PRODUCT CATALOG 2011 A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com responsible energy ...

1 downloads 213 Views 11MB Size
PRODUCT CATALOG 2011

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com responsible

energy

A DIVISION OF

NSi INDUSTRIES, LLC

NSi Industries LLC

About Us Since 1975, NSi’s strength is in the unique products that we bring to the market, combined with our exceptional ability to provide quality TORK® brand products manufactured in the company’s Mount Vernon facility. TORK® is NSi Industries largest brand, covering the categories of Electromechanical and Digital Time Switches, Signaling and Alert Devices, Pool and Spa Controls, Residential Timers, Photocontrols and Occupancy Sensors. For over 85 years, TORK brand recognition and reputation for quality and design make it the most specified brand in the industry. The TORK brand has a rich history beginning in the 1920s when the company introduced the first electromechanical time switch to the marketplace. Currently, TORK’s time switches maintain energy efficiency through lighting control in such high profile places as the Empire State Building, Washington DC Parks and Recreation, The Triborough Bridge, The Met Life Building and many more institutions across the country. As the most specified brand of time switches in the industry, TORK enjoys the hearty respect of engineers and project planners across all channels of distribution. In the past several years, we’ve introduced a number of TORK time switches, in-wall and plug-in timers to meet increasingly specific needs in the marketplace. We’ve also added a line of installer-friendly pool and spa panels and time switches, and are proud to offer essential pool safety products that meet and exceed federal requirements for safe pools. We look forward to designing and engineering more of our Responsible Energy products, helping save money and the environment through responsible and minimal use of energy.

TABLE OF CONTENTS

TABLE OF CONTENTS

ENERGY CODE REFERENCE GUIDE . . . . . . . . . . . . . 7 PHOTOCONTROLS

QUICK LOOK FEATURES & COMMON FEATURES . . . 2100 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2110 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2000 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2001 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2020 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3000 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5000M SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 2005A, 2007A, 2008A SERIES . . . . . . . . . . . . . . . 5200 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5400 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5737 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . PHOTOCONTROL ACCESSORIES . . . . . . . . . . . . . . .

11 13 14 15 16 17 18 19 20 21 22 23 24

ELECTROMECHANICAL

QUICK LOOK FEATURES & COMMON FEATURES . . . 27 TU40 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 1100 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 7000 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 7000Z SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 8000 SERIES, DUTY CYCLE . . . . . . . . . . . . . . . . . . 37 8000 SERIES, REPEATING VARIABLE CYCLE . . . . . . 39 WH2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 1800 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 W SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 T900 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 TW SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 TZ SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 ELECTROMECHANICAL ENCLOSURES & DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . 153 DIGITAL

QUICK LOOK FEATURES . . . . . . . . . . . . . . . . . . . . 53 DTU40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

DTWH40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 E SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 E-PB SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 EW SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 EWZ SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 DG100 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 DZS SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 DTS SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 DW SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 DZM SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 ELC SERIES, 1 & 2 ZONE . . . . . . . . . . . . . . . . . . . 73 ELC SERIES, 4, 8 &12 ZONE . . . . . . . . . . . . . . . . . 75 LC200 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 DGU SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 DGLC SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 DLC400BP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 LD SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 DGS SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 EJWT & E500T SERIES . . . . . . . . . . . . . . . . . . . . . 87 DIN SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 SMC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91 5401 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 HPS STARTER . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93 TRP SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 DIGITAL ENCLOSURES & DIMENSIONS . . . . . . . . . 153 IN-WALL TIMERS

QUICK LOOK FEATURES . . . . . . . . . . . . . . . . . . . . 97 SS720A SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . 98 SS700Z SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . 99 SS721Z SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . 99 701A SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 711A SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 SSA SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 SS SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103

D SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104 A SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 C SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 OCCUPANCY SENSORS

SENSOR TECHNOLOGY & PLACEMENT GUIDE . . . . 109 OSWS SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . 110 OSC15PLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111 OSC12PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112 OSC5PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112 OSC20UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .113 OSC SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114 ELS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 TRP-U . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116 PLUG-IN TIMERS

400A SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 400D SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 600A SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 600D SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . 800 SERIES . . . . . . . . . . . . . . . . . . . . . . . . . . . TORK ALERT

119 120 121 122 123

MECHANICAL STROBE HORNS . . . . . . . . . . . . . . . MECHANICAL HORNS . . . . . . . . . . . . . . . . . . . . . MULTI-TONE ELECTRONIC HORNS . . . . . . . . . . . . HEAVY DUTY BELLS . . . . . . . . . . . . . . . . . . . . . . BELLS & BUZZERS . . . . . . . . . . . . . . . . . . . . . . . CHIMES & CHIME KITS . . . . . . . . . . . . . . . . . . . . WEATHERPROOF MOTOR DRIVEN SIREN . . . . . . . MANUAL FIRE ALARM . . . . . . . . . . . . . . . . . . . . TELEPHONE STROBE . . . . . . . . . . . . . . . . . . . . . . TELEPHONE HORN . . . . . . . . . . . . . . . . . . . . . . . TELEPHONE RELAY . . . . . . . . . . . . . . . . . . . . . . . WALL CLOCKS . . . . . . . . . . . . . . . . . . . . . . . . . . ELECTRIC DOOR OPENERS . . . . . . . . . . . . . . . . . PUSH-BUTTONS . . . . . . . . . . . . . . . . . . . . . . . . .

127 127 128 128 129 129 130 130 131 131 132 132 133 134

WARNING LIGHTS, INDUSTRIAL . . . . . . . . . . . . . 135 WARNING LIGHTS, VEHICULAR . . . . . . . . . . . . . . 136 POWER SUPPLY UNITS . . . . . . . . . . . . . . . . . . . . 137 TRANSFORMERS . . . . . . . . . . . . . . . . . . . . . . . . . 137 ACCESSORIES/REPLACEMENT PARTS/DIMENSIONS 138 POOL & SPA

PP PANEL SERIES TIMERS . . . . . . . . . . . . . . . . . . 141 PFP PANEL SERIES TIMERS . . . . . . . . . . . . . . . . . 143 1100 SERIES TIMERS . . . . . . . . . . . . . . . . . . . . . 144 DW200B TIMER . . . . . . . . . . . . . . . . . . . . . . . . . 145 P1100 SERIES, 24 HOUR ELECTROMECHANICAL MECHANISMS . . . . . . . . . . 147 P1100 SERIES, 7 DAY DIGITAL MECHANISMS . . . 148 JUNCTION BOXES . . . . . . . . . . . . . . . . . . . . . . . 148 STINGL SR-500 & SR-500PS, SVRS . . . . . . . . . . 149 LAYERS OF PROTECTION . . . . . . . . . . . . . . . . . . . 150 ANTI-ENTRAPMENT DRAIN COVERS . . . . . . . . . . . 151 MAGNALATCH SELF-LATCHING GATE CLOSURES . . 152 TRUCLOSE SELF-CLOSING GATE HINGES . . . . . . . .152 POOL&SPA SAFETY ACCESSORIES . . . . . . . . . . . . 152 ENCLOSURE DIMENSIONS . . . . . . . . . . . . . . . . . . 153 ALPHANUMERIC INDEX . . . . . . . . . . . . . . . . . . . 155

LA N AR CH ITE CT U

energy saving solutions

Each of these marked products have features that decrease energy consumption and/or damage to the environment by one or more of the following: • Timed control, Photocontrol and/or Astronomic control of on responsible energy and off functions of lighting, fans, pumps and appliances  • Timed control of systems or multiple zones of lighting • Photo or occupancy sensing control of lighting • Supercapacitor backup, no batteries to replace or dispose. • Helps meet CA Title 24, ASHRAE , IECC and other standards for responsible building products

Small Space, Meeting Rooms, Restrooms, Storage Spaces: Occupancy Sensors, Interval Timers The first zone includes small spaces such as offices, restrooms and storage areas places where people may not occupy the space continuously. Individual wall switch replacement provides low cost installation, with occupancy sensors and interval timers as the best solution. In the event that wall switches provide proper coverage for the occupancy sensor, ceiling mounted options are available.

FIC ES

energy

< Use the Quick Reference Energy Code Guide for approved products.

responsible

energy

RE CE P

TIO

N

responsible

ZONE 1: SMALL SPACE

Responsible Energy

OF

< Responsible Energy is the mark of TORK’s commitment to developing and manufacturing energy saving, environmentally friendly products.

FIC ES

solutions

The first way to save energy begins with eliminating lighting when it isn't needed. As with exterior lighting, an efficient design matches controls to the typical use of the area.

OF

energy saving

INTERIOR LIGHTING ZONES

RA L&

ENERGY CODE REFERENCE GUIDE

ZONE 2: LARGE SPACE Small Space, Meeting Rooms, Restrooms, Storage Spaces: Time of Day with Override, Occupancy Sensors

CALIFORNIA Title 24

LO

T

The first zone includes small spaces such as offices, restrooms and storage areas places where people may not occupy the space continuously. Individual wall switch replacement provides low cost installation, with occupancy sensors and interval timers as the best solution. In the event that wall switches provide proper coverage for the occupancy sensor, ceiling mounted options are available.

ZONE 3: HARVESTING LIGHT

CE

ON

T

RO

EXTERIOR LIGHTING ZONES

EN

When ambient light levels drop at dusk, lighting is needed to provide safety and security. BUT: Does all lighting need to be on all night long? The proper selection of lighting controls is essential to ensuring that energy is only used when needed. An efficient lighting control design creates zones of light levels that can be varied by time at night.

Large of Small Spaces with Natural Light: Light Sensors, Light Sensors with Occupancy, Astronomic Timers. A third zone that uses daylighting control can be added to wither of the first two zones. light sensors can shut off a portion of the lighting when windows or skylights contribute sufficient natural light to the area. This "harvesting" of light is an excellent, green way to conserve energy. (NOTE: Energy codes vary on the stated maximum time, but shorter times can give more energy savings).

E

FIC FIC

The first zone gives a minimum light level where security is the primary need. Determine what lighting is necessary, such as building-mounted wallpacks and a portion of the parking lot lighting. These should be on from dusk to dawn, and are best controlled by a photosensor device.

OF

ST

RE

Security Lighting (all night): Photocontrols, Photosensor controls

OF

WA R

EH

OU

SE

ZONE 1: MINIMUM LIGHT LEVEL / DUSK TO DAWN

E

RO

O

M

OF

RE

FIC

E

ST

RO

O

M

CO

NF

ER

FR

B RO REA OM K

OM

PA R

KIN

G

ASHRAE 90.1

ZONE 2: HIGHER LIGHT LEVEL / DUSK TO TIME OFF

FRONT PARKING LOT

Safety & Architectural Lighting (not necessary all night): Photosensor/Timebased controls, Astronomic controls The second zone provides a higher light level for safety, when people are normally present. Maximum levels for the parking lot and all walkway lighting are needed. These lights are best controlled by a combination photosensor and time-based device to allow shut-off during the night. The astronomic-calculated sunset/time control can also be useful.

ZONE 3: ARCHITECTURAL / TIMED DUSK TO TIMED OFF

ARCHITECTURAL & LANDSCAPING DOCKS & BACK PARKING LOT

CONFERENCE ROOM

RECEPTION OFFICES

WAREHOUSE

OFFICES RESTROOM

RESTROOM

Building Facade, Landscape and Signage: Astronomic controls The third zone covers architectural lighting for building facade or landscape and signs. These are best controlled with an astronomic-calculated sunset/time control.

TORK 7

OFFICE OFFICE OFFICE

BREAK ROOM

TORK 8

PHOTOCONTROLS

FEATURES QUICK LOOK

COMMON FEATURES CHOICE OF PHOTOCELLS Cadmium sulphide, epoxysealed cells. Available in 1⁄2” and 1".

2100 SERIES

2110 SERIES

2000 SERIES

2001 SERIES

2020 SERIES

3000 SERIES

5000M SERIES

2005A SERIES

5200 SERIES

5737 SERIES

Page

13

14

15

16

17

18

19

20

21

23

Mounting

Conduit

Conduit

Conduit

Conduit

Conduit

Flush

Turn-Lock

Turn-Lock

Turn-Lock

Turn-Lock

Yes

Yes

Adjustable Swivel Housing

Die Cast Die Cast Zinc Aluminum

UV Stabilized UV Stabilized UV Stabilized Plastic Plastic Plastic

UV Stabilized Plastic

Lexan®

Lexan®

Lexan®

Lexan®

1 - 5 fc

1 - 5 fc

1 to 3 fc

1 to 3 fc

1.5 fc

5 fc

Turn ON Light Level

1 - 5 fc

1 - 5 fc

1 - 5 fc

1 - 5 fc

Adjustable light level adjustment

Yes

Yes

Yes

Yes

Turn OFF Ratio

3:1

3:1

3:1

3:1

3:1

3:1

5:1

3:1

1.5:1

1.5:1

Time Delay ON

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Instant

Instant

Instant

Time Delay OFF

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Light Sensor

CdS

CdS

CdS

CdS

CdS

CdS

CdS

CdS

Silicon Diode

Silicon Diode

CFL Compatible

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Surge Protection Photo Timer

TOUGH ENCLOSURES All conduit and flush mounted models utilize die-cast zinc, die cast aluminum, or genuine Lexan® materials. All turn-lock models utilize high impact UV stabilized polypropylene, ABS, PBT or Lexan® materials.

CHOICE OF MOUNTING ORIENTATION Models are available in fixed position or 180° swivel.

DEPENDABLE performance Built-in time delay prevents false switching due to light from passing highway vehicles, lightning, etc. Instant response is available in turn-lock models (5200 Series).

TURN-LOCKS MEET ANSI C136.10

Yes

All models meet the current ANSI requirements for locking-type prongs and color coded voltage designations. Locking prongs are solid brass.

TORK® Photocontrols are designed and manufactured with components which adhere to the highest industry standards. Trained personnel and in-process quality procedures ensure that every unit meets our strictest quality standards.

TORK 11

Color-Coded Dome Grey 105-130VAC Maroon 208-277VAC Blue 105-285VAC Yellow 480VAC Green 347VAC

TORK 12

2100 SERIES

SPECIFICATIONS

SPECIFICATION GRADE 1/2" CONDUIT MOUNTING DIE CAST ZINC PHOTOCONTROL

ON/OFF: Turn ON is 1 to 5fc, Turn OFF is 3 to 15fc, without the slide in position. ON/OFF adjustment is easily made by moving a slide cover. No tools required.

APPLICATIONS

SPECIFICATIONS

SPECIFICATION GRADE 1/2" CONDUIT MOUNTING DIE CAST ALUMINUM PHOTOCONTROL

ON/OFF: Turn ON is 1 to 5fc, Turn OFF is 3 to 15fc, without the slide in position. ON/OFF adjustment is easily made by moving a slide cover. No tools required.

TIME DELAY: ON and OFF.

TIME DELAY: ON and OFF.

CELL: Cadmium sulphide, epoxy-coated, 1" diameter.

CELL: Cadmium sulphide, epoxy-coated, 1⁄2” diameter. Model 2117 is 1" cell.

CONTACTS: Remain closed between dusk and dawn. (The unit fails in the ON position).

Parking lot lighting Building perimeter lighting Outdoor signage

2110 SERIES

LEAD WIRES: Three color coded, minimum 6” wire leads, #16AWG, rated for 105˚C.

APPLICATIONS

CONTACTS: Remain closed between dusk and dawn (the unit fails in the ON position).

2117

Parking lot lighting Building perimeter lighting Outdoor signage

LEAD WIRES: Three color coded, minimum 6” wire leads, #16AWG, rated for 105˚C. (2117 #10AWG red and black).

2115 & 2116

POWER CONSUMPTION: Averages under 1 watt.

POWER CONSUMPTION: Averages under 1 watt.

TEMPERATURE RANGE: -40˚ to +140˚F (-40˚ to +60˚C).

TEMPERATURE RANGE: -40˚ to +140˚F (-40˚ to +60˚C).

FAIL MODE: ON.

FAIL MODE: ON.

WARRANTY: 5 years.

WARRANTY: 5 years.

CONTACT RATINGS

CONTACT RATINGS

RATING CATALOG SWITCH WIRING DIAGRAMS NO. TUNGSTEN BALLAST

FEATURES OPERATION: Delay of up to two minutes to prevent false switching due to light from passing vehicles, lightning, etc.

2101

SPST

2000W

1800VA

2104

SPST

2000W

1800VA

2107

SPST

2000W

1800W

2000 SERIES

HOUSING: Heavy Duty die cast zinc housing and base. Gasketed for maximum weather protection.

WIRING DIAGRAMS

VOLTAGE 50-60Hz

2101

60012

120VAC

2104

60013

208-277VAC

2107

60031

120/277VAC

73866

62020

Mounting Bracket

2100 SERIESDie case aluminum housing HOUSING:

and base. Gasketed for weather protection. 2000 SERIES

SWITCH

2115

RATING TUNGSTEN

BALLAST

SPST

2000W

1800VA

2116

SPST

3470-4620W

2080-2770VA

2117*

SPST

3000W

3000VA

2100 WIRING SERIES

DIAGRAMS

ORDERING INFO

ORDERING INFO UPC CODE

OPERATION: Delay of up to two minutes to prevent false switching due to light from passing vehicles, lightning, etc.

ENERGY SAVINGS: Works with screw base CFLs and LED lamps.

ENERGY SAVINGS: Works with screw base CFLs and LED lamps.

CATALOG NO.

FEATURES

CATALOG NO.

CATALOG NO.

UPC CODE

VOLTAGE 50-60Hz

2115

60032

120VAC

2116

60033

208-277VAC

2117*

60037

120VAC

73866

62020

Mounting Bracket

*Not UL or CSA rated.

PHOTOCONTROLS TORK 13

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

TORK 14

2000 SERIES

SPECIFICATIONS

1/2" CONDUIT MOUNTING FIXED POSITION, LEXAN® HOUSING WITH WEATHERPROOF SEALANT PHOTOCONTROL

ON/OFF: Turn ON is 1 to 5fc. Turn OFF is 3 to 15fc, without the slide in position. ON/OFF adjustment is easily made by moving a slide cover. No tools required.

2001 SERIES

SPECIFICATIONS

1/2" CONDUIT MOUNTING 180° SWIVEL, LEXAN® HOUSING PHOTOCONTROL

ON/OFF: Turn ON is 1 to 5fc. Turn OFF is 3 to 15fc, without the slide in position. ON/OFF adjustment is easily made by moving a slide cover. No tools required.

TIME DELAY: ON and OFF.

TIME DELAY: ON and OFF.

Cadmium sulphide, epoxy-coated, 1⁄2”

CELL: diameter.

APPLICATIONS

CONTACTS: Remain closed between dusk and dawn. (The unit fails in the ON position).

Flood lamp Patio lamp Decorative lighting

LEAD WIRES: Three color coded, minimum 6” wire leads, #16AWG, rated for 105˚C.

CELL: Cadmium sulphide, epoxy-coated, 1⁄2” diameter.

APPLICATIONS

CONTACTS: Remain closed between dusk and dawn. (The unit fails in the ON position).

Flood lamp Patio lamp Decorative lighting

LEAD WIRES: Three color coded, minimum 6” wire leads, #16AWG, rated for 105˚C.

POWER CONSUMPTION: Averages under 1 watt.

POWER CONSUMPTION: Averages under 1 watt.

TEMPERATURE RANGE: -40˚ to +140˚F (-40˚ to +60˚C).

TEMPERATURE RANGE: -40˚ to +140˚F (-40˚ to +60˚C).

FAIL MODE: ON.

FAIL MODE: ON.

WARRANTY: 5 years.

WARRANTY: 5 years.

CONTACT RATINGS RATING CATALOG WIRING DIAGRAMS SWITCH NO. TUNGSTEN BALLAST

FEATURES OPERATION: Delay up to two minutes to prevent false switching due to light from passing vehicles, lightning, etc.

2000

SPST

2000W

1800VA

2000-2

SPST

3470-4620W

2080-2770VA

2000-7*

SPST

2000W

1800VA

HOUSING: All Lexan® enclosures are impact and vandal resistant. Translucent Lexan® Dome prolongs cell life by further screening out ultraviolet rays. Dome and base are ultrasonically welded for maximum strength.

WIRING DIAGRAMS 2000 SERIES

ENERGY SAVINGS: Works with screw base CFLs and LED lamps.

CONTACT RATINGS FEATURES OPERATION: Delay up to two minutes to prevent false switching due to light from passing vehicles, lightning, etc.

CATALOG NO.

SWITCH

2001 2002

RATING TUNGSTEN

BALLAST

SPST

2000W

1800VA

SPST

3470-4620W

2080-2770VA

HOUSING: All Lexan® enclosures are impact and vandal resistant. Translucent Lexan® Dome prolongs cell life by further 2100 SERIES screening out ultraviolet rays. Dome and base are ultrasonically welded for maximum strength.

WIRING DIAGRAMS

Move Slide for Earlier or Later Turn ON

ENERGY SAVINGS: Works with screw base CFLs and LED lamps.

ORDERING INFO

ORDERING INFO

CATALOG NO.

UPC CODE

VOLTAGE 50-60Hz

CATALOG NO.

UPC CODE

VOLTAGE 50-60Hz

2000

60017

120

2001

60015

120

2000-2

60018

208-277

2002

60016

208-277

2000-7*

62023

120/277

73866

62020

Mounting Bracket

73866

62020

Mounting Bracket

• •

Red

Lamp



Move Slide for Earlier or Later Turn ON

•240V L2 • L1

*Model 2000-7 has a cadmium sulphide, 1” epoxy cell. Also UL listed and CSA certified.

Black Line White Neutral

(Black) Line (White)

(Red)



Lamp

For 277VAC: L1 - Line L2 - Neutral

PHOTOCONTROLS TORK 15

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

TORK 16

2020 SERIES

SPECIFICATIONS

1/2" CONDUIT MOUNTING 180° SWIVEL, LEXAN® HOUSING PHOTOCONTROL

ON/OFF: Turn ON is 1 to 5fc. Turn OFF is 3 to 15fc.

ON/OFF: Turn ON is 1 to 5fc. Turn OFF is 3 to 15fc.

CELL: Cadmium sulphide, epoxy-coated, 1⁄2” diameter.

CELL: Cadmium sulphide, epoxy-coated, 1⁄2” diameter.

POWER CONSUMPTION: Averages under 1 watt.

Ideal for applications where it is essential to aim the photocell in an exact direction to sense natural light but avoid artificial light.

FLUSH MOUNTING LEXAN® HOUSING PHOTOCONTROL

TIME DELAY: ON and OFF.

LEAD WIRES: Three color coded, minimum 6” wire leads, #16AWG, rated for 105˚C.

Flood and patio lamps Decorative lighting

SPECIFICATIONS

TIME DELAY: ON and OFF.

CONTACTS: Normally closed (the unit fails in the ON position).

APPLICATIONS

3000 SERIES

CONTACTS: Normally closed (the unit fails in the ON position).

APPLICATIONS Flush Mounting Model 3010

Pole lanterns Lawn lighting Walkways

LEAD WIRES: Three color coded, minimum 6” wire leads, #16AWG, rated for 105˚C. POWER CONSUMPTION: Averages under 1 watt.

TEMPERATURE RANGE: -40˚ to +140˚F (-40˚ to +60˚C).

TEMPERATURE RANGE: -40˚ to +140˚F (-40˚ to +60˚C).

FAIL MODE: ON.

FAIL MODE: ON.

WARRANTY: 5 years.

WARRANTY: 5 years.

CONTACT RATINGS RATING

CATALOG

SWITCH NO. WIRING DIAGRAMS TUNGSTEN

CONTACT RATINGS FEATURES

CATALOG NO.

OPERATION: Delay up to two minutes to prevent false switching due to light from passing vehicles, lightning, etc.

SWITCH

UPC CODE

VOLTAGE 50-60Hz

2021

60024

120

2022

60025

208-277

73866

62020

Mounting Bracket

BALLAST

SPST

2000W

1800VA

2022

SPST

3470-4620W

2080-2770VA

WIRING DIAGRAMS 120V MODELS

ORDERING INFO CATALOG NO.

TUNGSTEN

2021

HOUSING: All Lexan® enclosures are impact and vandal resistant, cover and base are ultrasonically welded for maximum strength. ENERGY SAVINGS: Works with screw base CFLs and LED lamps.

FEATURES

RATING

Line

•Neutral •

(Black) (White)

(Red)

Lamp

L2

HOUSING & MOUNTING: Control housing is weather-resistant molded Lexan® with ultrasonically welded seams. MODEL 3000: Flush mounting through .6875” hole in post lantern or lighting fixture, 3⁄8” NPT, stem 3⁄4” long. Gasket and nut supplied. MODEL 3010: flush mounting into standard, raintight junction box. Includes plate and gasket to fit FS type outdoor junction box. ENERGY SAVINGS: Works with screw base CFLs and LED lamps.



3000

SPST

2000W

1800VA

3002

SPST

3470-4620W

2080-2770VA

3006*

SPST

1500W

1200VA

3010

SPST

2000W

1800VA

WIRING DIAGRAMS 120V MODEL

LAMP LINE BLK 120V

RED

NEUT. WHITE

ORDERING INFO

208-277V MODELS

L1

OPERATION: Delay up to two minutes to prevent false switching due to light from passing vehicles, lightning, etc.

BALLAST

Line



(Black)



(White)

240V Neutral

(Red)



For 277VAC L1 - Line L2 - Neutral

Lamp

CATALOG NO.

UPC CODE

VOLTAGE 50-60Hz

3000

60020

120

3002

60019

208-277

3006*

60026

347

3010

60021

120

208-277V MODEL For 277VAC: L1 - Line L2 - Neutral LINE BLK

LAMP RED

240V WHITE

*CSA certified only.

PHOTOCONTROLS TORK 17

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

TORK 18

5000M SERIES

SPECIFICATIONS

DELAYED RESPONSE UTILITY GRADE MOV SURGE ARRESTOR PHOTOCONTROL

ON/OFF: Turn-ON is 1 to 3 fc. Turn-OFF to Turn-ON ratio is 5 max. TIME DELAY: ON and OFF. CELL: Cadmium sulphide photocell responds to the light spectrum near to that of a human eye. Resists effects of moisture and airborne contaminants.

APPLICATIONS

RELAY: Bi-metal provides positive snap action switching, reducing bounce and prolonging contact life.

For use on streets, highways and other luminaries equipped with locking type receptacles, where most stringent surge protection is needed.

SURGE ARRESTOR: 380 joule MOV (metal oxide varistor) exceeds ANSI and NEMA requirements. LOCKING PRONGS: Solid brass for maximum corrosion resistance and electrical conductivity. TEMPERATURE RANGE: -40˚ to +140˚F (-40˚ to +60˚C).

OPERATION: Delayed response prevents false switching due to light from vehicles or lighting, etc. STANDARDS: Meets ANSI C136.10 including color designations. Also meets EEI NEMA standards.

ON/OFF: Turn-ON is 1 to 3 fc. Turn-OFF to TurnON is 3 average.

QUICK RESPONSE TURN-LOCK MOUNTING PHOTOCONTROL

TIME DELAY: Instant ON/3-5 seconds OFF. CELL: Cadmium sulphide photocell responds to the light spectrum near to that of a human eye. Resists effects of moisture and airborne contaminants.

APPLICATIONS

CONTACTS: Solid brass prongs for maximum corrosion resistance and electrical conductivity.

For use on streets, highways and other luminaries equipped with locking type receptacles, where instant response is required.

SURGE ARRESTOR: 360 joules MOV exceeds NEMA and ANSI requirements. RELAY: Positive snap action switching, reducing bounce and prolonging contact life.

Complies with ANSI C136.10 and EEI NEMA standards.

TEMPERATURE RANGE: -40˚ to +158˚F (-40˚ to +70˚C).

FAIL MODE: ON.

FAIL MODE: ON.

WARRANTY: 3 years.

WARRANTY: 3 years.

CATALOG NO.

LIGHT SENSOR

5001M

RATING TUNGSTEN

BALLAST

1"

1200W

1800VA

5004M

1"

3470-4620W

2080-2770VA

5007M

1⁄2"

2000W 3470-4620W

1800VA 2080-2770VA

HOUSING: Lexan® UV Stabilized, permanent color with UV resistant clear acrylic window. Models 5026M and 5008M with polypropylene dome. Provides high impact, flammability resistance and electrically safe operation.

5008M*

1"

1000W

1800VA

5021M

1⁄2"

2000W

1800VA

ENERGY SAVINGS: Works with screw base CFLs and LED lamps.

5024M

1⁄2"

3470-4620W

2080-2770VA

5026M**

1⁄2"

1000W

1800VA

ORDERING INFO CATALOG NO.

UPC CODE

VOLTAGE 50-60Hz

COLOR

5001M

61012

105-130

Grey

5004M

61013

208-277

Maroon

5007M

61014

105-130/208-285

Blue

5008M*

61017

480

Yellow

5021M

61015

105-130

Grey

5024M

61016

208-277

Maroon

61045

SPECIFICATIONS

CONTACT RATINGS

FEATURES

5026M**

2005A, 2007A & 2008A

347

WIRING DIAGRAMS

2"

2 3/16"

Green

*Not UL listed or CSA certified. **CSA certified only.

Receptacle Surface

2 3/16"

FEATURES STANDARDS: Meets ANSI C136.10 including color designations. Also meets EEI NEMA standards.

CONTACT RATINGS

HOUSING: Polypropylene, UV Stabilized, permanent color with UV resistant clear acrylic window. Provides high impact, flammability resistance and electrically safe operation. ENERGY SAVINGS: Works with screw base CFLs and LED lamps.

RATING

CATALOG NO.

TUNGSTEN

BALLAST

2005A

1000W

1800VA

2007A

1000W

1800VA

2008A*

1000W

1800VA

WIRING DIAGRAMS

ORDERING INFO CATALOG NO.

UPC CODE

VOLTAGE 50-60Hz

COLOR

2005A

62012

105-130

Grey

2007A

62013

105-285

Blue

2008A*

62014

400-550

Yellow

2"

2 3/16" Receptacle Surface

3 3/16"

*Not UL or CSA listed.

N

L1 Line (Black)

N

Load (Red) Neutral (White)

Load

105 to 285 volt single phase grounded supplies and loads

L1 Line (Black)

Load (Red) Neutral (White)

Load

105 to 285 volt single phase grounded supplies and loads

PHOTOCONTROLS TORK 19

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

TORK 20

5200 SERIES

5400 SERIES

SPECIFICATIONS

UTILITY GRADE ELECTRONIC WITH FAIL ON MODE PHOTOCONTROL

SPECIFICATIONS

6000 WATT CONTACTORS WITH TURN-LOCK PHOTOCONTROL

ON/OFF: Turn ON is 1.5 foot candle +/- 0.2 OFF/ON ratio is 1.5:1 average*.

RECEPTACLE: 3-prong turn-lock meets the requirements of EEI NEMA. POWER CONSUMPTION: Maximum 3 watts during daylight.

TIME DELAY: Instant ON/3-5 second OFF*. CELL: Silicon photosensor assures drift-free operation, turning on and off at the same light level consistently throughout the life of the unit.

APPLICATIONS

APPLICATIONS

CONTACTS: DC relay has positive snap action switching, reducing bounce and prolonging contact life. Fail ON for safety.

For use where the extreme accuracy and reliability of an electronic photocontrol is required and in the event of failure, light should stay ON for safety reasons.

CONTACT RATINGS For street lighting. Controls all lighting loads in excess of the capacity of the photoelectric control contacts.

SURGE ARRESTOR: 920 joule MOV (metal oxide varistor) exceeds ANSI and NEMA requirements. LOCKING PRONGS: Solid brass for maximum corrosion resistance and electrical conductivity. POWER CONSUMPTION: 1.0 watt average @ 120V. TEMPERATURE RANGE: -40˚ to +158˚F (-40˚ to +70˚C).

CATALOG NO.

SWITCH

CONTACT RATING PER POLE

5403

DPST

3000W

5404

DPST

3000W

5404-3

DPST

3000W

5420

SPDT

3000W

FAIL MODE: ON.

WIRING DIAGRAMS

WARRANTY: 5 years. *Consult factory for other ratios and time delays.

120 VOLT CIRCUIT MODEL WHT 5403

WHT

LOAD

STANDARDS: Meets ANSI C136.10 including color designations. Also meets EEI NEMA standards. HOUSING: UV stabilized, ANSI colorcoded, high impact polypropylene dome. Cross-linked polypropylene gasket. High impact ABS base. High impact, UV stabilized acrylic window.

CONTACT RATINGS CATALOG NO.

LIGHT SENSOR

5231 5237

TUNGSTEN

BALLAST

Silicon Photosensor

1000W

1800VA

Silicon Photosensor

1000W

1800VA

2"

ORDERING INFO

WHT

78885

105-130VAC

5237

78886

105-305VAC

Line (Black)

Load (Red) Neutral (White)

Load

105-305 VAC single phase grounded supplies and loads

3 1/8"

120V N

120 VOLT CIRCUIT MODEL 5420

105 to 285 volt single phase grounded supplies and loads

CAS DIMENS

RED LOAD 1 BLUE LOAD 2

WHT H 120V

CATALOG NO.

UPC CODE

PHOTOCONTROL INCLUDED

VOLTAGE 50-60Hz

5403

60009

5021M

105-130VAC

5404

60010

120 VOLT CIRCUIT MODEL WHT 5403

5024M

5404-3

60011

5024M

5420

60014

5021M

BLK

LOAD 1 CLOSES AT DUSK, OPENS AT DAWN LOAD 2 CLOSES AT DAWN, OPENS AT DUSK

277 VOLT CIRCUIT MODEL 5404-3

208-240VAC BLK RED

WHT

BLK RED

WHT

WHT

BLK RED

BLK RED

208 or 240 VOLT CIRCUIT MODEL 5404

277VAC LOAD

WHT

LOAD

LOAD

105-130VAC

LOAD

LOAD

LOAD

LOAD

WHT

WHT

WHT

H

H

120V N

120V N

H

H 120V

277V N

120V/240V 3-WIRE SYSTEM

H H

277V/480V 4-WIRE SYSTEM

CASE DIMENSIONS

WHT RED

208V or 240V

208V/240V 4-WIRE SYSTEM

Add photoelectric control dimensions 2" high x 3" diameter

BLK

BLUE LOAD 2

N

Load

277V/48

BLK

RED LOAD 1

Neutral (White)

277V N

120V/240V 3-WIRE SYSTEM

WHT RED

N

L1 Load (Red)

H

H 120V

120 VOLT CIRCUIT MODEL 5420 Line (Black)

LOAD

WHT

H

120V N

120V 2-WIRE SYSTEM

120V 2-WIRE SYSTEM

N

LOAD

WHT

H

ORDERING INFO

L1

Receptacle Surface

VOLTAGE 50-60Hz

5231

N

LOAD

WHT

ENERGY SAVINGS: Works with screw base CFLs and LED lamps.

WIRING DIAGRAMS

2 3/16"

UPC CODE

HOUSING: Outdoor NEMA Type 3R. Beige enamel finish. Two 1⁄2”– 3⁄4” combination KO in bottom.

RATING

ENERGY SAVINGS: Works with screw base CFLs and LED lamps.

CATALOG NO.

BLK RED

FEATURES

WHT H 120V BLK

4-1/2" (114mm)

7-1/4" (184mm)

FEATURES

BLK RED

3-13/32" (87mm)

LOAD 1 CLOSES AT DUSK, OPENS AT DAWN LOAD 2 CLOSES AT DAWN, OPENS AT DUSK

PHOTOCONTROLS TORK 21

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

TORK 22

5737 SERIES

TORK 5737 T Z PHOTO-TIMER ®

SPECIFICATIONS

ON AT DUSK, OFF AT MIDNIGHT ON EARLY MORNING, OFF AT DAWN PHOTO-TIMERS

ON/OFF: Turn ON at dusk is 5.0 foot candle +/- 0.5 OFF/ ON ratio is 1.5:1 average.

THE MOST FLEXIBLE PHOTO-TIMER FOR MAXIMUM ENERGY SAVINGS AND ALL ON/OFF NEEDS!

TIME DELAY: Instant ON/3-5 seconds OFF. CELL: Silicon photosensor Midnight OFF: Allows user to adjust OFF time during the night. OFF time can be set for up to two hours before (for extra energy savings) or up to two hours after midnight. Use to stagger groups of lights to go OFF at different times during the night. Early Morning ON (537TZ only): Allows user to set number of hours after midnight (from 2-10 hours) that lights should turn back ON.

APPLICATIONS Offices Restaurant signage Billboards Landscape and yard lighting

No programming is required, the microprocessor tracks dusk and dawn times and automatically determines midnight, and corrects for Daylight Savings Time. It even re-learns and resets itself after a power outage, so that no maintenance is ever needed.

CONTACTS: DC Relay, normally closed. Provides chatter free operation. Solid brass Prongs for maximum corrosion resistance and electrical conductivity.

Ideal for situations when visible traffic is reduced – lights ON at dusk and OFF at 11pm or later, then on again for early morning illumination.

TEMPERATURE RANGE: -40˚ to +158˚F (-40˚ to +70˚C). FAIL MODE: ON. WARRANTY: 3 years.

PHOTOCONTROL ACCESSORIES

FEATURES

FOR TURN-LOCK CONTROLS

OPERATION: Microprocessor tracks the dusk and dawn times with the seasons and automatically determines midnight, NO PROGRAMMING REQUIRED. Automatically "re-learns" and resets after power outage, eliminating costly maintenance. DST correction built in.

CONTACT RATINGS CATALOG NO.

SWITCH

5737TZ 5737TM

TUNGSTEN

BALLAST

SPST

1000W

1800VA

SPST

1000W

1800VA

2"

ORDERING INFO VOLTAGE 50-60Hz

5737TZ

62010

105-305VAC

62009

DEVICE

CATALOG NO.

5500

5500-OC 2 3/16"

UPC CODE

5500 replaces photocontrol to change light fixture to always ON. 5500-OC replaces photocontrol to change light fixture to always OFF. Durable materials and gasket provide longevity and weatherproof protection.

WIRING DIAGRAMS

ENERGY SAVINGS: Works with screw base CFLs and LED lamps.

CATALOG NO.

REPLACEMENT CAPS

RATING

HOUSING: UV stabilized, ANSI color-coded polypropylene dome. UV stabilized, clear acrylic window. ABS base. Cross-linked, polypropylene gasket.

5737TM

DUSK MIDNIGHTON OFF EARLY MO RNING ON DAWN OFF

The TORK Photo-timer Plus is the most flexible photocontrol ever, operating like a photocontrol AND a time switch! Ideal for retrofit without expensive rewiring. The unit turns the load ON at sunset and can be preset to turn the load OFF up to two hours before or two hours after midnight. It can also be set to turn the load back ON from two to ten hours after midnight and OFF at dawn.

2" Receptacle Surface

3 1/8"

N

Load (Red) Load

61132

DEVICE

Shorting cap 480VAC max 1800 Tungsten 1800VA Ballast Open cap 480VAC max (Black housing)

CATALOG NO.

UPC CODE

DESCRIPTION

2223

61025

Receptacle with Neoprene gasket

RECEPTACLE

RECEPTACLE

120-480V receptacle with color-coded #14 leads, mounting bracket and one mounting screw. DEVICE

120 or 277V 2 3/16"

Line (Black)

105-305 VAC single phase grounded supplies and loads

3 1/8"

61130

DESCRIPTION

L1

Neutral (White)

Receptacle Surface

105-305VAC

N

UPC CODE

RECEPTACLE

120-480V receptacle with color-coded #14 leads, neoprene gasket and two mounting screws.

CATALOG NO.

UPC CODE

DESCRIPTION

2224

61026

Receptacle and mounting bracket

120-480V receptacle with color-coded #14 leads, plastic housing, lock nut (with 1⁄2" NPT) and a mounting bracket. DEVICE

CATALOG NO.

UPC CODE

DESCRIPTION

2421

61021

Receptacle with plastic housing and bracket

L1 Line (Black)

Load (Red) Neutral (White)

Load

105-305 VAC single phase grounded supplies and loads

FOR 240V, N=L2, L1=L1

PHOTOCONTROLS TORK 23

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

TORK 24

ELECTROMECHANICAL TIME SWITCHES

FEATURES QUICK LOOK SERIES

PAGE NO.

CLOCK DIAL

MINIMUM SETTINGS (MINUTES) ON

OFF

SKIP A DAY

MANUAL SUNRISE/ OVERRIDE SUNSET

COMMON FEATURES EASY TO SET DIAL ASSEMBLY Tork’s 24 hour dial assembly allows the user to set the time switch more accurately, easily moving it by hand in small increments. Dial can provide up to 12 ON/OFFs per day with cycles as short as 20 minutes. AM and PM settings are easy to see by the light and dark areas of the dial.

MAX ON & OFF EVENTS PER DAY

RATINGS RESERVE (AMPS) POWER

SWITCH TYPES

29

24 Hour

15

15

Permanent

48

SPST

DPST

1100

31

24 Hour

20

75

Yes

12

SPST

DPST

7000

33

24 Hour

20

75

Yes

Yes

12

SPST

DPST

SPDT

DPDT

3PST

40

Available

7000Z

35

24 Hour

20 or 40 Minute Offset

Yes

Yes

Astronomic

1

SPST

DPST

SPDT

DPDT

3PST

40

Available

TZ

49

24 Hour

20 or 40 Minute Offset

Yes

Permanent by circuit

Astronomic

1

DPDT

3PST

20

Standard

W

43

7 Day

60

120

Yes

Yes

2

DPDT

3PST 4PST

40

Available

TW

47

7 Day

60

120

Yes

Permanent by circuit

2

DPDT

3PST

20

Standard

T900

45

7 Day

60

120

Yes

Permanent by circuit

2 SPDT 3 SPDT

20

Standard

1847A

41

24 Hour

20

75

Yes

1847AZ

41

24 Hour

1847AW

41

7 Day

20 or 40 Minute Offset 60

120

8000

37

24 Hour

15

8000

39

6, 12, 30 & 60 Min.

Varies by dial 6 sec. to 1 min.

WH2

40

24 Hour

20

TORK 27

15

75

Yes

Yes

Yes

Yes

Available

Yes

Photo Control

Astronomic

DPST

DPDT

For applications requiring many ON/OFF cycles per day, captive tabs on this dial tilt in and out just using your fingertip!

TU40

SPST

SPDT

CAPTIVE TABS – DUTY CYCLE DIAL

40

SPRING WOUND RESERVE

40

SPDT

2

12

SPDT, Momentary Contact

10

Available

1

SPDT, Momentary Contact

10

Available

2

SPDT, Momentary Contact

10

Available

48

SPDT

20

30/dial

SPDT

20

12

DPST

40

Available

FIELD UPGRADEABLE ASTRONOMIC DIALS All Tork 24 Hour Time Switches can be upgraded in the field to astronomic operation.

During power outages, precision spring mechanism takes over instantly and automatically. Keeps the mechanism on time up to 16 hours on 24 hour models and up to 24 hours on 7 day models. No resetting is needed after power resumes, and field installation is easy!

ENCLOSED MOTOR Time switch motors are enclosed to protect from dust and damage.

REMOVABLE DOOR Tork time switches feature removable doors to provide easy access for installation and wiring. TORK® Electromechanical Controls are designed and manufactured with components which adhere to the highest industry standards. Trained personnel and in-process quality procedures ensure that every unit meets our strictest quality standards.

TORK 28

TU40 SERIES

UNIVERSAL MULTI-VOLTAGE SAME ON/OFF TIMES EACH DAY 24 HOUR TIME SWITCH

NEW!

MORE WIRING SPACE!

CONTACT RATINGS

SPECIFICATIONS INPUT VOLTAGE: 120/208-240/277VAC, 60Hz (auto detection). TIMING ACCURACY: Line frequency.

VOLTAGE

NO

NC

General Purpose

120-277VAC

40A

30A

Inductive

120-277VAC

30A

15A

Ballast

120VAC 277VAC

30A 20A

10A 10A

Tungsten

120VAC

15A

120VAC 240VAC 120VAC 240VAC

1HP, 30FLA, 90LRA 2HP, 20FLA, 60LRA 720VA 720VA

Resistive

28VDC

20A

Max above 104°F

120-277VAC

30A

TERMINAL RANGE: #8 - #18 AWG. OPERATING TEMPERATURE: -31°F to 116°F (-35°C to +47°C).

APPLICATIONS

POWER CONSUMPTION: 6 watts maximum.

Lighting Pumps Signs Air conditioning Water heaters Fans

RATING

TYPE

ENCLOSURE: Polycarbonate Indoor/Outdoor NEMA 3R or -Y suffix metal indoor NEMA 1 enclosure. Both with lockable hasp standard (see page 153 for enclosure dimensions).

Motor Load Pilot Duty

¼HP, 12FLA, 30LRA ½HP, 12FLA, 33LRA 290VA 360VA

WIRING DIAGRAMS

DTU40 ORDERING INFO FEATURES MULTI-VOLTAGE: Automatic input voltage detection. EASY SET: Real time clock face and day/night markings for setting trippers.

Typical Wiring Diagram, Application Typical Wiring Diagram, 120120/277VAC VAC Application

CATALOG NO.

UPC CODE

TIMER SUPPLY (VAC) 60Hz

DRY CONTACTS (UNPOWERED)

TU40

24000

120/208-240/277

DPDT

TU40-Y

24001

120/208-240/277

DPDT

ENCLOSURE TYPE

Plastic Indoor/Outdoor NEMA 3R Metal Indoor NEMA 1

TIMER SUPPLY H

N

NC

NO

C

NC

LOAD L

N

N

NO

C

LOAD L

N

L

Typical Wiring Diagram, 208-240 VAC Application

SCHEDULING: Minimum ON is setting 15 minutes. Dial has 96 captive trippers.

TIMER SUPPLY H

4 in 1 CONTACTS: DPDT can also wire as SPST, SPDT, & DPST.

N

NC

NO

C

NC

NO

C

LOAD

BYPASS SWITCH: Sets timer to permanent ON, OFF or timer operation.

L1

L2

L1

VACATION MODE: Set timer OFF with no change of tripper settings.

L2

DTWH40

INDICATING LIGHTS: Power ON green and load ON red and LED indicators.

Typical Wiring120 Diagram, 120VAC Typical Wiring Diagram, 120/277VAC Application Typical Wiring Diagram, VAC Application

TIMER

SPECIFICATION WRITER’S GUIDE SUPPLY Furnish and install, where shown, a TORK time switch with 24 hour dial. The Time switch input shall be multi-voltage input 120/208/240/277VAC. Time Switch H N NC NO C NC NO C contacts shall be capable of switching 40 amperes per pole continuously up to 277 volts, and shall be DPDT, covering SPST, SPDT and DPST applications as LOAD96 trippers permits LOAD required. Captive ON/OFF trippers shall accomplish 1-48 operation per day. 15 minutes switching changes. Enclosure shall be Heavy duty lockable plastic Indoor/Outdoor NEMA 3R surface type, finished in beige, with combination 1⁄2”, 3⁄4” knockouts on bottom sides and back. Provisions shall be N L shall be TORK Model TU40_. made for positive padlocking. Terminal shall be capableL of receiving #8-#18N AWGL wire. The TimeN Switch Typical Wiring 208-240 VAC Application Typical Diagram, Wiring Diagram, 240VAC TIMER SUPPLY H

ELECTROMECHANICAL CONTROLS TORK 29

N

NC

NO

C

NC

NO

C

LOAD

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

L1

L2

L1

L2 TORK 30

1100 SERIES

SAME DAY ON/OFF TIMES EACH DAY 24 HOUR TIME SWITCH

SPECIFICATIONS

CONTACT RATINGS

INPUT VOLTAGE: 120 or 208-277 VAC 60 Hz, varies by model.

TYPE

APPLICATIONS Lighting Pumps Signs Air conditioning Water heaters Fans Automatic ON/OFF control when operation is required at the same time every day.

FEATURES SCHEDULING: Minimum ON is setting 20 minutes with a minimum OFF setting of 75 minutes. Dial accommodates up to 12 pairs of trippers. One pair included. MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF automatic operation then resumes.

ELECTROMECHANICAL CONTROLS TORK 31

ENCLOSURE TYPE

CATALOG NO.

UPC CODE

INPUT SUPPLY (VAC) 60Hz

OUTPUT CONTACTS

1101

10011

120

SPST

1101-N

10040

120

SPST

1101-NC

10053

120

SPST

1101-O

10015

120

SPST

Metal Indoor NEMA 1 Noryl® Indoor/Outdoor NEMA 3R Noryl® Indoor/Outdoor w/ clear Lexan® cover Metal Indoor/Outdoor NEMA 3

1101-M

10022

120

SPST

Mechanism

1101-M-IAP

10052

120

SPST

1101-7

10033

347

SPST

1102

10012

208-277

SPST

1102-N

10045

208-277

SPST

1102-O

10046

208-277

SPST

Mechanism and mounting plate Metal Indoor NEMA 1 Metal Indoor NEMA 1 Noryl® Indoor/Outdoor NEMA 3R Metal Indoor/Outdoor NEMA 3

1102-M

10035

208-277

SPST

Mechanism

1103

10013

120

DPST

1103-N

10041

120

DPST

1103-NC

10054

120

DPST

1103-O

10016

120

DPST

Metal Indoor NEMA 1 Noryl® Indoor/Outdoor NEMA 3R Noryl® Indoor/Outdoor w/ clear Lexan® cover Metal Indoor/Outdoor NEMA 3

1103-M

10023

120

DPST

Mechanism

1104

10014

208-277

DPST

1104-N

10042

208-277

DPST

1104-NC

10055

208-277

DPST

1104-O

10017

208-277

DPST

Metal Indoor NEMA 1 Noryl® Indoor/Outdoor NEMA 3R Noryl® Indoor/Outdoor w/ clear Lexan® cover Metal Indoor/Outdoor NEMA 3

1104-M

10014

208-277

DPST

Mechanism

1104-M-IAP

10051

208-277

DPST

Mechanism and mounting plate

Replacement Trippers

Order #P47 for a pair of ON/OFF trippers

Replacement Motor

#101 (120V) & #201 (208-277V) For Astronomic Conversion: Order #Z KIT

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

40A

TERMINAL RANGE: #8 - #14 AWG.

Resistive

OPERATING TEMPERATURE: -40˚ to 165˚F (-40˚ to +74˚C).

Tungsten

120VAC

40A

Inductive

120, 277VAC single phase

20A

Pilot Duty

120 -277VAC

1000VA

Motor

120VAC 240VAC

2HP 5HP

POWER CONSUMPTION: 3 watts maximum.

ORDERING INFO

120 -277VAC single phase 120 -277VAC single phase

General Purpose

TIMING ACCURACY: Line frequency.

CONTACT RATING

VOLTAGE

ENCLOSURE: Lockable hasp. Type varies by model (see page 153 for enclosure dimensions).

40A

Model 1101-7 is 30 AMP inductive at 347 volts and CSA only.

OTHER MOUNTINGS: Intermatic® Adaptor Plate model #IAP allows any 1100 series to fit into an Intermatic case.

WIRING DIAGRAMS 1101 & 1102 (SPST)

1103 (DPST)

M

Removable Bridge

M

L L

1

H

2

X

LOAD

N For separate motor terminals remove bridge from terminals 1 & L.

M

L H H TYPICAL FOR 240V SUPPLY

1

H N H

LOADS

M

1104 (DPST) (Both)

2

X LOAD

2

X

1

Must be same phase H

L

H

1

X

2

LOAD

LOAD

N TYPICAL FOR 277V SUPPLY

Typical for double pole Cut motor lead at 1

SPECIFICATION WRITER’S GUIDE Furnish and install, where shown, a TORK time switch with 24 hour dial. The time switch shall be powered by a self-starting synchronous motor. Time switch contacts shall be capable of switching 40 amperes per pole continuously at 277 volts and shall be SPST (DPST as required). Removable ON/OFF trippers shall make possible automatic operation with a minimum ON period of 20 minutes and a minimum of 75 minutes between one OFF period and the next. Enclosure shall be NEMA 1 surface type, finished in beige enamel, with combination 1⁄2”, 3⁄4” knockouts on bottom, both sides and back. Provision shall be made for positive padlocking. Terminals shall be capable of receiving #8AWG wire. Time switch shall be TORK Model 11_ _ (11_ _–_, etc, to fit requirement).

TORK 32

7000 SERIES

CONTACT RATINGS

SPECIFICATIONS

WITH SKIP-A-DAY FEATURE RESERVE POWER OPTIONAL 24 HOUR TIME SWITCH

TYPE

INPUT VOLTAGE: 120 or 208-277 VAC 60 Hz varies by model. TERMINAL RANGE: #8 - #14 AWG.

Resistive

120 -277VAC single phase 120 -277VAC single phase

OPERATING TEMPERATURE: -40˚ to 165˚F (-40˚ to +74˚C).

Tungsten

120VAC

40A

Inductive

120, 277VAC single phase

20A

Pilot Duty

120 -277VAC

1000VA

Motor

120VAC 240VAC

2HP 5HP

General Purpose

TIMING ACCURACY: Line frequency.

CALIFORNIA Title 24

APPLICATIONS

ASHRAE 90.1

POWER CONSUMPTION: 3 watts, 5 watts for “L” models maximum.

Lighting Heating Pumps Air conditioning Signs

ENCLOSURE: Lockable hasp. Type varies by model (see page 153 for enclosure dimensions).

NEW!

FEATURES NEW!

SCHEDULING: Minimum ON setting is 20 minutes with minimum OFF setting at 75 minutes. Dial accommodates up to 12 pairs of trippers. One pair included. SKIP-A-DAY: Omit operations on any day with a 7-spoke wheel marked with days of week. 3 omitting screws included. MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. OPTIONAL RESERVE POWER: “L” models keep dial on time up to 16 hours during power outage.

ELECTROMECHANICAL CONTROLS TORK 33

CATALOG NO.

UPC CODE

INPUT SUPPLY (VAC) 60Hz

OUTPUT CONTACTS

7100

10001

120

SPST

7102

10002

208-277

SPST

7200

11001

120

DPST

7200-O

10512

120

DPST

7202

11002

208-277

DPST

7202-O

10509

208-277

DPST

7300 7302

12001 12002

120 208-277

3PST 3PST

7120

13001

120

SPDT

7122

13002

208-277

SPDT

7220

14001

120

DPDT

7222

14002

208-277

DPDT

ENCLOSURE TYPE

Metal Indoor NEMA 1 Metal Indoor NEMA 1 Metal Indoor NEMA 1 Metal Indoor/Outdoor NEMA 3 Metal Indoor NEMA 1 Metal Indoor/Outdoor NEMA 3 Metal Indoor/Outdoor NEMA 3 Metal Indoor/Outdoor NEMA 3 Metal Indoor NEMA 1 Metal Indoor NEMA 1 Metal Indoor NEMA 1 Metal Indoor NEMA 1

Metal Indoor NEMA 1 Metal Indoor 7202L 19004 208-277 DPST NEMA 1 Metal Indoor/Outdoor 7300L 19005 120 3PST NEMA 3 Metal Indoor/Outdoor 7302L 19006 208-277 3PST NEMA 3 Metal Indoor 7120L 19007 120 SPDT NEMA 1 Metal Indoor 7220L 19009 120 DPDT NEMA 1 Metal Indoor 7222L 19011 208-277 DPDT NEMA 1 Replacement Order #P49 for a pair of ON/OFF per dial. Additional ON/OFF trippers per Trippers dial order #P47. 3 omitting screws #53005 supplied. Replacement #101 (120V) & #201 (208-277V). For "L" models #36 (120V) & #46 (208-277V). For Astronomic Conversion: Order #Z KIT for 7000 Series. Motor 19003

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

120

40A

WIRING DIAGRAMS 7100 SPST

7200 DPST

7100 SPST

M

M

M

7300 3PST

7200 DPST

L

L

L

2 L

H

H

N

X L

1

2

LOAD

H N H

7120 SPDT

2

X

M X

1

L

LOAD

LOAD

H N H

2 L

3

L

L

L

5 L

6

L

DPST

H

1

LOAD

X L H

A

N

LOAD

B

N

2 1

L H

LOAD

X

LOAD

A

B

N

2H H N H

1

L N

3 LOAD

N

5 LOAD

6 LOAD LOAD

LOAD

7302 3PST

7120Z (SPDT) M

M

X

L

H

H

4

LOAD

L

1

3

M

M M

L

2

N

7220 DPDT (DPST) 7200Z 7220 DPDT

M

X

1

4

L LOAD

N

7120 SPDT

M

2

LOAD

LOAD

LOAD

N

1

7300 3PST

M

M

WITH RESERVE POWER 7200L

40A

OTHER MOUNTINGS: Intermatic® Adaptor Plate model #IAP allows any 7100 and 7200 series (except “L” models) to fit into an Intermatic case.

ORDERING INFO

Automatic ON/OFF control when operation is required at the same time every day, with optional versatility of one to six days omission.

CONTACT RATING

VOLTAGE

5 N

2

2

X

LOAD

L

4

H X

1LOAD LOAD

LOAD

3

LOAD LOAD

2

L

N 5 H

LOAD

N

L

1

3H

2

L

4

H

L

6 LOAD

LOAD

N

1

X

2

H

LOAD

5 N

4

X

LOAD

LOAD

LOAD A

LOAD B

N

H

FOR USE WITH 3 PHASE 4-WIRE N 120/208V SYSTEMS.

SPECIFICATION WRITER’S GUIDE Furnish and install, where shown, a TORK time switch with 24 hour dial and day-omitting device. The time switch shall be powered by a self-starting synchronous motor. Time switch contacts shall be capable of switching 40 amperes per pole continuously at 277 volts and shall be SPST (DPST, 3PST, DPST, SPDT, as required). Removable ON/OFF trippers shall make possible automatic operation with a minimum ON period of 20 minutes and a minimum of 75 minutes between one OFF period and the next. Enclosure shall be NEMA 1 surface type, finished in beige enamel, with combination 1⁄2”, 3⁄4” knockouts on bottom, both sides and back. Provision shall be made for positive padlocking. Terminals shall be capable of receiving #8AWG wire. Time Switch shall be TORK Model 7_ _ _ (to fit requirement). FOR RESERVE POWER (MODELS WITH SUFFIX “L”): Spring-driven reserve shall be provided sufficient to operate the time switch contacts at least 16 hours after power failure. On restoration of power, time switch shall transfer to synchronous motor drive and automatically rewind reserve power unit.

TORK 34

7000Z SERIES

ADJUSTS TO DAILY CHANGES IN SUNSET TIMES!

WITH SKIP-A-DAY FEATURE RESERVE POWER OPTIONAL ASTRONOMIC TIME SWITCH

CONTACT RATINGS

SPECIFICATIONS

TYPE

INPUT VOLTAGE: 120 or 208-277 VAC 60 Hz, varies by model. TERMINAL RANGE: #8 - #14 AWG.

Resistive

120 -277VAC single phase 120 -277VAC single phase

OPERATING TEMPERATURE: -40˚ to 165˚F (-40˚ to +74˚C).

Tungsten

120VAC

40A

Inductive

120, 277VAC single phase

20A

Pilot Duty

120 -277VAC

1000VA

Motor

120VAC 240VAC

2HP 5HP

General Purpose

TIMING ACCURACY: Line frequency.

CALIFORNIA Title 24

APPLICATIONS

ASHRAE 90.1

POWER CONSUMPTION: 3 watts, 5 watts for “L” models maximum.

Parking lots Walkways Outdoor signage Window displays Canopy lighting Landscape lighting

ENCLOSURE: Lockable hasp. Type varies by model (see page 153 for enclosure dimensions).

Automatic ON at dusk, OFF at dawn. Control of outdoor lighting.

42°

ORDERING INFO

SKIP-A-DAY: Omit operations on any day with a 7 spoke wheel marked with days of the week. 3 omitting screws included. MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. OPTIONAL RESERVE POWER: “L” models keep dial on time up to 16 hours during power outage.

CATALOG NO.

7200Z–* 7202Z–* 7300Z–* 7302Z–* 7120Z–*

UPC CODE

INPUT SUPPLY (VAC) 60Hz

** **

120 208-277

** **

120 208-277

**

120

OUTPUT CONTACTS

DPST DPST 3PST 3PST SPDT

ENCLOSURE TYPE

Noryl® Indoor/Outdoor NEMA 3R Noryl® Indoor/Outdoor NEMA 3R Metal Indoor/Outdoor NEMA 3 Metal Indoor/Outdoor NEMA 3 Noryl® Indoor/Outdoor NEMA 3R

WITH RESERVE POWER 7200ZL–*

**

120

DPST

7202ZL–*

**

208-277

DPST

7300ZL–*

**

120

3PST

7302ZL–*

**

208-277

3PST

7120ZL–*

**

120

SPDT

7122ZL–*

**

208-277

SPDT

Replacement Motor

Noryl® Indoor/Outdoor NEMA 3R Noryl® Indoor/Outdoor NEMA 3R Metal Indoor/Outdoor NEMA 3 Metal Indoor/Outdoor NEMA 3 Noryl® Indoor/Outdoor NEMA 3R Noryl® Indoor/Outdoor NEMA 3R

#101 (120V) & #201 (208-277V). For "L" models #36 (120V) & #46 (208-277V)

*Add degrees latitude to complete number (18, 30, 34, 38, 40, 42, or 45). **Consult factory for UPC number.

ELECTROMECHANICAL CONTROLS TORK 35

40A

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

40° H N H

38°

WASHINGTON

OREGON

L

7120Z (SPDT)

M

M

45°

ASTRONOMIC SCHEDULING: Turn ON at sunset and OFF at sunrise daily. OFF time can be set from 8:30PM to 2:30AM. Can be individually offset +/- 20 or 40 minutes from both sunset and OFF times. Available from 18° - 45° northern latitudes.

40A

WIRING DIAGRAMS ASTRONOMIC LATITUDE ZONES 7200Z (DPST) 7302 3PST

FEATURES

CONTACT RATING

VOLTAGE

X

2

UTAH

LOAD

WISCONSIN

KANSAS

L L

3

ILLINOIS

ARIZONA

L

NEW MEXICO

IND

MISSOURI

ARKANSAS

N

L

RHODE ISLAND

H

DELAWARE MARYLAND

VIRGINIA

6

LOAD

LOAD B

1

N

H N H

7302 3PST

FLORIDA

18° HAWAII

LOAD A

N

LOAD

L

2

X

2

LOAD

LOAD

GEORGIA

LOUISIANA

30°

X

H

FOR USE WITH 3 PHASE 4-WIRE 7200Z (DPST) 120/208V SYSTEMS.

MEXICO

1

CONNECTICUT NEW JERSEY

NORTH CAROLINA SOUTH LOAD CAROLINA

ALABAMA

MASS

PENNSYLVANIA

4

OHIO

KENTUCKY

TENNESSEE

MISS TEXAS

NH

WEST VIRGINIA

5 OKLAHOMA

VT

2 NEW YORK

CALIFORNIA

34°

X

1

M

MAINE

IOWA

COLORADO

LOAD

M

MICHIGAN

L

WYOMING NEBRASKA

NEVADA

MINN

SOUTH DAKOTA

IDAHO

1

NORTH DAKOTA

MONTANA

7200Z (DPST)

18° PUERTO

M

7120Z (SPDT)

M

M

RICO

L

L

1

X

L

H N H

LOAD

1

X

2

2

LOAD

3

L

4

5

6 LOAD

X

LOAD A

LOAD B

2 H

H

L L

1

LOAD

LOAD

N

N

N

FOR USE WITH 3 PHASE 4-WIRE 120/208V SYSTEMS.

SPECIFICATION WRITER’S GUIDE Furnish and install, where shown, a TORK time switch with Astronomic dial and day-omitting device powered by a self-starting synchronous motor. Time switch contacts shall be capable of switching 40 amperes per pole continuously at 277 volts and shall be (DPST, 3PST or SPDT) as required. ON operation shall occur automatically at sunset (in city of use). OFF operation shall be adjustable from 8:30 P.M. to 2:30 A.M. in one-half hour increments or at sunrise. Both ON and OFF shall have a range of adjustability of 20-40 minutes before or after sunset and sunrise. Enclosure shall be: DPST or SPDT is NEMA 3R indoor/outdoor – Noryl® – 3PST is NEMA 3 metal indoor/outdoor. Terminals shall be of the pressure type, capable of receiving #8 AWG wire. Time switch shall be TORK Model 7_ _ _Z (to fit requirement). FOR RESERVE POWER (Add Suffix L): Spring driven reserve shall be provided sufficient to operate the time switch contacts for at least 16 hours after power failure. On restoration of power, time switch shall transfer to synchronous motor drive and automatically rewind reserve power unit.

TORK 36

8000 SERIES

CONTACT RATINGS

SPECIFICATIONS

MANY DAILY ON/OFF OPERATIONS PER DAY DUTY CYCLE 24 HOUR TIME SWITCH

INPUT VOLTAGE: 120, 208-277VAC or 480VAC, 60Hz, varies by model. TIMING ACCURACY: Line frequency. TERMINAL RANGE: #8 - #14AWG.

ORDERING INFO ENCLOSURE TYPE

CATALOG NO.

UPC CODE

INPUT SUPPLY (VAC) 60Hz

OUTPUT CONTACTS

8001

70001

120

SPDT

8001-N

70025

120

SPDT

8001-NC

70009

120

SPDT

Metal Indoor NEMA 1 Noryl® Indoor/Outdoor NEMA 3R Noryl® Indoor/Outdoor NEMA 3R w/ clear Lexan® cover

8001-LC/WB

70010

120

SPDT

Mechanism and bracket

8001-O

70029

120

SPDT

8004

70002

208-277

SPDT

8001U

70003

480/120 Trans.

SPDT

NEW!

8001U-N

70014

480/120 Trans.

SPDT

NEW!

8001U-O

70011

480/120 Trans.

SPDT

Metal Indoor/Outdoor NEMA 3 Metal Indoor NEMA 1 Metal Indoor NEMA 1 Noryl® Indoor/Outdoor NEMA 3R Metal Indoor/Outdoor NEMA 3

DUTY CYCLE: Adjustable from 1⁄2, 1, 2, 3, 4, 6, 12, and 24 hours.

24 HOUR WITH 7 DAY OMIT 70005

120

SPDT

8007-O

70012

120

SPDT

8008

70006

208-277

SPDT

NEW!

8007U

70008

480/120 Trans.

SPDT

NEW!

8007U-0

70028

480/120 Trans.

SPDT

Metal Indoor NEMA 1 Metal Indoor/Outdoor NEMA 3 Metal Indoor NEMA 1 Metal Indoor NEMA 1 Metal Indoor/Outdoor NEMA 3

24 HOUR WITH 7 DAY OMIT & RESERVE POWER 8007L

70015

120

SPDT

8008L

70016

208-277

SPDT

Metal Indoor NEMA 1 Metal Indoor NEMA 1

24 HOUR WITH 14 DAY OMIT 8007V

70007

120

SPDT

Metal Indoor NEMA 1

SPDT

Metal Indoor NEMA 1

24 HOUR WITH 14 DAY OMIT & RESERVE POWER 8007VL Replacement Motor

TORK 37

120 or 240VAC 480VAC

20A 20A

Motor

120VAC

3/4 HP

OTHER MOUNTINGS: Intermatic® Adaptor Plate model #IAP allows 8001 & 8004 to fit into an Intermatic case.

WIRING DIAGRAMS

70017

120

M

ALL SPDT MODELS

C L

H

8007

SKIP-A-DAY: Some models include 7 day or 14 day wheel to omit selected days of the week.

ELECTROMECHANICAL CONTROLS

Resistive

ENCLOSURE: Lockable hasp. Type varies by model (see page 153 for enclosure dimensions).

8001-N

FEATURES

OPTIONAL RESERVE POWER: “L” models keep dial on time up to 16 hours during power outage.

CONTACT RATING

POWER CONSUMPTION: 3 watts, 5 watts for “L” models maximum.

For one or multiple daily ON/OFF operations.

SCHEDULING: Minimum ON setting is 15 minutes with minimum OFF setting at 15 minutes. Dial accommodates up to 96 captive tabs.

VOLTAGE

OPERATING TEMPERATURE: -40˚ to 165˚F (-40˚ to +74˚C).

APPLICATIONS Duty cycling Ventilating fans Pumping Irrigation Process control Laboratory experiments

TYPE

120VAC N

NC

NO 2

LOAD 2 CLOSED WITH TAB OUTWARD

LOAD 1 CLOSED WITH TAB INWARD

SPECIFICATION WRITER’S GUIDE The time switches shall be of duty cycle type, capable of programming at 15 minute intervals of the day. Scheduled tabs shall be captive on the dial, and shall be easily set by hand without tools to obtain or to change the desired schedule. The switching condition shall be maintained when adjacent tabs are set alike. The unit shall be powered by a self-starting enclosed 120 (or 208-277) volt synchronous motor capable of continuous accurate operation. The switch mechanism shall be a self-contained unit rated at not less than 20 amps, 120 volts, single pole, double throw, and shall be readily replaceable in the field. FOR 8001 ADD: The time switch shall be similar and equal to Tork Model 8001. FOR 8007 AND 8007V ADD: An omitting device shall be furnished as an integral part of the time switch, to enable the switching operation to be skipped for any preselected day or days of the week. The time switch shall be similar and equal to Tork Model 8007 or (8007V.) FOR 8007L ADD: (Same description as for 8007). The unit shall incorporate an integral electrically wound spring reserve power unit, which shall power the clock mechanism for up to 16 hours on a power failure. The time switch shall be similar and equal to Tork Model 8007L. FOR 8001U: The unit shall be furnished with built-in 480-120V transformer to operate timing motor in parallel with 480 volt load. The time switch shall be Tork Model 8001U.

#101(120V) & #201 (208-277V). For “L” models #36 (120V) & #46 (208-277V)

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

TORK 38

8000 SERIES

SPECIFICATIONS

MULTIPLE ON/OFF CYCLES PER DAY REPEATING VARIABLE CYCLE TIME SWITCH

INPUT VOLTAGE: 120VAC, 60Hz.

APPLICATIONS

24 HOUR WATER HEATER TIME SWITCH

INPUT VOLTAGE: 208 – 250V 60 Hz. TIMING ACCURACY: Line frequency.

TERMINAL RANGE: #8 - #14AWG.

TERMINAL RANGE: #8 - #14AWG.

OPERATING TEMPERATURE: -40˚ to 165˚F (-40˚ to +74˚C).

OPERATING TEMPERATURE: -40˚ to 165˚F (-40˚ to +74˚C).

REPLACEMENT TRIPPERS: #P49 for a pair with one ON and one OFF per dial for additional ON/OFF trippers per dial order #P47. 3 omitting screws #53005 supplied. ENCLOSURE: Indoor NEMA 1 Metal with lockable hasp (see page 153 for enclosure dimensions).

For one or many daily ON/OFF operations.

SPECIFICATIONS

TIMING ACCURACY: Line frequency.

POWER CONSUMPTION: 3 watts maximum.

Duty cycling Ventilating fans Pumping Irrigation Process control Laboratory experiments

WH2

APPLICATIONS

SAVE ENERGY!

POWER CONSUMPTION: 3 watts maximum.

Avoid utility peak rates Turn off when not needed

Automatic ON/OFF control of electric water heaters. Schedules the water heater to turn ON only when needed, avoiding energy waste when hot water is not needed.

ENCLOSURE: Indoor NEMA 1 Metal with lockable hasp (see page 153 for enclosure dimensions).

CONTACT RATINGS CONTACT RATINGS

FEATURES SCHEDULING: 60 captive tabs per dial with minimum ON/OFF settings: – 60 minute dial with 1 minute tabs. – 30 minute dial with 30 second tabs. – 12 minute dial with 12 second tabs. – 6 minute dial with 6 second tabs.

TYPE

VOLTAGE

CONTACT RATING

Resistive

120 or 240VAC 480VAC

20A 20A

Motor

120VAC

3/4 HP

CATALOG NO.

UPC CODE

INPUT SUPPLY (VAC) 60Hz

OUTPUT CONTACTS

TYPE

8601

70034

120

SPDT

60 Minute

8301

70033

120

SPDT

30 Minute

8121

70032

120

SPDT

12 Minute

C L

H

120

SPDT

6 Minute

120VAC N

Replacement For 8601 #102, for 8301 #108, for 8121 #107, and for 8061 #105. Motor Replacement #P49 for a pair with one ON and one OFF per dial for additional ON/OFF Trippers trippers per dial order #P47. 3 omitting screws #53005 supplied.

ELECTROMECHANICAL PHOTOCONTROLS CONTROLS TORK 39

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

NC

TYPE

VOLTAGE

CONTACT RATING

Resistive

208-277VAC

40 A, 10,000W

Replacement Motor

#201 (208-277V)

Replacement Trippers

Order #P47 for a pair of ON/OFF trippers

EXTERNAL MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF automatic operation then resumes.

M

ALL SPDT MODELS

ORDERING INFO

70031

SCHEDULING: Minimum ON is setting 20 minutes with a minimum OFF setting of 75 minutes. Dial accommodates up to 12 pairs. 3 pairs of trippers supplied.

WIRING DIAGRAMS

DUTY CYCLE: Settings of 1⁄60 th of dial speed.

8061

FEATURES

WIRING DIAGRAMS TYPICAL FOR 240 VOLT SUPPLY

ORDERING INFO

NO 2

LOAD 2 CLOSED WITH TAB OUTWARD

CATALOG NO.

UPC CODE

INPUT SUPPLY (VAC) 60Hz

OUTPUT CONTACTS

ENCLOSURE TYPE

WH2

70042

208-250

DPST

Metal Indoor NEMA 1

M

H H

L

1

2

X LOAD

LOAD 1 CLOSED WITH TAB INWARD

TORK 40 40 TORK

1800 SERIES

CONTACT RATINGS

SPECIFICATIONS

FOR MECHANICALLY HELD CONTRACTORS AND LOW VOLTAGE REMOTE CONTROL MOMENTARY CONTACT TIME SWITCH

INPUT VOLTAGE: 120VAC or 208-277VAC, 60Hz, varies by model. TIMING ACCURACY: Line frequency.

TYPE

VOLTAGE

CONTACT RATING

General Purpose

24-277VAC

10A

Pilot Duty

24-277VAC

360VA

TERMINAL RANGE: #12 - #22AWG. OPERATING TEMPERATURE: -40˚ to 165˚F (-40˚ to +74˚C).

APPLICATIONS

CALIFORNIA Title 24

Mechanically-held contactors 3-wire momentary lighting systems Remote station switching

POWER CONSUMPTION: 3 watts, 5 watts for “L” models maximum.

ASHRAE 90.1

ENCLOSURE: NEMA 1 Metal with lockable hasp (see page 153 for enclosure dimensions).

WIRING DIAGRAMS

ORDERING INFO WASHINGTON

FEATURES

CATALOG NO.

SCHEDULING: Choice of three types.

1847A

24 HOUR SKIP-A-DAY: Minimum ON setting is 20 minutes with minimum OFF setting at 75 minutes. Dial accommodates up to 12 pairs of trippers. Omit operations on any day with a 7 spoke wheel marked with days of week.

1848A

UPC CODE

INPUT SUPPLY (VAC) 60Hz

52001 52014

120 208-277

7 DAY SCHEDULING: Minimum ON setting is 1 hour with a minimum OFF setting of 2 hours. Minimum 8 hours between 2 OFF settings. 7 day calendar dial will accomodate up to 2 pairs on ON/ OFF trippers per day - 7 pairs are supplied. MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes.

TORK 41

SPDT SPDT

TYPE

42°

24 Hour

OREGON

NORTH DAKOTA

MONTANA

MINN

MICHIGAN

WYOMING

**

120

SPDT

Astronomic

1847AW

52005

120

SPDT

7 Day

WITH RESERVE POWER 1847AL

52006

120

SPDT

24 Hour

1847AZL*

**

120

SPDT

Astronomic

1847AWL

52010

120

SPDT

7 Day

Replacement Trippers

For 24 hour models order #P49 for a pair ON/OFF per dial. Additional ON/OFF trippers per dial order #P47. 3 omitting screws #53005 supplied. 7 day models order #P69 for 7 pairs of ON/OFF trippers.

Replacement Motor

#101(120V) & #201 (208-277V). For “L” models #36 (120V)

*Add degrees latitude to complete number (18, 30, 34, or 42). **Consult factory for UPC number.

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

MAINE

WISCONSIN

SOUTH DAKOTA

IDAHO

UTAH

IOWA

NEW YORK

KANSAS

34°

IND

COLORADO

PENNSYLVANIA

OHIO

KENTUCKY OKLAHOMA ARIZONA

NEW MEXICO

ARKANSAS

TIMING MOTOR

120VAC, 60HZ

L

TENNESSEE

MASS RHODE ISLAND CONNECTICUT

DELAWARE MARYLAND

VIRGINIA

CLOSE COMMON

N

NEW JERSEY

WEST VIRGINIA

MISSOURI

CALIFORNIA

ON

VT NH

ILLINOIS NEVADA

C

MECHANICALLY-HELD CONTACTOR

NEBRASKA

24 Hour

1847AZ*

OPTIONAL RESERVE POWER: “L” models keep dial on time up to 16 hours during power outage.

ELECTROMECHANICAL CONTROLS

OUTPUT CONTACTS

ON

OPEN

NORTH CAROLINA SOUTH CAROLINA

MISS ALABAMA

TEXAS

ASTRONOMIC SCHEDULING: Turn ON at sunset and OFF at sunrise daily. OFF time can be set from 8:30PM to 2:30AM. Can be individually offset +/20 or 40 minutes from both sunset and OFF times.

OFF

ASTRONOMIC LATITUDE ZONES

OFF

GEORGIA

LOUISIANA

MOMENTARY PUSH BUTTON

MEXICO

30°

FLORIDA

18° HAWAII

18° PUERTO RICO

SPECIFICATION WRITER’S GUIDE Furnish and install, where shown, a Momentary Contact time switch. Time switch shall have dial of the (24 hour with day omitting device) (Astronomic with day omitting device) (7 day calendar) type, which shall be suitable to operate mechanically-held contactor of maximum size. Terminal board shall enable fast and correct installation using screw terminals for up to #12AWG wire. Timing motor terminals shall be completely independent from momentary switching circuit. Spring driven reserve mechanism shall be provided sufficient to operate time switch controls at least 16 hours after power failure. On restoration of power, time switch shall transfer to synchronous motor drive and automatically rewind reserve. Time switch shall include solid state circuit to provide a switch closure not in excess of two seconds on both ON and OFF contactor coil terminals at such times as are set on dial: these settings to be made with removable trippers which can be added and removed without tools (except the astronomic dial). Contactor coil circuits shall be suitable for 10 Amp @ 24-277 VAC, 360 VA. Enclosures shall be NEMA 1 surface (or see other mountings), with provision for positive padlocking. Time switch shall be TORK Model 1847AL, 1848A, (AZL), (AWL).

TORK 42

W SERIES

CONTACT RATINGS

SPECIFICATIONS

DIFFERENT SCHEDULES EACH DAY 7 DAY TIME SWITCH

TYPE

INPUT VOLTAGE: 120 or 208-277VAC, 60Hz, varies by model.

Resistive

TERMINAL RANGE: #8 - #14AWG. OPERATING TEMPERATURE: -40˚ to 165˚F (-40˚ to +74˚C).

CALIFORNIA Title 24

APPLICATIONS

ASHRAE 90.1

Heating Air conditioning Display lighting Ventilating systems Lighted signage Storefront lighting

POWER CONSUMPTION: 3 watts, 5 watts for “L” models maximum.

40A

120VAC

40A

Inductive

120, 277VAC single phase

20A

Pilot Duty

120 -277VAC

1000VA

Motor

120VAC 240 VAC

2HP 5HP

ORDERING INFO CATALOG NO.

UPC CODE

INPUT SUPPLY (VAC) 60Hz

OUTPUT CONTACTS

W100

30001

120

SPST

33001

120

ENCLOSURE TYPE

WIRING DIAGRAMS

W100 (SPST)

W100 (SPST)

SPDT

M

W200 W202

FEATURES

31001 31011

120 208-277

SCHEDULING: Minimum ON setting is 1 hour with a minimum OFF setting of 2 hours. Minimum 8 hours between 2 OFF settings. Models W400A and W402A offer minimum ON/OFF settings of 31⁄2 hours. 7 day calendar dial accommodates up to 2 pairs of ON/OFF trippers per day – 7 pairs are supplied. SKIP-A-DAY: Omit operations on any day. MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF automatic operation then resumes. OPTIONAL RESERVE POWER: “L” models keep dial on time up to 24 hours during power outage.

W222 W300 W300-O W302

34001 34011 32001 32003 32002

120 208-277 120 120 208-277

L

Metal Indoor NEMA 1

L

L

L

L XH N H

LOAD 1

N

2

LOAD

H N H

LOAD

2

X

1

2

H L

N

DPDT

1

LOAD

2

L

5

L

4

5

L

N

H

3PST 3PST

35001

120

4PST

W402A

35002

208-277

4PST

Equipment (4PST) W400A Ground

Equipment Ground

LOAD

LOAD

Clock Motor Supply

3 5

6

7

L

X

1

2

H

2

H

B

X

LOAD

1

LOAD

N

N H

N

L

LOAD

B

N

N

2

3

5

LOAD

LOAD

N

4

L

H 3 LOAD

N

5

4

LOAD

LOAD

H N

W202 (DPST)

1

2

3

4

4

MOTOR

MOTOR

MOTOR L

7

8

8

B

H

1

L

6

H

LOAD

H

5

LOAD

L LOAD

A

2

W202MOTOR (DPST) A

2

X

X

M

M A Motor1 Clock Supply

LOAD

A

LOAD

1

L

H

H

Metal Indoor NEMA 1

1

LOAD

1

H

H

6

W400A (4PST)

Metal Indoor/Outdoor NEMA 3

L

LOAD

N

3PST

M

4

L

6 LOAD

2

3

L

LOAD

3

L

LOAD

2

X

M

W220 (DPDT)

M

M

L X

1

W220 (DPDT)

W120 (SPDT)

W120 (SPDT)

DPDT

W400A

H

L

Typical for 208-240VAC

1

X

LOAD

LOAD 1

X

LOAD

H

2

LOAD

2

LOAD

Typical for 277VAC

H

Typical for 208-240VAC

Typical for 277VAC

B

WITH RESERVE POWER W220L

39009

120

DPDT

W222L

39010

208-277

DPDT

W300L

39005

120

3PST

W302L

39006

208-277

3PST

W400AL

39007

120

4PST

Supply Supply

Metal Indoor NEMA 1

Replacement Trippers

Order #P69 for 7 pairs of ON/OFF trippers except W400 series use #P69i.

Replacement Motor

#101 (120V) & #201 (208-277V). For W400 series units order #101i (120V) & #201i (208-277V). For “L” models order #36 (120V) and #46 (208-277V), except W400 series consult factory.

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

M

M

H

W220

W300 (3PST)

W300 (3PST)

M

M

DPST DPST

W200 (DPST)

W200 (DPST)

M

TORK 43

40A

Tungsten

ENCLOSURE: Indoor NEMA 1 Metal with lockable hasp. Other enclosures include metal Indoor/ Outdoor NEMA 3 with suffix "O" (see page 153 for enclosure dimensions).

W120

ELECTROMECHANICAL CONTROLS

120 -277VAC single phase 120 -277VAC single phase

General Purpose

TIMING ACCURACY: Line frequency.

CONTACT RATING

VOLTAGE

To Load(s) To Load(s)

SPECIFICATION WRITER’S GUIDE Furnish and install, where shown, TORK time switch of the 7 day type, powered by a self-starting synchronous motor, capable of being set for different ON/ OFF times each day of the week, to an operating accuracy of plus or minus 15 minutes of the desired time. Time switch contacts shall be capable of switching 40 amperes per pole continuously at 277 volts and shall be SPST (DPST, 3PST, DPDT, SPDT, 4PST as required). Removable ON/OFF trippers shall make possible automatic operation with a minimum ON period of one hour and a minimum of 2 hours between one OFF operation and the next ON. Models W400 and W402 offer minimum ON and OFF settings of 3.5 hours. Enclosure shall be NEMA 1 surface, finished in baked beige enamel, with combination 1⁄2” - 3⁄4” knock-outs on bottom and both sides. Provision shall be made for positive padlocking. Terminals shall be capable of receiving #8AWG wire. Time switch shall be TORK Model W_ _ _ (to fit requirement). FOR RESERVE POWER (Add suffix L): Spring-driven reserve shall be provided sufficient to operate the Time Switch contacts at least 24 hours after power failure (16 hour reserve power on 4PST models). On restoration of power, time switch shall transfer to synchronous motor driven and automatically rewind reserve power unit.

TORK 44

LOAD

T900 SERIES

INPUT VOLTAGE: 120 or 208-277VAC, 60 Hz, varies by model. TIMING ACCURACY: Line frequency. TERMINAL RANGE: #8 - #14AWG.

APPLICATIONS

TYPE

VOLTAGE

CONTACT RATING

General Purpose

120/277VAC

20A

Motor

120VAC 240VAC

1HP 2HP

OPERATING TEMPERATURE: -40˚ to 165˚F (-40˚ to +74˚C).

CALIFORNIA Title 24 ASHRAE 90.1

Parking lot lighting HVAC Display lighting Security lighting Lighted signage Storefront lighting

CONTACT RATINGS

SPECIFICATIONS

PHOTOELECTRIC & 7 DAY CONTROL COMBO DIFFERENT SCHEDULES EACH DAY RESERVE POWER STANDARD 2 & 3 CIRCUIT LIGHTING CONTROL CENTERS

POWER CONSUMPTION: 5 watts maximum. ENCLOSURE: Indoor NEMA 1 Metal with lockable hasp. Other enclosures include cover for access to by-pass switches with suffix "E" or Indoor/Outdoor NEMA 3 metal with suffix "O" (see page 153 for enclosure dimensions).

Optional "E" cover

Model 2101 supplied with unit.

WIRING DIAGRAMS T930L T930L

T920L T920L

ONLYCIRCUITS CIRCUITS1 1AND AND2 2ARE AREINCLUDED INCLUDEDININT920L T920L ONLY

ORDERING INFO FEATURES

CATALOG NO.

SCHEDULING: CIRCUIT 1: ON automatically at dusk, OFF at individual preset times each day, including skipping days when desired. Unit can be set to turn ON before dawn for early morning lighting. CIRCUIT 2: ON at dusk, OFF at dawn automatically, daily. CIRCUIT 3: Individual daily ON and OFF settings at desired times, including skipping any desired day or days Minimum ON is setting 1 hour with a minimum OFF setting of 2 hours. Minimum 8 hours between 2 OFF settings. 7 day calendar dial will accommodate up to 2 pairs of ON-OFF trippers per day – 7 pairs are supplied. SKIP-A-DAY: Omit operations on any day.

UPC CODE

INPUT SUPPLY (VAC) 60Hz

41033

120

2 SPDT

T920L-E

41034

120

2 SPDT

T920L-O

41035

120

2 SPDT

T930L

41055

120

3 SPDT

T930L-E

41056

120

3 SPDT

T930L-O

41057

120

3 SPDT

Metal Indoor NEMA 1 Metal Indoor NEMA 1 with switch access Metal Indoor/outdoor NEMA 3 Metal Indoor NEMA 1 Metal Indoor NEMA 1 with switch access Metal Indoor/outdoor NEMA 3

ON ON OFF OFF

ON ON OFF OFF

AUTO AUTO

AUTO AUTO

SWITCH TIMETIME SWITCH OFF OFF ON ON

MM

C C

NOTE: NOTE: Contacts 7-12 Contacts 7-12 unpowered. areare unpowered.

RELAY RELAY

PHOTOELECTRIC PHOTOELECTRIC CONTROL CONTROL

ON ON OFF OFF

ON ON OFF OFF

ON ON OFF OFF

AUTO AUTO

AUTO AUTO

AUTO AUTO

NOTE: NOTE: Contacts 4-12 Contacts 4-12 unpowered. areare unpowered.

RELAY RELAY

C C PHOTOELECTRIC PHOTOELECTRIC CONTROL CONTROL

MM

CONTACTOR CONTACTOR CONTROL CONTROL CIRCUIT LINELINE CIRCUIT

RED RED WHITE WHITE BLACK BLACK

L1 L1 OPEN CLOSEOPEN LINELINE CLOSE

1 1

CONTACTOR CONTACTOR CONTROL CONTROL CIRCUIT CIRCUIT

1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12

1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 H 120V H 120V N N 60C 60C LINELINE

TIME TIME SWITCH SWITCH

TO DAWN SAFETY LIGHTS DUSKDUSK TO DAWN SAFETY LIGHTS (PHOTOCELL - PHOTOCELL (PHOTOCELL ON - ON PHOTOCELL OFF) OFF)

NEU.NEU. OPEN OPEN CLOSE CLOSE

H 120V H 120V N N 60C BLACK 60C BLACK LINELINE WHITE WHITE RED RED

2 2

L1 L1 LINELINE OPEN OPEN OPENLINELINE OPEN CLOSE CLOSE CLOSE CLOSE

3 3

1 1

TO DAWN SAFETY LIGHTS DUSKDUSK TO DAWN SAFETY LIGHTS (PHOTOCELL - PHOTOCELL (PHOTOCELL ON - ON PHOTOCELL OFF) OFF)

2 2

NEUNEU OPEN OPEN CLOSE CLOSE

LOAD LOAD

LOAD LOAD

#P69 for 7 pairs of ON/OFF trippers. #36 (120V) #66061

RESERVE POWER: Standard feature on all models keep dial on time up to 24 hours during power outage. NOTE: All models are designed to control a contactor circuit and are not recommended for direct switching of most lighting loads.

TORK 45

ENCLOSURE TYPE

OUTPUT CONTACTS

MANUAL BY-PASS SWITCHES: Single pole, 20 Amps – one per circuit. Factory pre-wired to terminal strip. ON/OFF/AUTO positions for each circuit is independent – will not disturb automatic settings.

ELECTROMECHANICAL CONTROLS

MANUAL CONTROLS MANUAL CONTROLS

MANUAL CONTROLS MANUAL CONTROLS

T920L

Replacement Trippers Replacement Motor Replacement Bypass Switch

ALL3 3CIRCUITS CIRCUITSARE AREINCLUDED INCLUDEDININT930L T930L ALL

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

SPECIFICATION WRITER’S GUIDE T900 SERIES – Furnish and install, where shown, a TORK Photo/Time Control of the 7 Day Calendar dial type, which shall be suitable to operate mechanicallyheld contactor(s). Photo/Time Control shall be pre-wired to a central terminal block which provides connecting terminals for Photocontrol and independent contactor control circuit(s). Time switch shall function to prevent energization of lighting for preset periods each day. Time switch dial shall permit different ON/OFF settings for each day of the week, with provision for omitting selected days. Control shall include pre-wired manual switching for each contactor circuit specified. Enclosure shall be NEMA 1 surface. Photocontrol to be remotely installed in appropriate outside location. It shall be fully temperature compensated and shall provide for time delay of at least 15 seconds to prevent false switching. Photocontrol shall operate control center to energize whenever natural lighting falls below 1.5 - 5.5 foot candles turn on. Spring driven reserve timing motor shall be provided sufficient to operate time switch controls at least 24 hours after power failure. On restoration of power, time switch shall transfer to synchronous motor drive and automatically rewind reserve power unit. FOR DUSK-TO-DAWN LIGHTS: Control shall provide additional contactor circuit to above specifications except that it shall be responsive to Photocontrol only. Tork Model T-920L or equal. FOR PRESET ON/PRESET OFF: Control shall provide for additional contactor circuit to above specification except that it shall be responsive to time switch only. Tork Model T-930L.

TORK 46

TW SERIES

INPUT VOLTAGE: 120 or 208 - 277VAC, 60Hz, varies by model.

TYPE

VOLTAGE

CONTACT RATING

General Purpose

120/277VAC

20A

Motor

120VAC 240VAC

1HP 2HP

TIMING ACCURACY: Line frequency. TERMINAL RANGE: #8 - #14AWG.

CALIFORNIA Title 24

OPERATING TEMPERATURE: -40˚ to 165˚F (-40˚ to +74˚C).

ASHRAE 90.1

APPLICATIONS Heating Air conditioning Display lighting Ventilating systems Lighted signage Storefront lighting

CONTACT RATINGS

SPECIFICATIONS

DIFFERENT SCHEDULES EACH DAY MANUAL BYPASS SWITCHES RESERVE POWER STANDARD 7 DAY TIME SWITCH

POWER CONSUMPTION: 5 watts maximum.

Optional "E" cover

ENCLOSURE: Indoor NEMA 1 Metal with lockable hasp (see page 153 for enclosure dimensions).

WIRING DIAGRAMS MANUAL CONTROLS MANUAL CONTROLS ON ON OFF ON

AUTO

ORDERING INFO FEATURES

CATALOG NO.

UPC CODE

OUTPUT CONTACTS

SCHEDULING: Minimum ON setting is 1 hour with a minimum OFF setting of 2 hours. Minimum 8 hours between 2 OFF settings. 7 day calendar dial accommodates up to 2 pairs of ON-OFF trippers per day – 7 pairs are supplied.

TW-220L

39013

120

DPDT

TW-220L-E

39021

120

DPDT

TW-222L

39014

208-277

DPDT

SKIP-A-DAY: Omit operations on any day.

TW-300L

MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. MANUAL BY-PASS SWITCHES: Single pole, 20 Amps – one per circuit. Factory pre-wired to terminal strip. ON/OFF/AUTO positions for each circuit is independent – will not disturb automatic settings.

TW-302L Replacement Trippers Replacement Motor Replacement Bypass Switch

39016

120

3PST

208-277

3PST

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

1

2

1

#36 (120V) & #46 (208-277V) #66061

3

ON

5

4

5

AUTO

6 6

NOTE: Switching contacts NOTE: are unpowered Switching contacts are unpowered

OFF

OFF AUTO

7

9

8

7

9

8

LINE LOAD LINE LINE LOAD LOAD LINE

N

H N

H

TW300L TW300L

When single line source is When source is used, single jumperline terminals used, jumper terminals 1-5-7-9 and connect all com1-5-7-9 and connect2all commons to terminals and 3. mons to terminals 2 and 3.

LOAD LINE LOAD LINE LOAD

MANUAL CONTROLS MANUAL CONTROLS ON OFF ON

1

2

1

H

3

4

OFF

TW220L TW220L

OFF AUTO

AUTO

TIME SWITCH TIME SWITCH 2 4 3

M M

ON ON

OFF AUTO

AUTO

5 5

6 6

7 7

8 8

CONTACTOR CONTROL CONTACTOR CIRCUIT 9 CONTROL CIRCUIT 9

N

H

NOTE: All models are designed to control a contactor circuit and are not recommended for direct switching of most lighting loads.

TORK 47

Metal Indoor NEMA 1 Metal Indoor NEMA 1 with switch access Metal Indoor NEMA 1 Metal Indoor NEMA 1 Metal Indoor NEMA 1

Order #P69 for 7 pairs of ON/OFF trippers.

RESERVE POWER: Standard feature on all models keep dial on time up to 24 hours during power outage.

ELECTROMECHANICAL CONTROLS

ENCLOSURE TYPE

M

ON

OFF

OFF AUTO

AUTO

TIME SWITCH TIME SWITCH 2 4 3

M

INPUT SUPPLY (VAC) 60Hz

39015

ON

OFF AUTO

N

CONTACTOR CONTROL CONTACTOR CIRCUIT CONTROL CIRCUIT

COMMON OPEN COMMON CLOSE OPEN CLOSE COMMON

COMMON OPEN CLOSE OPEN

Wiring shown is for mechaniWiring shown is for mechanically-held contactors. Use cally-held contactors. CLOSE terminal onlyUse for magCLOSE terminalcontactors only for magnetically-held and netically-held contactors and to control direct loads not toexceeding control direct loads not 2000 watts. exceeding 2000 watts.

CLOSE

SPECIFICATION WRITER’S GUIDE Furnish and install, where shown, a TORK time switch of the 7 day type, capable of being set for different ON/OFF times each day of the week, to an operating accuracy of plus or minus 15 minutes of the desired time. The time switch shall be powered by a self-starting synchronous motor with spring-driven reserve, which shall be sufficient to operate the time switch contacts at least 24 hours after power outage. On restoration of power, time switch shall transfer to synchronous motor drive and automatically rewind reserve power unit. Time switch shall provide for automatic operation with a minimum of one hour between an ON/OFF operation with minimum of four ON/OFF operations per day. ON/OFF operations shall be accomplished by removable ON/OFF trippers on the dial. Time switch contacts shall be capable of carrying a minimum 20 amperes per pole continuously at 277 volts and shall be DPDT or 3PST. Manual switches shall be provided as an integral part of the time switch, one for each pole, and shall permit manual switching to maintained ON or OFF positions until manually returned to AUTOMATIC position. Terminal strip shall be capable of receiving #10AWG wires. Enclosure shall be NEMA 1 surface type, finished in beige enamel, and with 1⁄2” - 3⁄4” combination knock-outs on bottom, both sides and top. Provision shall be made for positive padlocking. (Specify “E” door for manual switches to be accessible when case is locked). Shall be TORK Model TW (to fit switch requirement) or equal in general purpose NEMA 1, (general purpose metal) or (Indoor/Outdoor NEMA 3) enclosure.

TORK 48

TZ SERIES

CONTACT RATINGS

SPECIFICATIONS

MANUAL BYPASS SWITCHES RESERVE POWER STANDARD ASTRONOMIC TIME SWITCH

INPUT VOLTAGE: 120 or 208 - 277VAC, 60Hz, varies by model.

TYPE

VOLTAGE

CONTACT RATING

General Purpose

120/277VAC

20A

Motor

120VAC 240VAC

1HP 2HP

TIMING ACCURACY: Line frequency. TERMINAL RANGE: #8 - #14AWG. OPERATING TEMPERATURE: -40˚ to 165˚F (-40˚ to +74˚C).

CALIFORNIA Title 24

APPLICATIONS

ASHRAE 90.1

POWER CONSUMPTION: 5 watts maximum.

Schools Industrial yards Shop windows Parking lots Highway signs Bridges

ENCLOSURE: Indoor NEMA 1 Metal with lockable hasp and for some models enclosures is Indoor/Outdoor NEMA 3 metal with suffix "O" (see page 153 for enclosure dimensions).

WIRING DIAGRAMS ASTRONOMIC LATITUDE ZONES 45° 42°

ORDERING INFO FEATURES SCHEDULING: Turn ON at sunset and OFF at sunrise daily. OFF time can be set from 8:30PM to 2:30AM. Can be individually offset +/- 20 or 40 minutes from both sunset and OFF times. Available from 18° - 45° northern latitudes. SKIP-A-DAY: Omit operations on any day with a 7 spoke wheel marked with days of the week. 3 omitting screws included. MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. MANUAL BYPASS SWITCHES: Single pole, 20 Amps - one per circuit. Factory pre-wired to terminal strip. ON/OFF/AUTO positions for each circuit is independent, will not disturb automatic settings.

CATALOG NO.

TZ-220L* TZ-220L-O*

UPC CODE

** **

INPUT SUPPLY (VAC) 60Hz

40° OUTPUT CONTACTS

120

DPDT

120

DPDT

TZ-222L*

**

208 - 277

DPDT

TZ-300L*

**

120

3PST

TZ-300L-O* TZ-302L* Replacement Motor Replacement Bypass Switch

** **

120

3PST

208 - 277

3PST

Metal Indoor NEMA 1 Metal Indoor/outdoor NEMA 3 Metal Indoor NEMA 1 Metal Indoor NEMA 1 Metal Indoor/outdoor NEMA 3 Metal Indoor NEMA 1

34°

NOTE: Switching contacts NOTE: are unpowered Switching contacts are unpowered

AUTO WASHINGTON

OREGON

NORTH DAKOTA

MONTANA

MINN

WYOMING

MAINE

WISCONSIN

SOUTH DAKOTA

IDAHO

AUTO

MICHIGAN

NH NEW YORK

NEBRASKA ILLINOIS NEVADA

UTAH

IND

COLORADO KANSAS

PENNSYLVANIA

OHIO

KENTUCKY

ARIZONA

NEW MEXICO

ARKANSAS

TENNESSEE

RHODE ISLAND CONNECTICUT

VIRGINIA

DELAWARE MARYLAND

M

2

1

3

5

4

5

6 6

7 7

9

8

LINE LOAD LINE LINE LOAD LOAD LINE LINE LOAD LOAD LINE LOAD

9

8

N

H

N

H

NORTH CAROLINA SOUTH CAROLINA

MISS ALABAMA

TEXAS

1

MASS

NEW JERSEY

WEST VIRGINIA

MISSOURI

CALIFORNIA OKLAHOMA

M

VT

IOWA

TIME SWITCH TIME 2 SWITCH 4 3

GEORGIA

LOUISIANA

30°

TZ300L TZ300L When single line

sourcesingle is used, When line jumperis terminals source used, 1, 5, 7,terminals 9 and connect jumper 1,all5,commons 7, 9 and toconnect allterminals commons2 and to 3. terminals 2 and 3.

MEXICO FLORIDA

18° HAWAII

MANUAL CONTROLS

18° PUERTO

MANUAL CONTROLS

RICO

M 1 1 H H

M

TIME SWITCH TIME 2 SWITCH 4 3 2

3

4

5 5

6 6

7 7

8 8

9 9

N N

CONTACTOR CONTROL CONTACTOR CIRCUIT CONTROL CIRCUIT

CONTACTOR CONTROL CONTACTOR CIRCUIT CONTROL CIRCUIT

COMMON OPEN COMMON CLOSE OPEN COMMON CLOSE

OPEN COMMON CLOSE OPEN CLOSE

TZ220L TZ220L Wiring shown is for

mechanically Wiring shown isheld for contactors. Use mechanically heldCLOSE terminal only contactors. Usefor CLOSE magnetically held terminal only for contactors and magnetically heldto control direct contactors and loads to not exceeding control direct2000 loadswatts. not exceeding 2000 watts.

#66061

*Add degrees latitude to complete number (18, 30, 34, 38, 40, 42, or 45). **Consult factory for UPC number.

NOTE: All models are designed to control a contactor circuit and are not recommended for direct switching of most lighting loads.

TORK 49

38°

For "L" models #36 (120V) & #46 (208-277V)

RESERVE POWER: Standard feature on all models keep dial on time up to 24 hours during power outage.

ELECTROMECHANICAL CONTROLS

ENCLOSURE TYPE

MANUAL CONTROLS MANUAL CONTROLS

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

SPECIFICATION WRITER’S GUIDE Furnish and install, where shown, a TORK time switch with Astronomic dial and day-omitting device, and a 3-way manual switch for each circuit. The time switch shall be powered by a self-starting synchronous motor with spring-driven reserve, which shall be sufficient to operate the time switch contacts at least 16 hours after power failure. On restoration of power, time switch shall transfer to synchronous motor drive and automatically rewind reserve. ON operation shall occur automatically at sunset in (city of use). OFF operation shall be adjustable from 8:30 P.M. to 2:30 A.M. in one-half hour increments or at sunrise. Both ON and OFF shall have a range of adjustability of 20 or 40 minutes before or after sunset and sunrise. Time switch contacts shall be capable of carrying a minimum of 20 amperes per pole continuously at 277 volts and shall be DPST (3PST). Manual switches shall be provided as an integral part of the time switch, one for each pole, and shall permit manual switching to maintained ON or OFF positions until manually returned to AUTOMATIC position. Terminal strip shall be capable of receiving #10AWG wires. Enclosure shall be NEMA 1 surface type, finished in beige enamel, and with 1⁄2” - 3⁄4” combination knock-outs on bottom, both sides and top. Provision shall be made for positive padlocking. (Specify “E” door for manual switches to be accessible when case is locked). Time switch shall be TORK Model TZ-___ (to fit requirement).

TORK 50

DIGITAL TIME SWITCHES

FEATURES QUICK LOOK DTU40

DTWH40

E-PB

E

EW

EWZ

DG

DGM

DZS

DTS

DWZ

Page No.

55

55

57

57

59

61

63

63

65

67

69

Number of Channels

1

1

1

1 or 2

1 or 2

1 or 2

1 or 2

1

1, 2, or 4

1, 2, or 4

20 (140)

20

20

20

56

56

99

ON/OFF Set Points

7 pair (98) 7 pair (98)

DW

DZM

ELC71/72 ELC74/78/712

Page No.

69

71

73

1

Number of Channels

2

2

99

99

ON/OFF Set Points

99

99

7/365 day

7/365 day

7/365 day

LIGHTING CONTROLS

CYCLE - SIGNAL TIMER

DGU

DGUM

DGLC

DLC400

DG

DGS

DIN

75

79

79

79

81

85

85

89

1 or 2

4, 8, or 12

1

1

1 or 2

4

1 or 2

1

1 or 2

128

128

56

56

56

99

56

56

8 pair 3 pair/ch

7/365 day

7/365 day

24 Hour

7 Day

7 Day

365 Day/7 Day Scheduling

7 day

7 day

24 hour

24 hour

7 day

7 day

Automatic Daylight Savings Adjustment

Manual

Manual

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Automatic Daylight Savings Adjustment

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Leap Year

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

24

24

24

Individual Holiday Schedules

24

24

26

26

10

10

Yes

Yes

Yes

Yes

Leap Year

7/365 day 7/365 day

ENERGY/LIGHTING CONTROLS

Individual Holiday Schedules Block Holiday

9

9

Season Scheduling

Block Holiday 4

Astronomic (Sunrise/Sunset)

Yes

365 Day/7 Day Scheduling 7/365 day 7/365 day

4

Yes

Yes

Season Scheduling

4

Astronomic (Sunrise/Sunset)

Yes

7/365 day 7/365 day 7/365 day 7/365 day

24 9

9

9 4

Yes

Yes

Yes

Photosensor Input

Photosensor Input

Yes

Yes

Yes

Yes

Yes

Yes

Remote Override Input

Remote Override Input

Yes

Yes

Yes

Yes

Yes

Yes

User Defined Input

User Defined Input

Yes

Yes

Signal/Pulse Duration

Yes

Yes

Yes

Yes

Yes

Yes

Signal/Pulse Duration

Yes

Momentary for Contactors

Option

Option

Option

Yes

Yes

Momentary for Contactors

Duty Cycle

Duty Cycle

31 Day Cycle

31 Day Cycle

Yes

Yes

Yes

Manual Override

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Manual Override

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Clock Format

AM/PM

AM/PM

AM/PM

AM/PM

AM/PM

AM/PM

12/24

12/24

12/24

12/24

12/24

Clock Format

12/24

12/24

12/24

12/24

12/24

12/24

12/24

12/24

12/24

12/24

AM/PM

7 day Super Capacitor

7 day Super Capacitor

Power Outage Backup

Permanent

Permanent

Permanent

Schedule Retention without power

Yes

Yes

Power Outage Backup Schedule Retention without power

Rechargeable Rechargeable 4 day Super 4 day Super 4 day Super 4 day Super 7 day Super 7 day Super 7 day Super Battery Battery Capacitor Capacitor Capacitor Capacitor Capacitor Capacitor Capacitor Battery

Battery

Staggered Start

Permanent Permanent Yes

Yes

Permanent Yes

Permanent Permanent Permanent Yes

Yes

Yes

Memory Module Computer Programming Software Output Contacts: Amps Resistive or General Purpose

Staggered Start

Yes

Memory Module

Yes

Computer Programming Software Output Contacts: Amps Resistive or General Purpose Contact Type: Dry Unpowered

40A

40A

30A

40A

40A

40A

20A

20A

30A/20A

30A/20A

30A

Contact Type: Dry Unpowered

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Voltage Input AC

120/208240/277

120/208240/277

120

120-277

120-277

120-277

120-277

120-277

120/208240/277

120/208240/277

120/208240/277

Low Voltage Input (select models) TORK 53

12VDC 24VAC

Voltage Input AC Low Voltage Input (select models)

7 day Super 7 day Super 7 day Super Capacitor Capacitor Capacitor Permanent Permanent Yes

Yes

2 day Capacitor 7 day Super 7 day Super 7 day Super 1 year battery Capacitor Capacitor Capacitor

Capacitor

Battery

Permanent

Permanent

Yes

Yes

Yes

Yes

6 month battery

7 day Super 7 day Super Capacitor Capacitor

Permanent Permanent Permanent Yes

Yes

Yes

Permanent

Yes

Yes

8 year battery Battery

Yes

Yes

Yes

Yes

30A

30A

20A

20A

20A

20A

20A

30A

20A

20A

16A

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

24/120/208 240/ 277

120-277

120-277

120-277

120/208240/277

120-277

120-277

120

12VDC 24VAC

24VAC

120/208- 120/208- 120/208-240/ 240/277 240/277 277

24VAC All Models

TORK 54

DT SERIES

NEW!

AUTOMATIC VOLTAGE DETECTION 24 HOUR OR 7 DAY HOUR TIME SWITCH

MORE WIRING SPACE! NEW!

INPUT VOLTAGE: 120/208-240/277 VAC, 50/60 Hz (auto detection). DTWH40 is 120/240VAC (auto detection).

TYPE

VOLTAGE

Resistive

TERMINAL RANGE: #8 - #18AWG. OPERATING TEMPERATURE: -31°F to 116°F (-35°C to +47°C).

APPLICATIONS DTU40 Pumps, motors, fans Signs and lighting Water heaters Heating and air conditioning

CONTACT RATINGS

SPECIFICATIONS

POWER CONSUMPTION: 6VA Max. ENCLOSURE: DTU40 polycarbonate Indoor/ Outdoor NEMA 3R. DTWH40 polycarbonate indoor NEMA 1 enclosure with clear cover. Both with lockable hasp (see page 153 for enclosure dimensions).

DTU40

DTWH40

DTWH40 Water Heaters This timer turns OFF when rates are high and turns OFF when no one is home.

SAVE ENERGY!

120-277VAC

40A

30A

Inductive

120-277VAC

30A

15A

Ballast

120VAC 277VAC

30A 20A

10A 10A

Tungsten

120VAC

15A

120VAC 240VAC 120VAC 240VAC

1HP/30FLA/90LRA 2HP/20FLA/60LRA 720VA 720VA

Resistive

28VDC

20A

Max above 104°

120-277VAC

30A

Pilot duty

1⁄4HP/12FLA/30LRA 1⁄2HP/12FLA/33LRA

290VA 260VA

Typical Wiring Diagram, Application Typical Wiring Diagram, 120120/277VAC VAC Application TIMER SUPPLY N

NC

CATALOG NO.

UPC CODE

TIMER SUPPLY (VAC) 60Hz

NO. OF CHANNELS

DRY CONTACTS (UNPOWERED)

L

N

DTU40

24004

120/208-240/277

1

DPDT

DTWH40

24005

120/240

1

DPDT

H

NC

N

NO

C

LOAD L

N

NC

NO

C

WIRING DIAGRAMS L1

MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes.

C

N

L

Typical Wiring Diagram, 208-240 VAC Application TIMER SUPPLY

DAYLIGHT SAVING: Manual button push for one hour adjustment.

NO LOAD

ORDERING INFO

SCHEDULING: 7 ON & OFF pairs of set points for individual programs on each day of the week. Minimum setting is 1 minute.

NC

DTU40

H

FEATURES

NO

Motor

Avoid utility peak rates Turn off when not needed

RATING

NC

NO

C

LOAD

L2

L1

L2

DTWH40

DTU40

Typical Wiring120 Diagram, 120VAC Typical Wiring Diagram, 120/277VAC Application Typical Wiring Diagram, VAC Application

EXTERNAL MANUAL OVERRIDE: DTWH40 only on clear door. Override without opening case.

TIMER SUPPLY H

N

TIMER SUPPLY NC

NO

C

NC

LOAD

RANDOM MODE: Varies ON and OFF times to create "lived-in" look when away.

L

CLOCK FORMAT: AM/PM.

Typical Wiring Diagram, Application Typical Wiring Diagram, 120120/277VAC VAC Application

N

N

NO

C

H

L

N

L

TIMER SUPPLY H

N

NC

NO

C

L

N

N

L2

NO

C

LOAD L

N

L

Typical Wiring Diagram, 208-240 VAC Application TIMER SUPPLY

NC

NO

C

NC

NO

C

H

N

NC

NO

C

LOAD L1

NC

LOAD

Typical Wiring 208-240 VAC Application Typical Diagram, Wiring Diagram, 240VAC

POWER OUTAGE BACKUP: Battery retains time and schedule.

N

LOAD

L1

NC

NO

C

LOAD L2

L1

L2

L1

L2

DTWH40 Typical Wiring120 Diagram, 120VAC Typical Wiring Diagram, 120/277VAC Application Typical Wiring Diagram, VAC Application

DIGITAL CONTROLS TORK 55

TIMER SUPPLY H

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

N

NC

NO

C

LOAD L

N

N

NC

NO

C

LOAD L

N

L

TORK 56

E & E-PB SERIES

CONTACT RATINGS

SPECIFICATIONS

BACK-UP WITHOUT BATTERY, ECO FRIENDLY!

MULTIPURPOSE CONTROLS 1 OR 2 CHANNEL 24 HOUR TIME SWITCH

INPUT VOLTAGE: E SERIES 120 - 277VAC, 50/60Hz (automatic detection). E-PB 120VAC, 50/60Hz.

APPLICATIONS

TERMINAL RANGE: #8 - #16AWG.

E101B

Signs Air conditioning Lighting Sump pumps Ventilating fans

OPERATING TEMPERATURE: -40° to +149°F (-40° to +65°C).

1

4CONSUMPTION: 6VA Max. 3 POWER

ENCLOSURE: Plastic Indoor/Outdoor NEMA 3R is standard with lockable hasp (see page 153 for L N N 120/277VAC enclosure dimensions).

2A

120VAC

5A

720VA

720VA

720VA

120-277VAC

470VA

1HP

1HP 11⁄2HP 2HP

1HP 11⁄2HP 2HP

120VAC 240VAC

1HP 2HP

30A

30A

28VDC

20A

30A

Inductive

120-277VAC

40A

30A

30A

Ballast

120VAC 208-277VAC

30A 20A

30A 20A

Tungsten

120VAC

15A

120-277VAC

Pilot Duty

E101B

3

2

120VAC TIMER 5 SUPPLY LOAD 208VAC 240-277VAC

Motor4

LOAD

LOAD

L

15A

30A

SPDT

1

10A 10A

30A 12A 30A 12A 20A 6A

40A

TIMER SUPPLY

Resistive N

N

N

1 28VDC

SPST 11 2HP



2HP

2

3

120/277VAC

E101PB VOLTAGE RATING NO

120/240VAC 277VAC 120/240VAC 277VAC 120VAC 277VAC

120-277VAC

SPST

2

E120B RATING NO NC

VOLTAGE

General Purpose

E120B

TIMER SUPPLY

E101B, E103B, E201B RATING NO

TYPE

TIMING ACCURACY: Line Frequency.

4

30A

E120

TIME SUPP 1

LOAD L

N

N

L

120/277VAC

WIRING DIAGRAMS

E103B

DPST

TIMER SUPPLY

E101B 1

FEATURES SCHEDULING: 20 ON/OFF set points repeat each day. Minimum setting 1 minute.

E101B

UPC CODE

82401

INPUT SUPPLY (VAC) 50/60Hz

120-277

NO. OF CHANNELS

OUTPUT DRY CONTACTS

1

E103B

82411

120-277

1

82406

120-277

1

LEAP YEAR: Automatic Compensation.

E201B

82466

120-277

2

E101PB

82401

120-277

L

1N

N

2

3

L

TIMER SUPPLY

L

1

4

N

E101B

2

3

4

N 5

N

3

1 2 TIMER SUPPLY

SPST LOAD

1

N

120/277VAC

2 N

L

6

TIMER SUPPLY 1 LOAD

E101PB DPST

SPDT TIMER SUPPLY 1

3

2

N

L

2

LOAD

4

3

4

LOAD

5

TIMER SUPPLY

5

6

1

2

L

N

4 N

5

N

3

4

5

120/277VAC

N

2

3

4

5

6

PULSE OFF E201B

E201B ONLY: UNIT MUST BE CONFIGURED FOR TIMER MOMENTARY OPTION.

2

L

N

N

3 TIMER SUPPLY LOAD 1

3

CH 1 SP

4

3

2

LOAD

N

120VAC N

6 TIMER SUPPLY

PULSE ON

1

L

E201B

L

L2

208 OR 240VAC

CH 1 SPST

LOAD

LOAD

1

2

L

N

MOMENTA C

3

4

CH 2 SPST

SUPPLY

N

L

2

SPST

120/277VAC

LOAD

N

N

L

DPST

TIMER SUPPLY

MOMENTARY CONFIGURATION CH 1

L1

6

N

120/277VAC

1 LOAD

N

L N N N 120/277VAC

4DPST 5 LOAD

LOAD

3

L

1

120/277VAC L

N

N

TIMER SUPPLY

LOAD

POWER OUTAGE BACKUP: Permanent schedule retention. Supercapacitor provides 4 days of real time backup.

5

6

E103B

4

3

LOAD

4

120/277VAC

TIMER SUPPLY LOAD

L2

3

2

L

N

SPDT L1

208 OR 240VAC

SPST

1

2

E120B E103B

LOAD

E120B

SPST SPDT

TIMER SUPPLY

1

1

DPST

CH 2 SPST

LOAD

DPST

TIMER SUPPLY

CH 1 SPST

LOAD

120/277VAC

SPST

L

CLOCK FORMAT: AM/PM.

4

5

6

N

L

N

120/277VAC LOAD

PULSE O

E201B O BE CON MOMEN

120/277VAC

120/277VAC

DPST

TIMER SUPPLY

1

E201B

1

2

4

3

5

6

LOAD L

LOAD N

N

N

L

120/277VAC DPST

TIMER SUPPLY

1

2

3

4

5

6

L2

208 OR 240VAC

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

LOAD

2

3

4

5

6

CH 1 CH 2 SPECIFICATION SPST SPST WRITER’S

MOMENTARY CONFIGURATION

TIMER GUIDE CH 1 SUPPLY TIMER E100B only – 1. Furnish and install a TORK digital time switch with (40 Amp SPST contacts, model E101B,E201B) (40 Amp DPST contacts, model E103B) (30 Amp SPDT SUPPLY L1 L2 contacts, model E120B). 2. Unit shall be capable of 20 set points. 3. Unit shall repeat the same schedule each day. 4. (Model E201B ONLY) Unit shall be capable of being LOAD 208 OR 240VAC 1 2 3 4 5 6 4 maintained 5 1 2 6 a 1 channel momentary 5. Unit shall have automatic Daylight Savings Time and Leap Year compensation. 6. Unit shall program in AM/PM a32 channel or LOAD LOAD format. 7. Unit shall have LCD display. 8. Unit shall have permanent schedule retention. 9. Unit real time clock shall be retained by super capacitor for 100 hours in a power failure. 10. Unit shall be capable of manual override ON or OFFL either to thePULSE nextON scheduled event or permanently. 11. Unit shall have a NEMA 3R Indoor/Outdoor PULSE OFF N N L 12. Unit Nshall have Load Status indication. 13. Unit shall have Power Failure indication. 14. To order specify TORK Model E101B (E103B) (E120B) L N plastic enclosure. 120/277VAC E201B ONLY: UNIT MUST 120/277VAC BE CONFIGURED FOR MOMENTARY OPTION. (E201B).

TIMER SUPPLY L1

DPST

TIMER SUPPLY

E103B

MOMENTARY OPTION: For mechanically held contractors: Model E201B only. Configure with simple jumper change for single-channel momentary operation.

TORK 57

TIMER SUPPLY

120/277VAC

E120B

DIGITAL CONTROLS

E201B SPST 6

5

LOAD

DAYLIGHT SAVING: Automatic adjustment (can be omitted). MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes.

4

3

2

ORDERING INFO CATALOG NO.

120/2

1

2

L

N

MOMENTARY CONFIGURATION CH 1

3

4

PULSE ON

5

6

PULSE OFF

TORK 58

EW SERIES

AUTOMATIC DST - SAVES TIME CHANGES TWICE A YEAR

MULTIPURPOSE CONTROL 1 OR 2 CHANNEL 7 DAY TIME SWITCH

SPECIFICATIONS

CONTACT RATINGS

TIMING ACCURACY: Line Frequency.

TYPE

INPUT VOLTAGE: 120 - 277VAC, 50/60Hz (automatic detection). energy

APPLICATIONS

ASHRAE 90.1

Outdoor signs Lighting security Heating and air conditioning

40A

120-277 VAC

30A

30A

Inductive

120-277VAC

40A

120-277 VAC

30A

30A

Ballast

120VAC 208-277VAC

30A 20A

120VAC 208-277VAC

30A 20A

10A 10A

Tungsten

120VAC

15A

120VAC

15A

2A

Pilot Duty

120-277VAC

720VA

120-277 VAC

720VA

720VA

Motor

120VAC 208VAC 240-277VAC

SPST 1HP TIMER 120VAC 11⁄2HPSUPPLY 208VAC 2HP 240-277VAC

1HP 11⁄2HP 2HP

1HP 11⁄2HP 2HP

Resistive

28VDC

30A

30A

POWER CONSUMPTION: 6VA Max. ENCLOSURE: Plastic Indoor/Outdoor NEMA 3R. EW101B Suffix -C plastic clear cover Indoor/Outdoor NEMAEW120B TIMER 3R. Suffix SPST -Y metal Indoor enclosure NEMA 1. All TIMER SUPPLY with lockable hasp (see page 153 for enclosure SUPPLY dimensions). 1 2 3 4 1

2

L

N

SPDT

3

LOAD

4

LOAD

5

EW101B

1

2

30A

N

N

WIRING DIAGRAMS

120/277VAC

ORDERING INFO FEATURES SCHEDULING: 20 ON & OFF set points for individual programs for each day of the week. Minimum setting is 1 minute. DAYLIGHT SAVING: Automatic (can be omitted). LEAP YEAR: Automatic Compensation. MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. CLOCK FORMAT: AM/PM. POWER OUTAGE BACKUP: Permanent schedule retention. Supercapacitor provides 4 days of real time backup.

1

CATALOG NO.

UPC CODE

INPUT SUPPLY (VAC) 50/60Hz

NO. OF CHANNELS

EW101B

82431

120-277

1

SPST

EW103B

82441

120-277

1

DPST

EW120B

82436

120-277

1

SPDT

EW201B

82467

120-277

2

SPST

EW103B-C

82253

120-277

1

DPST

82255

120-277

1

L

EW120B-Y EW201B-Y

82437 82261 82299

120-277 120-277 120-277

1 1 2

EW101B SPST

TIMER SUPPLY

1

2

1

3

N

3

N

120/277VAC

N L

1

CH 2 SPST

2

120/277VAC

3

4 LOAD PULSE OFF

LOAD

N

N

CH 1

1

2

3

4

5

1

2

N

120/277VAC

PULSE ON

L N

N

N

DPST momentary configuration

3

EW103B 4 5 TIMER SUPPLY

6

1

2

DPST

1

4

3

LOAD

CH 1

TIMER SUPPLY

5

2

3

N

LOAD N

L

N

L

4

5

6

6

120/277VAC N

PULSE ON

PULSE OFF

EW201B ONLY: UNIT MUST BE CONFIGURED FOR MOMENTARY OPTION

120/277VAC

N

DPST

TIMER SUPPLY

CH 1

3

1

2

L1

L2

3

4

5

6

DPST

TIMER SUPPLY 4

5

6

LOAD SPECIFICATION 1WRITER’S GUIDE 4 3 5 6 2 208 OR 240VAC EW SERIES – 1. Furnish and installON a TORKPULSE digital OFF time switch with (40 Amp SPST contacts, model EW101B, EW210B) (40 Amp DPST contacts, model EW103B) (30 Amp PULSE L N LOAD LOAD SPDT contacts, model EW120B). 2. Unit shall be capable of 20 set points. 3. Unit shall be capable of a different schedule each day of the week. 4. (Model EW201B ONLY) 120/277VAC EW201B ONLY: UNIT MUST BE CONFIGURED FOR MOMENTARY OPTION Unit shall be capable of being a 2 channel maintained or a 1 channel momentary. 5. Unit shall have automatic Daylight Savings Time and Leap Year compensation. 6. L N N L N Unit shall program in AM/PM format. 7. Unit shall have LCD display. 8. Unit shall have permanent schedule retention. 9. Unit real time clock shall be retained by super 120/277VAC capacitor for 100 hours in a power failure. 10. Unit shall be capable of manual override ON or OFF either to the next scheduled event or permanently. 11. Unit shall have DPST TIMER a NEMA 3R Indoor/OutdoorSUPPLY plastic enclosure. 12. Unit shall have Load Status indication. 13. Unit shall have Power Failure indication. 14. To order specify TORK Model EW101B (EW103B) (EW120B) (EW201B).

1

2

L1

L2

3

4

5

6

6

208 OR 240VAC L

N

L

EW103B

TIMER SUPPLY

CH 2 SPST

5

LOAD

momentary configuration

CH 1 SPST

N

L2

120/277VAC

EW201B

6

LOAD

208 OR 240VAC

5

EW201B ONLY: UNIT MUST BE CONFIGURED FOR MOMENTARY OPTION

L

5 4

6

PULSE ON

CH 2 SPST

LOAD

TIMER SUPPLY

SPST

TIMER 4 5 SUPPLY 2

4

LOAD

120/277VAC

L1

momentary configuration

TORK 59

2

3

2

120/277VAC

CH 1 SPDT

1 L

TIMER SUPPLY

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

3

CH 1

4

N

MOMENTARY OPTION: For mechanically held contractors: Model EW201B only. Configure with simple jumper change for single-channel momentary operation.

DIGITAL CONTROLS

L

N

EW120B EW201B

TIMER SUPPLY

SPDT SPST

2 1

PULSE OFF

EW201B ONLY: UNIT MUST BE

TIM SU 1

L

CH 1 SPST

LOAD

momentary configuration

DPST SPDT

1

EW

120

SUPPLY

4

N

N

EW201B

TIMER TIMER SUPPLY

120/277VAC

L

EW120B-C

3

N

SPDT DPST

LOAD

LOAD

EW103B-Y

2

4

120/277VAC

EW120B EW103B

SPST CH 2 SPST

CH 1 TIMER SPST SUPPLY

L

N

120/277VAC

EW101B

EW201B

OUTPUT DRY CONTACTS

N

3

28LOAD VDC

LOAD L

RATING NO NC

120-277VAC

OPERATING TEMPERATURE: -40° to +149° (-40° to +65°C).

CALIFORNIA Title 24

EW120B VOLTAGE

General Purpose

TERMINAL RANGE: #8 - #16AWG. responsible

EW101B, EW103B, EW201B RATING VOLTAGE NO

LOAD

TORK 60

EWZ SERIES

PREFERRED FOR OUTDOOR LIGHTING

MULTIPURPOSE CONTROL 1 OR 2 CHANNEL, ASTRONOMIC 7 DAY TIME SWITCH

SPECIFICATIONS

CONTACT RATINGS

TIMING ACCURACY: Line Frequency.

TYPE

INPUT VOLTAGE: 120 - 277VAC, 50/60Hz (automatic detection). energy

APPLICATIONS

ASHRAE 90.1

Outdoor signs Lighting security Heating and air conditioning

40A

120-277 VAC

30A

30A

Inductive

120-277VAC

40A

120-277 VAC

30A

30A

Ballast

120VAC 208-277VAC

30A 20A

120VAC 208-277VAC

30A 20A

10A 10A

POWER CONSUMPTION: 6VA Max.

Tungsten

120VAC

15A

120VAC

15A

2A

ENCLOSURE: Plastic Indoor/Outdoor NEMA 3R

Pilot Duty

120-277VAC

720VA

120-277 VAC

720VA

720VA

Motor

120VAC 208VAC 240-277VAC

1HPTIMER SUPPLY 11⁄2HP 2HP

SPST 120VAC 208VAC 240-277VAC

1HP 11⁄2HP 2HP

1HP 11⁄2HP 2HP

Resistive

28VDC

28 VDC

30A

30A

is standard with lockable hasp (see page 153 forEWZ120 EWZ101 SPST enclosure dimensions).

Suffix -MB without enclosure TIMER and includes mounting bracket. SUPPLY

SPDT

TIMER SUPPLY

1

2

3

4

1

2

3

LOAD

4

LOAD

5

LOAD L

N

N

120/277VAC

L

WIRING DIAGRAMS120/277VAC

SCHEDULING: 20 ON & OFF set points for individual programs for each day of the week. Minimum setting is 1 minute. ASTRONOMIC: Adjustable 10° - 60° Northern or Southern latitudes. Can be individually offset +/- 1-240 minutes from both sunset and sunrise times. DAYLIGHT SAVING: Automatic (can be omitted). LEAP YEAR: Automatic Compensation. MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes.

CATALOG NO.

UPC CODE

INPUT SUPPLY (VAC) 50/60Hz

1

NO. OF CHANNELS

82470

120-277

1

SPST

EWZ103

82473

120-277

1

DPST

EWZ120

82471

120-277

1

SPDT

EWZ201

82472

120-277

2

SPST

120-277

1

82269

120-277

1

DPST

EWZ120-MB

82275

120-277

1

SPDT

EWZ201-MB

82281

120-277

2

SPST

TIMER SUPPLY

2

1

3

SPST

EWZ103-MB

SPST

2

1 L

N

CH 2 SPST

POWER OUTAGE BACKUP: Permanent schedule retention. Supercapacitor provides 4 days of real time backup. MOMENTARY OPTION: For mechanically held contactors: Model EWZ201 only. Configure with simple jumper change for single-channel momentary operation. momentary configuration CH 1

TIMER SUPPLY

TORK 61

3

4 LOAD PULSE OFF

1

N

L1

5

2

3

4

5

2

3

TIMER SUPPLY

L

N

PULSE ON

L N

CH 2 SPST

LOAD

N

N

DPST

EWZ103 4

5

6

4

5

L2

1

2

4

3

LOAD

CH 1

TIMER SUPPLY

DPST

5

1

2

LOAD L

N

3

N

N

L

4

5

6

6

120/277VAC L

N

N

PULSE ON

PULSE OFF

EWZ201 ONLY: UNIT MUST BE CONFIGURED FOR MOMENTARY OPTION

120/277VAC DPST

TIMER SUPPLY

1

2

3

4

5

6

6

L1 L2 4 3 5 6 1 2 SPECIFICATION WRITER’S GUIDE LOAD 208 OR 240VAC EWZ SERIES – 1. Furnish and install TORK digital time switch with (40 AMP contacts, models EWZ101, EWZ201) (40 Amp DPST contacts, model EWZ103) (30 AMP PULSE ON PULSE OFF LOAD LOAD L N contacts, model EWZ120). 2. Unit shall be capable of 20 set points. 3. Unit shall be capable of a different schedule for each day of the week. 4. Unit shall be have 120/277VAC EWZ201 ONLY: UNIT MUST BE CONFIGURED FOR1°MOMENTARY OPTION astronomic option adjustable from 60° northern or southern latitudes. 5. Unit shall be have astronomic option with offset up to 4 hours and 59 minutes, before or L N N L N after sunrise. 6. (Model EWZ201 ONLY) Unit shall be capable of being a 2 channel maintained or a 1 channel momentary. 7. Unit shall have automatic Daylight Savings 120/277VAC Time and Leap Year compensation. 8. Unit shall program in AM/PM format. 9. Display shall be of LCD type. 10. Unit shall have permanent schedule retention. 11. Unit DPST TIMER real time clock shall beSUPPLY retained by capacitor for 100 hours in a power failure. 12. Unit shall be capable of manual override ON or OFF either in the next scheduled event or permanently. 13. Unit shall have NEMA Type 3 indoor/outdoor enclosure as standard. 14. Unit shall have Load Status indication. 15. Unit shall have Power Failure indication. 16. To order1specify 4 3 Model EWZ101 5 (EWZ103) 6 (EWZ120) (EWZ201). 2 TORK

6 L2

PULSE OFF

EWZ201 ONLY: UNIT MUST BE CONFIGURED FOR MOMENTARY OPTION

TI SU 1

L

5

LOAD

DPST

208 OR 240VAC 120/277VAC

3

208 OR 240VAC

CH 1 EWZ103

L1

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

LOAD

N

TIMER SUPPLY

1

2

6

LOAD

TIMER SUPPLY

momentary configuration

CH 1 SPST

N

5 4

EW

120

CH 1 SPST

6

2

N

momentary configuration

CH 2 SPST

SPST

120/277VAC

EWZ201

4

LOAD LOAD

N

1

EWZ201 ONLY: UNIT MUST BE CONFIGURED FOR MOMENTARY OPTION

L

120/277VAC

3

TIMER SUPPLY

SPDT CH 1

PULSE ON

N

120/277VAC N

CLOCK FORMAT: AM/PM.

DIGITAL CONTROLS

3 2

L N 120/277VAC

EWZ120 TIMER SUPPLY 4 5

N

EWZ201

120/277VAC

EWZ201 3

L

4

LOAD

DPST SPDT

CH 1

4 LOAD

L

2 1

L

N

momentary configuration

TIMER SUPPLY

3

SUPPLY

1

4

N

2

120/277VAC

TIMER TIMER SUPPLY

120/277VAC

EWZ101

1

30A

N

LOAD L

1

82263

3

OUTPUT DRY CONTACTS

EWZ101

EWZ101-MB

2

EWZ101

EWZ120 EWZ103 SPST CH 2 SPST

CH 1 TIMER SPST SUPPLY

ORDERING INFO

N

N

EWZ101

EWZ201

FEATURES

RATING NO NC

120-277VAC

OPERATING TEMPERATURE: -40° to +149° (-40° to +65°C).

CALIFORNIA Title 24

EWZ120 VOLTAGE

General Purpose

TERMINAL RANGE: #8 - #16AWG.

responsible

EWZ101,EWZ103, EWZ201 RATING VOLTAGE NO

LOAD

TORK 62

DG100 SERIES MULTIPURPOSE CONTROLS 1 OR 2 CHANNEL 365/7 DAY TIME SWITCH

HOLIDAY PROGRAMMING FOR MORE SAVINGS!

NEW!

SPECIFICATIONS

CONTACT RATINGS

TIMING ACCURACY: Line Frequency.

TYPE

VOLTAGE

NO

NC

Resistive

24-277VAC

20A

10A

Ballast

120 VAC 277 VAC

20A

10A

Tungsten

120VAC

15A

INPUT VOLTAGE: 120 - 277VAC, 50/60Hz (automatic detection). TERMINAL RANGE: #12 - #18AWG.

APPLICATIONS

OPERATING TEMPERATURE: -31° to +131°F (-35° to +55°C).

CALIFORNIA Title 24

Pilot Duty

POWER CONSUMPTION: 6VA Max.

ASHRAE 90.1

Indoor/Outdoor lighting HVAC equipment School warning and other Traffic lights Water heaters in offices, churches and factories

Motor

ENCLOSURE: Noryl® Indoor/Outdoor NEMA 3R. Suffix -Y metal indoor enclosure NEMA 1. All with lockable hasp (see page 153 for enclosure

Resistive

120VAC 240VAC 120VAC 240VAC 28VDC

RATING

1HP 2HP

290VA 360VA 1⁄4HP 1⁄2HP

20A

10A

720VA

dimensions).

WIRING DIAGRAMS DGM100A

DG200A

ORDERING INFO CATALOG NO.

UPC CODE

INPUT SUPPLY (VAC) 50/60Hz

NO. OF CHANNELS

OUTPUT CONTACTS

SCHEDULING: 56 ON & OFF set points provide individual programs for each day of the week. Minimum setting is 1 minute.

DG100A

82201

120-277VAC

1

DPDT

DG200A

82209

120-277VAC

2

SPDT

MOMENTARY CONTACT: DGM100A has 2 second contact closures for ON & OFF control of mechanically held contactors or latching relays.

DGM100A

82210

120-277VAC

1

DGM100A-Y

82222

120-277VAC

1

SPDT Momentary SPDT Momentary

FEATURES

BLOCK HOLIDAY: 9 holiday blocks can be set for individual days or for duration of any number of days.

DG100A

DAYLIGHT SAVING: Automatic adjustment (can be omitted). LEAP YEAR: Automatic Compensation. MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. CLOCK FORMAT: AM/PM or 24 Hour format.

SPECIFICATION WRITER’S GUIDE DG100/200A SERIES – 1. Furnish and install, where noted, a 1 (2) channel 7-day programmable digital time switch. 2. Controller shall program in AM/PM (12 hour) or Military (24 hour) formats. 3. Unit shall be capable of switching 20 amps ballast loads at 277VAC. 4. Controller shall be capable fo 56 set points; separate scheduling for each day of the week with one minute resolution. 5. Controller shall have 365 day holiday capabilities with 9 block holidays for individual or duration of any number of days. 6. Controller shall be able to select USA Standard Daylight Saving, Standard time, or programmable dates. 7. Controller shall have automatic Leap Year correction. 8. Controller shall have Permanent Schedule Retention. 9. Controller shall have 7 days backup for real time with built in super capacitor; no batteries to maintain. 10. Controller shall be capable of Manual Override ON or OFF to the next scheduled event using 1 button for each channel. 11. Unit shall have NEMA Type 3R indoor/outdoor enclosure as standard. 12. To order specify TORK Model DG100A (DG200A). 13. To order momentary contact closure for latching contactor control specify DGM100A.

POWER OUTAGE BACKUP: Permanent schedule retention is provided. Supercapacitor provides 7 days of real time back up.

DIGITAL CONTROLS TORK 63

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

TORK 64

DZM200B

DZS SERIES

REMOVABLE MEMORY MODULE FOR COMPUTER PROGRAMMING!

MULTIPURPOSE CONTROLS 1, 2 OR 4 CHANNEL 365 / 7 DAY ADVANCED TIME SWITCH

SPECIFICATIONS N

GND NO

UPPER BOARD

TIMER SUPPLY

C

ON

L

energy

APPLICATIONS

CALIFORNIA Title 24

HVAC equipment Horns and bells Interior lighting Electric motors Outdoor lighting and signs

N

PULSE ON

208-240V

INPUT VOLTAGE: 120/208-240/277VAC, 50/60Hz. 277V

N

SCHEDULING: 99 ON & OFF set points allow individual programs for each day of the week at a minimum 1 minute apart.

NO. OF CHANNELS

DRY CONTACTS (UNPOWERED)

DZS100BP

82182

120/208-240/277

1

DPDT

DZS200BP

ASTRONOMIC: Adjustable 10˚ - 60˚ Northern or Southern latitudes can be individually offset +/-1 to 240 minutes from both sunset and sunrise times.

DZS400BP USB-MMP

82183 82184

120/208-240/277 120/208-240/277

2

120

4 Memory Module Programmer

82196

SPDT

82215

120/208-240/277

1

DPDT

HOLIDAYS: 1 to 24 individual dates.

DZS200BP-0

82227

120/208-240/277

2

SPDT

SIGNAL/PULSE DURATION: 2 different settings per channel: 1-99 seconds.

DZS200BP-12

82228

12VDC

2

SPDT

DZS200BP-24

82229

24VAC

2

SPDT

DAYLIGHT SAVING: Automatic adjustment (can be omitted). LEAP YEAR: Automatic Compensation.

82230

120/208-240/277

4

SPDT

NC

24-277VAC

30A

30A

24-277VAC

20A

Ballast

120VAC 277VAC

30A 20A

10A 10A

120-277VAC

13A

Tungsten

120-277VAC

15A

2A

NO C

NC

L

L LOAD

N

277V

GND NO

Motor Load

C

NC

NO

C

C

N

120 208-240

120-277VAC

Resistive

28VDC120V

N

720VA

120 208-240277

30A

L

ON

OFF

C

12-277VAC

30A

1HP

ON

PULSE OFF

OFF

720VA 720VA

PULSE ON

PULSE OFF

N

AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE

1HP

L

PULSE ON

208-240V

8A CH 2

120-277VAC

720VA

20A

N

MECHANICALLY HELD CONTACTORS OR LATCHING RELAYS

LOAD NO NC N

277

CH 1 SPDT L

208-240V

C

TIMER SUPPLY

Pilot Duty

120VAC CH 1

1HP 2HP

277V

L

LOADNC NO

1HP 2HP

208-277VAC

NC

CH 2 SPDT L

WIRING DIAGRAMS AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE

CH 4 SPDT

CH 1 SPDT

C

120VAC DZM200B

N

120V

CH 2 SPDT

L LOAD

277V

LOAD

N

NO C

TIMER SUPPLY

LOWER BOARD

N

NC

NO C

NC

DPDT N

120

208-240 277

L

120V

C

208-240V SUPPLY AC LINE INPUT TIMER SELECT PROPER TERMINALS 277V AND APPLY ONLY ONE VOLTAGE

DZS100BP

120

L

LOAD N

NO NC

C

CH 3 SPDT

LOAD N

NO NC

208-240 277

UPPER BOARD

120V

L

208-240V

AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE

L LOAD

277V

LOAD

N

CH 1 SPDT

C

TIMER SUPPLY

DZS200BP

120 208-240

C

C

NO NC

TIMER SUPPLY

LOAD

277V

MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. In signal mode, activates pulse.

LOAD

N

N

NC

N

NO C

CH 2 SPDT

NC

NO C

NC

LOWER BOARD 120

208-240 277

L

120V

L

C

L

CH 1 SPDT

N

L

NO

LOAD

N

277

208-240V

NC

L

CH 2 SPDT

NO NC

CH 4 SPDT

LOAD

120V

AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE

GND NO

N

DZS400BP

N

DZS400BP-0

General Purpose

PULSE OFF

CH 2 SPDT

N

LOAD

UPPER BOARD

Includes software

DZS100BP-0

N

CH 3 SPDT

N

SEASONS: 1 to 4 with different daily schedules which can wrap around into the new year.

DZS400BP RATING VOLTAGE NO NC

208-240 277

208-240V

N

SPDT

PULSE ON

NO C

TIMER SUPPLY

TIMER SUPPLY (VAC) 50/60Hz

DZS100BP, DZS200BP RATING VOLTAGE NO NC

TYPE

MECHANICALLY HELD CONTACTORS OR LATCHING RELAYS

ENCLOSURE: Noryl Indoor/Outdoor NEMA 3R. Suffix -0 metal Indoor/Outdoor NEMA 3. All with lockable hasp (see page 153 for enclosure dimensions). DZS400BP DZS200BP

UPC CODE

CONTACT RATINGS

LOAD

120V

®

CATALOG NO.

NC

L

CH 1 SPDT

POWER CONSUMPTION: 5VA Max: DZS100/200BP. 6VA Max: DZS400BP.

FEATURES

OFF

LOWER BOARD

OPERATING TEMPERATURE: -40° to +158°F (-40° to 70°C).

ORDERING INFO

C

ON

PULSE OFF

N

TIMER SUPPLY

AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE

ASHRAE 90.1

NO

C

LOADL

AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE

responsible

NC

L

120 208-240277

120V DZS400BP TIMING ACCURACY: Line frequency.

TERMINAL RANGE: #14-#16AWG for line input. #12-#16AWG load outputs.

C

OFF

AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE

LOAD

208-240V

N

277V

L LOAD N

DPDT

TIMER SUPPLY

DZS100BP

CLOCK FORMAT: AM/PM or Military time. POWER OUTAGE BACKUP: Permanent schedule retention with memory module. Supercapacitor provides 7 days of real time backup.

C

NO NC

C

NO NC

SPECIFICATION WRITER’S GUIDE CH 1 CH 2 L DZS SERIES – 1. Furnish and install, where noted, a 4L (2) (1)LOAD channel digital time switch with portable Memory Module on front panel.SPDT 2. MemorySPDT Module shall be LOAD capable of being programmed at any one location and inserted into DZS100BP, 200BP, 400BP Series (with memory module socket) in any other remote location. N N C NO C NO NC 3. Optional programmer shall be available (Model MMP), capable of accomplishing Windows based settings on a PC for easy duplication of NC Memory Modules or DZS200BP individualized programs for multiple locations 4. Unit shall have copy feature: Can be configured to copy program schedules from one memory module to another without use of the optional memory module programmer. 5. Controller shall program in AM/PM (12 hour) or Military (24 hour) formats. 6. Controller shall program in L one minute resolution. 7. Display shall be of LCD type. 8. Controller shall be capable of 99 set points; separate scheduling for each day ofLOAD theL week. LOAD 9. Controller shall N N have 365 day holiday capabilities with 24 single dates and 4 seasons of unlimited duration. 10. Different daily schedules shall be programmable within each season. 11. Controller shall have Daylight Saving or Standard time. 12. Controller shall have automatic Leap Year correction. 13. Controller shall haveDPDT Permanent Schedule Retention. 14. Controller shall have 7 day backup for real time with built in super capacitor. 15. Controller shall be capable of manual override ON or OFF to the next Scheduled event using 1 button for each channel. 16. Unit shall have NEMA Type 3 indoor/outdoor enclosure as standard. 17. Controller shall C NO NC beC capable NO NCof having 2 different pulse durations 1-99 seconds, user settable and assignable to each channel. DZS100BP 18. Controller shall be capable of having astronomic on one (or all) channels with 1-240 minutes, plus or minus offset from Sunrise or Sunset. 19. Controller shall be capable of being configured to copy to multiple memory modules. 20. To order L L specify TORK Model DZS100BP (DZS200BP) (DZS400BP). LOAD LOAD N

120

208-240 277

120V

AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE

208-240V

277V

TIMER SUPPLY

MEMORY MODULE: Removable MM can be programmed at any one location and inserted into another DZS series unit.

N

COPY FEATURE: Unit can be configured to copy program schedule to multiple memory modules. OPTION: Memory Module Programmer with software for computer connection programming. Also allows stand alone battery operation for portable copy feature.

TORK 65

277

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

208-240V

AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE

277V

TIMER SUPPLY

N

120

208-240 277

120V

AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE

DIGITAL CONTROLS

120 208-240

120V

208-240V

277V

N

N

TORK 66

L

DTS SERIES

MAINTAINED AND SIGNAL TIMING

MULTIPURPOSE CONTROLS 1, 2 OR 4 CHANNEL 365 / 7 DAY ADVANCE TIME SWITCH

DTS400B SPECIFICATIONS

Indoor and outdoor lighting Heating and air conditioning Security systems Horns and bells Low voltage lighting Misting and spraying Roof cooling Clock correction systems Process functions

CH 2 SPDT

NO C

TIMER SUPPLY

N

120

NC

LOAD

POWER CONSUMPTION: 6VA Max.

UPPER

GND NO

ENCLOSURE: Noryl® Indoor/Outdoor NEMABOARD 3R with lockable hasp (see page 153 for enclosure dimensions).

CH 1 SPDT

NO

L

DTS400B

N

120

13A

15A

2A

120VAC

8A

120-277VAC

Pilot Duty

120-277VAC

Motor Load

120VAC 208-277VAC

1HP 2HP

1HP 2HP

28VDC

30A

30A

C

NC

Resistive

720VA 720VA

12-277VAC

720VA 720VA

120-277VAC

1HP

1HP

L

N

NO NC

C

NO NC

CH 1 SPDT

WIRING DIAGRAMS

120-277VAC

20A

LOAD

N

C

TIMER SUPPLY

DTS200B

10A 10A

Tungsten

CH 2 SPDT

LOAD

30A 20A

120VAC 277VAC

CH 4 SPDT

NC

20A

Ballast

LOAD

C

24-277VAC

30A

N

CH 3 SPDT

30A

24-277VAC

L

N

277V

RATING NO NC

General NC Purpose

NO C

L

208-240V

DTS400B VOLTAGE

VOLTAGE

208-240 277

120V

DTS100B, DTS200B RATING NO NC

TYPE

TIMING ACCURACY: Line Frequency.

OPERATING TEMPERATURE: -40° to +149° (-40° to +65°C).

ASHRAE 90.1

CONTACT RATINGS

N CH 1 SPDT

TERMINAL RANGE: AC LINE INPUT #14 - #16AWG for lineSELECT input. PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE #12 - #16AWG load outputs.

CALIFORNIA Title 24

LOAD

N

INPUT VOLTAGE: 120/208-277VAC, LOWER 50/60Hz. BOARD

APPLICATIONS

L

LOAD

CH 2 SPDT

208-240 277

120V

208-240V TIMER SUPPLY

AC LINE INPUT SELECT PROPER TERMINALS LOWER AND APPLY ONLY ONE VOLTAGE

L

NO C

BOARD

N

120

ORDERING INFO FEATURES SCHEDULING: 99 ON/OFF set points allow individual programs for each day of the week at a minimum 1 minute apart. SEASONS: 1 to 4 with different daily schedules which can wrap around into the new year.

CATALOG NO.

UPC CODE

TIMER SUPPLY (VAC) 50/60Hz

DTS100B NO. OF CHANNELS

DRY CONTACTS (UNPOWERED)

DTS100B

82185

120/208-240/277

1

DPDT

DTS200B

82186

120/208-240/277

2

SPDT

DTS400B

82187

120/208-240/277

4

SPDT

LOAD

DPDT L LOAD

C

NC

L LOAD

N

277V TIMER SUPPLY

120

NO C N

208-240 277

208-240V

N

NC

N

120V

AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE

L

LOAD

277V

CH 3 SPDT

N

NO NC

C

NO NC

UPPER BOARD

208-240 277

120V

C

TIMER SUPPLY

N

CH 1 SPDT

CH 2 SPDT

NO NC

C

120

NO

C

DTS400B

LOAD

N

N CH 1 SPDT

NO NC

CH 2 SPDT

NO C

TIMER SUPPLY

NC

L

LOAD

N

208-240 277

120

NC

NO C

NC

208-240 277

L

120V

208-240V

AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE

L

L LOAD

277V

LOAD

N

N

AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE

L

LOAD

208-240V

LOAD

N

277V

N

DPDT

N

MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. In signal mode, activates pulse.

C

TIMER SUPPLY

DTS100B

LEAP YEAR: Automatic Compensation.

120

NO NC

C

NO NC

208-240 277

CH 1 SPDT

120V

AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE

208-240V

L

L LOAD

CH 2 SPDT

LOAD

N N SPECIFICATION WRITER’S GUIDE C NO NC C NO NC DTS SERIES – 1. Furnish and install, where noted, a 4 (2) (1) channel digital time switch.DTS200B 2. Controller shall program in AM/PM (12 hour) or Military (24 hour) formats. 3. Controller shall program in one minute resolution. 4. Display shall be of LCD type. 5. Controller shall be capable of 99 set points; separate scheduling for each L day of the week. 6. Controller shall have 365 day holiday capabilities with 24 single dates and 4 seasonsACofLINEunlimited duration. 7. Different dailyL schedules shall be INPUT LOAD LOAD SELECT PROPER TERMINALS programmable within each season. 8. Controller shall have Daylight Saving or Standard time. 9.APPLY Controller have automatic Leap Year Ncorrection. 10. Controller shall AND ONLY ONEshall VOLTAGE N have Permanent Schedule Retention. 11. Controller shall have 7 day backup for real time with built in super capacitor. 12. Controller shall be capable of manual override DPDT ON to activate pulse #1 duration. 13. Unit shall have NEMA Type 3 Indoor/Outdoor enclosure as standard. 14. Controller shall be capable of having two different pulse durations 1-99 seconds, user settable and assignable to each channel. 15. To order specify TORK Model DTS100B (200B) (400B). 277V

TIMER SUPPLY

N

CLOCK FORMAT: AM/PM or Military time.

120

208-240 277

120V

208-240V

POWER OUTAGE BACKUP: Permanent schedule retention. Supercapacitor provides 7 days of real time back up.

277V

C

TIMER SUPPLY

DTS100B N

TORK 67

NC

L

LOAD

N

120V

DAYLIGHT SAVING: Automatic adjustment (can be omitted).

DIGITAL CONTROLS

C

LOWER BOARD N

SIGNAL/PULSE DURATION: 2 different settings per channel: each 1-99 seconds.

GND NO

L LOAD

277V

DTS200B

HOLIDAYS: 1 to 24 individual dates.

L

208-240V

AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE

CH 4 SPDT

120

NO NC

C

NO NC

208-240 277

120V

AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

208-240V 277V

L

L LOAD N

LOAD N

TORK 68

DW SERIES

SPECIFICATION FAVORITE!

MULTIPURPOSE CONTROLS 365 / 7 DAY ADVANCED 1 OR 2 CHANNEL TIME SWITCHES

CONTACT RATINGS

SPECIFICATIONS

VOLTAGE

General Purpose

NC

24-277VAC

30A

30A

Ballast

120VAC 277VAC

30A 20A

10A 10A

Tungsten

120-277VAC

15A

2A

Pilot Duty

120-277VAC

720VA

720VA

Motor Load

120VAC 208-277VAC

1HP 2HP

1HP 2HP

Resistive

28VDC

30A

30A

TERMINAL RANGE: #14 - #16AWG for line input. #12 - #16AWG load outputs. OPERATING TEMPERATURE: -40° to +158°(-40° to 70°C).

1 CHANNEL Outdoor lighting Security lighting Parking lot lighting Canopy lighting

RATING NO

TIMING ACCURACY: Line Frequency. INPUT VOLTAGE: 120/208-240-277VAC, 50/60Hz.

APPLICATIONS

POWER CONSUMPTION: 5VA Max. ENCLOSURE: Noryl Indoor/Outdoor NEMA 3R. Suffix -0 metal Indoor/Outdoor NEMA 3. All with lockable hasp (see page 153 for enclosure dimensions). ®

2 CHANNEL HVAC equipment Interior lighting Electric motors Refrigerator defrost control: condensers, heaters.

WIRING DIAGRAMS

DWZ100B DWZ100B SERIES SERIES

ORDERING INFO CATALOG NO.

UPC CODE

TIMER SUPPLY (VAC) 50/60Hz

NO. OF CHANNELS

DRY CONTACTS (UNPOWERED)

SCHEDULING: 99 ON & OFF set points allow individual programs for each day of the week at a minimum 1 minute apart.

DWZ100B

82189

120/208-240/277VAC

1

SPDT

DW200B

82190

120/208-240/277VAC

2

SPDT

ASTRONOMIC (DWZ100B only): Adjustable 10°- 60° Northern or Southern latitudes. Can be individually offset +/- 1 to 240 minutes from both sunset and sunrise times.

DW200B-0

FEATURES

TYPE

82231

120/208-240/277VAC

2

SPDT

TIMER SUPPLY TIMER SUPPLY

N

120

120V

N 208-240 120277 208-240

L

120V

277

SPDT

TIMER SUPPLY TIMER SUPPLYC

N

L N

277V

AC LINE INPUT AC LINE INPUT SELECT PROPER SELECTTERMINALS PROPER TERMINALS AND APPLY ONE VOLTAGE AND APPLY ONLY ONEONLY VOLTAGE

LOAD N

CH 1 CH 2 SPDT SPDT

CH 2 SPDT

DW200B DW200B SERIES SERIES

NO CNC NO NC

LOAD

208-240V208-240V 277V

C

SPDT

CH 1 SPDT

120

120V

N 208-240 120277 208-240 120V

L

208-240V208-240V 277V

277V

NO CNC NO C NC NO CNC NO NC

277

L LOAD N

L

L LOAD LOAD N

N

LOAD N

AC LINE INPUT AC LINE INPUT SELECT PROPER SELECTTERMINALS PROPER TERMINALS AND APPLY AND ONLY APPLY ONEONLY VOLTAGE ONE VOLTAGE

HOLIDAYS: 1 to 24 individual dates. DAYLIGHT SAVING: Automatic adjustment (can be omitted).

TWO SPEED TWOPUMP SPEEDWIRING PUMP WIRING

LEAP YEAR: Automatic Compensation scheduled ON or OFF, automatic operation then resumes.

SPECIFICATION WRITER’S GUIDE DWZ100B – 1. Furnish and install, where noted, a 1 channel digital time switch. 2. Controller shall program in AM/PM (12 hour) or Military (24 hour) formats. 3. Controller shall program in one minute resolution. 4. Display shall be of LCD type. 5. Controller shall be capable of 99 set points; separate scheduling for each day of the week. 6. Controller shall have 365 day holiday capabilities with 24 single dates. 7. Controller shall have Daylight Saving or Standard time. 8. Controller shall have automatic Leap Year correction. 9. Controller shall have Permanent Schedule Retention. 10. Controller shall have 7 day backup for real time with built in supercapacitor. 11. Controller shall be capable of manual override ON or OFF to the next scheduled event using 1 button. 12. Unit shall have NEMA Type 3 Indoor/Outdoor enclosure as standard. 13. Controller shall be capable of having astronomic with 1-240 minutes, plus or minus offset from sunrise or sunset. 14. To order specify TORK Model DWZ100B. DW200B – 1. Furnish and install, where noted, a 2 channel digital time switch. 2. Controller shall program in AM/PM (12 hour) or Military (24 hour) formats. 3. Controller shall program in one minute resolution. 4. Display shall be of LCD type. 5. Controller shall be capable of 99 set points; separate scheduling for each day of the week. 6. Controller shall have 365 day holiday capabilities with 24 single dates. 7. Controller shall have Daylight Saving or Standard time. 8. Controller shall have automatic Leap Year correction. 9. Controller shall have Permanent Schedule Retention. 10. Controller shall have 7 day backup for real time with built in supercapacitor. 11. Controller shall be capable of manual override ON or OFF to the next scheduled event using 1 button. 12. Unit shall have NEMA Type 3 Indoor/Outdoor enclosure.

MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. CLOCK FORMAT: AM/PM or Military time. POWER OUTAGE BACKUP: Permanent schedule retention. Supercapacitor provides 7 days of real time backup.

DIGITAL CONTROLS TORK 69

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

TORK 70

DZM SERIES

GREAT FOR LATCHING CONTACTORS

MOMENTARY OUTPUT 365 / 7 DAY ADVANCED LIGHTING CONTROL TIME SWITCH

APPLICATIONS

CALIFORNIA Title 24

Low voltage latching relays Direct wire to mechanically held contactors

General Purpose

120-277VAC

20A

Pilot Duty

120-277VAC

720VA

POWER CONSUMPTION: 4VA Max. ENCLOSURE: Noryl® Indoor/Outdoor NEMA 3R. Suffix -0 metal Indoor/Outdoor NEMA 3. All with lockable hasp (see page 153 for dimensions).

FEATURES

SEASONS: 1 to 4 with different daily schedules which can wrap around into the new year.

RATING

OPERATING TEMPERATURE: -40˚ to 158˚F (-40˚ to +70˚C).

ASHRAE 90.1

ASTRONOMIC: Adjustable 10° - 60° Northern or Southern latitudes can be individually offset +/- 1 to 240 minutes from both sunset and sunrise times.

VOLTAGE

TERMINAL RANGE: #14 - #16AWG for line input. #12 - #16AWG load outputs.

energy

WIRING DIAGRAMS

ORDERING INFO CATALOG NO.

UPC CODE

TIMER SUPPLY (VAC) 50/60Hz

NO. OF CHANNELS

DZM200BP

82188

120/208-240/277

2

DZM200BP-0

82232

120/208-240/277

2

USB-MMP

82196

Memory Module Programmer

DRY CONTACTS (UNPOWERED)

SPDT Momentary SPDT Momentary

TIMER SUPPLY AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE

N

120

208-240V

Includes software

277V

CH 1

DAYLIGHT SAVING: Automatic adjustment (can be omitted).

C

ON

CH 2

OFF

C

ON

OFF

MECHANICALLY HELD CONTACTORS OR LATCHING RELAYS

LEAP YEAR: Automatic Compensation. MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes.

L

L PULSE ON

PULSE OFF

N

CLOCK FORMAT: AM/PM or Military time. POWER OUTAGE BACKUP: Permanent scheduled retention with memory module. Supercapacitor provides 7 days of real time backup.

PULSE ON

PULSE OFF

N

SPECIFICATION WRITER’S GUIDE DZM 200BP only – 1. Furnish and install, where noted, a 2 channel digital time switch with portable Memory Module on front panel. 2. Memory Module shall be capable of being programmed at any one location and inserted into DZM200BP (with memory module socket) in any other remote location. 3. Optional programmer shall be available (Model MMP), capable of accomplishing Windows based settings on a PC for easy duplication of Memory Modules or individualized programs for multiple locations 4. Unit shall have copy feature: Can be configured to copy program schedules from one memory module to another without use of the optional memory module programmer. 5. Controller shall program in AM/PM (12 hour) or Military (24 hour) formats. 6. Controller shall program in one minute resolution. 7. Display shall be of LCD type. 8. Controller shall be capable of 99 set points; separate scheduling for each day of the week. 9. Controller shall have 365 day holiday capabilities with 24 single dates and 4 seasons of unlimited duration. 10. Different daily schedules shall be programmable within each season. 11. Controller shall have Daylight Saving or Standard time. 12. Controller shall have automatic Leap Year correction. 13. Controller shall have Permanent Schedule Retention. 14. Controller shall have 7 day backup for real time with built in super capacitor. 15. Controller shall be capable of astronomic function, adjustable from 10 – 60 degrees Northern or Southern latitude. Each zone can additionally be offset 1 - 240 minutes for both sunset and sunrise. 16. Controller shall be capable of manual override ON or OFF to the next scheduled event using 1 button for each channel. 17. Unit shall have NEMA Type 3 indoor/outdoor enclosure as standard. 18. Controller shall be capable of 2 independent momentary outputs ON and OFF for each channel. 19. To order specify TORK Model DZM200BP.

MEMORY MODULE: Removable MM can be programmed at any one location and inserted into another DZM series unit. COPY FEATURE: Unit can be configured to copy program schedule to multiple memory modules. OPTION: Memory Module Programmer with software for computer connection programming. Also allows stand alone battery operation for portable copy feature.

TORK 71

208-240 277

120V

HOLIDAYS: 1 to 24 individual dates.

DIGITAL CONTROLS

DZM200BP

TYPE

TIMING ACCURACY: Line frequency. INPUT VOLTAGE: 120/208-240/277VAC, 50/60Hz.

responsible

SCHEDULING: 99 ON & OFF set points allow individual programs for each day of the week at a minimum 1 minute apart.

CONTACT RATINGS

SPECIFICATIONS

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

TORK 72

ELC SERIES

ENERGY AND LIGHTING CONTROL 1 & 2 ZONE LIGHTING CONTROL TIME SWITCH

THE DO-IT-ALL ENERGY & LIGHTING CONTROLLER

NEW!

FEATURES

CALIFORNIA Title 24

CATALOG NO.

UPC CODE

TIMER SUPPLY (VAC) 50/60Hz

NO. OF CHANNELS

OUTPUT CONTACTS

ELC71PC/120

82517

120

1

DPDT

ELC71PC/208-240

82518

208-240

1

DPDT

ELC71PC/277

82519

277

1

DPDT

ELC72PC/120

82520

120

2

SPDT

ELC72PC/208-240

82521

208-240

2

SPDT

ELC72PC/277

82522

277

2

SPDT

EPC-LC

82233

LCS115M

82082

Accessory Photo Sensor Accessory Momentary Switch

SENSOR EVENT: 32 sensor driven events allow individual programs for each day of the week.

BLOCK HOLIDAY: 10 holiday blocks can be set for individual days or for duration of any number of days and may use one of 3 holiday schedules.

MOMENTARY CONTACT: May be configured for momentary ON/OFF operation to control latching contactors. The ELC71/72 operates as a single-channel unit.

DIGITAL CONTROLS TORK 73

VOLTAGE

General Purpose

POWER CONSUMPTION: 6VA Maximum.

ORDERING INFO

HOLIDAYS: 26 holidays may be set using 10 individual dates, 10 month type (last Monday in May), or 6 specific holidays with one of 3 independent holiday schedules.

UNIVERSAL INPUT: 2 inputs may be assigned to any channel. SWITCHED INPUT: Accepts input from optional momentary or maintained switch. PHOTOSENSOR INPUT: Accepts input from optional sensor. EPC-LC (indoor/outdoor) has a range from 0 to 200 foot-candles. USER DEFINED INPUT: Accepts user supplied 4 – 20 milliamp sensor.

TYPE

OPERATING TEMPERATURE: -20°F to +140°F (-29°C to + 60°C).

ASHRAE 90.1

SCHEDULING: 128 time based events allow individual programs for each day of the week at a minimum 1 minute apart. Event types include ON, OFF, Duration, or Duty Cycle.

ASTRONOMIC: Adjustable 10° - 70° Northern or Southern latitudes. Settings can be offset from both sunset and sunrise times.

TIMING ACCURACY: Line frequency.

TERMINAL RANGE: #10 - #16AWG for line/load. #14 - #22AWG universal input.

energy

HVAC equipment Indoor/Outdoor lighting Meets indoor/outdoor lighting energy code requirements

CONTACT RATINGS

INPUT VOLTAGE: 120, 208-240, 277 50/60Hz (model specific). responsible

APPLICATIONS

SPECIFICATIONS

PULSE/TIME DURATION: 4 different ON settings from 1 second to 23 hours, 59 minutes, 59 seconds. DUTY CYCLE: 4 different ON and OFF patterns from 1 second to 23 hours, 59 minutes, 59 seconds. DAYLIGHT SAVING: Automatic adjustment (can be omitted). LEAP YEAR: Automatic Compensation. REMOTE OVERRIDE: Universal input may be programmed for timed override from a momentary or maintained dry contact switch.

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

RATING NO

NC

120/277VAC

20 A

10 A

Ballast

120VAC 208-277VAC

20A 10A

10A

Tungsten

120-277VAC

5A

Pilot Duty

120-240VAC

470VA

275VA

Motor

120VAC 208-277VAC

1HP 2HP

1⁄4HP 1⁄2HP

ENCLOSURE: Noryl® clear cover Indoor/ Outdoor NEMA 3R with lockable hasp (see page 153 for enclosure dimensions).

WIRING DIAGRAMS

ELC72

ELC71

SPST

MANUAL OVERRIDE: Keyboard button control until the next regularly scheduled ON or OFF, automatic operation then resumes. STAGGERED START: Optional stagger up time between channels, after a power outage; selectable from 5 seconds, 15 seconds, 30 seconds, 1 minute, 5 minutes, 10 minutes, and 15 minutes. CLOCK FORMAT: AM/PM or 24 hour format POWER OUTAGE BACKUP: Capacitor provides minimum of 1 week of real time backup for program and time of day. SPECIFICATION WRITER’S GUIDE Installer shall furnish and install Tork ELC71 single-channel (or ELC72, two-channel) electronic time control. The control shall have 24 hour, 7 day, 365 day, or astronomic capability with 128 events available. It shall also have 4 user-definable durations and duty cycle lengths plus automatic daylight savings time and leap year adjustments. Control shall have remote override capabilities (timed, toggle or enable type.) Control shall have keyboard override until overridden again or until next event is reached. It shall be capable of switching loads based on user-definable temperature and light levels with 32 events available. Control shall have momentary (latching relay) capability and shall have astronomic features plus 30 definable holidays and 6 pre-programmed holidays. Controller shall have 7 day backup for real time with built in supercapacitor. The digital time display shall be 3⁄4” in height. Clock format shall be selectable, allowing a choice of 12 hour (AM/PM) or 24 hour format. Wiring terminals shall have the capability to accommodate #16 to #10 AWG wire. Control shall be housed in NEMA 3R enclosure with clear-view cover and shall be lockable to guard against vandalism or tampering.

TORK 74

ELC SERIES

ENERGY AND LIGHTING CONTROL 4, 8 & 12 ZONE LIGHTING CONTROL TIME SWITCH

THE DO-IT-ALL ENERGY & LIGHTING CONTROLLER

NEW!

energy

CALIFORNIA Title 24 ASHRAE 90.1

HVAC equipment Indoor/Outdoor lighting Meets indoor/outdoor lighting energy code requirements

FEATURES

UPC CODE

TIMER SUPPLY (VAC) 50/60Hz

NO. OF CHANNELS

OUTPUT CONTACTS

ELC74*

82523

24/120/208-240/277

4

SPDT

ELC78

82524

24/120/208-240/277

8

SPDT

ELC712

82525

24/120/208-240/277

12

SPDT

EPC-LC

82233

Accessory Photo Sensor

LCS115M

82082

Accessory Momentary Switch

TORK 75

INPUT VOLTAGE: 24/120/208-240/277VAC, 50/60Hz.

General Purpose

RATING NO

NC

120 - 277VAC

20A

10A

Ballast

120 VAC 208-277 VAC

20A 10A

10A 3A

Tungsten

120-277VAC

5A

Pilot Duty

120-240VAC

470VA

275VA

Motor

120VAC 208-277VAC

1HP 2HP

1⁄4HP 1⁄2HP

WIRING DIAGRAMS

SPST

*Also CSA certified.

BLOCK HOLIDAY: 10 holiday blocks can be set for individual days or for duration of any number of days and may use one of 3 holiday schedules.

DIGITAL CONTROLS

VOLTAGE

ENCLOSURE: Metal Indoor NEMA 1 with lockable hasp (see page 153 for dimensions).

CATALOG NO.

SENSOR EVENT: 32 sensor driven events allow individual programs for each day of the week.

MOMENTARY CONTACT: May be configured for momentary ON/OFF operation to control latching contactors. The ELC74 operates as a two channel unit. The ELC78 operates as a four channel unit. The ELC712 operates as a six channel unit.

TYPE

OPERATING TEMPERATURE: -20°F to +140°F (-29°C to + 60°C).

ORDERING INFO

HOLIDAYS: 26 holidays may be set using 10 individual dates, 10 month type (last Monday in May), or 6 specific holidays with one of 3 independent holiday schedules.

UNIVERSAL INPUT: 8 inputs may be assigned to any channel. ELC74 includes 4. SWITCHED INPUT: Accepts input from optional momentary or maintained switch. PHOTOSENSOR INPUT: Accepts input from optional sensor. EPC-LC (indoor/outdoor) has a range from 0 - 200 foot-candels. USER DEFINED INPUT: Accepts user supplied 4 – 20 milliamp sensor.

TIMING ACCURACY: Line frequency.

POWER CONSUMPTION: 10VA Maximum.

SCHEDULING: 128 time based events allow individual programs for each day of the week at a minimum 1 minute apart. Event types include ON, OFF, Duration, or Duty Cycle.

ASTRONOMIC: Adjustable 10° - 70° Northern or Southern latitudes. Settings can be offset from both sunset and sunrise times.

CONTACT RATINGS

TERMINAL RANGE: #10 - #16AWG for line input. #10 - #16AWG for load output. #14 - #22AWG universal input.

responsible

APPLICATIONS

SPECIFICATIONS

PULSE/TIME DURATION: 4 different ON settings from 1 second to 23 hours, 59 minutes, 59 seconds. DUTY CYCLE: 4 different ON and OFF patterns from 1 second to 23 hours, 59 minutes, 59 seconds. DAYLIGHT SAVING: Automatic adjustment (can be omitted). LEAP YEAR: Automatic Compensation. REMOTE OVERRIDE: Universal input may be programmed for timed override from a momentary or maintained dry contact switch. MANUAL OVERRIDE: Keyboard button control until the next regularly scheduled ON or OFF, automatic operation then resumes.

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

STAGGERED START: Optional stagger up time between channels, after a power outage; selectable from 5 seconds, 15 seconds, 30 seconds, 1 minute, 5 minutes, 10 minutes, and 15 minutes. CLOCK FORMAT: AM/PM or 24 hour format. POWER OUTAGE BACKUP: The program and time of day are maintained for a minimum of 2 days by means of a capacitor. After two days, a lithium battery takes over and provides a minimum accumulated time of 1 year. The lithium battery should provide over 10 years of protection. COMPUTER INTERFACE: Unit may be programmed with a PC. SPECIFICATION WRITER’S GUIDE Installer shall furnish and install Tork ELC74 four channel (ELC78 eight channel or ELC712 twelve channel) electronic time control. The control shall have 24 hour, 7 day, 365 day or astronomic capability with 128 events available. It shall also have 4 (8) user-definable durations and duty cycle lengths plus automatic daylight saving time and leap year adjustments. Control shall have remote override capabilities (timed, toggle or enable type). Control shall have keyboard override until overridden again or until next event is reached. It shall be capable of switching loads based on user-definable temperature and light levels with 32 events available. Control shall have momentary (latching relay) capability and shall have astronomic features plus 30 definable holidays and 6 pre-programmed holidays. Control shall provide 2 days of power outage carry-over without a battery. Control shall provide 10 years of power outage protection with a battery. The digital time display shall be 3⁄4” in height. Clock format shall be selectable, allowing a choice of 12 hour (AM/PM) or 24 hour format. Control shall be capable of interfacing (sending and receiving data) with a personal computer. Control shall be housed in a NEMA 1, lockable steel enclosure, to guard against vandalism or tampering.

TORK 76

CONTACT RATINGS

Resistive

TERMINAL RANGE: Relay #12AWG; input power terminals #14 - #22AWG; TOD/sensor terminals accept #18 - #22AWG. responsible

energy

APPLICATIONS

ASHRAE 90.1

Pilot Duty

POWER CONSUMPTION: 5VA Maximum.

NO

NC

120/240VAC 277VAC 120VAC 240/277VAC

20A 12A 20A 6A

10A

120/240/277VAC

5A

120/240VAC 277VAC

10A 3A 3A

LIGHT LEVEL

STAGE 1

470VA 690VA

4

5

6

STAGE 2

3

8

2

9 1

275VA 4

7

POWER

1

10

OTHER MOUNTINGS: LC200M mechanism only.

For 120 VAC Operation

NEUT 120V240V 277V

LINE INPUT

N H

WIRING DIAGRAMS

STAGE 1

C

NO NC

5

6

7

3

8

2

SET

ENCLOSURE: LC200 includes metal Indoor NEMA 1 with lockable hasp (see page 153 for dimensions).

EPC1 sensor supplied with unit.

Use to control two different outdoor lighting circuits utilizing one photocell. Sign lighting can turn ON at one ambient light level while parking lot lighting turns ON at a different light level.

9 10

RUN

STAGE 2

C

NO NC

OUTPUT 1 OUTPUT 2

WHITE BLACK

LOAD 1 TOD1 C TOD2

LOAD 2

CATALOG NO.

UPC CODE

INPUT SUPPLY (VAC) 50/60Hz

NO. OF ZONES

OUTPUT CONTACTS

PHOTOSENSOR INPUT: EPC1 included.

LC200

82111

120/240/277VAC

2

SPDT

DUAL OUTPUTS: with independent turn-ON adjustment for Stage1 and Stage 2.

LC200M

120/240/277VAC

2

5

6

STAGE 2

4

7

5

6

8

3

8

9

2

9 1

10

SET

LINE INPUT

10

RUN

H H

C

NO NC

C

NO NC

OUTPUT 1 OUTPUT 2

RED BLACK

LOAD 1 STAGE 1

STAGE 2

LOAD 2

SPDT For 277 VAC Operation NEUT 120V240V 277V

LINE INPUT

N H

C

NO NC

C

OUTPUT 1 OUTPUT 2

WHITE BLACK

NEUT 120V240V 277V

LINE INPUT

H H

LINE INPUT

N H

C

NO NC

C

NO NC

OUTPUT 1 OUTPUT 2

WHITE ORANGE

LOAD 1 LOAD 2

LOAD 2

For 240 VAC Operation

NEUT 120V240V 277V

NO NC

LOAD 1

SWITCHED INPUT: Can be used with a time switch for photocell ON of two different lighting circuits at different ambient light levels, then time-of-day OFF.

NEUT 120V240V 277V

7

3 2 1

For 120 VAC Operation

LIGHT LEVEL ACTIVATION: Turn ON is user settable from 2 to 100 footcandle; Independent light level adjustment for each zone. Turn OFF is a maximum of 2 times turn ON level. Built-in delay ON of 30 seconds to avoid reaction to lightning or headlights.

STAGE 1 4

POWER

82113

For 240 VAC Operation

LIGHT LEVEL

EPC

EPC1

ORDERING INFO FEATURES

Tungsten

OPERATING TEMPERATURE: -40°F to +140°F (-40°C to + 60°C).

TOD1 C TOD2

24 hour convenience stores Open wall parking structures Large canopies Building perimeters Atriums

Ballast

RATING

VOLTAGE

EPC

TYPE

INPUT VOLTAGE: 120/240/277VAC, 50/60Hz.

TOD1 C TOD2

SPECIFICATIONS

TOD1 C TOD2

STAGE LIGHTING TURN ON LEVEL

LIGHT LEVEL / TIME OF DAY OPTION 2 ZONES LIGHTING CONTROL TIME SWITCH

EPC1

LC200 SERIES

C

NO NC

C

NO NC

OUTPUT 1 OUTPUT 2

RED BLACK

LOAD 1

SPECIFICATION WRITER’S GUIDE LOAD 2 Furnish and install an electronic light sensor and control with dual outputs for two lighting zones. Each output shall be capable of a different user settable turn ON light level set For points277 fromVAC 2 to 100 footcandles. Turn ON to turn OFF ratio shall be 1:2. Controller shall also offer two digital inputs, which can accept a contact Operation closure from an independent time switch or EMS system, thereby allowing for independent time of day control. LINE INPUT OUTPUT 1 OUTPUT 2 NEUT 120V240V 277V

N H

C

NO NC

C

NO NC

WHITE ORANGE

LOAD 1 LOAD 2

DIGITAL CONTROLS TORK 77

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

TORK 78

DGU & DGLC SERIES

CODE SOLUTION FOR SMALL PROJECTS

NEW!

LIGHTING CONTROL WITH PHOTO OR OVERRIDE INPUT, 7 DAY 7 DAY LIGHTING CONTROL TIME SWITCH

TERMINAL RANGE: #12 - #18AWG for line/load. #18 - #26AWG sensor/switch input.

responsible

energy

APPLICATIONS

EXTERIOR LIGHTING Signage and store windows Security Parking lots

FEATURES

ASHRAE 90.1

Model EPC-A supplied with DGLC-A unit.

CATALOG NO. With optional Timed Override

82211

120-277VAC

1

DPDT

DGUM100A

82212

120-277VAC

1

DGUM100A-Y

82224

120-277VAC

1

SPDT Momentary SPDT Momentary

DGLC100A-NC

82223

120-277VAC

1

DPDT

DGLC200A-NC

82213

120-277VAC

2

SPDT

EPC-A

82112

Accessory Photo Sensor

SSA200R-24

14015

24VAC/24VDC

TRP-U

82030

120/277VAC

PHOTOSENSOR INPUT: Unique push button set-up assures accurate operation with automatic calibration that adjusts for wire size and distance. EPC-A photo sensor is included with the DGLC-A and may be ordered as an option for use with model DGU100A & DGUM100A.

MOMENTARY CONTACT - DGUM100A: 2 second contact closure ON & OFF to control mechanically held contactors or latching relays.

DIGITAL CONTROLS TORK 79

OUTPUT CONTACTS

VOLTAGE

Resistive

ENCLOSURE: Noryl® Indoor/Outdoor NEMA 3R . Suffix -NC Noryl® Indoor/Outdoor NEMA 3R with clear Lexan® cover. Suffix -Y metal Indoor enclosure NEMA 1. All with lockable hasp (see page 153 for dimensions).

RATING NO

NC

24-277VAC

20A

10A

Ballast

120VAC 277VAC

20A

10A

Tungsten

120VAC

15A

Motor

POWER CONSUMPTION: 6VA Maximum.

INPUT SUPPLY NO. OF (VAC) 50/60 Hz CHANNELS

DGU100A-Y

MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes.

REMOTE OVERRIDE ON: Each channel has independent input for a maintained dry-contact closure. May use TORK model SSA200R-24 and TRP-U for timed override. May use with occupancy sensor as override.

UPC CODE

TYPE

Pilot Duty

OPERATING TEMPERATURE: -31°F to +131°F (-35°C to + 55°C).

ORDERING INFO

SCHEDULING: 56 ON & OFF set points provide individual programs for each day of the week. Minimum setting is 1 minute.

LIGHT LEVEL ACTIVATION: Turn ON is user settable from 1 to 100 footcandle; Turn OFF is a maximum of 2 times turn ON level. Each channel has an independent setting. Includes a user settable delay before ON or OFF between 1 – 90 seconds.

TIMING ACCURACY: Line frequency. INPUT VOLTAGE: 120-277VAC, 50/60Hz (auto detection).

CALIFORNIA Title 24

INTERIOR LIGHTING Open office zoning Hallways Meeting and sales areas Stock rooms and warehouses

CONTACT RATINGS

SPECIFICATIONS

Resistive

120VAC 240VAC 120VAC 240VAC 28VDC

DGU100A

1HP 2HP

290VA 360VA 1⁄4HP 1⁄2HP

20A

10A

720VA

DGUM100A

DGU100A

WIRING DIAGRAMS DGU100A

DGLC100A

DGUM100A

SPDT Transformer Power Pack

SPST

DGUM100A

DGLC100A

DGLC200A

BLOCK HOLIDAY: 9 holiday blocks can be set for individual days or for duration of any number of days. DAYLIGHT SAVING: Automatic adjustment (can be omitted). LEAP YEAR: Automatic Compensation. CLOCK FORMAT: AM/PM or 24 Hour format. POWER OUTAGE BACKUP: Permanent schedule retention. Supercapacitor provides 7 days of real time backup.

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

DGLC100A

DGLC200A

SPECIFICATION WRITER’S GUIDE DGU and DGLC SERIES - 1. Furnish and install, where noted, a 1 (2) channel 7 day programmable digital time switch. 2. Controller shall program in AM/PM (12 hour) or Military (24 hour) formats. 3. Unit shall be capable of switching 20 amps ballast load at 277VAC. 4. Controller shall be capable of 56 set points; separate scheduling for each day of the week with one minute resolution. 5. Controller shall have photo sensor input user adjustable per circuit between 1 and 100 footcandle turn ON level. 6. Each channel shall have and switched input to override circuit ON. 7. Controller shall have 365 day holiday capabilities with 9 block holidays for individual or duration of any number of days. 8. Controller shall be able to select USA Standard Daylight Saving, Standard time, or programmable dates. 9. Controller shall have automatic Leap Year correction. 10. Controller shall have Permanent Schedule Retention. 11. Controller shall have 7 days backup for real time with built in super capacitor; no batteries to maintain. 12. Controller shall be capable of Manual Override ON and OFF to the next scheduled event using 1 button for each channel. 13. Unit shall have NEMA type 3R indoor/outdoor enclosure standard. 14. To order specify TORK Model DGU100A. (Alt 14. To order 1 channel momentary contact closure for latching contactor control specify DGUM100A). (Alt 14. To order controller with EPC-A photo sensor included in package specify TORK Model DGLC100A-NC (DGLC200A) with clear cover.

TORK 80

DLC400BP

FLEXIBLE INDOOR/ OUTDOOR LIGHTING CONTROLLER

4 ZONE LIGHTING CONTROL TIME SWITCH

responsible

energy

APPLICATIONS INTERIOR LIGHTING Open office zoning Hallways Meeting and sales areas Stock rooms and warehouses EXTERIOR LIGHTING Signage and store windows Security Parking lots

FEATURES CONFIGURABLE ZONES: Simple three position slide switch sets logic for each zone: Time ON/Time OFF, Photo ON/Photo OFF, or Photo ON/ Time OFF. SCHEDULING: 99 ON & OFF set points allow individual programs for each day of the week. Minimum 1 minute apart. ASTRONOMIC: 1. Adjustable 10° - 60° Northern or Southern latitudes. 2. Can be individually offset +/-1-240 minutes from both sunset and sunrise times. PHOTOSENSOR INPUT: EPC2 photo sensor included. LIGHT LEVEL ACTIVATION: Turn ON and OFF level is user settable from 1 to 100 footcandle. Each channel has an independent setting. REMOTE OVERRIDE: Maintained dry contact closure or use TORK Model SSA200R-24 for timed override with flash warning before OFF. May use with occupancy sensor as override.

DIGITAL CONTROLS TORK 81

CALIFORNIA Title 24

SPECIFICATIONS TIMING ACCURACY: Line frequency. INPUT VOLTAGE: 120/208 - 240/277VAC, 50/60Hz.

CONTACT RATINGS TYPE

VOLTAGE

General Purpose 24-277VAC, 30VDC

RATING NO

NC

30A

30A 10A

TERMINAL RANGE: #10 - #14AWG.

Ballast

120-277VAC

20A

OPERATING TEMPERATURE: -40°F to +158°F (-40°C to + 55°C).

Tungsten

120VAC

10A

Pilot Duty

120-277VAC

720VA

720VA

POWER CONSUMPTION: 30VA Maximum.

ASHRAE 90.1

ENCLOSURE: Metal Indoor/Outdoor NEMA 3 with lockable hasp (see page 153 for dimensions).

Model EPC2 supplied with unit. Memory Module Programmer optional

WIRING DIAGRAMS

With optional Timed Override

ORDERING INFO CATALOG NO.

UPC CODE

INPUT SUPPLY (VAC) 50/60 Hz

NO. OF CHANNELS

OUTPUT CONTACTS

DLC400BP

82191

120/208-240/277

4

SPDT

USB-MMP

82196

Memory Module Programmer

SSA200R-24

14015

24VAC/24VDC

Includes Software SPDT

MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. SEASONS: 1 to 4 with different daily schedules which can wrap around into the new year. HOLIDAYS: 1 to 24 individual dates. DAYLIGHT SAVING: Automatic adjustment (can be omitted). LEAP YEAR: Automatic Compensation. POWER OUTAGE BACKUP: Permanent schedule retention with memory module. Battery provides real time backup for 6 months cumulative. MEMORY MODULE: Removable MM can be programmed at any one location and inserted into another DZS series unit. OPTION: Memory Module Programmer with software for computer connection programming. Also allows stand alone battery operation for portable copy feature.

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

SPECIFICATION WRITER’S GUIDE

DLC400BP – 1. Furnish and install, where noted, a 4 zone lighting controller with photosensor input (TORK model EPC2 photosensor to be supplied with controller). 2. Memory Module shall be capable of being programmed at any one location and inserted into DLC400BP (with memory module socket) in any other remote location. 3. Optional programmer shall be available (Model MMP), capable of accomplishing Windows based settings on a PC for easy duplication of Memory Modules or individualized programs for multiple locations 4. Each zone shall be capable of independent, user settable turn ON and turn OFF light level set points ranging from 1 to 100 footcandles. 5. Three position slide switches shall be provided for each of the 4 zones allowing for user settings based on a) time of day or b) combination time of day and light level or c) light level. 6. Controller shall provide 30 Amp General Purpose isolated contacts (unpowered) for each zone as well as a 500 ma, 24VDC output. 7. Controller shall have 1 digital input per channel for: a) remote contact closure which can be used to turn corresponding outputs ON/OFF outside of the normal control time or b) remote timed override which can be accomplished for the corresponding outputs with the use of TORK model SSA200R-24. 8. Enclosure shall provide separate wiring compartments for power connections and auxiliary connections. 9. Controller shall be capable of local override ON or OFF to the next scheduled event using the keypad for each zone. 10. Each zone shall be capable of astronomic function, adjustable from 10 – 60 degrees Northern or Southern latitude. Each zone can additionally be offset +/- 1–299 minutes for both sunset and sunrise. 11. Controller shall provide automatic daylight saving time (which can be omitted). Leap year adjustment shall be compensated for automatically. 12. Controller shall have 365 day holiday capability with 24 single dates and 4 seasons of unlimited duration. 13. Controller shall be capable of 99 set points with separate scheduling for each day of the week. 14. Controller shall have back-up capability: a) Schedule shall be retained for 40 years without power, b) real time shall be retained for 6 months using a field replaceable 9V lithium battery. 15. Unit shall have a NEMA type 3, metal indoor/outdoor enclosure.

TORK 82

LD SERIES

ADD A WARNING BLINK TO ANY CONTROL

EXTENDED LIGHTING CONTROL LIGHTING DELAY TIME SWITCH

INPUT VOLTAGE: 120/208/240/277VAC, 50/60Hz. TERMINAL RANGE: #10 - #16AWG. OPERATING TEMPERATURE: -22° to 150°F (-30° to +65°C).

ASHRAE 90.1

APPLICATIONS

CONTACT RATINGS

SPECIFICATIONS

POWER CONSUMPTION: 5VA Maximum.

®

®

ENCLOSURE: Metal Indoor NEMA 1 with lockable hasp (see page 153 for dimensions).

®

®

Open offices Gymnasiums Warehouses Outdoor recreation courts User-activated lights with time limits Match with photocontrol and timer to limit hours of use

RATING

TYPE

VOLTAGE

General Purpose Ballast

24/240VAC 277VAC 120VAC 208-277VAC

Tungsten

120-277VAC

5A

3A

Pilot Duty

120-240VAC 27VAC

470VA 690VA

275VA

Resistive

28VDC

20A

10A

NO

NC

20A 20A 20A 10A

10A 3A 10A 3A

WIRING DIAGRAMS LDSH WIRING

LDS WIRING

TORK TIME SWITCH

TORK TIME SWITCH

OUTPUT TERMINALS

OUTPUT TERMINALS OFF

NO

C

OFF

NC

MOMENTARY PUSH-BUTTON SWITCH

C ON OFF DO NOT APPLY VOLTAGE

N

TIME SWITCH INPUT

120

208 240

H

REMOTE INPUT

277 VAC

H C ON OFF DO NOT APPLY

INPUT POWER

VOLTAGE

NO

N

N

C

277 VAC

INPUT POWER

AUX. OUTPUT TERMINALS NC

208 240

120

TIME SWITCH INPUT

MAIN LOAD OUTPUT TERMINALS NC

120 VAC

ON

ON

N

NC

N

N

H

C

MOMENTARY PUSH-BUTTON SWITCH

H

REMOTE INPUT

NO

MAIN LOAD OUTPUT TERMINALS

NO

C

NC

NO

C

H

H

H

AUX LOAD

ORDERING INFO

FEATURES MAINTAINED INPUT WITH LOAD WARNING BLINK: LDS Series controls output load contacts based on power applied to the time switch input contact. At removal of power from the time switch input, LDS Series provides 1 second blink then keeps load contacts closed for an extra 1 or 5 minutes (user selectable) before turn off. MAINTAINED INPUT WITH AUXILARY WARNING: LDSH Series controls output load contacts based on power applied to the time switch input contact. At removal of power from the time switch input, LDSH Series closes a second set of contacts for a user supplied audible or visual warning device. The warning circuit closes for a selected time of 4 seconds (best for audible device or continuous, then keeps load contacts closed for an extra 1 or 5 minutes (user selectable) before turn OFF.

CATALOG NO.

LDS-A LDS LDSH-A LDSH

UPC CODE

81026 81025 81031 81028

INPUT SUPPLY (VAC) 50/60 Hz

120/208-240/277 120/208-240/277 120/208-240/277 120/208-240/277

MOMENTARY INPUT: Provides timed override when time switch input contact is unpowered (timer OFF). When activated during the warning period, load contacts are kept closed and timing starts. Both series can accept momentary input contact closure for ON to start the timing and OFF to end the timing. TIMED OVERRIDE SETTINGS: User may select override times of 1⁄2, 1, 11⁄2, 2, 6, 9, or 12 hours. Warning before OFF is always active after override time.

LOAD

OUTPUT CONTACTS

ENCLOSURE TYPE

SPDT

Metal Indoor NEMA 1

SPDT SPDT SPDT

Mechanism Metal Indoor NEMA 1 Mechanism

N

TORK TIME SWITCH

TORK TIME SWITCH

OUTPUT TERMINALS

OUTPUT TERMINALS OFF

NO

C

OFF

NC

MOMENTARY PUSH-BUTTON SWITCH

VOLTAGE

N

TIME SWITCH INPUT

N

120

208 240

H 120 VAC

REMOTE INPUT

277 VAC

H C ON OFF DO NOT APPLY

INPUT POWER

VOLTAGE

NO

N

N

C

NO

277 VAC

INPUT POWER

AUX. OUTPUT TERMINALS NC

208 240

120

TIME SWITCH INPUT

MAIN LOAD OUTPUT TERMINALS NC

NC

ON

ON

H

C

N

N

C ON OFF DO NOT APPLY

NO

MOMENTARY PUSH-BUTTON SWITCH

H

REMOTE INPUT

N

LOAD

N

MAIN LOAD OUTPUT TERMINALS C

NC

NO

C

H

H

H ON OFF COMMON

AUX LOAD MECHANICALLY HELD CONTACTOR WITH COIL CLEARING CONTACTS

ON

N

MECHANICALLY HELD CONTACTOR WITH COIL CLEARING CONTACTS

OFF COMMON

PHOTOCONTROL

N

N

TORK TIME SWITCH OUTPUT TERMINALS

APPLICATION EXAMPLE

Lighting for a high school’s tennis courts turns on during normal class hours when natural light diminishes using a 7 day time switch and photocell. After 3pm, staff members sometimes use the courts (the time switch is then off). A momentary pushbutton activates the LDSH for timed override of HID lighting. Five minutes before the lights go out, an auxiliary contact flashes an incandescent warning beacon (HID lighting can not be made to blink). Additional timed override can be arranged for via the momentary pushbutton.

APPLICATION WIRING

NO

C

NC

FLASHING LIGHT

H

120V

N

C

ON

H

OFF

N

N

120 208/240277

REMOTE INPUT TIME SWITCH INPUT

MOMENTARY PUSHBUTTON SWITCH

AUXILLARY OUTPUT NO C

LDSH

NC

INPUT POWER N

MAIN LOAD OUTPUT NO C

NC

120V

OFF N ON

H 120V N OFF

SWITCHED CIRCUIT TO TENNIS COURT LIGHTS

ON

N

MECHANICALLY-HELD 4 POLE LIGHTING CONTACTOR

SWITCHED CIRCUIT TO TENNIS COURT LIGHTS

480V CIRCUITS FROM PANEL

DIGITAL CONTROLS TORK 83

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

TORK 84

DGS SERIES

SIGNALING AND DUTY CYCLE 24 HOUR OR 7 DAY TIME SWITCH

31 DAY CYCLE TIME: AN INDUSTRY FIRST!

NEW!

SPECIFICATIONS TIMING ACCURACY: Line frequency. INPUT VOLTAGE: 120 - 277 VAC, 50/60 Hz (auto detection). TERMINAL RANGE: #12 - #18AWG. OPERATING TEMPERATURE: -31°F to +131°F (-35°C to + 55°C).

APPLICATIONS

POWER CONSUMPTION: 6VA Maximum.

Signaling Duty cycle

ENCLOSURE: Noryl Indoor/Outdoor NEMA 3R with lockable hasp (see page 153 for enclosure dimensions). ®

CONTACT RATINGS TYPE

VOLTAGE

Resistive

RATING NO

NC

24-277VAC

20A

10A

Ballast

120VAC 277VAC

20A

10A

Tungsten

120 VAC

15 A

Motor

120 VAC 240VAC 120VAC 240VAC

Resistive

28VDC

Pilot Duty

720VA 1HP 2HP 20A

290VA 360VA 1⁄4HP 1⁄2HP DGS100A

FOR 120V/277VAC 10A

WIRING DIAGRAMS DGS100A FOR 208-240VAC DGS100A FOR 120V/277VAC

DG180A FOR 120V/277VAC

ORDERING INFO

FEATURES DG180A & DG280A: 56 ON & OFF set points provide individual daily programs. Minimum setting is 1 minute. DGS100A: 56 ON & OFF set points provide individual programs for each day of the week. Minimum setting is 1 minute. DUTY CYCLE: Two different ON/OFF patterns or signal durations may be programmed. The durations can be up to 23 hours, 59 minutes and 59 seconds in length. SKIP FUNCTION (24 HOUR UNITS ONLY): Each channel can be set for ACTIVE/SKIP operations that alternate from 1 - 31 days. This becomes an effective way to cycle loads on varying days within the month. Using the two-circuit DG280A, two loads can be set to operate on alternate days in a simple manner.

CATALOG NO.

UPC CODE

INPUT SUPPLY (VAC) 50/60 Hz

NO. OF CHANNELS

OUTPUT CONTACTS

24 HOUR MODELS DG180A

82206

120-277VAC

1

DPDT

DG280A

82207

120-277VAC

2

SPDT

DG280A-24

82220

24VAC

2

SPDT

120-277VAC

1

DPDT

DGS100A-12 82218

12VDC

1

DPDT

DGS100A-24 82219

24VAC

1

DPDT

DGS100A FOR 208-240VAC

DG180A FOR 208-240VAC

DG280A

7 DAY MODELS DGS100A

82205

DAYLIGHT SAVING: Automatic adjustment (can be omitted).

DG280A

LEAP YEAR: Automatic Compensation. MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. CLOCK FORMAT: AM/PM or 24 hour. POWER OUTAGE BACKUP: Permanent schedule retention. Supercapacitor provides 7 days of real time backup.

DIGITAL CONTROLS TORK 85

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

SPECIFICATION WRITER’S GUIDE DGS100A SERIES –1. Furnish and install, where noted, a 1 channel 7 day programmable digital time switch. (Alt 1 DG180 Series 1. Furnish and install, where noted, a 1 (2) channel 24 hour programmable digital time switch. 2. Controller shall program in AM/PM (12 hour) or Military (24 hour) formats. 3. Unit shall be capable of switching 20 amps ballast load at 277VAC. 4. Controller shall be capable of 56 set points; separate scheduling for each day of the week with one minute resolution. 5. unit shall be capable of two duty cycle or signal durations from 1 second to 23 hours, 59 minutes and 59 seconds. 6. Controller shall be able to select USA Standard Daylight Saving, Standard time or programmable dates. 7. Controller shall have automatic Leap Year correction. 8. Controller shall have Permanent Schedule Retention. 9. Controller shall have 7 days backup for real time with built in super capacitor; no batteries to maintain. 10. Controller shall be capable of Manual Override ON and OFF to the next scheduled event using 1 button for each channel. 11. Unit shall have NEMA type 3R indoor/outdoor enclosure as standard. 12. To order specify TORK Model DGS100A (Alt 12. Controller shall have a 31 day cycle to alternate days that programs are active or to be omitted. 13. To order specify TORK Model DG180A [DG280A]).

TORK 86

EJWT & E500T SERIES

NEW!

PERFECT FOR PROCESS CONTROL

DELAY, INTERVAL & PERCENTAGE TIME CYCLE TIME SWITCHES

SPECIFICATIONS

CONTACT RATINGS

TIMING ACCURACY: 1% of timing range.

TYPE

VOLTAGE

General Purpose Resistive

INPUT VOLTAGE: 120/240VAC, 60Hz. TERMINAL RANGE: #12 - #18AWG. OPERATING TEMPERATURE: 32°F to +122°F (0°C to + 50°C).

APPLICATIONS

POWER CONSUMPTION: 16VA Maximum.

EJWT

RATING NO

NC

120-240VAC

20A

10A

120-240VAC

20A

10A

Motor

120VAC 208-240VAC

1HP 2HP

1⁄4HP

Pilot Duty

120/240VAC

470VA

275VA

1⁄2HP

ENCLOSURE: Indoor NEMA 4X is standard (see page 153 for enclosure dimensions).

Poultry and livestock Agriculture or greenhouse Oil well pumping Ventilation Process control

E502T

E501T

EJWT

ORDERING INFO FEATURES EJWT – PERCENTAGE TIMER • 960 time combinations with two dials. • Cycle Time Dial sets 32 repeating cycles from 15 seconds to 24 hours. • Percentage ON Dial has 32 steps from 0% to 100%. • Repeats cycle as long as power is applied.

CATALOG NO.

UPC CODE

INPUT SUPPLY (VAC) 60 Hz

OUTPUT CONTACT

EJWT

82513

120-240VAC

SPDT

E500T

82514

120-240VAC

SPDT

E501T

82515

120-240VAC

SPDT

E502T

82516

120-240VAC

SPDT

E500T – ON DELAY TIMER • Dial sets 32 time delay durations from 5 seconds to 3 hours. • External switch activated starts delay to ON. • Runs until external switch turns OFF.

WIRING DIAGRAMS

EJWT

E500T / E501T / E502T

E501T – AUTO OFF INTERVAL TIMER • Dial sets 32 time durations from 10 seconds to 12 hours. • Start/Stop button or External switch starts interval ON. • Automatically turns OFF at end of preset time. • START/STOP or External switch turns OFF. E502T – OFF DELAY TIME • Dial sets 32 time durations from 5 seconds to 3 hours. • External switch starts interval ON. • Automatically turns OFF at end of preset time. • External switch turns OFF.

DIGITAL CONTROLS TORK 87

E500T / E501T / E502T

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

TORK 88

DIN SERIES

1 OR 2 CHANNEL 7 DAY TIME SWITCH

ASHRAE 90.1

CONTACT RATINGS

SPECIFICATIONS

PANEL BUILDERS CHOICE

CALIFORNIA Title 24

NEW!

OPERATING TEMPERATURE: DIN100B: 14°- 131°F (-10°- +55°C). DIN200B: 14°- 113°F (-10°- +45°C).

Panel builders Indoor/Outdoor lighting Security systems HVAC equipment

CALIFORNIA Title 24

DIN100B

VOLTAGE

Resistive

POWER CONSUMPTION: 4VA Maximum.

ASHRAE 90.1

RATING NO

NC

120VAC

16A

16A

General Purpose

120VAC

8A

8A

Motor (DIN100 only)

120VAC

1⁄2HP

TERMINAL RANGE: #12 - #18AWG.

APPLICATIONS

TYPE

INPUT VOLTAGE: 120VAC, 50/60Hz.

MOUNTING: DIN rail #50022 (35mm) or flat surface using supplied adapter.

DIN200B

WIRING DIAGRAMS

DIN200B DIN200B

DIN100B

DIN100B

ORDERING INFO UPC CODE

DRY CONTACTS

CLOCK INPUT 50/60 Hz

NO. OF CHANNELS

NUMBER OF ON/OFF

DIN100B

82193

SPDT

120VAC

1

8

2

4 Channel A 3 Channel B

DIN200B

82192

SPDT

120VAC

35.80

Channel B (C2) Output

55.00

52.5

NC

14

8

7

6

1

2

3

DIN100B 35.80

46.00 60.00

5

6

1

2

NC

NO

2

3

4

5

Input

D

Channel B (C2)

NO

3

1

Channel A (C1)

14

8

7

6

1

2

3

85

85.00

45.00

7

6

60

Channel B (C2)

8

7

35.2

Channel A (C1) Output

52.5

NC

8

Channel A (C1)

Channel B (C2) Output

55.00

4

NC

NO DIN200B

CLOCK FORMAT: AM/PM.

Channel B (C2)

NO 85

MANUAL OVERRIDE: Until the next regular scheduled ON or OFF, automatic operation then resumes. POWER OUTAGE BACKUP: Battery retains time and schedule.

60

Channel B (C2) 85.00

SCHEDULING: 8 ON and OFF pairs of set points for DIN100B. 4 ON and OFF (CH A) and 3 ON and OFF (CH B) pairs of set points for DIN200B. Individual programs on each day of the week. Minimum setting is 1 minute.

CATALOG NO.

45.00

FEATURES

4

35.2

5

4

5

Channel A (C1)

Channel A (C1) 46.00 60.00

DIGITAL CONTROLS TORK 89

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

Channel A (C1) Output

Input

TORK 90

SMC SERIES

5401 SERIES

SPECIFICATIONS

MOMENTARY CONTACT ADAPTER

INCREASED AMPERAGE & VOLTAGE SWITCHING 40 AMP CONTACTORS

INPUT VOLTAGE: 120VAC, 50/60Hz. TERMINAL RANGE: #12 - #18AWG. OPERATING TEMPERATURE: -31°F to +131°F (-35°C to + 55°C). POWER CONSUMPTION: 6VA max.

APPLICATIONS

ENCLOSURE: Noryl® Indoor/Outdoor NEMA 3R with lockable hasp (see page 153 for dimensions).

Converts maintained contacts for pulse switching Timer to latching contactor control Photocell to latching contactor control Signaling

CONTACT RATINGS

5401

Lighting loads Exhaust fans Electric and hot water heaters Refrigeration and defrosting

5441

TYPE

VOLTAGE

RATING

Resistive

120-600VAC

50A

FLA

120-600VAC

40A

Motor

120VAC 240VAC 480VAC 600VAC

3HP 7.5HP 20HP 25HP

ORDERING INFO UPC CODE

INPUT SUPPLY (VAC) 50/60Hz

OUTPUT CONTACTS

SMC3D

52011

120

SPDT Momentary

CONTACT RATINGS NC

Resistive

120VAC

10A

10A

General Purpose

120VAC

10A

10A

Motor

120VAC

1⁄4HP

NC

SMC 3D ON RELAY NC NO C

5401

H 120VAC N

INPUT 120 VAC OFF RELAY

BLACK

NC NO C

WHITE

Control circuit from Time Switch

ON PULSE

120VAC

NEUTRAL

N

L

C

NO

AUX

LOAD

DIGITAL CONTROLS TORK 91

LOAD

N

LOAD

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

NC H

CONTACT

277VAC 480VAC

81021 81022

120VAC 208VAC 277VAC 480VAC

Wire B, C the sa

NO. AOF CONTACTORS

120

1

120

4

OUTPUT CONTACTS N

B

3PST

120VAC 208VAC 277VAC 480VAC

Control circuit from Time Switch

24VAC Wire other circuits B, C and D respectively

120 to 480VAC

{

A

N

C

D

C

D

A

Keep low voltage wires inside this compartment.

120VAC 208VAC 277VAC 480VAC

B

Wire contactors B, C and D the same as A.

D

B

120VAC 208VAC 277VAC 480VAC

Wire other c

3PST

C

A

24VAC

5441

120 to 480VAC

Control circu

B

Control circuit from Time Switch

120VAC

C

D

Keep low voltage wires inside this compartment.

Wire other circuits B, C and D respectively

120VAC

120 VAC

SMC 3D ON RELAY

OFF RELAY

NC NO C

NC NO C

PUSH ON

{

N

120VAC

COIL VOLTS

{

TORK DIGITAL CONTROL TERMINAL BLOCK

MAINTAINED CONTACT INPUT

L

5401

{

UPC 120VAC CODE 208VAC

120VAC 208VAC 277VAC 480VAC

Control circuit from Time Switch

Wire contactors B, C and D the same as A.

H

REALAY CONTACTOR

L

CATALOG NO.

5441

PUSH OFF

OFF PULSE

120VAC 208VAC 277VAC 480VAC

5

120VAC 208VAC 277VAC 480VAC

120VAC 208VAC 277VAC 480VAC

ORDERING 5440INFO

N

PUSH ON

LOW VOLTAGE LATCHING RELAY OR MECHANICALLY HELD CONTACTOR

WHITE

ENCLOSURE: 5401 - Metal NEMA 3 enclosure. 5441 - Metal NEMA 1 Indoor enclosure (see page 153 for enclosure dimensions).

TORK DIGITAL CONTROL TERMINAL BLOCK MAINTAINED CONTACT INPUT

NO

BLACK

EASY WIRING: Includes 120 volt control wiring compartment. 5441 has terminal strip pre-mounted for quick connection.

SMC 3D 120VAC, 240VAC Input – Sustained voltage 120VAC WIRING DIAGRAMS 277VAC, 30VDC Momentary Contacts (unpowered) 30 Amps inrush

C

5401

CONTACT RATINGS: Can switch up to 40 AMPS per pole from 120VAC to 600VAC, one to three circuits simultaneously.

{

NO

{

MOMENTARY OUTPUT: SMC3D provides two dry output contacts. The ON contact provides a 2 second contact closure (pulse) when power is applied to the input contacts. The OFF contact provides a 2 second pulse when power is removed from the input contacts.

RATING

VOLTAGE

WIRING DIAGRAMS

FEATURES

{

TYPE

MAINTAINED INPUT: SMC3D accepts maintained input power from any 120 volt control. When power is applied or removed a short contact closure (pulse) is created on the dry output contacts.

Coil Data: 120VAC @ 60Hz 6VA Holding/seal; 60VA inrush

{

FEATURES

CATALOG NO.

{

APPLICATIONS

TORK 92

HPS STARTER

SPECIFICATIONS

FOR HIGH PRESSURE SODIUM LAMPS STARTING AID

LINE VOLTAGE: 105 - 347VAC. LAMP VOLTAGE: 55 or 100VAC.

TRP SERIES

SPECIFICATIONS

LOW VOLTAGE SWITCHING TRANSFORMER RELAY POWER PACKS

CONTACTS: SPST contacts. CONTACT RATING: 20 Amps Ballast @ 120 or 277VAC. 15 Amps Tungsten @ 120VAC. 1.0 Horsepower @ 120VAC.

LAMP WATTAGE: 35 to 400 watts. OPERATING TEMPERATURE: -40°F to +221°F (-40°C to + 105°C).

APPLICATIONS

LEAD LENGTH: 9 inches. ENCLOSURE: Durable, high temperature

Designed to operate as a starting aid, for all H.P.S. ballasts from 35 to 400 watts, with lamp voltage of 55 or 100 volts.

Lexan® housing.

APPLICATIONS

TEMPERATURE RANGE: 0° to 150°F (–18° to 66°C). Pre-wired in metal enclosure.

Low voltage switching of line voltage lighting circuits up to 20 Amp ballasts or 15 amp tungsten loads. Also up to 1.0 HP motors for ventilating and exhaust fans. Low voltage switching by digital or mechanical controls for higher amperage loads including those of two different voltages.

ORDERING INFO FEATURES SMART VOLTAGE: Delivers appropriate trigger spikes for lamp ignition, then reduces voltage to good lamps. Continues to feed voltage spikes to old or poorly working lamps.

CATALOG NO.

UPC CODE

DESCRIPTION

HPS30

81030

High Pressure Sodium Starter

BALLAST

design, color coded for ease of installation.

BLACK RED TAP

H.P.S. STARTER WHITE

LINE

TORK 93

ORDERING INFO CATALOG NO.

UPC CODE

TRP-1**

82032

TRP-2**

82033

TRP400*

82132

TRP402*

82133

TRP800*

82135

TRP802*

82136

DESCRIPTION

Single Transformer Relay Powerpack Single Transformer Relay Powerpack Four Transformer Relay Powerpack Four Transformer Relay Powerpack Eight Transformer Relay Powerpack Eight Transformer Relay Powerpack

INPUT VOLTAGE

120VAC 277VAC 120VAC 277VAC 120VAC 277VAC

SURGE SUPPRESSOR FOR HIGH ELECTRICAL NOISE

EASY INSTALLATION: Universal 3 wire

DIGITAL CONTROLS

ENCLOSURE: Metal NEMA 1 Indoor enclosure (see page 153 for enclosure dimensions).

*Not for use with occupancy sensors. **For replacement parts only. For newer style Transformer Relay Power Pack, see TRP-U on page 116.

WIRING DIAGRAMS

HIGH GRADE MATERIAL: All components are sealed with high grade die-electric material to protect against contaminants and other adverse environmental conditions.

WEIGHT: 7 oz.

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

COMMON

CENTER CONTACT LAMP SHELL

APPLICATIONS For high electrical noise interference, recommended for all digital controls.

ORDERING INFO CATALOG NO.

UPC CODE

DESCRIPTION

90058-1

81024

Surge Suppressor

TORK 94

IN-WALL TIMERS

FEATURES QUICK LOOK

SS720A SERIES

SPECIFICATIONS

24 HOUR OR 7 DAY DIGITAL IN-WALL TIME SWITCH

TIMING ACCURACY: Line frequency. INPUT VOLTAGE: 125VAC, 60Hz. WIRE SIZE: #14AWG. OPERATING TEMPERATURE: 32°F to +104°F (0°C to +40°C).

APPLICATIONS

SS700Z

SS721Z

SS720A

701A

SSA

SSA-R24

SS

D1060 D212

A

C

Page No.

99

99

98

101

102

102

103

104

105

106

Timer Type

7 Day Digital

7 Day Digital

7 Day Digital

24 Hour Mechanical

Auto OFF Digital

Auto OFF Digital

Auto OFF Electronic

Auto OFF Electronic

Auto OFF Mechanical

Auto OFF Mechanical

Voltage

120/277

120/277

120

120

120/277

24

24/120/ 208-240/277

120

ON

1 min.

1 min.

1 min.

30 min.

OFF

1 min.

1 min.

1 min.

30 min.

Minimum Settings

5 min-12 hr 5 min-12 hr 10-60 min. 1 min-18 hr 10 min-8 hr 10 min-8 hr 2-12 hr

Outdoor security lighting Interior lights for lived-in look Fans and motors Appliances

125/250/277 125/250/277 Various 2 min-12 hr

Various 2 min-12 hr

ORDERING INFO Manual Override

Yes

Yes

Sunrise/Sunset

Yes

Yes

ON/OFF Set Points

10 Pair

10 Pair

Yes

Yes

SCHEDULING: 7 ON and OFF pairs of set points for individual programs on each day of the week. Minimum setting is 1 minute. 7 Pair

24

Flash Warning

TORK 97

Capacitor

Capacitor

Battery

Switch Type

SPST

SPST

SPST

Resistive Ratings

16A

16A

15A

SPST

NEW!

CATALOG NO.

UPC CODE

INPUT SUPPLY (VAC) 60 Hz

COLOR

SS720A

14017

120

White

SS720AA

14018

120

Light Almond

RANDOM MODE: Varies ON and OFF times to create "lived in" look when away. Yes

Audible Warning

Power Outage Backup

FEATURES

Yes

Yes

Yes

Capacitor

Capacitor

SPST

15 & 20A 800W/1200W

Yes

DAYLIGHT SAVING: Manual button push for one hour adjustment.

Yes

MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes.

CONTACT RATINGS TYPE

VOLTAGE

RATING

General Purpose

120VAC

15A

WIRING: Requires a neutral.

Resistive

120VAC

15A

CLOCK FORMAT: AM/PM.

Tungsten

120VAC

15A

Motor

120VAC

1HP

Electronic Ballast

120VAC

500VA

SPDT

SPST or SPDT

SPST

SPST

SPST or DPST

POWER OUTAGE BACKUP: Rechargeable Ni-MI battery retains time and schedule.

1A

4A or 7.5A

15

20/10/10A

20/10/10A

WALL PLATE: Supplied with standard single gang decorator wall plate.

TORK 98

SS700Z & SS721Z SERIES

BACKUP WITHOUT BATTERY, ECO FRIENDLY!

NEW!

SUNSET / SUNRISE, ASTRONOMIC 7 DAY IN-WALL TIMER

SS700Z SERIES

TIMING ACCURACY: Line frequency.

energy

RATING

INPUT VOLTAGE: 120/277VAC, 50/60Hz.

Resistive

16A

120/277VAC

16A

WIRE SIZE: #12AWG input/output - #16AWG 3-way (remote).

Ballast

10A

120/277VAC

13A

Tungsten

8A

120VAC

8A

Pilot Duty

360VA

120VAC

720VA

Motor

1⁄2HP

120VAC

1HP

CALIFORNIA Title 24 ASHRAE 90.1

Outdoor security lighting Interior lights for lived-in look Fans and motors Appliances

SS721Z SERIES

VOLTAGE

TYPE

OPERATING TEMPERATURE: 32°F to +104°F (0°C to + 40°C).

responsible

APPLICATIONS

CONTACT RATINGS

SPECIFICATIONS

With wall plate (not included)

RATING

WIRING DIAGRAMS

ORDERING INFO

CONTACT RATINGS

CATALOG NO.

UPC CODE

INPUT SUPPLY (VAC) 50/60 Hz

SWITCH TYPE

COLOR

SS700Z

14019

120/277

SPST

White

SS700ZA

14020

120/277

SPST

Light Almond

SS721Z

14027

120/277

SPST

White

SS721ZA

14028

120/277

SPST

Light Almond

FEATURES SCHEDULING: 10 ON and OFF pairs of set points for individual programs on each day of the week. 11 day groups speed programming. Minimum setting is 1 minute. ASTRONOMIC: Sunset and sunrise times are adjustable from 10°- 60° Northern or Southern latitudes. Can be individually offset +/- 1-240 minutes for earlier or later operation. RANDOM MODE: Varies ON and OFF times to create lived in look when away. DAYLIGHT SAVING: Automatic adjustment (can be omitted). LEAP YEAR: Automatic Compensation. MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes.

MANUAL MODE: Does not run programs until set to AUTO (automatic) mode. VACATION MODE: No operation when away.

WIRING DIAGRAM: INSTALLATION SS721Z

EASY WIRING: SS700Z does not require a neutral, can be used as a 3-way switch. SS721Z Requires a neutral, can be used as a 3-way switch.

H

COMMERCIAL GRADE SPECS: Control lighting contactors and 277VAC loads. Compatible with CFL lamps.

Blue

Red

Black

Load White

CLOCK FORMAT: AM/PM. POWER OUTAGE BACKUP: Permanent schedule retention. Supercapacitor provides 2 days of real time backup.

Black

N

N

Ground

WIRING DIAGRAM: THREE-WAY INSTALLATION SS721Z Connect a wire inside the gang-box between Traveler A and Hot.

ORDERING INFO Green Black

Blue

Black

Traveler A

H

Black Red Traveler B

Load White

N

N

Ground

Green

IN-WALL TIMERS TORK 99

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

TORK 100

701A & 711A SERIES

SPECIFICATIONS SPECIFICATIONS

24 HOUR IN-WALL TIME SWITCH

INPUT VOLTAGE: 125VAC, 60Hz. WIRE SIZE: #14AWG.

SSA SERIES

SPECIFICATIONS

DIGITAL AUTO OFF IN-WALL TIME SWITCH

TIMING ACCURACY: .002%. INPUT VOLTAGE: 120/277 VAC, 50/60Hz.

OPERATING TEMPERATURE: 32°F to +104°F (0°C to +40°C).

APPLICATIONS

WIRE SIZE: #18AWG.

APPLICATIONS Offices, meeting rooms, library aisles Stock and equipment rooms Exhaust fans – work areas, utility rooms, bathrooms Hot tub heaters and circulating pumps Timed override lighting and HVAC for after hours and for loads controlled by electromechanical or digital time switches.

Porch or patio Doorway Pool Outdoor security lighting

ORDERING INFO CATALOG NO.

UPC CODE

INPUT SUPPLY

SSA100

14010

120/277 VAC

SSA200

14011

120/277 VAC

SSA100R-24

14014

24VAC/24VDC

SSA200R-24

14015

24VAC/24VDC

LCS115M

82082

OPERATING TEMPERATURE: 0°F to +100°F (-17°C to +37°C). TIME SETTINGS

OUTPUT CONTACTS

Minutes: 5, 15, 30 Hours: 1, 3, 6, 9, 12 Minutes: 10, 20, 40 Hours: 1, 11⁄2, 2, 4, 8 Minutes: 5, 15, 30 Hours: 1, 3, 6, 9, 12 Minutes: 10, 20, 40 Hours: 1, 11⁄2, 2, 4, 8 Momentary Switch for Override (white)

SPST SPST SPDT SPDT SPST

CONTACT RATINGS

CLOCK FORMAT: AM/PM marked on dial. WALL PLATE: Supplied with single gang wallplate.

INPUT SUPPLY (VAC) 60 Hz

8-IN-1 TIMING: Choose from 8 preset ON intervals.

COLOR

701A

10113

125

White

701AA

10118

125

Light Almond

711A

10114

125

White

MANUAL SCROLL-UP: Option allows adjustment in 10 minute intervals. FLASH WARNING: Optional flicker feature turns load off for 1 second, 2 minutes before end of timed cycle and again 1 minute before end of timed cycle.

CONTACT RATINGS TYPE

VOLTAGE

General Purpose

800W 800W 1200W 1⁄6HP

Pilot Duty 30V 1V min.

120VAC 30V 1V min.

240VA 1A 100µA

RATING 701A SERIES

711A SERIES

125 VAC

20A

15A

Resistive

125 VAC

20A

15A

Tungsten

125 VAC

1500W

1250W

Motor

125 VAC

1 HP

1⁄2HP

Ballast

SSA100/200

SSA100/200R-24

WIRING DIAGRAMS SSA100/200

AUDIBLE WARNING: Optional beep will sound every 12 seconds during the last 2 minutes of timed cycle.

BLACK

HOT

GREEN

120V GROUND

GREEN /YELLOW

277V GROUND

RED

TAMPER RESISTANT: Time ON interval preset hidden behind wall plate.

RED

EASY SET: Dip switches provide quick set-up of timing and options. EASY WIRING: No neutral needed, great for retrofit. BACKLIT DISPLAY: Numerical read-out of time remaining includes graphic bar showing time remaining in 10% increments. Stands out strongly in lighted and dark areas.

BLACK ORANGE BLUE GREY

REMOTE OVERRIDE

(+) 24VAC or (–) VDC

NC C NO

YELLOW YELLOW

SSA200R-24 USING TRP TRANSFORMER RELAY POWERPACK BLACK ORANGE BLUE GREY

REMOTE OVERRIDE

NC C NO

YELLOW YELLOW

LOW VOLTAGE

20 AMP LOAD

L

RED

WALL PLATE: Supplied with white standard single gang decorator wall plate. SSA-R24: Offers low voltage control with SPDT output and includes momentary input.

NEUTRAL

LOAD

RED

WIRING: Requires a neutral.

Motor

120VAC 120VAC 277VAC 120VAC

RED BLACK BLUE

N

BLACK

VACATION MODE: Set timer OFF with no change of tripper settings.

Tungsten

RED

BYPASS SWITCH: Slide switch for ON, OFF, or TIMER (automatic) operation.

NEW!

UPC CODE

RATING

TORK TRP

SCHEDULING: Minimum ON setting is 30 minutes. Dial has 48 captive trippers.

CATALOG NO.

VOLTAGE

WHITE

ORDERING INFO FEATURES

TYPE

FEATURES

L

IN-WALL TIMERS TORK 101

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

TORK 102

SS SERIES

SPECIFICATIONS

AUTO OFF IN-WALL TIME SWITCH

TIMING ACCURACY: ±5% @ 60° to 80°F.

D SERIES

SPECIFICATIONS SPECIFICATIONS

NEW!

ELECTRONIC AUTO OFF IN-WALL TIME SWITCH

TIMING ACCURACY: Line voltage. INPUT VOLTAGE: 120VAC, 60Hz.

INPUT VOLTAGE: 24/120/208-240/277VAC, 50/60Hz.

WIRE SIZE: #14AWG. OPERATING TEMPERATURE: 32°F to 122°F (0°C to 50°C).

WIRE SIZE: #18AWG. OPERATING TEMPERATURE: 0°F to +100°F (-17°C to +37°C).

APPLICATIONS

APPLICATIONS Whole house fans Indoor/Outdoor lighting Bathroom fans and lights Self storage

Bathroom fans and lights Indoor/Outdoor lighting Storage areas Hospitality areas

ORDERING INFO

ORDERING INFO FEATURES VARIABLE TIMING: Choose from 1 minute to 18 hours. FLASH WARNING: “F” suffix models with flicker feature turns load off for 1⁄2 second, 2 minutes before end of timed cycle and again 1 minute before end of timed cycle. AUDIBLE WARNING: “B" suffix model will buzz that every 12 seconds during the last 2 minutes of timed cycle. TAMPER RESISITANT: Time ON interval preset is hidden behind wall plate. EASY SET: Small screw driver adjustment provides quick set-up of timing. EASY WIRING: No neutral needed, great for retrofit.

CATALOG NO.

INPUT SUPPLY (VAC) 50/60Hz

WARNING BEFORE TIME OUT

SWITCH TYPE

SS20

14005 24/120/208-240/277

None

Single pole

SS20F

14008 24/120/208-240/277

*Flicker

Single pole

SS13F

14007 24/120/208-240/277

*Flicker

3-way

SS13B

14006 24/120/208-240/277

**Beep

3-way

*Flicker feature turns load OFF for ½ second, 2 minutes before end of timed cycle and again 1 minute before end of timed cycle. **Beep feature will begin a ½ second audible warning every 12 seconds during the last 2 minutes of timed cycle.

CONTACT RATINGS TYPE

SS13F & SS13B

3-WAY: SS13 SERIES replaces standard 3-way switch with no re-wiring. COLOR: White.

UPC CODE

SS20 & SS20F

FEATURES VARIABLE TIMING: Button push changes time ON setting. D1060M: 10, 20, 30, 60 minute. D212H: 2, 4, 8, 12 hour. LED DISPLAY: Indicator moves to new range as timer counts down. TAMPER RESISTANT: Time ON interval preset. EASY SET: No adjustments, just wire and go! WIRING: Requires a neutral. THREE COLORS: Ivory, Light Almond, White.

MINIMUM LOAD

CONTACT RATINGS

VOLTS

WATTS

.25-4.0A Resistive .25-4.0A Ballast* .25-4.0A Tungsten 1⁄8HP @ 120VAC 1⁄3HP @ 240VAC .50-7.25A Resistive .50-7.25A Ballast* .50-4.0A Tungsten 1⁄6HP @ 120VAC 1⁄2HP @ 204VAC

24 120 208 240 277 24 120 208 240 277

6 30 50 60 70 12 60 105 120 150

CATALOG NO.

UPC CODE

INPUT SUPPLY (VAC) 60Hz

TIME SETTINGS

OUTPUT CONTACTS

D212H

14021

120

Ivory

2, 4, 8, 12 HOURS

D212HA

14022

120

Light Almond

2, 4, 8, 12 HOURS

D212HW

14023

120

White

2, 4, 8, 12 HOURS

D1060M

14025

120

Ivory

10, 20, 30, 60 MINUTES

D1060LA

14024

120

Light Almond

10, 20, 30, 60 MINUTES

D1060MW

14025

120

White

10, 20, 30, 60 MINUTES

CONTACT RATINGS TYPE

VOLTAGE

RATING

General Purpose

120VAC

15A

Resistive

120VAC

1000W

Tungsten

120VAC

1000W

Motor

120VAC

1⁄4HP

*Not compatible with compact fluorescent lamps (CFL) and electronic fluorescent ballasts.

IN-WALL TIMERS TORK 103

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

TORK 104

A SERIES

SPECIFICATIONS

SPRINGWOUND AUTO OFF IN-WALL TIME SWITCH

INPUT VOLTAGE: 125/250/277VAC, 50/60Hz. TERMINAL SIZE: #12AWG.

C SERIES

SPECIFICATIONS

COMMERCIAL STYLE SRINGWOUND AUTO OFF IN-WALL TIME SWITCH

INPUT VOLTAGE: 125/250/277VAC, 50/60Hz. TERMINAL SIZE: #12AWG.

OPERATING TEMPERATURE: 32°F to 122°F (0°C to 50°C).

OPERATING TEMPERATURE: 32°F to 122°F (0°C to 50°C).

ORDERING INFO

APPLICATIONS Whole house fans Indoor/Outdoor lighting Bathroom fans and lights Self storage

CATALOG UPC NO. CODE 15 MINUTE MAX.

Wallplate not included

A515MH

15020

A515MHW

15120

A515M

15013

A515MW

15113

A515MA

15127

HOLD FEATURE

With Hold

APPLICATIONS COLOR

Ivory White Ivory

No Hold

Wallplate included

Ventilating fans HVAC Whirlpools Self storage Motors and pumps

White Light Almond

30 MINUTE MAX.

A530MH

15021

A530MHW

15121

A530M

15014

A530MW

15114

CONTACT RATINGS FEATURES

TYPE

VARIABLE TIMING: Twist knob for time ON setting. Time ON lengths from 15 minutes to 12 hour vary by model.

VOLTAGE

RATING

125VAC 250VAC 277VAC 125VAC 250VAC 277VAC

20A 10A 10A 20A 10A 10A

125VAC

7A

Resistive Inductive

HOLD FEATURE: Some models have position for constant ON.

Tungsten

EASY SET: No adjustments. Just wire and go! EASY WIRING: No neutral required. Great for retrofit! Use as single or in multi-gang box with no de-rating.

125VAC 250VAC

Motor

1HP 2HP

A530MA

15022

A560MHW

15122

A560M

15015

A560MW

15115

A502HHW

15123

A502H

15016

A502HW

15116

3

9

6

0

0

12

12

3

9

6

9

A506HHW

15125

A506H

15018

9

A506HW

15118

With Hold

No Hold

Ivory White

With Hold No Hold

With Hold No Hold

FEATURES VARIABLE TIMING: Twist knob for time ON setting. Time ON lengths from 15 minutes to 12 hour vary by model.

Ivory

HOLD FEATURE: Some models have position for constant ON.

White

EASY SET: No adjustments. Just wire and go!

White

EASY WIRING: No neutral required. Great for retrofit!

Ivory

SWITCH TYPE: SPST, except C460M and C412H – DPST

White

COLOR: Metal-brushed aluminum.

White

WALL PLATE: Includes real metal wall plate with screw mounting, to add extra security for commercial applications.

Ivory

TYPE

VOLTAGE

RATING

125VAC 250VAC 277VAC 125VAC 250VAC 277VAC

20A 10A 10A 20A 10A 10A

Tungsten

125VAC

7A

Motor

125VAC 250VAC

1HP 2HP

Resistive Inductive

3

A512HH

15026

A512HHW

15126

A512H

15019

A512HW

15119

9

0 3

21

CAUTION: This timer is not to be used in precision timing applications where inaccurate timing could have dangerous consequences (i.e. sun lamp, sauna, etc.). 6

15501

HOLD FEATURE

No Hold

30 MINUTE MAX.

C530M

15503

No Hold

60 MINUTE MAX.

NEW!

C560M

15505

No Hold

C560MH

15506

With Hold

C460M*

15011

No Hold

2 HOUR MAX.

C502H

15507

No Hold

6 HOUR MAX.

C506H

15511

No Hold

12 HOUR MAX.

21

T OR K

1

C515M

White

With Hold

Ivory NEW!

White

C512H

15513

No Hold

C512HH

15514

With Hold

C412H*

15010

No Hold

*DPST switch type.

1

2

CATALOG UPC NO. CODE 15 MINUTE MAX.

12 HOUR MAX.

0 1

6

2

Light Almond

ORDERING INFO

CONTACT RATINGS

1

T OR K

2

White

6 HOUR MAX.

POT

2

0 12

No Hold

2 HOUR MAX.

POT

0

White Ivory

15128

A560MH

COLOR: Ivory, Light Almond, White.

12

Ivory

60 MINUTE MAX.

SWITCH TYPE: SPST. WALL PLATE: Fits standard or decorator style wall plates, see below (not included).

With Hold

9

No Hold

Ivory White

CAUTION: This timer is not to be used in precision timing applications where inaccurate timing could have dangerous consequences (i.e. sun lamp, sauna, etc.).

All A Series timers have SPST switch type.

IN-WALL TIMERS TORK 105

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

TORK 106

OCCUPANCY SENSORS

OSWS SERIES

SENSOR TECHNOLOGY & PLACEMENT GUIDE TECHNOLOGY PIR AND ULTRASONIC

A Passive Infrared Sensor (PIR sensor), is a device that measures infrared radiation (IR), or heat, from objects in its field of view. Because it only receives information, it is considered passive. The IR sensor views a human body as an IR generating object. The lens of the occupancy sensor breaks up the field of view into IR sensitive bands. The occupancy sensor is designed to only react when heat is sensed moving from band to band. For PIR occupancy sensors to work object must have direct “line of sight” to the PIR sensor.

PLACEMENT GUIDELINES

PIR SENSOR, DECORATOR STYLE IN-WALL OCCUPANCY SENSOR

• Designed for ceiling mounting at a height of 8-10 feet (mounting sensor at greater heights decreases the sensitivity to motion, while lower mounting height will decrease range). • The sensor needs a visually unobstructed view of the normally occupied workspace and entry door(s). • Avoid sensor placement with a direct view out a doorway. Placing the sensor offset from the center and away from the door is recommended. Both technologies show higher sensitivity closer to the sensor to allow small • If the occupant cannot see a PIR sensor from their normal work movements to be noticed. Sensitivity reduces further away from the sensor and position, the sensor will not be able to detect their presence. may require a walking step to activate the sensor. • File cabinets, partitions, or walls are typical types of obstructions. If there are other obstructions between the sensor and the occupant, an ultra-sonic or dual technology ceiling sensor is recommended. • When the light level feature is used, mount within 15 feet of the widows or skylight and avoid mounting the sensor close to lighting WALL SENSOR fixtures. A Wall Switch Sensor provides a 180° coverage pattern, extending outward • Place the sensor no closer than 5 feet to an HVAC airCEILING duct whenAND usingWALL OCC SENSOR SENSING PATTERNS CEILING AND WALL OCC SENSOR SENSING PATTERNS from the sensor. This will allow for instant turn ON when an occupant enters the dual technology sensors. space. Total area covered will be over 400 square feet. • Open office designs encourage placement of the sensors to allow overlapping coverage of small motion range and a clear view into • Proper placement gives the sensor a clear line of sight to the entry door each cubicle. Walking step motion may cover the entry to the space. without viewing the hallway. Dual technology units provide added sensitivity to small motion. • The occupant must be able to see the sensor from their normal work position otherwise the sensor will not be able to detect their presence. • For offices where there are other obstructions between the sensor and the occupant or the entry door, a ceiling sensor is required. An Ultrasonic Sensors (US sensor) is a technology that works on a principle similar to radar or sonar. It is an active technology that sends and receives. It emits an inaudible high-frequency sound wave and evaluates the echo which is received back after bouncing around in the room. This allows the sensor to evaluate the whole room and can “look” over walls and obstructions to identify movement.

PLACEMENT GUIDELINES

CEILING AND WALL OCC SENSOR SENSING PATTERNS

CONTACT RATINGS: OSWS9P-120: 1000W Ballast, 800W Incandescent, 1⁄6HP at 120VAC. OSWS9P-277: 1800W Ballast at 277VAC. OSWS9PD & OSWS9PDM: 1000W Ballast, 800W Incandescent, 1⁄6HP at 120VAC, 1800W Ballast at 277VAC.

responsible

energy

CALIFORNIA Title 24

CEILING SENSOR

A Ceiling Sensor provides a 360° coverage pattern of up to 1200 square feet when using passive infrared only. When using dual technology the coverage pattern extends to over 2000 square feet. Barriers within the space that block line-of-sight to sensor detection will decrease coverage area when using passive infrared by itself, ultrasonic dual technology will allow the sensor to get around the obstructions.

SPECIFICATIONS

ASHRAE 90.1

APPLICATIONS

ADJUSTABLE TIME DELAY: 30 seconds - 30 minutes.

Offices and hotels Classrooms Conference rooms Lavatories Hallways

OPERATING TEMPERATURE: 32° to 131°F (0° to 55°C). MOUNTING: Box mount.

FEATURES OSWS9P-120, OSWS9P-277 & OSWS9PD: OPERATION: Automatic ON and automatic OFF based on occupancy detection. OFF DELAY: Selectable from 30 seconds to 30 minutes. MANUAL OVERRIDE: Includes ON and OFF switch. EASY WIRING: No neutral required. Great for retrofit. OSWS9PD ALSO INCLUDES: SENSITIVITY ADJUSTMENT: For PIR range. DAYLIGHTING MODE: Adjustable level to keep lights OFF even when occupancy is sensed if adequate light exists in the room from windows or skylights.

ORDERING INFO CATALOG NO.

UPC CODE

DESCRIPTION

OUTPUT CONTACTS

OSWS9P-120

82077

PIR in-line wall switch

120VAC

OSWS9P-277

82078

PIR in-line wall switch

277VAC

OSWS9PD

82079

120/277VAC

OSWS9PDM

82080

PIR in-line wall switch with ambient light sensor PIR in-line wall switch manually activated

WIRING & COVERAGE DIAGRAMS Wall Mounting Box

OSWS9PDM - VACANCY SENSOR: OPERATION: Manual push button on and then automatic OFF.

LINE (Black)

OFF DELAY: Selectable from 30 seconds to 30 minutes.

LOAD (Red)

SENSITIVITY ADJUSTMENT: For PIR range. DAYLIGHTING MODE: Adjustable level to keep lights OFF even when occupancy is sensed if adequate light exists in the room from windows or skylights. MANUAL OVERRIDE: Includes ON and OFF switch.

120/277VAC

GND (Green)

Top and Side Coverage Pattern Diagrams

EASY WIRING: No neutral required.

35'

16' 180° Coverage 15°

4.0' 15° 35'

TORK 109

TORK 110

OSC15PLS

SPECIFICATIONS

PIR SENSOR, WITH AMBIENT LIGHT OVERRIDE, MULTI-VOLTAGE INTEGRAL POWERPACK, CELING MOUNTED OCCUPANCY SENSOR

VOLTAGE: 120 - 347VAC. ADJUSTABLE LIGHT LEVEL: 5FC - 200FC.

responsible

energy

CALIFORNIA Title 24 ASHRAE 90.1

ADJUSTABLE TIME DELAY: 30 seconds 30 minutes (DIP switch). TEST MODE: 5 seconds, upon initial power-up or DIP switch reset.

APPLICATIONS

PIR COVERAGE: 1200 sq. ft.

Offices and hotels Classrooms Conference rooms Lavatories Hallways

sensitivity adjustment: Full or 50% low (DIP switch). operating temperature: 32° to 131°F (0° to 55°C). mounting: Ceiling or box mount. contacts: SPST dry contacts.

FEATURES

contact ratings: 800W Incandescent, 1000W ballast at 120VAC. 1800W Ballast at 277VAC. 2200W Ballast at 347VAC.

OPERATION: Automatic ON and automatic OFF based on occupancy detection.

OSC12PL & OSC5PL

SPECIFICATIONS VOLTAGE: 24VDC.

PIR SENSOR CELING MOUNTING OCCUPANCY SENSORS

UPC CODE

INPUT SUPPLY

COVERAGE (FEET)

DESCRIPTION

OSC15PLS

82076

120-347VAC

1200

WHITE

WIRING & COVERAGE DIAGRAMS

OSC15PLS SENSOR

N

LOAD

WHITE (NEUTRAL) BLACK (LINE)

RED

RED

ADJUSTABLE LIGHT LEVEL: 10FC - 150FC.

Offices Classrooms Conference rooms Lavatories Hallways

ADJUSTABLE TIME DELAY: 5 seconds - 30 minutes (DIP switch). TEST MODE: 5 seconds, upon initial power-up or DIP switch reset. PIR COVERAGE: 1200 sq. ft.

OSC5PL / OCCUPANCY SENSOR ASSORTED SENSING PATTERNS OSC5PL / OCCUPANCY SENSOR ASSORTED SENSING PATTERNS

FEATURES

18ft

SENSITIVITY ADJUSTMENT: Full or 50% low (DIP switch).

18ft

MOUNTING: Ceiling or box mount.

OPERATION: Automatic ON and automatic OFF based on occupancy detection.

DAYLIGHTING MODE: Selectable to keeps lights off when occupancy is sensed if adequate light exists in the room from windows or skylights.

CATALOG NO.

POWER SUPPLY: TRP-U Power Pack (up to 6 units).

CALIFORNIA Title 24

APPLICATIONS

OFF DELAY: Selectable from 30 seconds to 30 minutes.

POWER SWITCHING: Built-in power pack for direct line voltage control.

energy

ASHRAE 90.1

OFF DELAY: Selectable from 30 seconds to 30 minutes.

ORDERING INFO

CURRENT CONSUMPTION: 9mA.

responsible

OPERATING TEMPERATURE: 32° to 131°F (0° to 55°C).

ORDERING INFO

12ft COVERAGE (FEET)

12ft

ECOSETTING: Learns typical use patterns and adjusts the OFF delay for the most efficient time.

CATALOG NO.

UPC CODE

INPUT SUPPLY

WALK-THROUGH MODE: Selectable to turn lights OFF after only 3 minutes. If no activity is detected after 30 seconds of occupancy detection, lights turn OFF.

OSC5PL

82083

24VDC

500

White

OSC12PL

82081

24VDC

1200

White

TRP-U

82030

120/277VAC

DAYLIGHTING MODE: Selectable to keep lights OFF when occupancy is sensed if adequate light exists in the room from windows or skylights.

LCS115M

82082

DESCRIPTION

Power Pack Momentary Switch

COVERAGE DIAGRAMS

PRESENTATION MODE: Optional MANUAL OFF by an accessory wall switch (LCS115M). Sensor will keep lights OFF while movement in room is detected, then return to automatic ON after 5 minutes.

DIP SWITCH Sensitivity

Time Delay

1

50%

VACANCY MODE: Optional MANUAL ON by an accessory wall switch (LCS115M) and then automatic OFF.

100% Walk Through

3

Audible Alert

4

Enabled Visible Alert

Vacancy

6

Disabled Enabled

WARNING BEFORE OFF: Optional visual flash warning and/or audible beep warning one minute before turn OFF.

Enabled

20 Minutes 25 Minutes

Hold ON

30 Minutes

Disabled

OFF

ON

8

Disabled

15 Minutes

Enabled

7

Disabled

30 Seconds 5 Minutes 10 Minutes

5

Disabled

MANUAL OVERRIDE: Optional manual control by an accessory wall switch (LCS115M) for ON and OFF.

2

5 Sec/EcoSet

Factory Setting

9

Enabled

OSC5PL

OSC12PL

PLUG TERMINAL: Quick disconnect for sensor. POWER SWITCHING: Transformer relay power pack (TRP-U) required to power sensor and provides line voltage switching. (see page 116 for product information).

OCCUPANCY SENSORS TORK 111

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

22 6.7

11

7

3

3

7

11

TORK 112

OSC2OUP

DUAL TECHNOLOGY CELING MOUNTED PIR/ULTRASONIC OCCUPANCY SENSOR

SPECIFICATIONS VOLTAGE: 24VDC. energy

CALIFORNIA Title 24 ASHRAE 90.1

APPLICATIONS

PIR COVERAGE: 1500 sq. ft. (adjustable). SENSITIVITY ADJUSTMENT: Individual setting range for ultrasonic of 50% and PIR of 75%. ULTRASONIC OUTPUT: 32Hz MOUNTING: Ceiling or box mount.

OPERATION: Automatic ON and automatic OFF based on occupancy detection. OFF DELAY: Selectable from 8 to 40 minutes. ECOSETTING: Learns typical use patterns and adjusts the OFF delay for the most efficient time.

POWER SWITCHING: Transformer relay power pack (TRP-U) is required to power sensor and provide line voltage switching (see page 116 for product information).

ADJUSTABLE TIME DELAY: 8 - 40 minutes.

US COVERAGE: 2000 sq. ft. (adjustable).

FEATURES

TORK 113

VOLTAGE: 24VDC. responsible

energy

CALIFORNIA Title 24 ASHRAE 90.1

APPLICATIONS

HUMIDITY: 0 to 95% R.H. non-condensing for indoor use only.

OFF DELAY: Selectable from 8 to 40 minutes.

ORDERING INFO CATALOG NO.

UPC CODE

INPUT SUPPLY

COVERAGE (FEET)

DESCRIPTION

OSCS20UP

82075

24VDC

2000 ft US 1500 ft PIR

White

TRP-U

82030

120/277VAC

Power Pack

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

POWER SWITCHING: Transformer relay power pack (TRP-U) is required to power sensor and provide line voltage switching (see page 116 for product information).

ADJUSTABLE TIME DELAY: 8 - 40 minutes.

SENSITIVITY ADJUSTMENT: Manual setting range of 50%. ULTRASONIC OUTPUT: OSC5U: 40kHz OSC10U/OSC20U: 32kHz MOUNTING: Ceiling or box mount. OPERATING TEMPERATURE: 32° to 104°F (0° to 40°C). HUMIDITY: 0 to 95% R.H. non-condensing for indoor use only.

ECOSETTING: Learns typical use patterns and adjusts the OFF delay for the most efficient time. MOTION INDICATION: Green for ultrasonic motion. Indicator may be disabled.

POWER SUPPLY: TRP-U Power Pack (up to 4 units).

US COVERAGE: 2000 sq. ft. (adjustable).

FEATURES OPERATION: Automatic ON and automatic OFF based on occupancy detection.

CURRENT CONSUMPTION: 33mA.

TEST MODE: 8 seconds, upon initial power-up for 1 hour.

Offices and hotels Classrooms Conference rooms Lavatories Hallways

OPERATING TEMPERATURE: 32° to 131°F (0° to 55°C).

COVERAGE DIAGRAMS

OCCUPANCY SENSORS

SPECIFICATIONS

ULTRASONIC, CEILING MOUNTING OCCUPANCY SENSORS

POWER SUPPLY: TRP-U Power Pack (up to 3 units).

TEST MODE: 8 seconds, upon initial power-up for 1 hour.

Offices and hotels Classrooms Conference rooms Lavatories Hallways

MOTION INDICATION: Red for infrared motion, Green for ultrasonic motion. Indicators may be disabled.

CURRENT CONSUMPTION: 33mA.

responsible

OSC SERIES

ORDERING INFO CATALOG NO.

UPC CODE

INPUT SUPPLY

COVERAGE (FEET)

DESCRIPTION

OSC5U

82072

24VDC

500 SQ FT

White

OSC10U

82073

24VDC

1000 SQ FT

White

OSC20U

82074

24VDC

2000 SQ FT

White

TRP-U

82030

120/277VAC

Power Pack

COVERAGE DIAGRAMS

TORK 114

ELS

TRP-U

SPECIFICATIONS

INDOOR LIGHT LEVEL ELECTRONIC CCUPANCY SENSOR

responsible

energy

VOLTAGE: 24VDC.

ASHRAE 90.1

LOAD REQUIREMENTS: Ballast 20amp @120/277VAC. Incandescent 20amp@120VAC. Motor 1HP @120/240VAC. Output 150mA @24VDC (with relay connected).

POWER SUPPLY: TRP-U Power Pack (up to 4 units). operating temperature: 50° to 104°F (10° to 40°C).

APPLICATIONS

mounting: Ceiling or box mount.

Offices Classrooms Conference rooms Hallways

LOW VOLTAGE INPUT: Control ON: 12 - 24VDC Hold ON: 12 - 24VDC Hold OFF: 12 - 24VDC

Power and switching for occupancy sensors Power and switching for SSA R-24 series BAS input compatible Demand shedding applications Device override to hold on Momentary switched override Low voltage 3-way wiring

FEATURES DAYLIGHTING CONTROL: Turns OFF when sufficient daylight present. ADJUSTABLE LIGHT LEVEL: 10FC - 250FC (DIP switch).

FEATURES

EASY MOUNTING: Low voltage Class 2 wiring allows recommended mounting about 3 feet from daylight sources.

OPERATION: Switches line voltage loads ON/OFF based on a contact closure from an occupancy sensor, AUTO OFF switch, or relay.

PRESET ON DELAY: 30 seconds prevents false triggering.

VOLTAGE: 120/230/277VAC, 50/60Hz.

CURRENT CONSUMPTION: 9mA.

CALIFORNIA Title 24

APPLICATIONS

ADJUSTABLE OFF DELAY: Set from 3 to 15 minutes.

SPECIFICATIONS

INTELLEGENT POWER PACK

ORDERING INFO CATALOG NO.

UPC CODE

INPUT SUPPLY

DESCRIPTION

ELS-1

82049

24VDC

Indoor Daylight Sensor

TRP-U

82030

120/277VAC

Power Pack

operating temperature: 32° to 131°F (0° to 55°C).

ORDERING INFO

INTELLEGENT INPUT: Three additional input wires: 1. Hold OFF for demand shed control. 2. Hold ON override of local devices such as sensors. 3. Momentary switch input for remote override.

CATALOG NO.

UPC CODE

INPUT SUPPLY

DESCRIPTION

TRP-U

82030

120/277VAC

Power Pack

MULTI-VOLTAGE: Tri-voltage input for flexibility.

LCS115M

82082

QUICK MOUNTING: Snaps into 1⁄2" box KO.

WIRING DIAGRAMS

MOUNTING: Box mount to 1⁄2" KO.

Momentary Switch

WIRING DIAGRAMS

ON 1 2 3 4 5 6 7

Power Pack 277V Model TRP2 or Power Pack 120V Model TRP1

New Extension Box

Existing Junction Box

TRP-U LOW VOLTAGE WIRING

New Cover With 1/2 K.O. Provision PHOTO SENSOR ORIENTATION ARROW UNDER IVORY COVER

PROGRAMMABLE 7-SECTION SLIDE SWITCH FOOT CANDLE SELECTION* +

1 2 3 4 56 FOR7

SLIDE

FOOT CANDLE

#1

10FC

Warehouse

#2

25FC

#3

50FC

#4

75FC

Corridors Machine equipment display showroom (such as automobile and farm equipment) LOBBY (such as airport waiting area). Classrooms, common office areas

#5

100FC

Drafting rooms

#6

150FC

Retail display areas

250FC

High critical areas, product sorting and grading, paint quality control.

#7

Bend Tabs After Inserting in K.O. Hole New Extension Box Only Used When Low Voltage Wiring Has to be Enclosed

*Slide only one switch to ON for selection, all other switches remain OFF.

OCCUPANCY SENSORS TORK 115

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

TORK 116

PLUG-IN TIMERS

400A SERIES

400D SERIES

INDOOR GENERAL PURPOSE 1875W MECHANICAL MULTIPLE ON/OFF TIMERS

INDOOR GENERAL PURPOSE 1800W DIGITAL PROGRAMMABLE ON/OFF TIMERS

NEW! responsible

energy

CALIFORNIA Title 24 ASHRAE 90.1

401A

APPLICATIONS

460D

APPLICATIONS 405A

Lamps, radios, televisions Appliances Automatically turn ON/OFF items in the home, gives the home a "lived in" look while away.

Lamps, radios, televisions Appliances NEW!

455D

Automatically turn ON/OFF items in the home, gives the home a "lived in" look while away.

402A

FEATURES

454D

NEW!

422A

FEATURES

457Z

REPEAT SCHEDULE: Daily.

REPEAT SCHEDULE: 7 day programming.

VARIABLE TIMING: Multiple ON/OFF times.

VARIABLE TIMING: 460D, 454D, 455D: Manual Daylight Savings adjustment. Random mode for lived-in look. Manual Override ON/OFF.

ON/OFF: Manual ON/TIMER switch. ENERGY SAVINGS: Works with CFLs and LED lamps.

403A

457Z: Turns ON at Sunset; turns OFF at Sunrise or other times; automatic DST adjustment; Random Mode for lived-in look; Manual Override ON/OFF. BACKUP: Battery back-up. ENERGY SAVINGS: Works with CFLs and LED lamps. ACCURACY: Digital accuracy to 1 minute.

ORDERING INFO CATALOG NO.

UPC CODE

401A

16001

402A

16002

403A

16013

405A

16014

422A

16019

ORDERING INFO

RATINGS

125 VAC, 15A, 1875W Resistive 125VAC, 10A, 1250W Tungsten 125VAC, 1⁄3HP

125VAC 15A, 1875W Resistive 125VAC 500W Tungsten 125VAC TV-4

NO. OF OUTLETS ( )

TYPE OF PLUG

DESCRIPTION

VARIABLE TIMING SEGMENTS

CATALOG NO.

UPC CODE

1

Polarized

Multiple ON/OFF Lighting Timer

15 minute

460D

16017

1

Grounded

Heavy Duty 24 hour Timer

15 minute

454D

16009

1

Polarized

Powerful & Compact Automatic Timer

30 minute

455D

16015

2

Grounded

Heavy Duty 15 AMP Automatic Timer

15 minute

1

Grounded

Heavy Duty 24 hour 15AMP Timer

30 minute

NOTE: " " = Indicates outlet location.

457Z

16016

RATINGS

120VAC, 15A, 1800W General Purpose 120VAC, 15A, 1800W Resistive 120VAC, 1000W Tungsten 120VAC, 1⁄3HP, TV-5 120VAC, 15A, 1800W General Purpose 120VAC, 15A, 1800W Resistive 120VAC, 960W Tungsten 120VAC, 1⁄3HP TV-5

NO. OF OUTLETS ( )

TYPE OF PLUG

DESCRIPTION

1

Polarized

Daily Programmable Digital Timer

24 ON/OFFs

VARIABLE TIMING SEGMENTS

1

Grounded

Daily Programmable Digital Timer

Different schedule for each day of the week.

2

Grounded

Daily Programmable Digital Timer

Multiple ON/OFFs 20 ON/OFFs

2

Grounded

Ultimate Plug-In 2-Outlet Timer

Different schedule for each day of the week. ON at Sunset OFF at Sunrise

NOTE: " " = Indicates outlet location.

PLUG-IN TIMERS TORK 119

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

TORK 120

600D SERIES

600A SERIES

OUTDOOR NEW! GENERAL PURPOSE 1875W 7 DAY DIGITIAL WITH PHOTOCELL, 7 DAY DIGITAL OUTDOOR TIMERS

OUTDOOR GENERAL PURPOSE 1875W MECHANICAL PLUG-IN PHOTOCELL COUNTDOWN TIMERS

APPLICATIONS

responsible

energy

CALIFORNIA Title 24 ASHRAE 90.1

Photocell

APPLICATIONS

Landscape or Christmas lighting Controls small pumps, fountains, motors

Landscape and Christmas lighting Control small pumps, fountains, motors, etc. Energy saving

601A 602A

621D & 631D

(621D without photocell)

611A

611D

FEATURES

FEATURES

REPEAT SCHEDULE: Daily.

REPEAT SCHEDULE: 7 day programming.

VARIABLE TIMING: Multiple ON/OFFs, Manual ON/ TIMER switch.

VARIABLE TIMING: Manual Daylight Savings adjustment. Random mode for lived-in look. Manual ON/TIMER switch. Multiple ON/OFF for each day of the week.

PHOTO TIMER: Two styles 652A - Dial setting. ON at dusk and OFF 2, 4, 6, or 8 hours later. 654A - Digital setting. ON dusk and OFF 1 to 9 hours later or at random times.

652A

BACKUP: Battery back-up. ACCURACY: Digital accuracy to 1 minute.

ENERGY SAVINGS: Works with CFLs and LED lamps.

654A

ORDERING INFO CATALOG NO.

UPC CODE

601A

16020

602A

16021

611A*

16022

652A

16026

654A

16025

RATINGS

125 VAC, 15A, 1875W General Purpose 125VAC, 15A, 1875W Resistive 125VAC, 10A, 1250W Tungsten 125VAC, 1⁄2HP 125VAC, 15A, 1875W General Purpose 125VAC, 15A, 1875W Resistive 125VAc, 650W Tungsten 125VAC, 1⁄3HP, TV-5

NO. OF OUTLETS ( )

TYPE OF PLUG

DESCRIPTION

1

Grounded Mechanical Outdoor Timer, with18" cord

2

Grounded Mechanical Outdoor Timer, with18" cord

1

Wall Mountable Grounded Mechanical Outdoor Timer, with 24" cord

2

Grounded

Photocell Outdoor Timer with 6.5" cord

2

Grounded

Photocell Outdoor Timer with 6.5" cord

VARIABLE TIMING SEGMENTS

15 minutes Multiple ON/OFFs 15 minutes Multiple ON/OFFs 15 minutes Multiple ON/OFFs Photo ON Dawn or timed OFF Photo ON Dawn or timed OFF

*611A: 1⁄3HP

PHOTOCELL: 611D and 631D have built-in photocell to always turn ON at dusk and OFF at dawn. Add a time OFF schedule

655D

655D Remote

WIRELESS REMOTE: 655D receives ON/OFF signal up to 80 feet away.

ORDERING INFO CATALOG NO.

UPC CODE

611D

16018

621D

16056

631D 655D*

RATINGS

NO. OF OUTLETS ( )

TYPE OF PLUG

1

Grounded

2

Grounded

16027

125 VAC, 15A, 1875W General Purpose 125VAC, 15A, 1875W Resistive 125VAC, 1000W Tungsten 125VAC, 8A Ballast 125VAC, 1⁄2HP

2

Grounded

16042

125VAC, 5A, 625W Resistive 125VAC, 600W Tungsten

2

Grounded

DESCRIPTION

Wall Mountable Photocell & 7 Day Digital 2-in-1 Timer, with 24" cord Wall Mountable, 7 Day Digital Timer, with 18" cord Wall Mountable Photocell & 7 Day Digital 2-in-1 Timer, with 18" cord Remote control indoor/outdoor receiver

VARIABLE TIMING SEGMENTS

Photo ON Dawn or timed OFF Multiple ON/OFFs for each day of the week Photo ON Dawn or timed OFF Handheld remote ON/OFF

* ETL listed for U.S. and Canada.

NOTE: " " = Indicates outlet location.

NOTE: " " = Indicates outlet location.

PLUG-IN TIMERS TORK 121

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

TORK 122

800 SERIES

NEW! OUTDOOR GENERAL PURPOSE 1875W MECHANICAL & DIGITAL STAKE TIMERS

APPLICATIONS Landscape and Christmas lighting Other outdoor lighting Energy saving 803B 806B

FEATURES REPEAT SCHEDULE: Mechanical timer 24 hours. Digital timer 7 day programming. 806D

MECHANICAL TIMING: Multiple ON/OFFs, Manual ON/ TIMER switch. DIGITAL TIMING: Manual ON/TIMER switch. Multiple ON/OFF for each day of the week. PHOTOCELL: 806D has optional built-in photocell to always turn ON at dusk and OFF at dawn or 1 to 12 hours later. ENERGY SAVINGS: Works with CFLs and LED lamps.

ORDERING INFO CATALOG NO.

UPC CODE

803B

16057

806B

16037

806D

16038

RATINGS

125VAC, 15A, 1875W Resistive 125VAC, 10A, 1250W Tungsten

125VAC, 15A, 1875W Resistive

NO. OF OUTLETS ( )

TYPE OF PLUG

3

Grounded

6

Grounded

6

Grounded

DESCRIPTION

VARIABLE TIMING SEGMENTS

Mechanical Outdoor Stake Timer, with 2' cord Mechanical Outdoor Stake Timer, with 2' cord. 3 timed outlets and 3 untimed.

15 minutes Multiple ON/OFFs 15 minutes Multiple ON/OFFs Multiple ON/OFFs for each Digital Outdoor Stake Timer, with 6' cord. 3 day of the week or Photo timed outlets and 3 untimed. ON and Dawn or 1-12 hours OFF.

NOTE: " " = Indicates outlet location.

PLUG-IN TIMERS TORK 123

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

TORK 124

TORKALERT



MECHANICAL STROBE HORNS

ALARM SOUNDS

MULTI-TONE ELECTRONIC HORNS

ALARM TONE

BELL HI-LO CHIME SINGLE STROKE BELL HORN 3 BEEPS, PAUSE SIREN SLOW WHOOP

24VDC &115VAC

APPLICATIONS

APPLICATIONS

TA880-N5

High performance for industrial signaling applications. Offers high sound output, low current draw and dependable operation. Strobes use xenon flashtube, ideal for maximum efficiency and reliability.

TA5508H-G1

ORDERING INFO CATALOG NO.

UPC CODE

INPUT VOLTAGE

INPUT CURRENT (AMPS)

dB @10 FEET

CANDELA

TA880-N5

96015

120VAC

0.115

96

15

ALARM: Penetrating mechanical sound.

TA5508H-G1

96071

24VDC

.059

strobe only

15/75

WIRING: Low current draw.

NOTE: TA880-N5 For outdoor use, unit must be mounted in a TA-WBBF outdoor backbox. See page 138 for ordering. TA5508H-G1 for indoor mounting only.

FEATURES

MOUNTING: 4" square surface mounting.

TA875-1G1

For indoor and outdoor use. Superior sound penetration for various room conditions. Screw terminals accept #12AWG.

MECHANICAL HORNS

FEATURES OPERATING TEMPERATURE: TA-MTS: -31˚F to +150˚F (-35˚C to +66˚C). DIMENSIONS AND MOUNTING: TA-MTS: 41⁄18”H x 41⁄8”W x 317⁄32”D Can be mounted on celing or wall. TA875-1G1: 43⁄4”H x 43⁄4”W x 13⁄8”D 1 gang, 2 gang or 4" square backbox.

TA875-1G1 24VDC HORN CURRENT (AMPS)

TA-MTS

ALARM TONE

HORN BELL HORN 2 CODE 3 HORN CODE 3 TONE SLOW WHOOP SIREN HI-LO

TYPICAL dB @10 FEET

0.020 0.025 0.028 0.026 0.023 0.023 0.040 0.040

91 96 93 93 97 97 95 96

TA-MTS 115VAC HORN AMPS @ 120VAC TYPICAL dB @10 FEET HIGH STANDARD HIGH STANDARD OUTPUT OUTPUT

0.050 0.041 0.050 0.050 0.042 0.050 0.045 0.042

0.042 0.039 0.040 0.042 0.040 0.042 0.041 0.039

85 82 85 82 79 85 85 82

82 75 79 75 75 82 82 79

ORDERING INFO CATALOG NO.

UPC CODE

INPUT VOLTAGE

DESCRIPTION

TA875-1G1

97641

20-31VDC, 24VDC

Multi-tone Electric Horn

TA-MTS

97674

115 VAC

Multi-tone Electric Horn

HEAVY DUTY BELLS

4", 6", 10" DIAMETERS AC VIBRATING BELLS

ORDERING INFO

APPLICATIONS

CATALOG NO.

Loud tone with typical decibel output of 103 dB. Low frequency resonation for strong penetration of noisy areas like boiler rooms, water pumping stations, elevators and air compressor rooms.

UPC CODE

INPUT VOLTAGE

INPUT CURRENT (AMPS)

APPLICATIONS

SURFACE TYPE

TA874-N5

96023

120VAC, 60Hz

0.070

TA874-N5R (Red)

97613

120VAC, 60Hz

0.070

TA875-G1

97687

24VDC

0.035

For indoor or outdoor applications. High sound output, durable and dependable performance. Ideal for schools and hopsitals.

ORDERING INFO INPUT VOLTAGE CURRENT (AMPS)

dB @ 10 FEET

CATALOG NO.

UPC CODE

SHELL SIZE

TA340-4G5

96001

4”

24VAC

0.320

81-90 Dawn Mist

TA340-4N5

96002

4”

120VAC

0.065

81-90 Dawn Mist

TA340-6G5

96003

6”

24VAC

0.320

81-95 Dawn Mist

TA340-6N5

96004

6”

120VAC

0.065

81-95 Dawn Mist

COLOR

WITH WEATHERPROOF BACKBOX TA-WBBF UL LISTED FOR OUTDOOR USE

FEATURES

TA876-N5

INPUT VOLTAGE: Wide input voltage ratings for compatibility with unregulated power supplies.

HOUSING: Steel, painted Dawn Mist. Resonant grill design for high sound output.

WIRING: Screw terminals for convenient IN/OUT wiring. Low current draw for minimizing power supply and wiring cost.

MOUNTING: To indoor box TA-BBSF or outdoor box TA-WBBF, see accessories page 13*.

NOTE: Use TORK signal timers for 24 hour or 7 day scheduling, see page 85.

96026

120VAC, 60Hz

0.070

FEATURES TERMINAL SIZE: #12 - 22 AWG.

TA340-10G5

96005

10”

24VAC

0.320

84-98 Dawn Mist

WIRING: Screw terminals permit fast IN/OUT field wiring.

TA434-4N5

98005

4"

120VAC

0.065

81-95

Red

HOUSING: Steel gong and cast aluminum. See page 138 for dimensional drawings.

TA434-6N5

97521

6”

120VAC

0.065

81-95

Red

TA434-10N5

96522

10”

120VAC

0.065

84-98

Red

NOTE: Use TORK signal timers for 24 hour or 7 day scheduling, see page 85.

TORK ALERT ™ TORK 127

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

TORK 128

LIGHT DUTY AND GENERAL PURPOSE BELLS & BUZZER

WEATHERPROOF MOTOR DRIVEN SIREN

DIMENSIONS FRONT VIEW

8-1/4"

Power wires 2 feet long

APPLICATIONS

APPLICATIONS Designed to operate on either bell ringing transformers or batteries. Non-adjustable sound.

TA725

(2) 9/32" mounting holes

Mount siren (hardware not included) 15-3/8"

FRONT VIEW

For industrial and outdoor use. Ideal for evacuation and warning systems.

TA740

6-7/8"

7-1/2" dia. (2) nuts, loosen to adjust siren direction. 8-1/4"

FEATURES ALARM: Bell ringing, non-adjustable sound. DIMENSIONS FOR TA725: 3" H x 21⁄2" W x 1" D. MOUNTING: Fully enclosed sturdy steel bases and covers. Base and cover snap together, no screws required.

ORDERING INFO

FEATURES

CATALOG NO.

UPC CODE

SWITCH

VAC

VDC

AMPS

dB

TA740

96228

21⁄2” Gong

8-16

3-6

1

76 @ 10'

TA744

96230

4" Gong

8-16

3-6

1

78 @ 10'

TA725

96226

Buzzer

8-16

3-6

1

88 @ 3'

ORDERING INFO

MOUNTING: Fully enclosed sturdy steel bases.

Junction box & (2) wire nuts (not furnished)

ORDERING INFO CATALOG NO.

UPC CODE

INPUT VOLTAGE

dB @10 FEET

AMPS

VA

TA315-1N5

96599

120VAC/DC

117

2.5

300

APPLICATIONS

Powerful and loud, pleasant sounding push-button chimes. Ideal for homes, apartments and offices.

ALARM: Chime.

HOUSING: Red enamel paint over heavy gauge aluminum housing. Fully enclosed motor. 180° swivel and adjustable direction.

Siren power wires

(2) 9/32" mounting holes

PULL-DOWN STATION

APPLICATIONS

INPUT: 16V, 10VA, 120VAC.

1/2" conduit (not furnished) 6-7/8"

MANUAL FIRE ALARM

CHIMES & CHIME KITS

FEATURES

Power wires 2 feet long

INPUT VOLTAGE: 120AC & DC, 60Hz. ALARM: Loud, distinctive tone. Designed to be effective over standard horns or bells.

8-1/2" dia.

1/2" conduit connector

CATALOG NO.

UPC CODE

TAC212WS

96064

TAC212WL

96054

TAC210W

96052

DESCRIPTION

16VAC Chime + Push Button clip for Stucco + 10VA Transformer 16VAC Chime + 2 Push-buttons + 10VA Transformer 16VAC Chime

DIMENSIONS

73⁄16”L x 4”W x 2”D 71⁄4”L x 43⁄4”W x 21⁄2”D 71⁄4”L x 43⁄4”W x 21⁄2”D

Designed for indoor use. Ideal for schools, hospitals, industrial plants, warehouses and retail stores. Key required to close and reset device. Meets requirements, BSA, MEA, CA and UL. FEATURES ALARM: Loud, distinctive tone. Designed to be compatible with any control panel to initiate local alarm signals, trip municipal fire alarm box and start fire pumps.

ORDERING INFO CATALOG NO.

UPC CODE

SWITCH

VOLTS

AMPS

TA270A

96521

SPST, NO

30V AC/DC

1

MOUNTING: Sturdy metal construction, mounts to a standard single gang electrical box.

TORK ALERT ™ TORK 129

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

TORK 130

TELEPHONE RELAY

TELEPHONE STROBE

APPLICATIONS

APPLICATIONS For single-line analog phone lines. Emits a high intesity flashing light when the telephone rings. Ideal for alerting the hearing impaired, high ambient noise environments and quiet zones. ADA compliant.

This device activates appliances when a telephone ring voltage is detected. For indoor and outdoor use with horns, bells or strobes. Recommended use where ambient noise levels are high. FCC approved.

ORDERING INFO

FEATURES PLUG: RJ-11C connection. TA-B-KHD-120VAC, includes 120VAC power cord.

RINGER PEAK EQUIVALENCE CANDLEPOWER

CATALOG NO.

UPC CODE

INPUT TELEPHONE RING VOLTAGE

POWER

TA-B-KHD-120VAC

97101

45-130V, 20-30Hz

120VAC

0.4

50-130V, 20-30Hz

Analog line ring voltage

1.5

TA-B-KHD-1000-PP

97102

ORDERING INFO

FEATURES

CATALOG NO.

UPC CODE

INPUT TELEPHONE RING VOLTAGE

AC INPUT VOLTAGE

RINGER EQUIVALENCE

PEAK CANDLEPOWER

70,000

INPUT: Accepts RJ-11C phone plug.

TA-B-8332

97100

39-150V/20-30Hz

WIRING: Hard wire connections, for analog phone lines.

Up to  115VDC-500MA

0.6

8,000

115VAC-5A, 230VAC-2A

MOUNTING: Easily mounts to interior surfaces, for indoor use.

MOUNTING: Weatherproof, indoor and outdoor, includes mounting bracket.

TELEPHONE HORN

WALL CLOCKS QUARTZ & ELECTRIC

ORDERING INFO QUARTZ CLOCK

APPLICATIONS

APPLICATIONS High quality compact signaling device. For indoor use. Easily connects to phone systems and enables locations with moderate to high ambient noise to have a loud telephone alert. FCC approved.

Each model meets United States Government Specifications. All Clocks provide second hand for accurate timing. ORDERING INFO

FEATURES ALARM: Adjustable tone and volume.

FEATURES

CATALOG NO.

UPC CODE

INPUT TELEPHONE RING VOLTAGE

dB @3 FEET

RINGER EQUIVALENCE

TA-B-KHS-1000-PP

97103

50-130V, 20-30Hz

90

0.8

PLUG: RJ-11C modular connection. MOUNTING: Grey enclosure. For indoor use, surface mountable.

QUARTZ Accurate to one minute per year. Low power consumption for long battery life. Uses AA battery (not supplied). ELECTRIC 110VAC, 60 Hz synchronous motor. 66 inch line cord and plug. Does not require grounding. MOUNTING: Concealed mounting brackets allow for simple, neat placement on walls.

CATALOG NO.

UPC CODE

TYPE

SIZE

FRAME COLOR

TA1886 G

96156

QUARTZ

8”

Grey

TA1886 B

96155

QUARTZ

8”

Brown

TA1887 G

96159

QUARTZ

12”

Grey

TA1887 B

96157

QUARTZ

12”

Brown

TA1887 BK

96158

QUARTZ

12”

Black

ELECTRIC CLOCK CATALOG NO.

UPC CODE

TYPE

SIZE

FRAME COLOR

TA1880 G

96152

ELECTRIC

8”

Grey

TA1880 B

96151

ELECTRIC

8”

Brown

TA1882 G

96154

ELECTRIC

12”

Grey

TA1882 B

96153

ELECTRIC

12”

Brown

TORK ALERT ™ TORK 131

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

TORK 132

PUSH-BUTTONS ILLUMINATED, NON-ILLUMINATED & WEATHERPROOF

ELECTRIC DOOR OPENERS REMOTE CONTROL & CONTACT DEVICES

DIMENSIONS TA1786B Only 1 3/8" (34mm)

2-3/8" DIA.

1-13/16" BETWEEN CL

2 13/32" (61mm)

MOUNTING HOLES ON MODEL TA1786B and TA1786CB

MODEL TA1786CB

For unlocking or locking metal or wooden doors using low voltage wiring. For AC, use TA591 or TA592 transformer.

MORTISE TYPE REMOTE OPENER

Reversible for right or left hand door. Use with mortise entrance locks having a latch bolt with up to 1⁄2" width and throw. Dimensional drawings available on page 138. DEVICE

CATALOG NO.

UPC CODE

VOLTS

AMPS

For outdoor use to activate low voltage bells, buzzers, horns or any other audible signal. Ideal for factory doors, receiving departments, small office buildings, limited access retail stores and private homes.

BUTTON

For activating a variety of signals, ideal for limiting space applications. Self-insulating and can be mounted in any direction. All units include companion magnet. Dimensions: 23⁄16”L x 1⁄2”W x 1⁄2”D UPC CODE

DESCRIPTION

TA60

96975

Circuit closed with magnet engaged

TA61

96976

Make & break NO and NC

TA62

96977

Circuit open with magnet engaged

VOLTS

24VAC 12VDC

TA09

96960

8-16VAC 3-6VDC

.95-1.75 1.25-1.80

AMPS MAX.

TA154

.5

96962

16VAC 3-6VDC

BUTTON

Signals automatically with the opening and closing of doors, windows and transoms. Operates from pressure in any direction. Non-tilt, non-jamming design. Fits 3⁄4" hole; no need to mortise. DEVICE

CATALOG NO.

UPC CODE

DESCRIPTION

TA44

96995

Normally closed Push to open

TA45

96996

Normally open Push to close

TA46

Momentary contact 96997 Push to make & break

VOLTS

AMPS MAX.

CATALOG NO.

Reversible for right or left hand door. Standard surface type used with lock latches with up to 5⁄8" width and throw. 6" wire leads. Dimensional drawings available on page 138. CATALOG NO.

UPC CODE

TA603L

2

ELECTRIC DOOR SWITCH

TA152

96961

UPC CODE

DESCRIPTION

INPUT VOLTAGE

TA1786B

96090

Without conduit backplate

TA1786CB

96091

With conduit backplate

Momentary Contacts 4 amps AC/DC @ 12V 4 amps AC, 2 amps DC @ 24V 2 amps AC 1 amp DC @48V

NON-ILLUMINATED PUSH-BUTTONS, UP TO 24VAC

COLOR

96035

Gold

CATALOG NO.

UPC CODE

COLOR

SIZE

TA600

96041

Polished Brass

21⁄4” (diameter)

TA603

96044

Polished Brass

13⁄4” (diameter)

TA631

96088

White

23⁄4 x 7⁄8"

TA635

96047

Ivory, black bar

23⁄4 x 7⁄8"

TA666BK

96048

Black, ivory bar

23⁄4 x 23⁄4

TA602

96043

Polished Brass

13⁄8 x 51⁄4 ”

TA601

96042

Sprayed Brass

2 x 29⁄16 ”

5⁄8"

TA620*

96045

Chrome

5⁄8” (diameter)

5⁄8"

TA620B*

96046

Brass

5⁄8” (diameter)

SIZE

13⁄4"

(diameter)

VOLTS

TA631L 12-24V AC/DC

UPC CODE

RIM TYPE REMOTE OPENER

DEVICE

CATALOG NO.

.95-1.75 1.25-1.80

ILLUMINATED PUSH-BUTTONS, UP TO 16VAC

DOOR/WINDOW CONTACTS, ROLLING BALL TYPE

MODEL TA1786B

WEATHERPROOF PUSH-BUTTONS / SOLID CAST BRASS

MAGNETIC SWITCH CONTACTS CATALOG NO.

2 13/32" (61mm)

APPLICATIONS

APPLICATIONS

DEVICE

1 3/16" (30mm)

96089

White

23⁄4 x 7⁄8"

8-16VAC, 3-6VDC

DOOR TRIP SWITCH

TA656B

96039

Gold

TA215LB

96031

Brass

TA620L*

96037

Chrome

TA620LB*

96038

Brass

15⁄16

x 23⁄4”

BUTTON

For turning lights/signals on or off when doors are opened or closed. Ideal for closets, dark rooms, Signals automatically as door is openend. Commonly used on store doors to announce storage areas of walk-in refrigeration. Rust resistant steel case with 4 knockouts, antique brass plate. entrance of customers. Mounts on top of door frame. Solid cast brass. Size: 3 x 15⁄8“ Box dimensions: 11⁄4"W x 3 7⁄8"H x 2”D. Plate dimensions: 11⁄4”W DEVICE

CATALOG NO.

UPC CODE

DESCRIPTION

VOLTS

AMPS MAX.

TA502

96964

Light ON when door is open

125VAC 250VAC

6 3

DEVICE

CATALOG NO.

TA236 TA503

96965

Light OFF when door is open

125VAC 250VAC

6 3

UPC CODE

96963

VOLTS

12-24VAC

AMPS MAX.

2

11⁄4 x 2”

(diameter) (diameter)

*Stainless steel plate to fit TA620 models: Order TA 147-1

TORK ALERT ™ TORK 133

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

TORK 134

WARNING LIGHTS INDUSTRIAL UNITS

WARNING LIGHTS VEHICULAR UNITS

ORDERING INFO

APPLICATIONS

COLOR

LETTER TO REPLACE "*"

Red Amber Clear Blue

R A C B

conduit mounting. Full selection of dome colors, see "Ordering Info". For outdoor use. All units must be mounted vertically with base at bottom.

DESCRIPTION

TA52*N5 – COMPACT ROTATING BEACON DEVICE

117VAC 117VAC

TA53*E1 – ROTATING BEACON

Light intensifying reflector rotates arounf a low current 25 watt bulb. Bayonet socket for easy lamp replacement. Ideal for restricted or dangerous areas.

VOLTS AMPS

90 FPM Corrosion resistant/Outdoor use Glass filled polypropylene housing Acrylic dome TA47AN5 96161 Tamper resistant dome clamps Nominal current draw TA47AR5 96162 91⁄2"H x 81⁄2” diameter

TA47RN5 96061

CATALOG UPC NO. CODE

TA52RN5 96063 .9

TA52AN5 96163

240VAC, 60Hz

TA52BN5 96263

DESCRIPTION

VOLTS AMPS

DEVICE

CATALOG UPC NO. CODE

TA53RE1 96083

80-90 FPM 360˚ rotation Dependable belt & turntable design 117VAC .21 Acrylic dome Nominal current draw 61⁄2”H x 55⁄8” diameter

TA53AE1 96183 TA53AF1 96185

Solid state circuitry in a low profile design. No moving parts means less Maintenance!

TA93-2AN5 97623 TA93-2CN5 96968 TA93-2BN5 97624

Single point shock-mounting. Ideal for use on security or service vehicles.

DESCRIPTION

VOLTS

90-100 FPM Dependable belt & turntable design 25 watt lamp Acrylic Dome Nominal current draw 71⁄2”H x 6” diameter

12VDC

DEVICE

CATALOG UPC NO. CODE

DESCRIPTION

VOLTS

75 FPM, 12 watt lamp 12VDC Quiet belt-drive motor. Teardrop design fits under windshields. Includes glare shield, velcro tape TA54RE1 96087 41⁄2”H x 71⁄2” diameter

TA54AE1 96187

36VDC 24VDC

TA371L*N5 – ROTATING SEALED TWIN BEAMS

TA93-2*N5 – MIDI-STROBE

TA93-2RN5 99622

R A

TA54*E1 – PORTABLE, MAGNETIC, ROTATING BEACON

Single point shock-mounting. Ideal for use on security or service vehicles.

TA53AG1 96184

DEVICE

Red Amber

conduit mounting. Full selection of dome colors, see "Ordering Info". For outdoor use. All units must be mounted vertically with base at bottom.

TA47*N5 / TA47*R5 – ALL PURPOSE 360° BEACON

CATALOG UPC NO. CODE

LETTER TO REPLACE "*"

1⁄2"

Large parabolic reflector rotates around a 100 wall bulb. Long range beam. Use to indicate equipment malfunctions, security intrusion, etc. CATALOG UPC NO. CODE

COLOR

APPLICATIONS

1⁄2"

DEVICE

ORDERING INFO

DESCRIPTION

Heavy Duty, double sealed beam, revolving light with 30 watt lamps. Each 35,000 CP bulb provides long range visibility.

VOLTS AMPS

70-80 FPM Solid state electronic circuitry High output 3-4 watt, 3.6 joules Vertically mounted flash tube 117VAC .04 Snap out socket base for 360˚ Fresnel dome optics Nominal current draw 6 1⁄2”H x 5 1⁄8” diameter

DEVICE

CATALOG UPC NO. CODE

TA371LRN5 96500

DESCRIPTION

TA131D*N5 / TA131D*U1 – DOUBLE FLASH SUPER STROBE

VOLTS AMPS

80-90 FPM 117 VAC Lexan® dome Quiet belt drive motor Anodized aluminum housing with polished aluminum, non-tarnishing base Snap lock retaining ring for quick & economical changeout 91⁄2”H x 8 1⁄2” diameter

.8

Ideal for industrial applications requiring extremely high visibility. One model covers all popular mounting methods: 1⁄2" pipe, surface, flange, electrical box. DEVICE

CATALOG UPC NO. CODE

TA131DRN5 96510 TA131DAN5 96610 TA131DRU1 96511 TA131DAU1 97611

TA94*N5 – ELECTRONIC STROBE

DESCRIPTION

VOLTS AMPS

120VAC 60 FPM, 7.5 JPF High intensity 85,000 peak CP Flashtube Rated at 7000-8000 hrs. Durable Lexan® housing 10.55”H x 71⁄4” diameter

.2

TA879 – VEHICULAR BACKUP ALARM

Solid state electronic unit. Helps to comply with OSHA and State regulations. Makes distinctive noise, ideal for extreme variations in background noise DEVICE

CATALOG UPC NO. CODE

TA879

96102

DESCRIPTION

VOLTS

2 sound levels 97 or 87 dB +/- dB at 4ft Multi-voltage Water-resistant housing

12 to 48VDC

31.0VDC

High intensity strobe tube with inner fluted lens for maximum brilliance. No moving parts makes it immune to shock and vibration. Ideal for security alert. DEVICE

CATALOG UPC NO. CODE

DESCRIPTION

VOLTS AMPS

70-80 FPM Solid state electronic circuitry High output 3-4 watt, 3.6 joules Acrylic dome TA94AN5 97627 117VAC .04 Glass filled polypropylene housing Suitable for outdoor use TA94BN5 97628 91⁄2”H x 81⁄2” diameter TA94RN5 97626

NOTE: "FPM" = Flashes per minute "JPF" = Joules per flash For replacement parts and accessories, see page 138.

TORK ALERT ™ TORK 135

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

TORK 136

ACCESSORIES, REPLACEMENT PARTS & DIMENSIONS

POWER SUPPLY UNITS 24 VDC UNITS

TA640 TA606

Red Amber Clear Blue Green White

Units provide power to multiple signaling devices depending on requirements.

TA606 Regulated and filtered 24VDC up to 600mA. Easy to use screw terminals, accepts #16-24AWG. No conduit is required for installation.

RIPPLE OUTPUT CURRENT REGULATION VOLTAGE

CATALOG NO.

UPC CODE

INPUT VOLTAGE

OUTPUT VOLTAGE

TA606

96109

117VAC

24VDC

600mA

TA640

96110

115VAC

24VDC

4A

+/-5%

10mVRMS

TA640 Dual output unit, each providing 2 Amps fo current. If connected in parallel, will provide up to 4Amps. Circuit breaker provides input protection.

TRANSFORMERS

UNIT

ORDERING INFO UPC CODE

TYPE

TA590

96104

Bell

TA591

96105

Chime

VOLTS-AMPS PRIMARY SECONDARY (VA) VOLTAGE VOLTAGE

5 10

120 120

10 16

Hz

60 60

TA592

96106

Tri-Volt

10-10-20

120

8-16-24

50/60

TA598

96602

Tri-Volt

20-30-30

120

8-16-24

60

TA599 TA1245Y-50 TA1245Y-75

96108 96166 96167

Heavy Duty Heavy Duty Heavy Duty

96971

Acrylic Dome – Amber

TA-M1

96138

12VDC Motor

TA53, TA54

TA-B1

96114

Small Drive Belts

TA53, TA54

TA-B2

96115

Large Drive Belts

TA371L

TA-B3

96116

Drive Belts

TA53, TA54

TA-L3

96129

12VDC Bulb

TA53

TA-L4

96130

24VDC Bulb

TA93-2

TA-L6-2

96982

110VAC Xenon Flash Tube

TA52

TA-L8

96134

110VAC Bulb

TA47

TA-L9

96135

110VAC Bulb

TA-L10

96136

110VAC Xenon Flash Tube

TA-L10-1 96981

110VAC Xenon Flash Tube

40 50VA 75VA

120 120/208/240 120/208/240

24 24 24

60 60 60

TA-L12

97625

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

WIRING DIAGRAMS

1/2"

2-7/8"

1-13/16"

TA874 Series

TA-BBSF 97694

TA874 Series

TA-WBBF 97692

Backbox – 4" painted Dawn Mist Weatherproof Backbox – .5" KOs 4" painted Dawn Mist Semi-Flush plate – Dawn Mist

3"

3-1/2"

TA-ADR

96111

Acrylic Dome – Red

TA47, TA94

TA-ADA

96311

Acrylic Dome – Amber

TA47, TA94

TA-ADB

96411

Acrylic Dome – Blue

TA52, TA53

TA-D5B

96419

Acrylic Dome – Blue

WIRE LEADS 11/16"

3/32" 1-3/8"

TA-D6A

96320

Dome – Amber

TA54

TA-D6C

96422

Dome – Clear

TA93, TA94

TA-D7R

96121

Fresnal Dome – Red

TA93, TA94

TA-D7A

96321

Fresnal Dome – Amber

TA-D7B

96421

Fresnal Dome – Blue

TA131D

TA-D8R

96970

4-1/16"

15/16" 3/16" 7/16"

HEAVY DUTY BELLS 6” 10" DIA.

10”

6" 4-1/16" 3-3/8"

3-3/8"

10" DIA.

4-1/16"

3-3/8" 3-3/8" 4-1/16"

3-3/8"

3-1/4" .173 DIA. CSK 80 ° TO 82° TO 11/32" DIA. – 4 PLACES

3-3/8" 4-1/16"

3-3/8"

.173 DIA. CSK 80 ° TO 82° TO 11/32" DIA. – 4 PLACES

4 1/16” 3-3/8"

3-3/8"

3-1/4"

4-1/16"

.173 DIA. CSK 80 ° TO 82° TO 11/32" DIA. – 4 PLACES

.173 DIA. CSK 80 ° TO 82° 6" 11/32" DIA. – 4 PLACES TO

4-1/16" 3-3/8"

Acrylic Dome – Red

.173 DIA. CSK 80 ° TO 82° TO 11/32" DIA. – 4 PLACES 3-1/4"

3-3/8"4-1/16"

3-1/4"

3-1/4"

3-1/4"

.173 DIA. CSK 80 ° TO 82° TO 11/32" DIA. – 4 PLACES

4” 3-3/8"

10" DIA.

6"

4-1/16"

4-1/16" 3-3/8"

4-1/16"

Fresnal Dome – Clear

TA93, TA94

5/8"

27/32" 23/32"

Dome – Red

TA54

CL

1-9/16"

No. 6 FLAT HEAD WOOD SCREW

Semi-Flush plate – Red

TA47, TA94

3/32"

7/16"

CL

TA154

1/4" 15/16"

7/32"

1/8"

5/8" 1-1/4"

Replacement switcH

96621

1-1/4"

110VAC Bulb

4-1/16"

TORK 137

NO. 8 FLAT HEAD WOOD SCREW

TA503SW 96969

TA-D7C

1"

CL

TA503

TA93, TA94

5/8" 1-3/4"

5-7/8"

Replacement switch

96120

1-9/16"

3-5/8"

TA502SW 96966

TA-D6R

3/4"

5-3/8"

TA502

TA54

3/8"

1-3/8"

Backbox

TA-BBSF, TA-WBBF TA-SFPFR 97697

11/32"

2-3/4"

3/32"

TA502-BX 96967

97707

1/8"

1/16"

TA09

TA502

TA-BBSF, TA-WBBF TA-SFPF

1/16"

9/16"

DESCRIPTION

3-3/8"

TORK ALERT ™

11/16"

No. 6 MOUNTING SCREWS (3)

1/2"

CL

TA-D8A

TA94

APPLICATIONS

CATALOG UPC NO. CODE

WIRE LEADS

CL 1-3/8"

2-1/8"

< Full selection of dome colors. To designate color, place desired letter in place of " * "

TA53

TA-94

CATALOG NO.

3-5/16"

1-3/16"

TA131D

TA371L

Engineered to ensure long use on bells, buzzers and chimes.

9/16"

TA152

ORDERING INFO

ORDERING INFO FEATURES

REMOTE CONTROL DOOR OPENERS

15/16"

APPLICATIONS

LETTER TO REPLACE "*" R A C B G W

COLOR

DIMENSIONS

4-1/16"

2-7/8"

.173 DIA. CSK 80 ° TO 82° TO 11/32" DIA. – 4 PLACES

TORK 138

POOL&SPA CONTROLS

PP PANEL SERIES POOL AND SPA PANELS WITH TIME SWTICHES

APPLICATIONS Pumps Swimming pools Fountains Ponds

LISTED POOL/SPA CONTROL PANEL 3NZM

PP-100R-P4

ORDERING INFO

PP-20R-2P4

CONTROL INPUT

CONTROL #2

120VAC

N/A

Rated for 15A, 1⁄2HP @ 120VAC

53011

Mechanical 24 hour timer Digital 7 day timer

120VAC

N/A

Rated for 15A, 1⁄2HP @ 120VAC

PP-20R

94015

N/A

120/240VAC

N/A

Panel only. Add controls from page 147 and 148.

PP-20R-P1

53000

P1101-M

120VAC

N/A

PP-20R-P4

53001

P1104-M

240VAC

N/A

DEVICE MOUNTING: Provision for mounting one or two devices in any combination accepts toggle, GFCI, X-10 and UPB type devices in, PP-100R and PP-125R enclosures.

PP-20R-2P1

53002

P1101-2M

120VAC

PP-20R-2P4

53003

P1104-2M

240 VAC

Included with control #1 mechanism Included with control #1 mechanism

PP-100R

94016

N/A

120/240VAC

TRANSFORMER: Select panels include 120V input: 100 watt with output 12V/13V or 300 watt with output 12V/13V/14V.

PP-100R-P4

53004

P1104-M

240VAC

PP-100R-P4P1

53005

P1104-M

240VAC

P1101-M

120VAC

PP-100R-2P4

53006

P1104-M

240VAC

P1104-M

240VAC

PP-100R-P4P4FM

53009

P1104-M

240VAC

P1104FM-M

240VAC

PP-125R

94017

N/A

120/240VAC

PP-125R-P4

53007

P1104-M

240VAC

PP-125-2P4

53008

P1104-M

240VAC

P1104-M

240VAC

PP-125R-P4-100X

94018

P1104-M

240VAC

PP-125R-P4-300X

94019

P1104-M

240VAC

PP-10R-M-GFCI

FEATURES COMBINATION PANEL: The PP panel series provides a flexible platform to create a custom pool and spa control at an off the shelf price. Start with a blank panel and addtimers, freeze controls, circuit breakers, switches and outlets for a custom installation. Or select a pre-assembled timer/panel available in many popular combinations. PP-10R: 15 amp timed GFCI protected outlet with additional GFCI outlet. PP-20R: 20 amp load center 120-240V, 1/2 circuit breaker base. PP-100R: 100 amp load center 120-240V, 5/10 circuit breaker base. PP-125R: 125 amp load center 120-240V, 8/16 circuit breaker base. CONTROLS: Freeze protection or mechanical and digital timers are all available with unique features not found elsewhere in the industry. Find specification details on pages 147 and 148. BREAKERS: Listed for Cutler Hammer (BR), GE (THQL), Murray/Siemens (MP) and Square D (HOM) (not included).

REVERSIBLE DOOR: Easy-Hinge patented removable and reversible door. Change from left to right opening. Solves installation issues in the field. WHILE-IN-USE COMPARTMENT: Inside mounting for two devices with cord exit.

COMPACT 2-IN-1: PP-20R-2P1 and PP-20R-2P4 includes two timers in a compact housing. Interlock switch allows second timer to turn ON only if first timer is in operation. ENCLOSURE: Metal NEMA 3R with lockable hasp. See page 153 for dimensions.

NOTE: " " = Indicates freeze protection.

POOL & SPA CONTROLS TORK 141

PP-125R-P4-100X

PP-125R-P4

PP-20R-P4

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

CATALOG NO.

UPC CODE

PP-10R-M-GFCI

53010

PP-10R-E-GFCI

CONTROL #1

CONTROL INPUT

ADDITIONAL INFORMATION

120VAC

Two timers design 50A panel

240VAC

Two timers design 60A panel Panel only. Add controls from page 147 and 148. Add another control from page 147 and 148.

Timer 2 includes Fireman Switch Panel only. Add controls from page 147 and 148. Add another control from page 147 and 148.

Includes 100 watt Low Voltage Transformer Includes 300 watt Low Voltage Transformer

TORK 142

PFP SERIES

1100 SERIES

POOL FREEZE PROTECTION SWIMMING POOL TIME SWITCHES

SPECIFICATIONS

SAME ON/OFF TIMES EACH DAY SWIMMING POOL TIME SWITCHES

INPUT VOLTAGE: 120 or 208-277VAC, 60Hz (varies by model). TIMING ACCURACY: Line frequency. TERMINAL RANGE: #8 - #14AWG. OPERATING TEMPERATURE: -40° to 165°F (-40° to +74°C).

APPLICATIONS

APPLICATIONS

POWER CONSUMPTION: 3 watt max.

Pool pumps Heaters Lighting

Pumps Swimming pools Fountains Ponds

ENCLOSURE: Lockable hasp. Type varies by model. See page 153 for dimensions and additional enclosure information.

FEATURES SCHEDULING: Minimum ON setting is 20 minutes with a minimum OFF setting of 75 minutes. Dial accommodates up to 12 pairs of trippers. One pair included. MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF automatic operation then resumes.

FEATURES FREEZE PROTECTION ONLY: Sensor turns on load when outdoor air temperature drops to user settable level between 33°F to 42°F. Moving water prevents costly freeze damage. TIMERS WITH FREEZE PROTECTION: Control loads with mechanical or digital timer with regular on and off schedule. Built-in temperature sensor forces load on if outdoor air temperature drops to user settable level between 33°F to 42°F. COMBINATION PANEL Combination of timers, freeze protection, breaker base, and device mountings. PP-20R: 20 amp load center 120-240V, 1⁄2 circuit breaker base. PP-100R: 100 amp load center 120-240V, 5⁄10 circuit breaker base.

ORDERING INFO CATALOG NO.

UPC CODE

CONTROL

CONTROL INPUT

NOTES

CATALOG NO.

UPC CODE

PFP2

94035

PFP2-M

240VAC

Freeze protection only

1101

10011

PFP3

94036

PFP3-M

120/240 w/neutral

Freeze protection only

1101-M-IAP

10052

PFP1102

94037

PFP1102-M

240VAC

1104

10014

PFP1103

94038

PFP1103-M

120/240 w/neutral

1104-N

10042

PFPEW1102

94039

PFPEW1102-M

240VAC

1104-O

10017

PFPEW1103

94040

PFPEW1103-M

120/240 w/neutral

1104-M-IAP

10051

PP-20R-F2

94033

PFP1102-M

240VAC

1101FM-N

10043

94034

PFP1102-M & P1104FM-M

240VAC

Freeze protection with timer Freeze protection with timer Freeze protection with Digital timer Freeze protection with Digital timer Freeze protection with timer Timer 2 includes Fireman Switch

1104FM-N

10044

120/240VAC

Thermostat accessory

1101FM-M

10043

1104FM-M

10044

1101D

10028

1104D

10029

1104DF

10032

PP-100R-F2F4FM PFPT

94028

BEAKERS: Listed for Cutler Hammer (BR), GE (THQL), Murray/Siemens (MP) and Square D (HOM) (not included). WHILE-IN-USE COMPARTMENT: Inside mounting for two devices with cord exit.

Replacement Trippers

DEVICE MOUNTING: Provision for mounting one or two devices in any combination accepts toggle, GFCI, X-10 and UPB type devices.

POOL & SPA CONTROLS TORK 143

NOTE: "

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

CONTACT RATINGS

ORDERING INFO

" = Indicates Freeze Protection.

Replacement Motor

INPUT SUPPLY (VAC) 60Hz

OUTPUT CONTACTS

ENCLOSURE TYPE

Metal Indoor NEMA 1 Mechanism and 120 SPST mounting plate Metal Indoor 208-277 DPST NEMA 1 ® Indoor/Outdoor Noryl 208-277 DPST NEMA 3R Metal Indoor/Outdoor 208-277 DPST NEMA 3 Mechanism and 240 DPST mounting plate Noryl® Indoor/Outdoor NEMA 120 SPST 3R with fireman switch ® Indoor/Outdoor NEMA Noryl 208-277 DPST 3R with fireman switch Mechanism with fireman 120 SPST switch Mechanism with fireman 208-277 DPST switch Two 1101 Metal Indoor/Outdoor 120 SPST each NEMA 3R Two 1104 Metal Indoor/Outdoor 208-277 DPST each NEMA 3R One 1104 Metal Indoor/Outdoor NEMA 208-277 One 1104FM 3R Order #P47 for a pair of ON/OFF trippers Order #PF48 for a pair of ON/OFF trippers for 1100FM series 120

SPST

TYPE

VOLTAGE

CONTACT RATING

40A

Resistive

120-277VAC single phase 120-277VAC single phase

Tungsten

120VAC

40A

Inductive

120, 277VAC single phase

20A

Pilot Duty

120-277VAC

1000VA

Motor

120VAC 240VAC

2HP 5HP

General Purpose

40A

#101 (120V) & #201 (208-277V)

TORK 144

DW200B TIMER

CONTACT RATINGS

SPECIFICATIONS

TWO SPEED PUMP CONTROL TIME SWITCH

TYPE

TIMING ACCURACY: Line Frequency. INPUT VOLTAGE: 120/208-240/277VAC, 50/60Hz.

Two speed pumps SVRS device

30A

30A

Ballast

OPERATING TEMPERATURE: -40°F to 158°F (-40°C to +70°C).

120VAC 277VAC

30A 20A

10A 10A

Tungsten

120-277VAC

15A

2A

POWER CONSUMPTION: 5VA max.

Pilot Duty

120-277VAC

720VA

720VA

ENCLOSURE: Noryl® Indoor/Outdoor NEMA 3R is standard with lockable hasp. See page 153 for enclosure dimensions and accessories.

Motor Load

120VAC 208-277VAC

1HP 2HP

1HP 2HP

Resistive

28VDC

30A

30A

CH 1 SPDT

SPDT

DWZ100B SERIES

TWO CHANNEL: Two programmable contacts for independent control of pool equipment and SVR or coordinated control for two speed pumps. SCHEDULING: 99 ON & OFF set points allow individual programs for each day of the week at a minimum 1 minute apart.

ORDERING INFO CATALOG NO.

DW200B DW200B-0

UPC CODE

82190 82231

TIMER SUPPLY (VAC) 60Hz

120/208-240/277VAC 120/208-240/277VAC

SPDT C

TIMER SUPPLY

NO. OF CHANNELS

2 2

DRY CONTACTS (UNPOWERED)

DWZ100B SERIES TIMER SUPPLY

N

SPDT SPDT

120

208-240 277

120V N

120

208-240 277

208-240V

120V

C

NO NC

TIMER SUPPLY

N

L N

L

277V

AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE

TIMER SUPPLY

LOAD N

CH 1 SPDT

DW200B SERIES

NO NC

AC LINE INPUT SELECT277V PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE

DAYLIGHT SAVING: Automatic adjustment (can be omitted) for year-round pools.

DW200B SERIES

LOAD

208-240V

HOLIDAYS: 1 to 24 individual dates for preprogrammed longer run times for heavy use times.

NC

24-277VAC

WIRING DIAGRAMS

FEATURES

NO

General Purpose

TERMINAL RANGE: #12 - #16AWG.

APPLICATIONS

CONTACT RATING

VOLTAGE

120

120V N

120

C

208-240 277

208-240 277

CH 2 SPDT

C

NO NC

NO NC

C

277V L

208-240V

LOAD AC LINE INPUT N SELECT PROPER TERMINALS 277V AND APPLY ONLY ONE VOLTAGE

C

NO NC

NO NC

L

208-240V

120V

CH 2 SPDT

L LOAD L N

LOAD N

LOAD N

AC LINE INPUT SELECT PROPER TERMINALS AND APPLY ONLY ONE VOLTAGE

TWO SPEED PUMP WIRING

MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes.

TWO SPEED PUMP WIRING

CLOCK FORMAT: AM/PM or Military time POWER OUTAGE BACKUP: Permanent schedule retention when timer is powered down at the end of the season. Super capacitor provides 7 days of real time backup.

POOL & SPA CONTROLS TORK 145

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

TORK 146

P1100 SERIES

QUICK INSTALL/RELEASE LEVER: For easy installation and removal when installing into pool panels.

SWIMMING POOL TIMERS, 24 HOUR ELECTROMECHANICAL CONTROL

LOAD INDICATOR LAMP

P1100 SERIES

QUICK INSTALL/RELEASE LEVER: For easy installation and removal when installing into pool panels.

SWIMMING POOL TIMERS, 7 DAY DIGITAL CONTROL

LOAD INDICATOR LAMP LARGE LCD DISPLAY

CONVENIENT EXTERNAL ROCKER SWITCH: 3 position switch: OFF/ON/AUTO. Use switch to turn OFF pump at the end of pool season.

LARGE "MANUAL" BUTTON: 3 operating modes available: OFF/ON/AUTO. Using the OFF mode, the pool can be closed down without disrupting the time settings.

REAL TIME SWITCH FACE: Easy to set and check time.

POWER OUTAGE BACKUP: Battery retains time and schedule.

CAPTIVE TRIPPERS: 15 minute intervals, no lost trippers. HEATER CONTACTS: FM suffix includes "Fireman Switch" to turn off pool heater 20-30 minutes before timer turns OFF. Contact rates SPST, 15A @120V.

7 DAY PROGRAMMING ONE MINUTE INTERVAL: Allows for the control of various electrical equipment on a 7 day schedule. 15 schedule weekly programs.

THERMOSTAT: PFP models include built in Freeze Protection. No extra wiring. Thermostat turns on load at user settable level between 33°F and 42°F. Moving water prevents costly freeze damage. ACCESSORY CONTACT: PF models include extra contact to accept PFPT Freeze Protection Accessory. Thermostat turns ON load at user settable level between 33°F adn 42°F. Moving water prevents costly freeze damage. TIMER INTERLOCK: Makes one second timer dependant on operation of another timer.

ORDERING INFO CATALOG NO.

RESISTIVE/ UPC INPUT SUPPLY CODE (VAC) 60Hz CONTACTS INDUCTIVE RATINGS

HP RATING

PFP2-M

94026

240

DPST

40A

7.5HP @ 240V

PFP3-M

94027

120/240 w/neutral

DPST

40A

3 HP @ 120V 7.5HP @ 240V

P1101-M

10056

120

DPST

40A

3 HP @ 120V

P1101FM-M

10060

120

DPST

40A

3 HP @ 120V

PF1101-M

94020

120

DPST

40A

3 HP @ 120V

PF1101FM-M

94024

120

DPST

40A

3 HP @ 120V

PFP1102-M

94022

240

DPST

40A

7.5HP @ 240V

PFP1103-M

94023

120/240 w/neutral

DPST

40A

3 HP @ 120V 7.5HP @ 240V

P1104-M

10057

240

DPST

40A

7.5HP @ 240V

P1104FM-M

10061

240

DPST

40A

7.5HP @ 240V

PF1104-M

94021

240

DPST

40A

7.5HP @ 240V

PF1104FM-M

94025

240

DPST

40A

7.5HP @ 240V

P1101-2M

10058

120

DPST

40A

2HP @ 120V

P1104-2M

10059

240

DPST

40A

5HP @ 240V

POOL & SPA CONTROLS TORK 147

NOTES

Thermostat only Thermostat only

Fireman Switch Accepts PFPT thermostat input Fireman Switch & Accepts PFPT thermostat input Freeze Protection included Freeze Protection included

Fireman Switch Accepts PFPT thermostat input Fireman Switch & Accepts PFPT thermostat input Replacement for PP-20R-2P1 Replacement for PP-20R-2P4

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

THERMOSTAT: PFPEW models include built in Freeze Protection. No extra wiring. Thermostat turns on load at user settable level between 33°F and 42°F. Moving water prevents costly freeze damage. ACCESSORY CONTACT: PFEW models include extra contact to accept PFPT Freeze Protection Accessory. Thermostat turns ON load at user settable level between 33°F and 42°F. Moving water prevents costly freeze damage.

ORDERING INFO CATALOG NO.

RESISTIVE/ UPC INPUT SUPPLY CODE (VAC) 60Hz CONTACTS INDUCTIVE RATINGS

HP RATING

PEW101-M

82432

120

DPST

40A

3 HP @ 120

PFEW101-M

94029

120

DPST

40A

PFPEW1102-M

94031

240

DPST

40A

PFPEW1103-M

94032

120/240 w/neutral

DPST

40A

Accepts PFPT thermostat input protection 7.5HP @ 240V Freeze included 3 HP @ 120V Freeze protection 7.5HP @ 240V included

PEW104-M

82442

240

DPST

40A

7.5HP @ 240V

PFEW104-M

94030

240

DPST

40A

Accepts PFPT 7.5HP @ 240V thermostat input

NOTES

TIMER INTERLOCK: Makes one timer dependant on operation of another timer.

3 HP @ 120

NOTE: "

" = Indicates Freeze Protection.

WIRING DIAGRAMS

POOL & SPA JUNCTION BOXES

A

B

C

APPLICATIONS For installation of underwater pool lights or low voltage connections. Solid brass with grounded post and 3 ground terminals for use with metallic or PVC conduit. NOTE: "

" = Indicates Freeze Protection.

ORDERING INFO CATALOG NO.

UPC CODE

NPF CONDUIT HUB PIPE INPUT A/B/C SIZE

PB-50

94041

1⁄2"

/ 1⁄2" / 1⁄2"

1⁄2"

PB-75

94042

3⁄4"

/ 3⁄4" / 3⁄4"

.3⁄4"

PB-100

94043

3⁄4"

/ 1"/ 3⁄4"

3⁄4"

& 1"

TORK 148

SR-500 & SR-500PS

NEW!

SAFETY VACUUM RELEASE SYSTEMS

2 1 Of all the protections you can put between your family and the risk of entrapment, the best protection is

APPLICATIONS

AT THE SOURCE.

®

A Safety Vacuum Release System (SVRS) works by monitoring the vacuum on the suction side of the pool or spa pump. When a blockage occurs in the main drain or skimmer, a sudden rise in vacuum will cause the SR-500 and SR-500PS to shut down and activate an audible alarm. The pump will remain off with the alarm sounding until manually reset.

Make Your Pool & Spa Safer, Update your

LAYERS OF PROTECTION Door alarms on doors leading to the pool or spa area help to alert parents or staff to anyone entering the pool from the house or building.

Commercial & Residential Swimming pools and spas Fountains Ponds Any pump size

WARNING ALARM: Multiple audible alarm capabilities – allows for quicker alert to harmful situations. AUXILARY CONTACTS: Accessible extra dry contact – auxiliary equipment can be added. EQUIPMENT PROTECTION: Low vacuum sensing - (prevents cavitations or running the pump dry, eliminating costly equipment failure). SCHEDULING: Programmable 24 hour timer, or as stand-alone SVRS working in conjunction with existing pool controller.

POOL & SPA CONTROLS TORK 149

Remote alarms linked to the Safety Vacuum Release System (SVRS) alert parents or attendants when the SVRS is activated, indicating that someone in the pool may need help.

ORDERING INFO

FEATURES PROTECTION: • Provides an important layer of protection, reducing entrapment risk. • Turns off pump in milliseconds upon detecting sudden vacuum change. • Vacuum monitored 128 times per second, rapid response and accurate readings. • Power monitored 50/60 times per second, insures continuous power detection. • Newest state-of-art NEC microprocessor technology-- guaranteed reliability and performance.

OUTSIDE THE POOL AREA Keep children from accessing the pool or spa when unattended

DOOR ALARMS

1

POWER OUTAGE BACKUP: Insures settings and reading will be saved, 30 minute rapid recharge.

INPUT SUPPLY DRY CONTACTS (VAC) 60Hz (UNPOWERED)

CATALOG NO.

UPC CODE

SR-500

95425

120/240

DPST

SR-500PS

95426

120/240

DPST

MAINTENANCE OVERRIDE: 30 minute maintenance override - (for pool or spa service). BUILT-IN DIAGNOSTICS: Displays error codes, prevents guessing during troubleshooting. EASY RETROFIT: Integrates with common existing timer box Trouble free installation, no pipes to cut or glue. COMPLIANCE: ASME/ANSI 112.19.17 as required by the International Building Codes (IBC) and the International residential Codes (IRC). Meets all current codes and standards for SVRSs on new and existing pools and spas. ENCLOSURE: Plastic Indoor/Outdoor NEMA 3R with lockable hasp. See page 153 for dimensions and additional information.

2

Restrict access to a pool or spa by surrounding the area with fencing that is equipt with a self-closing, self-latching gate closure. Utilize gate latches that are adjustable, magnetically operated as well as key lockable.

CONTACT RATINGS TYPE

General Purpose Motor

VOLTAGE

120VAC 240VAC 120VAC 240VAC

FENCE & GATE

3

An emergency STOP button allows parents or attendants in the area to immediately and easily shut down the pump system in the event of entrapment.

INSIDE THE POOL AREA Minimize the risk of entrapment injuries or drowning

CONTACT RATING

20A 3HP

EMERGENCY STOP

4

SVRS

The SVRS automatically shuts down the vacuum pump when sensing a rise in vacuum pressure – in some cases, reacting to potential entrapment conditions in LESS THAN ONE SECOND! Audible alarms linked to the SVRS alert those nearby to a potential entrapment. SVRS should meet or exceed ASME/ANSI A112.19.17 standards in order to comply with IRC and IBC codes.

5

3

DRAIN COVERS

Minimize potential entrapments or “Differential Hold Down Forces,” thereby minimizing the potential for a swimmer to be entrapped.

4

5

Anti-entrapment drain covers should meet or exceed ASME and ANSI A112.19.8 2007 and 2007 Federal Pool & Spa Safety Act and have a Certified Safe Flow Rating. Many compliant drain covers are easily retrofitted to existing drains.

ALL ITEMS AVAILABLE FROM NSi/TORK!

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

More details available in our Safety Products catalog and Layers of Protection brochure, ask your sales representative for more information.

ANTI-ENTRAPMENT DRAIN COVERS

SELF-LATCHING GATE CLOSURES & SELF-CLOSING GATE HINGES

NEW!

NEW!

640-475XV TCA1-MK2 DS360M

TCHD1ARP-MK2 AV20X20 & AV26X26

FEATURES DS360M DRAINSAFE • Designed for use with suction outlet sumps up to 8" in size, will retrofit smaller 5” sumps using additional knockouts. • Certified Safe flow of 123 GPM. • ASME/ANSI A112.19.8 2007 Standard Compliant. DS12X12P DRAINSAFE • Designed to retrofit Pentair style frames, and functions on dual drain as well as single suction outlets. • Certified Safe flow of 250 GPM @ 1.5 FPS. • ASME/ANSI A112.19.8 2007 Standard Compliant. DS12X12H DRAINSAFE • Designed to retrofit Hayward style frames, and functions on dual drain as well as single suction outlets. • Certified Safe flow of 250 GPM @ 1.5 FPS. • ASME/ANSI A112.19.8 2007 Standard Compliant.

FEATURES

DS12X12P

DS12X12H

ORDERING INFO CATALOG NO.

UPC CODE

DESCRIPTION

SURFACE AREA (SQ.IN)

RETROFIT FRAME

DS360M

95431

Drainsafe Anti-Entrapment Type Suction Outlet Cover

27

N/A

DS12X12P

95429

53

Pentair

DS12X12H

95430

53

Hayward

640-475XV

95432

159.6

18 x 18

AV20X20

95433

AV26X26

95434

Drainsafe 12 x 12" Anti-Entrapment Type Suction Outlet Cover Drainsafe 12 x 12" Anti-Entrapment Type Suction Outlet Cover Waterway 18 x 18" Anti-Entrapment Drain Cover Eureka 20 x 20" Anti-Entrapment Drain Cover Eureka 26 x 26" Anti-Entrapment Drain Cover

640-475XV WATERWAY • Designed for single and multiple drain use, the 640-475XV works on dual drain as well as single suction outlets. • Minimizes “Differential Hold Down Forces” of dual drain systems. • Certified Safe flow rate of 540 GPM @ 1.09 FPS.

73.6 108.9

12 x 12 (9 x 9 minimum) 18 x 18 (12 x 12 minimum)

MAGNA•LATCH GATE CLOSURES MagnaLatch quality latches are self-latching with permanent magnets which never lose power, for safer, child-resistant security for your swimming pool gate. The Top Pull model can be mounted so the release knob reaches the minimum code height, typically 54", on a shorter gate. It's adjustable for when the gate gets out of alignment. The Vertical Pull model is designed for gates and fences that are 60” or more in height. TRU•CLOSE GATE HINGES TruClose® hinges are designed so the residential homeowner can quickly and easily adjust tension to support a 375lbs gate load and self-closes up to a 55lb gate, for the ultimate safety around pools and other areas requiring self-closing gates. Hinges are rust-free and are self-lubricating. Regular duty and heavy duty models available.

FENCE MATERIAL

PACKAGING AVAILABLE

CATALOG NO.

UPC CODE

DESCRIPTION

MLTPS2BGA

95439

MagnaLatch Top Pull Gate Latch

MLTPRP

95445

MLVPS2BGA

95440

MLVPRP

95444

MLS2RPAKA

95446

Round Post Adapter Kit

Wholesale

MLSPACER

95447

MagnaLatch Gap Spacer

Retail

Wholesale

MagnaLatch Top Pull Gate Latch, 2" Gap

Retail

Spacer included

Wholesale

MagnaLatch Vertical Pull Gate Latch MagnaLatch Vertical Pull Gate Latch, 2"

Retail

Gap Spacer included

REGULAR DUTY MODELS TCA1RP-MK2

98018

TruClose® Regular Range Gate Hinge

Metal

Retail

TCA1-MK2

98026

TruClose® Regular Range Gate Hinge

Metal

Wholesale

TCA3RP-MK2

98019

TruClose® Regular Range Gate Hinge

Vinyl, Wood

Retail

TCA3-MK2

98027

TruClose® Regular Range Gate Hinge

Vinyl, Wood

Wholesale

TCAMA2RND

98024

TruClose® Regular Range Gate Hinge, Round frames adjustable gap

Wholesale

HEAVY DUTY MODELS

DS-MR

DS-AA

TORK 151

MLTPS2BGA

POOL & SPA SAFETY ACCESSORIES

AV20X20 & AV26X26 EUREKA • Eureka drain covers unique grating system is designed for new construction and retrofit, to add protection from entrapment. • ASME/ANSI A112.19.8 2007 Standard Compliant. • Certified Safe flow rate of 223 GPM (20x20), 495 GPM (26x26).

POOL & SPA CONTROLS

ORDERING INFO

TCHD1ARP-MK2

98020

TruClose® Heavy Duty

Metal

Retail

TCHD1AL2-MK2

98021

TruClose® Heavy Duty, with 2 legs

Metal

Wholesale

TCHD2RP-MK2

98022

TruClose® Heavy Duty

Vinyl, Wood

Retail

TCHD2L2-MK2

98023

TruClose® Heavy Duty, with 2 legs

Vinyl, Wood

Wholesale

SAFETY ACCESSORIES

SR-RA

SR-ESB

SR-RA

95437

Remote Alarm

SR-ESB

95438

Emergency Stop Button

DS-AA

95435

Drainsafe Masonry Anchor Kit - for DS360M

DS-MR

95436

Drainsafe Mud Rings, Universal Fit

ALL ITEMS AVAILABLE FROM NSi/TORK!

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

More details available in our Safety Products catalog and Layers of Protection brochure, ask your sales representative for more information.

TORK 152

ENCLOSURES

ENCLOSURES STANDARD FOR MODELS

METAL INDOOR NEMA 1 ENCLOSURE #68229

STANDARD FOR MODELS

METAL INDOOR/OUTDOOR NEMA 3 MODEL #9006

STANDARD FOR MODELS

METAL INDOOR NEMA 1 ENCLOSURE #63016-1

MECHANISM & MOUNTING BRACKET #62153-1

MODELS

1101

7120

TZ220L-0

TZ300L-0

TZ220L

TW220L

Use Bracket #64039

1102

7122

TZ300L-0

T920L-0

TZ300L

TW300L

W100

W120 W220

3-5/8 "

W222

3-1/16"

1103

8001

W300

T920L

W200

1104

8004

W302

T930L

W202

1101FM

8061

W300L

TW222L

1104FM

8121

W302L

TW302L

7100

8301

#62158 "E" DOOR

7102

8601

T920L-E

7200

8602

TW220L-E

T930L-0

7202

TU40-Y

1101-7

EW201-Y

TRP400

7220

1847AZL LDS-A

7222

8007

7200L

8007L

7202L

8007V

7120L

8150

1847A

8150U

1848A

8007U

1849A

8007VL

1847AZ

8008

1847AL

8008L

STANDARD FOR MODELS

2-1/2"

ELC72PC/120 ELC72PC/208-240

11-1/2"

12"

W302

DLC400BP

LDSH-A

STANDARD FOR MODELS

DLC400BP

12-1/4"

T930L-E

MECHANISM ONLY

MECHANISM MECHANISM WITH BRACKET WITH BRACKET #62153-1 #64039

4"

1101NC DGLC100A-NC

1101-M-IAP

7200

1103NC DGLC200A-NC

1104-M-IAP

7202

1104NC

1102

7120

8001-NC

1103

7122

METAL INDOOR NEMA 1 ENCLOSURE #70100

DG SERIES

W200

W222L

E101PB

1103-N

W202

1847AW

E Series

W120

TU40

7-5/8"

1847AWL

DTU40

EW Series

11-7/8"

W220

DG Series DZS Series

TERMINAL BLOCK

MECHANISM ONLY GROUND 4-9/16 " SCREW

MECHANISM & BRACKET

CLEARANCE HOLE FOR GROUND SCREW

4-9/16 "

MODELS 5441

6-5/8 "

5-1/16" 4-9/16 "

7-5/8"

BRACKET

4-9/16 "

MECHANISM ONLY 4-9/16 "

3-5/8 "

TERMINAL BLOCK

MECHANISM & BRACKET

EWZ101-MB 2-3/32 "

E, EWZ, EH SERIES

EWZ103-MB

11-1/2"

BRACKET

SMC-3D

4-9/16MECHANISM " 3-5/8 " & BRACKET

6-5/8 "

EWZ201-MB

6-5/8 "

MECHANISM & BRACKET 3-3/8"

MECHANISM ONLY

EWZ120-MB 8-5/16"

3-1/16 "

2-1/2"

1-15/16 "

14-1/8"

12-3/4"

3-1/2"

TERMINAL BLOCK

MECHANISM & BRACKET DG SERIES

WIRING COMPARTMENT 10-1/8"

WITH MOUNTING BRACKET #64039

STINGL

3/4" or 1" KO

7-5/8"

6-5/8 "

3-5/8 "

1/2" or 3/4" KO

3-1/16"

Note: Indoor Enclosure Only

11-1/2"

TERMINAL BLOCK

TERMINAL BLOCK

9000PC 3-1/16"

1-15/16 "

DZS, DTS, DZM, DW, DWZ SERIES

3-1/4"

STANDARD FOR MODELS

W400A

1101D

1101DF

W402A

1114D

1114DF

W400AL

1104D

1104DF

METAL DUPLEX INDOOR/OUTDOOR NEMA 3 MODEL #9004L

4-9/16 "

4-9/16 "

6-5/8 "

EW103B-C EW120B-C

TERMINAL BLOCK

3-1/16 "

DZM, DW, DWZ BRACKET SERIES

6-5/8 "

TERMINAL BLOCK

1-15/16 "

MECHANISM & BRACKET DZS, DTS,

MECHANISM ONLY

PLASTIC INDOOR/OUTDOOR NEMA 3R WITH CLEAR WINDOW

MODELS

4-9/16 "

TERMINAL BLOCK

1-15/16 "

MECHANISM & BRACKET

8-5/16"

STANDARD FOR MODELS

SMC-3D

3-1/16 "

MECHANISM & BRACKET E, EWZ, 3-3/8"

EH

SERIES

MECHANISM ONLY

LC200M

MODELS

TERMINAL BLOCK

4-17/32 "

1102-M

1103-M

1104-M SMC-3D 8001-LC/WB

DTWH40

8601

8121

8602

8061

5-1/2"

3.4000"

EJWT E500T

MECHANISM & BRACKET 3-13/32 "

E501T

7 1/2” 7 1/ ” 2

1-13/16 "

9-3/8"

7-1/2"

PP-20RPP-20R PP-20R-P1 PP-20R-P1 PP20R-P4 PP20R-P4 PP-20R-2P1 PP-20R-2P1 PP-20R-2P4 PP-20R-2P4

MECHANISMS/BRACKETS

5-37/64 " 3-1/16 "

STANDARD FOR MODELS

STANDARD FOR MODELS 1101-O

1104-O

7302, L, Z, ZL 8001U-0

1102-0

7200-O

1103-0

7202-O

8007-0

POOL PANEL SERIES

4"

MECHANISM ONLY

METAL INDOOR/OUTDOOR NEMA 3 MODEL 9000B – SUFFIX "O"

LC200M MOUNTING WITH BRACKET

MODELS

4-11/16"

MECHANISM WITH BRACKET

LC200M

LC200M

MECHANISM & BRACKET 4-17/32 "

3-9/32 "

LDS LDSH

MECHANISM & BRACKET LC200M 3-13/32 "

LDS SERIES MOUNTING WITH BRACKET

MODELS

3.4000"

MECHANISM & BRACKET

LDS

1-13/16 "

2-1/8 "

4-17/32 "

LDSH

3-9/32 "

3.4000"

LDS LDSH

MECHANISM & BRACKET 3-13/32 "

13 3/8” 13 3/ ” 8

PP-100R PP-100R PP-100R-P4 PP-100R-P4 PP-100R-P1P4 PP-100R-P1P4 PP-100R-2P4 PP-100R-2P4 PP-100R-P4P4FM PP-100R-P4P4FM

17 3/4” 17 3/ ” 4

SHOWN WITH SNAP TRACK

3-3/8"

4 5/8” 4 5/ ” 8

4 1/4” 4 1/ ” 4

4"

7 1/2”

7300, L, Z, ZL 8001-0 8007U-0

4-11/16"

11”

3-3/4"

MECHANISM & BRACKET

8301 3-1/16"

11”

E502T

#64039/62153-1/65447

5-13/16 "

TERMINAL BLOCK

EWJT & E500T SERIES ENCLOSURE

SR-500PS

3-1/2"

4-9/16"

1-15/16 " 7000 Series 1847A, Z

1848A

3-9/32 "

STINGL SVRS ENCLOSURE

WITH MOUNTING BRACKET #62153-1

2-1/8 "

1101-M

MECHANISM & BRACKET

LDS LDSH

MECHANISM & BRACKET

MECHANISM & MOUNTING BRACKET #65446

6-5/8 "

4"

MODELS

SR-500

BRACKET

6-5/8 "

TERMINAL BLOCK

3-1/16 "

ADAPTER MECHANISM & BRACKET PLATE 4-9/16 "

MECHANISM ONLY

5-1/16"

NEMA 1 ENCLOSUREE, EWZ, EH SERIES

METAL INDOOR/OUTDOOR NEMA 3 MODEL 9000A – SUFFIX "0"

ELC712

1/2" or 3/4" KO 3/4" or 1" KO

2-3/32 "

6-5/8 "

ELC78

4-3/16"

8-3/4"

1/4" MOUNTING HOLE

W222

METAL INDOOR NEMA 1 ENCLOSURE FOR W400 SERIES

ELC78 & ELC712 ENCLOSURE

5401 ENCLOSURE

BRACKET

4-11/16"

DWZ Series

4"

12"

3-1/16 "

1-15/16 "

EWZ SERIES

MECHANISM ONLY

EWZ Series

DZM Series

STANDARD FOR MODELS

TERMINAL BLOCK

9000P

1102-N

SMC-3D

EW Series

PLASTIC INDOOR/OUTDOOR NEMA 3R #9000P

MODELS

7120Z, ZL

DW Series

E Series

7102

10"

5441 and 5440 REMOTE CONTACTORS

7202Z, ZL

DTS Series

7100

6-5/8 "

1104-N

18"

6-5/8 "

3-3/8"

W220L

BRACKET

3-5/8 "

4"

70100

W100

8001-N

4-9/16 "

12"

DWZ SERIES

1101-N

8001U-N

MECHANISM & BRACKET

2-3/32 "

ELC74 ENCLOSURE

ELC74

9/32" MOUNTING HOLES

TRP800

6-5/8 "

DZS, DTS,

7200Z, ZL

7122Z, ZL

4-9/16 "

4"

12"

TRP800

TRP 800 (GROUP OF 8)

9/32" MOUNTING HOLES

IAP BRACKET MECHANISM ONLY DG SERIES INTERMATIC ADAPTER PLATE

EWZ SeriesDZM, DW,

STANDARD FOR MODELS

10"

TRP800

NORYL® & LEXAN® INDOOR/OUTDOOR NEMA 3R MODEL #9000NC

14-1/4"

NORYL® INDOOR/OUTDOOR NEMA 3R MODEL #9000N

ELC72PC/277 18"

STANDARD FOR MODELS

DLC400BP

9/32" MOUNTING HOLES

ELC71PC/277

EW130B-Y EW120B-Y

METAL INDOOR NEMA 1 ENCLOSURE #63100

ELC71 & ELC72 SERIES ENCLOSURE

ELC71PC/120 ELC71PC/208-240

3-1/2"

TRP 400 (GROUP OF 4)

STANDARD FOR MODELS

TRP 800 (GROUP OF 8)

9/32" MOUNTING HOLES

TRP402

7-5/8"

Use Bracket #62153-1 W300

TRP400

TRP 400 (GROUP OF 4)

PP-20R PP-20R-P1 PP20R-P4 PP-20R-2P1 PP-20R-2P4

7 1/2”

PP-20R PP-20R-P1 PP20R-P4 PP-20R-2P1 PP-20R-2P4

1-13/16 "

11”

13 3/8”

13 3/8”

6 1/8” 6 1/ ” 8

12 3/4” 12 3/ ” 4

11”

PP-100R PP-100R PP-100R-P4 PP-100R-P4 PP-100R-P1P4 PP-100R-P1P4 PP-100R-2P4 PP-100R-2P4 PP-100R-P4P4FM PP-100R-P4P4FM

PP-125R PP-125R PP-125R-P4 PP-125R-P4 PP-125R-2P4 PP-125R-2P4 PP-125R-P4-100X PP-125R-P4-100X PP-125R-P4-300X PP-125R-P4-300X 17 3/ ” 17 3/ ” 4

4

PP-10R-M-GFCI PP-10R-M-GFCI PP-10R-E-GRCI PP-10R-E-GRCI

20 3/4” 20 3/ ” 4

9 3/4” 9 3/ ” 4

2-1/8 "

DZS100BP-0 DZS200BP-0 DZS200BP DW200B-0 DZM200BP-0

5-13/16 "

5-37/64 "

5-13/16 "

5-37/64 "

5401

4 1/4”

SHOWN WITH SNAP TRACK

4 5/8”

4 1/4”

4 5/8”

4 5/8” 4 5/ ” 8

4 1/2” 4 1/ ” 2

SHOWN WITH SNAP TRACK 12 3/4”

12 3/4”

PP-125R

PP-125R

6 1/8”

6 1/8”

TORK 153 PP-10R-M-GFCI PP-10R-M-GFCI

TORK 154

ALPHANUMERIC INDEX

ALPHANUMERIC INDEX

1101 . . . . . . . . . . . . . . . . . . . . . . . . . 31, 144

2104 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

652A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121

8001U-O . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

C512HH . . . . . . . . . . . . . . . . . . . . . . . . . . 106

DZS100BP-O . . . . . . . . . . . . . . . . . . . . . . . . 65

1101-7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

2107 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

654A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121

8004 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

C515M . . . . . . . . . . . . . . . . . . . . . . . . . . . 106

DZS200BP . . . . . . . . . . . . . . . . . . . . . . . . . . 65

1101D . . . . . . . . . . . . . . . . . . . . . . . . . . . 144

2115 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

655D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122

8007 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

C530M . . . . . . . . . . . . . . . . . . . . . . . . . . . 106

DZS200BP-12 . . . . . . . . . . . . . . . . . . . . . . . 65

1101FM-M . . . . . . . . . . . . . . . . . . . . . . . . 144

2116 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

701A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101

8007L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

C560M . . . . . . . . . . . . . . . . . . . . . . . . . . . 106

DZS200BP-24 . . . . . . . . . . . . . . . . . . . . . . . 65

1101FM-N . . . . . . . . . . . . . . . . . . . . . . . . . 144

2117 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

701AA . . . . . . . . . . . . . . . . . . . . . . . . . . . 101

8007-O . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

C560MH . . . . . . . . . . . . . . . . . . . . . . . . . . 106

DZS200BP-O . . . . . . . . . . . . . . . . . . . . . . . . 65

1101-M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

2223 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

711A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101

8007U . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

D1060LA . . . . . . . . . . . . . . . . . . . . . . . . . . 104

DZS400BP . . . . . . . . . . . . . . . . . . . . . . . . . 65

1101-M-IAP . . . . . . . . . . . . . . . . . . . . 31, 144

2224 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

7100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

8007U-O . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

D1060M . . . . . . . . . . . . . . . . . . . . . . . . . . 104

DZS400BP-O . . . . . . . . . . . . . . . . . . . . . . . . 65

1101-N . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

2421 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

7102 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

8007V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

D1060MW . . . . . . . . . . . . . . . . . . . . . . . . . 104

E101B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57

1101-NC . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

3000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

7120 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

8007VL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

D212H . . . . . . . . . . . . . . . . . . . . . . . . . . . 104

E101PB . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57

1101-O . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

3002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

7120L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

8008 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

D212HA . . . . . . . . . . . . . . . . . . . . . . . . . . 104

E103B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57

1102 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

3006 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

7120Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

8008L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

D212HW . . . . . . . . . . . . . . . . . . . . . . . . . . 104

E120B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57

1102-M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

3010 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

7120ZL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

8061 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

DG100A . . . . . . . . . . . . . . . . . . . . . . . . . . . 63

E201B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57

1102-N . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

401A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119

7122 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

8121 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

DG100A . . . . . . . . . . . . . . . . . . . . . . . . . . . 63

E500T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87

1102-O . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

402A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119

7122ZL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

8301 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

DG180A . . . . . . . . . . . . . . . . . . . . . . . . . . . 85

E501T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87

1103 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

403A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119

7200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

8601 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

DG200A . . . . . . . . . . . . . . . . . . . . . . . . . . . 63

E502T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87

1103-M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

405A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119

7200L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

90058-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . 94

DG280A . . . . . . . . . . . . . . . . . . . . . . . . . . . 85

EJWT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87

1103-N . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

422A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119

7200-O . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

A502H . . . . . . . . . . . . . . . . . . . . . . . . . . . 105

DG280A-24 . . . . . . . . . . . . . . . . . . . . . . . . . 85

ELC712 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75

1103-NC . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

454D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120

7200Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

A502HHW . . . . . . . . . . . . . . . . . . . . . . . . . 105

DGLC100A-NC . . . . . . . . . . . . . . . . . . . . . . . 79

ELC71PC/120 . . . . . . . . . . . . . . . . . . . . . . . 73

1103-O . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

455D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120

7200ZL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

A502HW . . . . . . . . . . . . . . . . . . . . . . . . . . 105

DGLC200A-NC . . . . . . . . . . . . . . . . . . . . . . . 79

ELC71PC/208-240 . . . . . . . . . . . . . . . . . . . 73

1104 . . . . . . . . . . . . . . . . . . . . . . . . . 31, 144

457Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120

7202 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

A506H . . . . . . . . . . . . . . . . . . . . . . . . . . . 105

DGM100A . . . . . . . . . . . . . . . . . . . . . . . . . . 63

ELC71PC/277 . . . . . . . . . . . . . . . . . . . . . . . 73

1104D . . . . . . . . . . . . . . . . . . . . . . . . . . . 144

460D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120

7202L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

A506HHW . . . . . . . . . . . . . . . . . . . . . . . . . 105

DGM100A-Y . . . . . . . . . . . . . . . . . . . . . . . . 63

ELC72PC/120 . . . . . . . . . . . . . . . . . . . . . . . 73

1104DF . . . . . . . . . . . . . . . . . . . . . . . . . . . 144

5001M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

7202-O . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

A506HW . . . . . . . . . . . . . . . . . . . . . . . . . . 105

DGS100A . . . . . . . . . . . . . . . . . . . . . . . . . . 85

ELC72PC/208-240 . . . . . . . . . . . . . . . . . . . 73

1104FM-M . . . . . . . . . . . . . . . . . . . . . . . . 144

5004M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

7202Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

A512H . . . . . . . . . . . . . . . . . . . . . . . . . . . 105

DGS100A-12 . . . . . . . . . . . . . . . . . . . . . . . . 85

ELC72PC/277 . . . . . . . . . . . . . . . . . . . . . . . 73

1104FM-N . . . . . . . . . . . . . . . . . . . . . . . . . 144

5007M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

7202ZL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

A512HH . . . . . . . . . . . . . . . . . . . . . . . . . . 105

DGS100A-24 . . . . . . . . . . . . . . . . . . . . . . . . 85

ELC74 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75

1104-M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

5008M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

7220 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

A512HHW . . . . . . . . . . . . . . . . . . . . . . . . . 105

DGU100A-Y . . . . . . . . . . . . . . . . . . . . . . . . . 79

ELC78 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75

1104-M-IAP . . . . . . . . . . . . . . . . . . . . 31, 144

5021M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

7220L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

A512HW . . . . . . . . . . . . . . . . . . . . . . . . . . 105

DGUM100A . . . . . . . . . . . . . . . . . . . . . . . . . 79

ELS-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115

1104-N . . . . . . . . . . . . . . . . . . . . . . . . . . . 144

5024M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

7222 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

A515M . . . . . . . . . . . . . . . . . . . . . . . . . . . 105

DGUM100A-Y . . . . . . . . . . . . . . . . . . . . . . . 79

EPC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77

1104-NC . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

5026M . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

7222L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

A515MA . . . . . . . . . . . . . . . . . . . . . . . . . . 105

DIN100B . . . . . . . . . . . . . . . . . . . . . . . . . . . 89

EPC2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81

1104-O . . . . . . . . . . . . . . . . . . . . . . . . 31, 144

5231 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

7300 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

A515MH . . . . . . . . . . . . . . . . . . . . . . . . . . 105

DIN200B . . . . . . . . . . . . . . . . . . . . . . . . . . . 89

EPC-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79

1847A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

5237 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

7300L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

A515MHW . . . . . . . . . . . . . . . . . . . . . . . . . 105

DLC400BP . . . . . . . . . . . . . . . . . . . . . . . . . . 81

EPC-LC . . . . . . . . . . . . . . . . . . . . . . . . . . 73, 75

1847AL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

5401 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92

7300Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

A515MW . . . . . . . . . . . . . . . . . . . . . . . . . . 105

DS12X12H . . . . . . . . . . . . . . . . . . . . . . . . 151

1847AW . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

5403 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

7300ZL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

A530M . . . . . . . . . . . . . . . . . . . . . . . . . . . 105

DS12X12P . . . . . . . . . . . . . . . . . . . . . . . . . 151

EW101B . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 EW103B . . . . . . . . . . . . . . . . . . . . . . . . . . . 59

1847AWL . . . . . . . . . . . . . . . . . . . . . . . . . . 41

5404 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

7302 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

A530MA . . . . . . . . . . . . . . . . . . . . . . . . . . 105

DS360M . . . . . . . . . . . . . . . . . . . . . . . . . . 151

EW103B-C . . . . . . . . . . . . . . . . . . . . . . . . . . 59

1847AZ . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

5404-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

7302L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

A530MH . . . . . . . . . . . . . . . . . . . . . . . . . . 105

DS-AA . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152

EW103B-Y . . . . . . . . . . . . . . . . . . . . . . . . . . 59

1847AZL . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

5420 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

7302Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

A530MHW . . . . . . . . . . . . . . . . . . . . . . . . . 105

DS-MR . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152

EW120B . . . . . . . . . . . . . . . . . . . . . . . . . . . 59

1848A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

5441 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92

7302ZL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

A530MW . . . . . . . . . . . . . . . . . . . . . . . . . . 105

DTS100B . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

EW120B-C . . . . . . . . . . . . . . . . . . . . . . . . . . 59

2000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

5500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

73866 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

A560M . . . . . . . . . . . . . . . . . . . . . . . . . . . 105

DTS200B . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

EW120B-Y . . . . . . . . . . . . . . . . . . . . . . . . . . 59

2000-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

803B . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123

A560MH . . . . . . . . . . . . . . . . . . . . . . . . . . 105

DTS400B . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

EW201B . . . . . . . . . . . . . . . . . . . . . . . . . . . 59

2000-7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

5500-OC . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 5737TM . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

806B . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123

A560MHW . . . . . . . . . . . . . . . . . . . . . . . . . 105

DTU40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

EW201B-Y . . . . . . . . . . . . . . . . . . . . . . . . . . 59

2001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

5737TZ . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

806D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123

A560MW . . . . . . . . . . . . . . . . . . . . . . . . . . 105

DTWH40 . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

EWZ101 . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

2002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

601A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121

8001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

AV20X20 . . . . . . . . . . . . . . . . . . . . . . . . . 151

DW200B . . . . . . . . . . . . . . . . . . . . . . . . . . 145

EWZ101-MB . . . . . . . . . . . . . . . . . . . . . . . . 61

2005A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

602A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121

8001-LC/WB . . . . . . . . . . . . . . . . . . . . . . . . 37

AV26X26 . . . . . . . . . . . . . . . . . . . . . . . . . . 151

DW200B-O . . . . . . . . . . . . . . . . . . . . . . . . 145

EWZ103 . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

2007A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

611A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121

8001-N . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

C412H . . . . . . . . . . . . . . . . . . . . . . . . . . . 106

DTWH40 . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

EWZ103-MB . . . . . . . . . . . . . . . . . . . . . . . . 61

2008A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

611D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122

8001-NC . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

C460M . . . . . . . . . . . . . . . . . . . . . . . . . . . 106

DWZ100B . . . . . . . . . . . . . . . . . . . . . . . . . . 69

EWZ120 . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

2021 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

621D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122

8001-O . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

C502H . . . . . . . . . . . . . . . . . . . . . . . . . . . 106

DZM200BP . . . . . . . . . . . . . . . . . . . . . . . . . 71

EWZ120-MB . . . . . . . . . . . . . . . . . . . . . . . . 61

2022 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

631D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122

8001U . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

C506H . . . . . . . . . . . . . . . . . . . . . . . . . . . 106

DZM200BP-O . . . . . . . . . . . . . . . . . . . . . . . 71

EWZ201 . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

2101 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

640-475XV . . . . . . . . . . . . . . . . . . . . . . . . 151

8001U-N . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

C512H . . . . . . . . . . . . . . . . . . . . . . . . . . . 106

DZS100BP . . . . . . . . . . . . . . . . . . . . . . . . . . 65

EWZ201-MB . . . . . . . . . . . . . . . . . . . . . . . . 61

TORK 155

TORK 156

ALPHANUMERIC INDEX

ALPHANUMERIC INDEX

HPS30 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93

PFP2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143

T920L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

TA503 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133

TA93-2RN5 . . . . . . . . . . . . . . . . . . . . . . . . 135

TCHD1ARP-MK2 . . . . . . . . . . . . . . . . . . . . . 152

LC200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77

PFP2-M . . . . . . . . . . . . . . . . . . . . . . . . . . 147

T920L-E . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

TA503SW . . . . . . . . . . . . . . . . . . . . . . . . . 138

TA94AN5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135

TCHD2L2-MK2 . . . . . . . . . . . . . . . . . . . . . . 152

LC200M . . . . . . . . . . . . . . . . . . . . . . . . . . . 77

PFP3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143

T920L-O . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

TA52AN5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135

TA94BN5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135

TCHD2RP-MK2 . . . . . . . . . . . . . . . . . . . . . . 152

LCS115M . . . . . . . . . . . . . . . . . . . . . . . 75, 112

PFP3-M . . . . . . . . . . . . . . . . . . . . . . . . . . . 147

T930L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

TA52BN5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135

TA94RN5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135

TRP-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94

LDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83

PFPEW1102 . . . . . . . . . . . . . . . . . . . . . . . 143

T930L-E . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

TA52RN5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135

TA-ADA . . . . . . . . . . . . . . . . . . . . . . . . . . . 138

TRP-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94

LDS-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83

PFPEW1102-M . . . . . . . . . . . . . . . . . . . . . . 148

T930L-O . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

TA53AE1 . . . . . . . . . . . . . . . . . . . . . . . . . . 136

TA-ADB . . . . . . . . . . . . . . . . . . . . . . . . . . . 138

TRP400 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94

LDSH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83

PFPEW1103 . . . . . . . . . . . . . . . . . . . . . . . 143

TA09 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133

TA53AF1 . . . . . . . . . . . . . . . . . . . . . . . . . . 136

TA-ADR . . . . . . . . . . . . . . . . . . . . . . . . . . . 138

TRP402 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94

LDSH-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83

PFPEW1103-M . . . . . . . . . . . . . . . . . . . . . . 148

TA1245Y-50 . . . . . . . . . . . . . . . . . . . . . . . 137

TA53AG . . . . . . . . . . . . . . . . . . . . . . . . . . . 136

TA-B1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138

TRP800 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94

MLS2RPAKA . . . . . . . . . . . . . . . . . . . . . . . . 152

PFPT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143

TA1245Y-75 . . . . . . . . . . . . . . . . . . . . . . . 137

TA53RE1 . . . . . . . . . . . . . . . . . . . . . . . . . . 136

TA-B2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138

TRP802 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94

MLSPACER . . . . . . . . . . . . . . . . . . . . . . . . . 152

PP-100R . . . . . . . . . . . . . . . . . . . . . . . . . . 141

TA131DAN5 . . . . . . . . . . . . . . . . . . . . . . . 136

TA54AE1 . . . . . . . . . . . . . . . . . . . . . . . . . . 136

TA-B3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138

TRP-U . . . . . . . . . . . . . . . . . . . . . 79, 112, 116

MLTPRP . . . . . . . . . . . . . . . . . . . . . . . . . . . 152

PP-100R-2P4 . . . . . . . . . . . . . . . . . . . . . . 141

TA131DAU . . . . . . . . . . . . . . . . . . . . . . . . 136

TA54RE1 . . . . . . . . . . . . . . . . . . . . . . . . . . 136

TA-B-8332 . . . . . . . . . . . . . . . . . . . . . . . . . 132

TU40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

MLTPS2BGA . . . . . . . . . . . . . . . . . . . . . . . . 152

PP-100R-F2F4FM . . . . . . . . . . . . . . . . . . . . 143

TA131DRN5 . . . . . . . . . . . . . . . . . . . . . . . 136

TA5508H-G1 . . . . . . . . . . . . . . . . . . . . . . . 127

TA-BBSF . . . . . . . . . . . . . . . . . . . . . . . . . . 138

TU40-Y . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

MLVPRP . . . . . . . . . . . . . . . . . . . . . . . . . . . 152

PP-100R-P4 . . . . . . . . . . . . . . . . . . . . . . . 141

TA131DRU1 . . . . . . . . . . . . . . . . . . . . . . . 136

TA590 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137

TA-B-KHD-1000-PP . . . . . . . . . . . . . . . . . . 131

TW-220L . . . . . . . . . . . . . . . . . . . . . . . . . . . 47

MLVPS2BGA . . . . . . . . . . . . . . . . . . . . . . . . 152

PP-100R-P4P1 . . . . . . . . . . . . . . . . . . . . . . 141

TA152 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133

TA591 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137

TA-B-KHD-120VAC . . . . . . . . . . . . . . . . . . 131

TW-220L-E . . . . . . . . . . . . . . . . . . . . . . . . . 47

OSC10U . . . . . . . . . . . . . . . . . . . . . . . . . . 114

PP-100R-P4P4FM . . . . . . . . . . . . . . . . . . . 141

TA154 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133

TA592 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137

TA-B-KHS-1000-PP . . . . . . . . . . . . . . . . . . 131

TW-222L . . . . . . . . . . . . . . . . . . . . . . . . . . . 47

OSC12PL . . . . . . . . . . . . . . . . . . . . . . . . . . 112

PP-10R-E-GFCI . . . . . . . . . . . . . . . . . . . . . . 141

TA1786B . . . . . . . . . . . . . . . . . . . . . . . . . . 134

TA598 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137

TAC210W . . . . . . . . . . . . . . . . . . . . . . . . . 129

TW-300L . . . . . . . . . . . . . . . . . . . . . . . . . . . 47

OSC15PLS . . . . . . . . . . . . . . . . . . . . . . . . . 111

PP-10R-M-GFCI . . . . . . . . . . . . . . . . . . . . . 141

TA1786CB . . . . . . . . . . . . . . . . . . . . . . . . . 134

TA599 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137

TAC212WL . . . . . . . . . . . . . . . . . . . . . . . . 129

TW-302L . . . . . . . . . . . . . . . . . . . . . . . . . . . 47

OSC20U . . . . . . . . . . . . . . . . . . . . . . . . . . 114

PP-125-2P4 . . . . . . . . . . . . . . . . . . . . . . . 141

TA1880 B . . . . . . . . . . . . . . . . . . . . . . . . . 132

TA60 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133

TAC212WS . . . . . . . . . . . . . . . . . . . . . . . . . 129

TZ-220L . . . . . . . . . . . . . . . . . . . . . . . . . . . 49

OSC5PL . . . . . . . . . . . . . . . . . . . . . . . . . . . 112

PP-125R . . . . . . . . . . . . . . . . . . . . . . . . . . 141

TA1880 G . . . . . . . . . . . . . . . . . . . . . . . . . 132

TA600 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134

TA-D5B . . . . . . . . . . . . . . . . . . . . . . . . . . . 138

TZ220L-O . . . . . . . . . . . . . . . . . . . . . . . . . . 49

OSC5U . . . . . . . . . . . . . . . . . . . . . . . . . . . 114

PP-125R-P4 . . . . . . . . . . . . . . . . . . . . . . . 141

TA1882 B . . . . . . . . . . . . . . . . . . . . . . . . . 132

TA601 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134

TA-D6A . . . . . . . . . . . . . . . . . . . . . . . . . . . 138

TZ-222L . . . . . . . . . . . . . . . . . . . . . . . . . . . 49

OSCS20UP . . . . . . . . . . . . . . . . . . . . . . . . . 113

PP-125R-P4-100X . . . . . . . . . . . . . . . . . . . 141

TA1882 G . . . . . . . . . . . . . . . . . . . . . . . . . 132

TA602 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134

TA-D6C . . . . . . . . . . . . . . . . . . . . . . . . . . . 138

TZ-300L . . . . . . . . . . . . . . . . . . . . . . . . . . . 49

OSWS9P-120 . . . . . . . . . . . . . . . . . . . . . . . 110

PP-125R-P4-300X . . . . . . . . . . . . . . . . . . . 141

TA1886 B . . . . . . . . . . . . . . . . . . . . . . . . . 132

TA603L . . . . . . . . . . . . . . . . . . . . . . . . . . . 134

TA-D6R . . . . . . . . . . . . . . . . . . . . . . . . . . . 138

TZ-300L-O . . . . . . . . . . . . . . . . . . . . . . . . . . 49

OSWS9P-277 . . . . . . . . . . . . . . . . . . . . . . . 110

PP-20R . . . . . . . . . . . . . . . . . . . . . . . . . . . 141

TA1886 G . . . . . . . . . . . . . . . . . . . . . . . . . 132

TA606 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137

TA-D7A . . . . . . . . . . . . . . . . . . . . . . . . . . . 138

TZ-302L . . . . . . . . . . . . . . . . . . . . . . . . . . . 49

OSWS9PD . . . . . . . . . . . . . . . . . . . . . . . . . 110

PP-20R-2P1 . . . . . . . . . . . . . . . . . . . . . . . 141

TA1887 B . . . . . . . . . . . . . . . . . . . . . . . . . 132

TA61 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133

TA-D7B . . . . . . . . . . . . . . . . . . . . . . . . . . . 138

USB-MMP . . . . . . . . . . . . . . . . . . . . . . . . . . 65

OSWS9PDM . . . . . . . . . . . . . . . . . . . . . . . . 110

PP-20R-2P4 . . . . . . . . . . . . . . . . . . . . . . . 141

TA1887 BK . . . . . . . . . . . . . . . . . . . . . . . . 132

TA62 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133

TA-D7C . . . . . . . . . . . . . . . . . . . . . . . . . . . 138

W100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

P1101-2M . . . . . . . . . . . . . . . . . . . . . . . . . 147

PP-20R-F2 . . . . . . . . . . . . . . . . . . . . . . . . . 143

TA1887 G . . . . . . . . . . . . . . . . . . . . . . . . . 132

TA620 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134

TA-D7R . . . . . . . . . . . . . . . . . . . . . . . . . . . 138

W120 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

P1101FM-M . . . . . . . . . . . . . . . . . . . . . . . 147

PP-20R-P1 . . . . . . . . . . . . . . . . . . . . . . . . 141

TA215LB . . . . . . . . . . . . . . . . . . . . . . . . . . 134

TA620B . . . . . . . . . . . . . . . . . . . . . . . . . . . 134

TA-D8A . . . . . . . . . . . . . . . . . . . . . . . . . . . 138

W200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

P1101-M . . . . . . . . . . . . . . . . . . . . . . . . . . 147

PP-20R-P4 . . . . . . . . . . . . . . . . . . . . . . . . 141

TA236 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133

TA620L . . . . . . . . . . . . . . . . . . . . . . . . . . . 134

TA-D8R . . . . . . . . . . . . . . . . . . . . . . . . . . . 138

W202 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

P1104-2M . . . . . . . . . . . . . . . . . . . . . . . . . 147

SMC3D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91

TA270A . . . . . . . . . . . . . . . . . . . . . . . . . . . 130

TA620LB . . . . . . . . . . . . . . . . . . . . . . . . . . 134

TA-L10 . . . . . . . . . . . . . . . . . . . . . . . . . . . 138

W220 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

P1104FM-M . . . . . . . . . . . . . . . . . . . . . . . 147

SR-500 . . . . . . . . . . . . . . . . . . . . . . . . . . . 149

TA315-1N5 . . . . . . . . . . . . . . . . . . . . . . . . 130

TA631L . . . . . . . . . . . . . . . . . . . . . . . . . . . 134

TA-L10-1 . . . . . . . . . . . . . . . . . . . . . . . . . . 138

W220L . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

P1104FM-M 240VAC . . . . . . . . . . . . . . . . . 143

SR-500PS . . . . . . . . . . . . . . . . . . . . . . . . . 149

TA340-10G5 . . . . . . . . . . . . . . . . . . . . . . . 128

TA635 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134

TA-L12 . . . . . . . . . . . . . . . . . . . . . . . . . . . 138

P1104-M . . . . . . . . . . . . . . . . . . . . . . . . . . 147

SR-ESB . . . . . . . . . . . . . . . . . . . . . . . . . . . 152

TA340-4G5 . . . . . . . . . . . . . . . . . . . . . . . . 128

TA640 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137

TA-L3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138

W222 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 W222L . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

PB-100 . . . . . . . . . . . . . . . . . . . . . . . . . . . 148

SR-RA . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152

TA340-4N5 . . . . . . . . . . . . . . . . . . . . . . . . 128

TA656B . . . . . . . . . . . . . . . . . . . . . . . . . . . 134

TA-L4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138

W300 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

PB-50 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148

SS13B . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103

TA340-6G5 . . . . . . . . . . . . . . . . . . . . . . . . 128

TA666BK . . . . . . . . . . . . . . . . . . . . . . . . . . 134

TA-L6-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . 138

W300L . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

PB-75 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148

SS13F . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103

TA340-6N5 . . . . . . . . . . . . . . . . . . . . . . . . 128

TA725 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129

TA-L8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138

W300-O . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

PEW101-M . . . . . . . . . . . . . . . . . . . . . . . . 148

SS20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103

TA371LRN5 . . . . . . . . . . . . . . . . . . . . . . . . 135

TA740 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129

TA-L9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138

W302 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

PEW104-M . . . . . . . . . . . . . . . . . . . . . . . . 148

SS20F . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103

TA434-10N5 . . . . . . . . . . . . . . . . . . . . . . . 128

TA744 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129

TA-M1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138

W302L . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

PF1101FM-M . . . . . . . . . . . . . . . . . . . . . . . 147

TA434-6N5 . . . . . . . . . . . . . . . . . . . . . . . . 128

TA874-N5 . . . . . . . . . . . . . . . . . . . . . . . . . 127

TA-MTS . . . . . . . . . . . . . . . . . . . . . . . . . . . 128

W400A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

PF1101-M . . . . . . . . . . . . . . . . . . . . . . . . . 147

SS700Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 SS700ZA . . . . . . . . . . . . . . . . . . . . . . . . . . . 99

TA44 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133

TA874-N5R . . . . . . . . . . . . . . . . . . . . . . . . 127

TA-SFPF . . . . . . . . . . . . . . . . . . . . . . . . . . . 138

W400AL . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

PF1104FM-M . . . . . . . . . . . . . . . . . . . . . . . 147

SS720A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98

TA45 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133

TA875-1G1 . . . . . . . . . . . . . . . . . . . . . . . . 128

TA-SFPFR . . . . . . . . . . . . . . . . . . . . . . . . . . 138

W402A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

PF1104-M . . . . . . . . . . . . . . . . . . . . . . . . . 147

SS720AA . . . . . . . . . . . . . . . . . . . . . . . . . . . 98

TA46 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133

TA875-G1 . . . . . . . . . . . . . . . . . . . . . . . . . 127

TA-WBBF . . . . . . . . . . . . . . . . . . . . . . . . . . 138

PFEW101-M . . . . . . . . . . . . . . . . . . . . . . . 148

SS721Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99

TA47AN5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135

TA876-N5 . . . . . . . . . . . . . . . . . . . . . . . . . 127

TCA1-MK2 . . . . . . . . . . . . . . . . . . . . . . . . . 152

PFEW104-M . . . . . . . . . . . . . . . . . . . . . . . 148

SS721ZA . . . . . . . . . . . . . . . . . . . . . . . . . . . 99

TA47AR5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135

TA879 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136

TCA1RP-MK2 . . . . . . . . . . . . . . . . . . . . . . . 152

PFP1102 . . . . . . . . . . . . . . . . . . . . . . . . . . 143

SSA100 . . . . . . . . . . . . . . . . . . . . . . . . . . . 102

TA47RN5 . . . . . . . . . . . . . . . . . . . . . . . . . . 135

TA880-N5 . . . . . . . . . . . . . . . . . . . . . . . . . 127

TCA3-MK2 . . . . . . . . . . . . . . . . . . . . . . . . . 152

PFP1102-M . . . . . . . . . . . . . . . . . . . . . . . . 147

SSA100R-24 . . . . . . . . . . . . . . . . . . . . . . . 102

TA502 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133

TA93-2AN5 . . . . . . . . . . . . . . . . . . . . . . . . 135

TCA3RP-MK2 . . . . . . . . . . . . . . . . . . . . . . . 152

PFP1103 . . . . . . . . . . . . . . . . . . . . . . . . . . 143

SSA200 . . . . . . . . . . . . . . . . . . . . . . . . . . . 102

TA502-BX . . . . . . . . . . . . . . . . . . . . . . . . . 138

TA93-2BN5 . . . . . . . . . . . . . . . . . . . . . . . . 135

TCAMA2RND . . . . . . . . . . . . . . . . . . . . . . . 152

PFP1103-M . . . . . . . . . . . . . . . . . . . . . . . . 147

SSA200R-24 . . . . . . . . . . . . . . . . . . . . . . . 102

TA502SW . . . . . . . . . . . . . . . . . . . . . . . . . 138

TA93-2CN5 . . . . . . . . . . . . . . . . . . . . . . . . 135

TCHD1AL2-MK2 . . . . . . . . . . . . . . . . . . . . . 152

TORK 157

TORK 158

NOTES

TERMS OF SALE

TORK VENDOR NUMBER: 662381 1. Prices are F.O.B. our plant. 2. Prices do not include any sales tax. 3. Freight charges will be prepaid on all orders $100.00 and over shipping ­within continental USA using standard shipping methods and service. 4. Minimum order – $100.00. 5. Claims for shortage, erroneous charges or price corrections shall be deemed waived unless made in writing, delivered to NSi within 30 days of invoice. 6. Terms of payment – 2% 10th prox. net 25th following. 7. Warranties – We strive to produce the highest quality products on the market today. NSi guarantees all products to be free of defects in material and workmanship for a period of 90 days from date of sale. Any claims for defective material must be agreed to in writing by NSi. Defective material will be replaced on an F.O.B., our factory basis. NSi disclaims the implied warranty of fitness for a particular application.

OTHER PRODUCTS AVAILABLE

ADDRESS 9730 Northcross Center Court Huntersville, North Carolina 28078 USA PHONE office 800.321.5847 technical support 888.500.4598 FAX 800.841.5566

EMAIL [email protected]

WEB www.nsiindustries.com

NSi can provide many other products for special applications which are not ­listed in this catalog. If you require an item which you do not find listed, please contact us. We would be pleased to provide a quotation upon receipt of a ­drawing or a sample.

GUARANTEE

It is our goal to provide extraordinary products and services on a daily basis. If our products or service do not meet with your satisfaction, please let us know ­immediately and we promise to make every reasonable effort to remedy the ­situation.