SOLSHEET SAM Self Adhesive Membrane SOLSHEET Self Adhesive Membrane is a 1.5mm thick preformed waterproofing system, compatible with concrete, smooth brickwork and blockwork or screeded substrates and is resistant to those chemicals likely to be present in normal service conditions. ■ Cross-laminated film – provides dimensional stability, high tear strength, puncture and impact resistance. ■ Polymer modified bitumen coating. ■ Cold applied – no heating via flames or hot bitumen on site. ■ Flexible – will accommodate minor settlement and shrinkage. ■ Comprehensive range of accessories and ancillary products. ■ Full design and on-site technical support. ■ Specification compliant with BS 8102:2009. ■ BBA Approved & CE Marked. ■ Compliant with NHBC Standards.

Product Details 1.5mm ± 0.2

Thickness Widths (m)

100mm / 150mm / 300mm / 1.0m

Length (m)

20m

Roll Weight

3kg / 4.5kg / 9Kg / 30kg

Colour

Black

Coverage

18.9m2 (inc. Standard Laps)

SOLSHEET - Waterproofing Systems

Last Issue Date: 01.01.19 Rev 3

Description TYPE A

SOLSHEET Self Adhesive Membrane is a 1.5mm thick, crosslaminated, polythene membrane coated on the lower surface with a layer of polymer-modified bitumen. The membrane is protected on the self adhesive side with a silicone coated release film. Substrates should be primed with SOLSEAL Bitumen Primer prior to application.

EN 13969 DPC / Cavity Tray Cavity Wall

Solsheet Self-Adhesive can be internally or externally applied to provide an effective barrier to the transmission of liquid water, where grades 1-3 waterproofing protection is required, as stated in BS 8102 : 2009. Technical Data

Value

Test Method

Watertightness

Pass (10 kPA)

EN 1928:2000 (B)

Solsheet SA Membrane Solco Protection Board

Earth

Longitudinal tensile strength

270 ± 70 N/50 mm

UNE-EN 12311-1

Transversal tensile strength

270 ± 70 N/50 mm

UNE-EN 12311-1

Longitudinal elongation at break

250 ± 50 %

UNE-EN 12311-1

Transversal elongation at break

250 ± 50 %

UNE-EN 12311-1

Resistance to root penetration

Pass

prEN 13984

Resistance to static loading

≥5 Kg

UNE-EN 12730 (A)

Typical Detail

NPD

UNE-EN 12691

Please contact our Technical department for project specific application details

180 ± 50 N

UNE-EN 12310-1

Technical Data

Value

Test Method

140 ± 50 N

UNE-EN 12310-1

Mass per unit area (nominal)

1.5 kg/m²

EN 1849-1

Joint strength: peel resistance

100 ± N/50 mm

UNE-EN 12316-1

Mass per unit area (minimum)

1.43 kg/m²

EN 1849-1

Joint strength: shear resistance

270 ± 70 N/50 mm

UNE-EN 12317-1

Nominal thickness

1.5 mm

EN 1849-1

Flexibility at low temperature

≤ -15 °C

UNE-EN 1109

Water Vapour Transmission properties

71800

UNE-EN 1931

Resistance to impact Longitudinal resistance to tearing (nail shank) Transversal resistance to tearing (nail shank)

Technical Support: 0808 168 6927

Solsheet SA Membrane

Solco Protection Board

www.solco.co.uk

[email protected]

Datasheet

Self Adhesive Membrane Installation Guide Surface Preparation: Applied To Concrete, Masonry, Steel & Timber All surfaces should be smooth, clean and dry. Loosely adhering material and sharp protrusions should be removed by mechanical means. Concrete or renders should be allowed to dry before applying Solsheet membrane.

Priming: All vertical surfaces should be primed using Solseal HP Emulsion/Primer. Horizontal surfaces do not require priming where the membrane is covered with a screed, floorslabetc.Primingshouldbecarriedoutasfollows: 1. 2. 3.

Roll can well before use. Apply at the rate of approximately 6m2/L. Only prime the area which is to be covered with Solsheet within the next 4 hours. Allow to dry for at least 1 hour until touch dry. Keep free from dust. On very porous surfaces, use two coats of primer.

Application: Waterproofing of Basements, Ground Floors, Reservoirs & Retaining Walls. Internal angles must always be provided with an adequate sand/cement fillet. After priming as previously described a 300mm wide reinforcing strip of Solsheet must be applied with 150mm on either side of the centre of the fillet. External angles or corners must be provided with a 25mm x 25mm splay and this covered with a 300mm wide strip of Solsheet XL, applied equidistant from the centre of the splay.# Horizontal membrane: This should preferably be laid prior to the application of the vertical membrane, adequately protected from damage by a minimum 25mm screed or protection board, with the membrane bonded to the vertical surface at least 200mm above the top of the screed so that the vertical Solsheet can be overlaid. If it is not possible to apply the screed over the DPM before the application of the vertical membrane, full and adequate protection must be given to the horizontal membrane to prevent damage. Vertical membrane: Cut off the appropriate length of membrane, then starting at the top of the area to be waterproofed, peel off at least 200mm of release sheet and bond the Solsheet firmly to the surface, tucking the end of the material into the appropriate DPC or chase. Gradually peel off the remainder of the release sheet downwards, at the same time rolling the material against the surface until the bottom of the wall is reached. At the base, the vertical membrane must overlap the horizontal membrane by at least 100mm. All subsequent sheets must overlap the preceding sheet by 50mm at the edges and by 100mm at ends. Overlaps must be thoroughly rolled to ensure adequate bonding. Backfilling: On vertical applications where an abrasive backfill is to be used the Solsheet membrane should be protected by a concrete outer skin, brick skin or Solsheet protection board, the latter being held in place by Solco 50mm Butyl tape. Precautions: Solsheet and Solsheet Primer must not be applied when the surface temperature of the substrate falls below 5°C. When a brick-skin is applied to the face of the vertical Solsheet, care must be taken not to damage the membrane and a gap of 40mm should be left which is filled with sand/cement mortar as work proceeds. Only sufficient Solsheet should be laid which can be protected as work proceeds. When areas of Solsheet are left exposed for any length of time ensure that all edges are held in place by battens. Storage & Handling on site: SOLSHEET Self Adhesive Membrane is classified as non-hazardous (code of practice CP102 1973). The product is chemically inert and any acids or alkalis present in the subsoil will not affect the membrane. It is not recommended for use when exposed to sunlight and general outdoor weather conditions for long periods of time. Weathering will not occur when installed. Rolls should be stored undercover. Quality control during the laying of the membrane is extremely important the membrane should be protected either through the use of temporary boarding over its whole area or the immediate laying of the concrete slab.

SOLCO

Rolls should be stored in dry conditions under cover, on their end. The temperature must be maintained at between 5° C and 30°C.

Solco, Unit 2, Stadium Indstrial Estate, Cradock Road, Luton, LU4 0JF

Solsheet Waterproof System Ancilliaries Solseal HP Emulsion/Primer is a quick drying liquid applied, low viscosity bitumen solution used to prime and seal porous substrates and promotes the adhesion of bituminous waterproofingsystemspriortoapplicationofSolsheet Membranes. Solco HD Bitumen Protection Board is a tough, reinforced flexiblebitumen modifiedboardfortheprotectionofadhesivewaterproo fingmembraneand other types of waterproofingmembranesagainstdamagebyabrasiveback fill materials and poured concrete Solco Protection Fleece (SP30) is intended to be used as a protection and/or seperation layer against mechanical or chemical damage, and is used between the waterproofi ng membrane & overlying components

Technical Data Packaging

5, 25 & 205 Litres

Coverage

10m2/L

Technical Data Sheet Size

1.0m x 2.0m

Thickness

3mm / 6mm

Weight

8kg / 16kg

Technical Data Roll Size

2m x 50m

Solco XL Jointing / Reinforcing Tape is a self adhesive tape is used as reinforcing / over-banding tape for securing waterproofingmembranesat overlaps edge and corner details and is available as standard or as a Gas Resistant XL Tape.

Roll Width(s)

Solco Butyl Tape is a black double sided synthetic rubber based high performance butyl mastic tape. It can be used for bonding waterproofingand gas protection membranes at overlaps and for bonding membranes to DPCs, and fixingofotheraccessoriessuchastophats

Roll Width

50 / 100mm

Roll Length

10m

Technical Data 10m

Thickness

1.5mm

Technical Data

SOLSHEET - Waterproofing Systems

Typical Slab Edge Detail (Suspended) Standard Construction

100 / 150 / 300mm

Roll Length

Last Issue Date: 01.01.19 Rev 3

Typical Slab Edge Detail (Ground Bearing) Standard Construction

Please contact our Technical department for project specific application details

Technical Support: 0808 168 6927

www.solco.co.uk

[email protected]