well of 12” or larger diameter. Caution: Do not use pump at flow rates outside of operating range. To do so can cause premature pump failure. These curves are based on factory tests when pumping clear, fresh, non-aerated water at a temperature not exceeding 85°F and under suction conditions as indicated. Due to production tolerances, these curves can vary plus or minus five percent.
Effective Date: 4/08 Prices are subject to change without notice, catalog updated monthly.
85
I/C SUBMERSIBLE TURBINE PUMP 900 Series Pump & Component Specifications Complete Pump SERIES WIRE
900
3
HP
Motor
MTR. STGS DISCH. LENGTH PH VOLTS DIA.
MODEL NO.
WT (LBS.)
Control Box
MODEL NO.
WT (LBS.)
MODEL NO.
WT (LBS.)
Pump End MODEL NO.
WT (LBS.)
40
1
6.0”
73.25”
3
460
6”
9004T4001H2-3PH
404
10S4400-M3PH
202
SEE NOTE 3
900T1H2LM
202
75
1
6.0”
83.25”
3
460
8”
9004T7501H1-3PH
632
10S4750-M3PH
430
SEE NOTE 3
900T1H1LM
202
707
10S4750-M3PH
277
75
2
6.0”
90.50”
3
460
8”
9004T7502H2-3PH
430
SEE NOTE 3
900T2H2LM
150
2
6.0”
117.50”
3
460
8”
9004T15002H1-3PH 1117 10S41500-M3PH
840
SEE NOTE 3
900T2H1LM
277
125
3
6.0”
115.75”
3
460
8”
9004T12503H2-3PH 1052 10S41250-M3PH
700
SEE NOTE 3
900T3H2LM
352
Note: 1). For 12” diameter wells or larger. 2). Motor controls used on 3 phase units must be equipped with quick trip (10 seconds maximum) heaters on each leg or warranty is void. 3). Solid state starters sold separately. See motors and controls section. 4). 460V not available in 1PH. 5). 50 cycle and 316 stainless steel motors are available upon request.
Complete Pump Numbering System Model Number: Nominal Rated Flow (GPM)
( )
2 = 230V 8 = 208V Voltage 3 = 380V 4 = 460V 5 = 575V Turbine Divide By 10 For Rated Motor HP (Example: 400 : 10 = 40 HP)
86
Pump Head Only - Numbering System
9004T15002H1-3PH Model Number: Motor Type: SP = 2 Wire Blank = 3 Wire 3 PH = 3 Phase
900T2H1LM
Nominal Rated Flow (GPM)
LM = Less Motor
Turbine
Impeller Trim
Impeller Trim Number of Stages
Effective Date: 4/08 Prices are subject to change without notice, catalog updated monthly.
Number of Stages
I/C SUBMERSIBLE TURBINE PUMP 600-1400 GPM, 3450 RPM, 60 Cycle - Performance Curve 600
50
1000 Series 500
NPSHR - (feet)
100
0
Total Dynamic Head (feet)
400 10004T12502H1
300 10004T7502H2
200 10004T6001H1
10004T4001H2
100
Operating Range
0
0
200
400
600
800
1000
1200
1400
1600
Flow (gallons per minute) Note: For well of 10” or larger diameter. Caution: Do not use pump at flow rates outside of operating range. To do so can cause premature pump failure. These curves are based on factory tests when pumping clear, fresh, non-aerated water at a temperature not exceeding 85°F and under suction conditions as indicated. Due to production tolerances, these curves can vary plus or minus five percent.
Effective Date: 4/08 Prices are subject to change without notice, catalog updated monthly.
87
I/C SUBMERSIBLE TURBINE PUMP 1000 Series Pump & Component Specifications Complete Pump
Motor
MTR. STGS DISCH. LENGTH PH VOLTS DIA.
WT (LBS.)
MODEL NO.
Control Box WT (LBS.)
MODEL NO.
WT (LBS.)
Pump End MODEL NO.
WT (LBS.)
SERIES WIRE
HP 40
1
6.0”
73.25”
3
460
6”
10004T4001H2-3PH 384 10S4400-M3PH
202
SEE NOTE 3
1000T1H2LM 182
1000
60
1
6.0”
93.75”
3
460
6”
10004T6001H1-3PH 512 10S4600-M3PH
330
SEE NOTE 3
1000T1H1LM 182
3
MODEL NO.
75
2
6.0”
91.75”
3
460
8”
10004T7502H2-3PH 665 10S4750-M3PH
430
SEE NOTE 3
1000T2H2LM 235
125
2
6.0”
109.75”
3
460
8”
10004T12502H1-3PH 935 10S41250-M3PH
700
SEE NOTE 3
1000T2H1LM 235
Note: 1). For 10” diameter wells or larger. 2). Motor controls used on 3 phase units must be equipped with quick trip (10 seconds maximum) heaters on each leg or warranty is void. 3). Solid state starters sold separately. See motors and controls section. 4). 460V not available in 1PH. 5). 50 cycle and 316 stainless steel motors are available upon request.
Complete Pump Numbering System
Pump Head Only - Numbering System
Model Number: 10004T7502H2-3PH Nominal Rated Flow (GPM)
( )
2 = 230V 8 = 208V Voltage 3 = 380V 4 = 460V 5 = 575V Turbine Divide By 10 For Rated Motor HP (Example: 400 : 10 = 40 HP)
88
Model Number: Motor Type: SP = 2 Wire Blank = 3 Wire 3 PH = 3 Phase
1000T2H2LM
Nominal Rated Flow (GPM)
LM = Less Motor
Turbine
Impeller Trim
Impeller Trim Number of Stages
Effective Date: 4/08 Prices are subject to change without notice, catalog updated monthly.
Number of Stages
I/C SUBMERSIBLE TURBINE PUMP 1000-1500 GPM, 3450 RPM, 60 Cycle - Performance Curve 150 12504T15003M2 100
1250 Series 500 12504T1502M1
NPSHR - (feet)
600
50
0
400 Total Dynamic Head (feet)
12504T10002M2
300 12504T7501M1
200 12504T5001M2
100
Operating Range
0
0
250
500
750
1000
1250
1500
1750
2000
Flow (gallons per minute) Note: For well of 12” or larger diameter. Caution: Do not use pump at flow rates outside of operating range. To do so can cause premature pump failure. These curves are based on factory tests when pumping clear, fresh, non-aerated water at a temperature not exceeding 85°F and under suction conditions as indicated. Due to production tolerances, these curves can vary plus or minus five percent.
Effective Date: 4/08 Prices are subject to change without notice, catalog updated monthly.
89
I/C SUBMERSIBLE TURBINE PUMP 1250 Series Pump & Component Specifications Complete Pump SERIES WIRE
1250
3
HP
STGS DISCH. LENGTH
Motor
MTR. PH VOLTS DIA.
MODEL NO.
WT (LBS.)
MODEL NO.
Control Box WT (LBS.)
MODEL NO.
WT (LBS.)
Pump End MODEL NO.
WT (LBS.)
50
1
6” or 8” 91.38”
3
460
6” 12504T5001M2-3PH
539 10S4500-M3PH
300
SEE NOTE 3
1250T1M2LM 239
75
1
6” or 8” 86.88”
3
460
8” 12504T7501M1-3PH
669 10S4750-M3PH
430
SEE NOTE 3
1250T1M1LM 239
100
2
6” or 8” 103.38”
3
460
8” 12504T10002M2-3PH 844 10S41000-M3PH
530
SEE NOTE 3
1250T2M2LM 314
150
2
6” or 8” 122.38”
3
460
8” 12504T15002M1-3PH 1154 10S41500-M3PH
840
SEE NOTE 3
1250T2M1LM 314
150
3
6” or 8” 130.88”
3
460
8” 12504T15003M2-3PH 1229 10S41500-M3PH
840
SEE NOTE 3
1250T3M2LM 389
Note: 1). For 12” diameter wells or larger. 2). Motor controls used on 3 phase units must be equipped with quick trip (10 seconds maximum) heaters on each leg or warranty is void. 3). Solid state starters sold separately. See motors and controls section. 4). 460V not available in 1PH. 5). 50 cycle and 316 stainless steel motors are available upon request.
Complete Pump Numbering System
Pump Head Only - Numbering System
Model Number: 12504T10002M2-3PH Nominal Rated Flow (GPM)
( )
2 = 230V 8 = 208V Voltage 3 = 380V 4 = 460V 5 = 575V Turbine Divide By 10 For Rated Motor HP (Example: 400 : 10 = 40 HP)
90
Model Number: Motor Type: SP = 2 Wire Blank = 3 Wire 3 PH = 3 Phase
1250T2M2LM
Nominal Rated Flow (GPM)
LM = Less Motor
Turbine
Impeller Trim
Impeller Trim Number of Stages
Effective Date: 4/08 Prices are subject to change without notice, catalog updated monthly.
Number of Stages
I/C SUBMERSIBLE TURBINE PUMP 1000-1750 GPM, 3450 RPM, 60 Cycle - Performance Curve 100
50
13504T17503H2
1350 Series 500
NPSHR - (feet)
600
0 13504T20002H1
Total Dynamic Head (feet)
400 13504T12502H2
300
13504T10001H1
200 13504T6001H2
100
Operating Range
0
0
250
500
750
1000
1250
1500
1750
2000
Flow (gallons per minute) Note: For well of 12” or larger diameter. Caution: Do not use pump at flow rates outside of operating range. To do so can cause premature pump failure. These curves are based on factory tests when pumping clear, fresh, non-aerated water at a temperature not exceeding 85°F and under suction conditions as indicated. Due to production tolerances, these curves can vary plus or minus five percent.
Effective Date: 4/08 Prices are subject to change without notice, catalog updated monthly.
91
I/C SUBMERSIBLE TURBINE PUMP 1350 Series Pump & Component Specifications Complete Pump SERIES WIRE
1350
3
HP
Motor
MTR. STGS DISCH. LENGTH PH VOLTS DIA.
MODEL NO.
WT (LBS.)
MODEL NO.
570 10S4600-M3PH
Control Box WT (LBS.)
MODEL NO.
WT (LBS.)
Pump End MODEL NO.
WT (LBS.)
60
1
6” or 8” 97.38”
3
460
6”
13504T6001H2-3PH
330
SEE NOTE 3
1350T1H2LM 240
100
1
6” or 8” 94.88”
3
460
8”
13504T10001H1-3PH 770 10S41000-M3PH
530
SEE NOTE 3
1350T1H1LM 240
125
2
6” or 8” 113.38”
3
460
8”
13504T12502H2-3PH 1015 10S41250-M3PH
700
SEE NOTE 3
1350T2H2LM 315
200
2
6” or 8” 139.38”
3
460
8”
13504T20002H1-3PH 1355 10S42000-M3PH 1040 SEE NOTE 3
1350T2H1LM 315
175
3
6” or 8” 138.88”
3
460
8”
13504T17503H2-3PH 1315 10S41750-M3PH
1350T3H2LM 390
925
SEE NOTE 3
Note: 1). For 12” diameter wells or larger. 2). Motor controls used on 3 phase units must be equipped with quick trip (10 seconds maximum) heaters on each leg or warranty is void. 3). Solid state starters sold separately. See motors and controls section. 4). 460V not available in 1PH. 5). 50 cycle and 316 stainless steel motors are available upon request.
Complete Pump Numbering System
Pump Head Only - Numbering System
Model Number: 13504T20002H1-3PH Nominal Rated Flow (GPM)
( )
2 = 230V 8 = 208V Voltage 3 = 380V 4 = 460V 5 = 575V Turbine Divide By 10 For Rated Motor HP (Example: 400 : 10 = 40 HP)
92
Model Number: Motor Type: SP = 2 Wire Blank = 3 Wire 3 PH = 3 Phase
1350T2H1LM
Nominal Rated Flow (GPM)
LM = Less Motor
Turbine
Impeller Trim
Impeller Trim Number of Stages
Effective Date: 4/08 Prices are subject to change without notice, catalog updated monthly.