Temp 30 4

75 [19] 801 Avenida Acaso, Camarillo, Ca. 93012 • (805) 494-0622 • www.sdcsecurity.com • E-mail: [email protected]...

1 downloads 44 Views 71KB Size
.75 [19]

801 Avenida Acaso, Camarillo, Ca. 93012 • (805) 494-0622 • www.sdcsecurity.com • E-mail: [email protected]

1.00 [25]

30-4 Frame Preparation Method of installation may vary per door, frame and lockset manufacturer. Left handed door installation shown.

4.13 [105]

.84 [21]

*

3.94 [100]

CL of Pullman Latch

.84 [21] .63 [16]

4.13 [105]

.12 [3]

*

2.00 [51]

CL of Cutout

CL

.41 [10]

Model 30-4 Electric Strike

3.89 [99] 2X 1/4-20 UNC

.50 [13]

CL of Keeper

1.74 [44]

9.00 [229]

.95 [24] .51 [13]

1.70 [43]

1.09 [28]

1.13 [29]

1.75 [44]

CL

Face of stop

Set Screw Locations

.33 [8] 1.34 [34]

.33 [8]

*

Dimensions are flipped for right handed door installations

Spacer Removal A 1/4” spacer plate is preinstalled to the strike faceplate. Removal of the spacer plate will decrease the faceplate thickness from .75" to .50". To remove spacer follow these steps: 1. Remove strike body from faceplate. 2. Remove four #8-32 screws and two #2-56 screws as shown on left. 3. Remove spacer. 4. Re-attach strike body to faceplate.

30-4 ELECTRIC STRIKE AND FRAME, PREP. TEMPLATE

Horizontal Adjustability #2-56

#8-32 NOTE: Not compatible with SDC 6000 series Rim Devices. Check Manufacturers exit device template for compatibility.

Faceplate

#1/4-20

1. Loosen the two #1/4-20 socket cap screws as shown to the right. 2. Adjust strike to appropriate horizontal position. 3. Tighten the two #1/4-20 socket cap screws. 4. Lock down adjustment by installing the provided set screws.

Spacer P:\INSTALLATION INST\Electric Strikes\Temp-30-4\TEMP-30-4.vsd

REV C

12-10

Page 1

Any suggestions or comments to this instruction or product are welcome. Please contact us through our website or email [email protected]

TEMP-30-4