QUESTIONNAIRE REDREN

Sl. No. 1.1 2.1 3.1 4.1 5.01 5.02 5.03 5.04 6.01 6.02 6.03 6.04 6.05 6.06 6.07 6.08 6.09 6.10 7.01 7.02 7.03 7.04 7.05 7...

1 downloads 218 Views 472KB Size
Sl. No. 1.1 2.1 3.1 4.1 5.01 5.02 5.03 5.04 6.01 6.02 6.03 6.04 6.05 6.06 6.07 6.08 6.09 6.10 7.01 7.02 7.03 7.04 7.05 7.06 8.01 8.02 8.03 8.04 8.05 8.06 8.07 8.08 8.09 8.1 8.11 8.12 9.01

Questionnaire 100 LPD Solar Water Heating System with heat exchanger Type 1 for cold region Questionnaire REDREN Specification Name of the solar Water Heating system REDREN ENERGY PVT. LTD. manufacturer Model Number REDSOL FPC Rated capacity in liters per day (LPD) 100 Name of the solar flat plate collector a)Model REDREN Solar Flat Plate Collector No............ Size of solar Flat Plate collector (area in 2.31 sq.m).......... Length x width x thickness.....x.....x......cm 203.6X113.5X9 CM Dry weight in kgm 39 No. of collectors 1 Collector Box frame Aluminum Section Material….. Aluminum Sections used & their sizes.... Length wise 2 Section - each of 2030 mm And width wise 2 Section each of 1135 mm Thickness of supporting (bottom) sheet.....mm. 0.45 mm Insulation material Density of insulating material Thickness of insulating material....mm Side insulation thickness....mm Front Glazing of toughened glass thickness....mm

Fiberglass 32kg / Meter Cube 50 mm 25 mm 4mm

Material of gasket grommets & steel..... Absorber Area of absorber sheet in sq.m. Material.... Grade of material Thickness....mm (min.) No of absorber sheets per collector... Riser tubes Material Grade of material.... Tube length...mm Tube diameter....mm Tube thickness.........mm No. of riser tubes....... Space between riser tubes........mm (pitch) Coating material on tubes...... Header material Dia of header Thickness.......mm HOT WATER STORAGE TANK

EPDM Rubber Copper-Copper 2.1 Copper Copper 0.10 mm 9 Fin Tube Type Copper Copper 1920 mm 12.5 mm 0.56 mm 9 120 mm Solar Selective Nalson Coating Copper 25.4 0.71 mm Cold Rolled Steel

9.02 9.03 9.04 9.05 9.06 9.07 9.08 9.09 9.1 9.11 9.12 9.13 9.14 9.15 9.16 9.17 9.18 9.19 10.01 10.02 10.03 10.04 10.05 11.01 11.02 11.03 11.04 11.05 12.01 12.02 12.03 12.04 12.05 12.06 13.1 14.1 15.01 15.02 15.03 15.04 15.05 16.01 16.02 16.03 16.04

Material.......mention Grade Welding material.... Side Dished ends..... Insulation material Density of insulating material Thickness of insulating material Type of tank (Horizontal or vertical) Thickness of shell (mm) Thickness at the top....mm Thickness at the bottom....mm Tank cladding material Side (ends) cladding material Side (ends) cladding material thickness Side (ends) cladding finish Test Pressure Stand Assembly Size of Ms angle Finish System interconnecting piping GI pipe size-------------------mm. Class as per IS:1239 Insulation material, density and thickness Thickness of aluminum cladding Heat Exchanger Type Material and Grade of Tubes Thickness of Tubes Material of header & thickness Water Meter Size.------------------Make------------------Model-----------------ISI marked---------------Yes/No End connection------------------Size, Make, Model and end connections for sacrificial anode to prevent galvanic corrosion Capacity and material of the make up tank Valves No. of valves Make of valves Size of each valve Type of each valves Electrical Back-up Rating of heater ----------------Make---------------------Model---------------------

Low Carbon CRCA 6013 welding road Low Carbon CRCA PUF 32 kg/m3 50 mm Horizontal 2.5 mm 2.5 mm 2.5 mm GI with Powder Coating GI with Powder Coating 0.45 mm Dish type special shape 1 Kg/Sq. Cm. Tubular Structure with Powder Coating Tubular Structure made from 2.5 MM GI Sheet Pure Polyester Powder Coating GI Pipes / EPDM hose 25.4 mm Medium Class 'B' Fiberglass wool with 32 Kg/m3 0.45 mm CRCA Jacket Type Not Applicable Jacket Thickness 2 mm. NA Not Provided NA NA NA NA NA 300 mm Long, 20 mm dia, with 3/4" connection 5 Liter made from CRCA Low cabon steel Ball Two GM 25.4 mm Ball with handleType Yes 2 kw Schott Schott

16.05 17.01 17.02 17.03 17.04 17.05 18.01 18.02 18.03 18.04 18.05

End connection------------Strainer Size----------------Type----------------Material------------------End connection----------------Gauges Temp. Gauge (ISI marked)-------------Yes/No. Type---------------Dial Range.--------------------degree C to-----------------

1.25" BSP No NA NA NA NA NA No NA 0 to 120 Degree C

Any other gauge provided-----------------------------

No

Whether the system confirms to compliance with Yes 19.1 Household Electrical appliance (Quality control, order, 1981of Ministry of Industry. List of authorized service centers throughout the Enclosed country with complete address, telephone 20.1 number, fax and email address etc. (please enclose a list)

Sl. No. 1.1 2.1 3.1 4.1 5.01 5.02 5.03 5.04 6.01 6.02 6.03 6.04 6.05 6.06 6.07 6.08 6.09

200 LPD Solar Water Heating System with heat exchanger Type 1 for cold region Questionnaire REDREN Specification Name of the solar Water Heating system REDREN ENERGY PVT. LTD. manufacturer Model Number REDSOL FPC Rated capacity in litres per day (LPD) 200 Name of the solar flat plate collector a)Model REDREN Solar Flat Plate Collector No............ Size of solar Flat Plate collector (area in 2.31 sq.m).......... Length x width x thickness.....x.....x......cm 203.6X113.5X9 CM Dry weight in kgm 37 No. of collectors 2 Collector Box frame Aluminium Section Material….. Aluminium Sections used & their sizes.... Length wise 2 Section - each of 2030 mm And width wise 2 Section each of 1135 mm Thickness of supporting (bottom) sheet.....mm. 0.45 mm Insulation material Density of insulating material Thickness of insulating material....mm Side insulation thickness....mm Front Glazing of toughened glass thickness....mm

Fiberglass 32kg / Meter Cube 50 mm 25 mm 4mm

6.10 7.01 7.02 7.03 7.04 7.05 7.06 8.01 8.02 8.03 8.04 8.05 8.06 8.07 8.08 8.09 8.1 8.11 8.12 9.01 9.02 9.03 9.04 9.05 9.06 9.07 9.08 9.09 9.1 9.11 9.12 9.13 9.14 9.15 9.16 9.17 9.18 9.19 10.01 10.02 10.03 10.04 10.05 11.01 11.02 11.03

Material of gasket grommets & steel..... Absorber Area of absorber sheet in sq.m. Material.... Grade of material Thickness....mm (min.) No of absorber sheets per collector... Riser tubes Material Grade of material.... Tube length...mm Tube diameter....mm Tube thickness.........mm No. of riser tubes....... Space between riser tubes........mm (pitch) Coating material on tubes...... Header material Dia of header Thickness.......mm HOT WATER STORAGE TANK Material.......mention Grade Welding material.... Side Dished ends..... Insulation material Density of insulating material Thickness of insulating material Type of tank (Horizontal or vertical) Thickness of shell (mm) Thickness at the top....mm Thickness at the bottom....mm Tank cladding material Side (ends) cladding material Side (ends) cladding material thickness Side (ends) cladding finish Test Pressure Stand Assembly Size of Ms angle

EPDM Rubber Copper-Copper 2.1 Copper Copper 0.10 mm 9 Fin Tube Type Copper Copper 1920 mm 12.5 mm 0.56 mm 9 120 mm Solar Selective Nalson Coating Copper 25.4 0.71 mm Cold Rolled Steel Low Carbon CRCA 6013 welding road Low Carbon CRCA PUF 32 kg/m3 50 mm Horizontal 2.5 mm 2.5 mm 2.5 mm GI with Powder Coating GI with Powder Coating 0.45 mm Dish type special shape 1 Kg/Sq. Cm. Tubular Strucutre with Powder Coating Tubular Structure made from 2.5 MM GI Sheet

Finish System interconnecting pipeing GI pipe size-------------------mm. Class as per IS:1239 Insulation material, density and thickness Thickness of aluminium cladding Heat Exchanger Type Material and Grade of Tubes

Pure Polyester Powder Coating GI Pipes / EPDM hose 25.4 mm Mideum Class 'B' Fiberglass wool with 32 Kg/m3 0.45 mm CRCA Jacket Type Not Applicable

11.04 11.05 12.01 12.02 12.03 12.04 12.05 12.06

Thickness of Tubes Material of header & thickness Water Meter Size.------------------Make------------------Model-----------------ISI marked---------------Yes/No End connection------------------Size, Make, Model and end connections for 13.1 sacrificial anode to prevent galvanic corrosion

Jacket Thickness 2 mm. NA Not Provided NA NA NA NA NA 300 mm Long, 20 mm dia, with 3/4" connection

14.1 15.01 15.02 15.03 15.04 15.05 16.01 16.02 16.03 16.04 16.05 17.01 17.02 17.03 17.04 17.05 18.01 18.02 18.03

Capacity and material of the make up tank Valves No. of valves Make of valves Size of each valve Type of each valves Electrical Back-up Rating of heater ----------------Make---------------------Model--------------------End connecion------------Strainer Size----------------Type----------------Material------------------End connection----------------Gauges Temp. Gauge (ISI marked)-------------Yes/No. Type---------------Dial Range.--------------------degree C to-----------------

5 Liter made from CRCA Low cabon steel Ball Two GM 25.4 mm Ball with handleType Yes 3 kw Schott Schott 1.25" BSP No NA NA NA NA NA No NA NA

Any other gauge provided-----------------------------

No

18.04 18.05

Whether the system confirms to compliance with Yes 19.1 Household Electricalappliance (Quality control, order, 1981of Ministry of Industry. List of authorised service centres throughout the Enclosed country with complete address, telephone 20.1 number, fax and email address etc. (please enclose a list)

300 LPD Solar Water Heating System with heat exchanger Type 1 for cold region Sl. No. Questionnaire REDREN Specification Name of the solar Water Heating system REDREN ENERGY PVT. LTD. 1.1 manufacturer

2.1 3.1 4.1 5.01 5.02 5.03 5.04 6.01 6.02 6.03 6.04 6.05 6.06 6.07 6.08 6.09 6.10 7.01 7.02 7.03 7.04 7.05 7.06 8.01 8.02 8.03 8.04 8.05 8.06 8.07 8.08 8.09 8.1 8.11 8.12 9.01 9.02 9.03 9.04 9.05 9.06 9.07

Model Number Rated capacity in liters per day (LPD) Name of the solar flat plate collector a)Model No............ Size of solar Flat Plate collector (area in sq.m).......... Length x width x thickness.....x.....x......cm Dry weight in kgm No. of collectors Collector Box frame Material….. Sections used & their sizes....

REDSOL FPC 300 LPD REDREN Solar Flat Plate Collector 2.31

Thickness of supporting (bottom) sheet.....mm.

203.6X113.5X9 CM 39 3 Aluminum Section Aluminum Length wise 2 Section - each of 2030 mm And width wise 2 Section each of 1135 mm 0.45 mm

Insulation material Density of insulating material Thickness of insulating material....mm Side insulation thickness....mm Front Glazing of toughened glass thickness....mm

Fiberglass 32kg / Meter Cube 50 mm 25 mm 4mm

Material of gasket grommets & steel..... Absorber Area of absorber sheet in sq.m. Material.... Grade of material Thickness....mm (min.) No of absorber sheets per collector... Riser tubes Material Grade of material.... Tube length...mm Tube diameter....mm Tube thickness.........mm No. of riser tubes....... Space between riser tubes........mm (pitch) Coating material on tubes...... Header material Dia of header Thickness.......mm HOT WATER STORAGE TANK Material.......mention Grade Welding material.... Side Dished ends..... Insulation material Density of insulating material Thickness of insulating material

EPDM Rubber Copper-Copper 2.1 Copper Copper 0.10 mm 9 Fin Tube Type Copper Copper 1920 mm 12.5 mm 0.56 mm 9 120 mm Solar Selective Nalson Coating Copper 25.4 0.71 mm Cold Rolled Steel Low Carbon CRCA 6013 welding road Low Carbon CRCA PUF 32 kg/m3 50 mm

9.08 9.09 9.1 9.11 9.12 9.13 9.14 9.15 9.16 9.17

Type of tank (Horizontal or vertical) Thickness of shell (mm) Thickness at the top....mm Thickness at the bottom....mm Tank cladding material Side (ends) cladding material Side (ends) cladding material thickness Side (ends) cladding finish Test Pressure Stand Assembly Size of Ms angle

Horizontal 2.5 mm 2.5 mm 2.5 mm GI with Powder Coating GI with Powder Coating 0.45 mm Dish type special shape 1 Kg/Sq. Cm. Tubular Structure with Powder Coating Tubular Structure made from 2.5 MM GI Sheet

Finish System interconnecting piping GI pipe size-------------------mm. Class as per IS:1239 Insulation material, density and thickness Thickness of aluminum cladding Heat Exchanger Type Material and Grade of Tubes Thickness of Tubes Material of header & thickness Water Meter Size.------------------Make------------------Model-----------------ISI marked---------------Yes/No End connection------------------Size, Make, Model and end connections for 13.1 sacrificial anode to prevent galvanic corrosion

Pure Polyester Powder Coating GI Pipes / EPDM hose 25.4 mm Medium Class 'B' Fiberglass wool with 32 Kg/m3 0.45 mm CRCA Jacket Type Not Applicable Jacket Thickness 2 mm. NA Not Provided NA NA NA NA NA 300 mm Long, 20 mm dia, with 3/4" connection

14.1 15.01 15.02 15.03 15.04 15.05 16.01 16.02 16.03 16.04 16.05 17.01 17.02 17.03 17.04

5 Liter made from CRCA Low cabon steel Ball Two GM 25.4 mm Ball with handleType Yes 2 kw x 02 nos. Schott Schott 1.25" BSP No NA NA NA

9.18 9.19 10.01 10.02 10.03 10.04 10.05 11.01 11.02 11.03 11.04 11.05 12.01 12.02 12.03 12.04 12.05 12.06

Capacity and material of the make up tank Valves No. of valves Make of valves Size of each valve Type of each valves Electrical Back-up Rating of heater ----------------Make---------------------Model--------------------End connection------------Strainer Size----------------Type----------------Material-------------------

17.05 18.01 18.02 18.03 18.04 18.05

End connection----------------Gauges Temp. Gauge (ISI marked)-------------Yes/No. Type---------------Dial Range.--------------------degree C to-----------------

NA NA No NA NA

Any other gauge provided-----------------------------

No

Whether the system confirms to compliance with Yes 19.1 Household Electrical appliance (Quality control, order, 1981of Ministry of Industry. List of authorized service centers throughout the Enclosed country with complete address, telephone 20.1 number, fax and email address etc. (please enclose a list)

Sl. No. 1.1 2.1 3.1 4.1 5.01 5.02 5.03 5.04 6.01 6.02 6.03 6.04 6.05 6.06 6.07 6.08 6.09 6.10 7.01 7.02 7.03 7.04

500 LPD Solar Water Heating System with heat exchanger Type 1 for cold region Questionnaire REDREN Specification Name of the solar Water Heating system REDREN ENERGY PVT. LTD. manufacturer Model Number REDSOL FPC Rated capacity in liters per day (LPD) 500 LPD Name of the solar flat plate collector a)Model REDREN Solar Flat Plate Collector No............ Size of solar Flat Plate collector (area in 2.31 sq.m).......... Length x width x thickness.....x.....x......cm 203.6X113.5X9 CM Dry weight in kgm 39 No. of collectors 5 Collector Box frame Aluminum Section Material….. Aluminum Sections used & their sizes.... Length wise 2 Section - each of 2030 mm And width wise 2 Section each of 1135 mm Thickness of supporting (bottom) sheet.....mm. 0.45 mm Insulation material Density of insulating material Thickness of insulating material....mm Side insulation thickness....mm Front Glazing of toughened glass thickness....mm

Fiberglass 32kg / Meter Cube 50 mm 25 mm 4mm

Material of gasket grommets & steel..... Absorber Area of absorber sheet in sq.m. Material.... Grade of material

EPDM Rubber Copper-Copper 2.1 Copper Copper

7.05 7.06 8.01 8.02 8.03 8.04 8.05 8.06 8.07 8.08 8.09 8.1 8.11 8.12 9.01 9.02 9.03 9.04 9.05 9.06 9.07 9.08 9.09 9.1 9.11 9.12 9.13 9.14 9.15 9.16 9.17 9.18 9.19 10.01 10.02 10.03 10.04 10.05 11.01 11.02 11.03 11.04 11.05 12.01 12.02 12.03

Thickness....mm (min.) No of absorber sheets per collector... Riser tubes Material Grade of material.... Tube length...mm Tube diameter....mm Tube thickness.........mm No. of riser tubes....... Space between riser tubes........mm (pitch) Coating material on tubes...... Header material Dia of header Thickness.......mm HOT WATER STORAGE TANK Material.......mention Grade Welding material.... Side Dished ends..... Insulation material Density of insulating material Thickness of insulating material Type of tank (Horizontal or vertical) Thickness of shell (mm) Thickness at the top....mm Thickness at the bottom....mm Tank cladding material Side (ends) cladding material Side (ends) cladding material thickness Side (ends) cladding finish Test Pressure Stand Assembly Size of Ms angle

0.10 mm 9 Fin Tube Type Copper Copper 1920 mm 12.5 mm 0.56 mm 9 120 mm Solar Selective Nalson Coating Copper 25.4 0.71 mm Cold Rolled Steel Low Carbon CRCA 6013 welding road Low Carbon CRCA PUF 32 kg/m3 50 mm Horizontal 2.5 mm 2.5 mm 2.5 mm GI with Powder Coating GI with Powder Coating 0.45 mm Dish type special shape 1 Kg/Sq. Cm. Tubular Structure with Powder Coating Tubular Structure made from 2.5 MM GI Sheet

Finish System interconnecting piping GI pipe size-------------------mm. Class as per IS:1239 Insulation material, density and thickness Thickness of aluminum cladding Heat Exchanger Type Material and Grade of Tubes Thickness of Tubes Material of header & thickness Water Meter Size.------------------Make-------------------

Pure Polyester Powder Coating GI Pipes / EPDM hose 25.4 mm Medium Class 'B' Fiberglass wool with 32 Kg/m3 0.45 mm CRCA Jacket Type Not Applicable Jacket Thickness 2 mm. NA Not Provided NA NA

12.04 Model-----------------12.05 ISI marked---------------Yes/No 12.06 End connection------------------Size, Make, Model and end connections for 13.1 sacrificial anode to prevent galvanic corrosion

NA NA NA 300 mm Long, 20 mm dia, with 3/4" connection

14.1 15.01 15.02 15.03 15.04 15.05 16.01 16.02 16.03 16.04 16.05 17.01 17.02 17.03 17.04 17.05 18.01 18.02 18.03

Capacity and material of the make up tank Valves No. of valves Make of valves Size of each valve Type of each valves Electrical Back-up Rating of heater ----------------Make---------------------Model--------------------End connection------------Strainer Size----------------Type----------------Material------------------End connection----------------Gauges Temp. Gauge (ISI marked)-------------Yes/No. Type---------------Dial Range.--------------------degree C to-----------------

5 Liter made from CRCA Low cabon steel Ball Two GM 25.4 mm Ball with handleType Yes 3 kw x 02 nos. Schott Schott 1.25" BSP No NA NA NA NA NA No NA NA

Any other gauge provided-----------------------------

No

18.04 18.05

Whether the system confirms to compliance with Yes 19.1 Household Electrical appliance (Quality control, order, 1981of Ministry of Industry. List of authorized service centers throughout the Enclosed country with complete address, telephone 20.1 number, fax and email address etc. (please enclose a list)

Sl. No. 1.1 2.1 3.1 4.1

1000 LPD Solar Water Heating System with heat exchanger Type 1 for cold region Questionnaire REDREN Specification Name of the solar Water Heating system REDREN ENERGY PVT. LTD. manufacturer Model Number REDSOL FPC Rated capacity in liters per day (LPD) 1000 LPD Name of the solar flat plate collector a)Model REDREN Solar Flat Plate Collector No............

5.01 5.02 5.03 5.04 6.01 6.02 6.03 6.04 6.05 6.06 6.07 6.08 6.09 6.10 7.01 7.02 7.03 7.04 7.05 7.06 8.01 8.02 8.03 8.04 8.05 8.06 8.07 8.08 8.09 8.1 8.11 8.12 9.01 9.02 9.03 9.04 9.05 9.06 9.07 9.08 9.09 9.1 9.11

Size of solar Flat Plate collector (area in sq.m).......... Length x width x thickness.....x.....x......cm Dry weight in kgm No. of collectors Collector Box frame Material….. Sections used & their sizes....

2.31

Thickness of supporting (bottom) sheet.....mm.

203.6X113.5X9 CM 39 9 Aluminum Section Aluminum Length wise 2 Section - each of 2030 mm And width wise 2 Section each of 1135 mm 0.45 mm

Insulation material Density of insulating material Thickness of insulating material....mm Side insulation thickness....mm Front Glazing of toughened glass thickness....mm

Rockwool 48 kg / Meter Cube 50 mm 25 mm 4mm

Material of gasket grommets & steel..... Absorber Area of absorber sheet in sq.m. Material.... Grade of material Thickness....mm (min.) No of absorber sheets per collector... Riser tubes Material Grade of material.... Tube length...mm Tube diameter....mm Tube thickness.........mm No. of riser tubes....... Space between riser tubes........mm (pitch) Coating material on tubes...... Header material Dia of header Thickness.......mm HOT WATER STORAGE TANK Material.......mention Grade Welding material.... Side Dished ends..... Insulation material Density of insulating material Thickness of insulating material Type of tank (Horizontal or vertical) Thickness of shell (mm) Thickness at the top....mm Thickness at the bottom....mm

EPDM Rubber Copper-Copper 2.1 Copper Copper 0.10 mm 9 Fin Tube Type 9 nos. Copper Copper 1920 mm 12.5 mm 0.56 mm 9 120 mm Solar Selective Nalson Coating Copper 25.4 0.71 mm Cold Rolled Steel Low Carbon CRCA 6013 welding road Low Carbon CRCA PUF / Rockwool 32 kg/m3 or 48 kg/m3 50 mm for PUF & 100 mm For Rockwool Horizontal 2.5 mm 2.5 mm 2.5 mm

9.12 Tank cladding material 9.13 Side (ends) cladding material Side (ends) cladding material thickness 9.14

AL 22 SWG OR GI with Powder Coating AL 22 SWG OR GI with Powder Coating AL 22 SWG OR 0.45 mm GI with Powder Coating

9.15 Side (ends) cladding finish 9.16 Test Pressure 9.17 Stand Assembly Size of Ms angle 9.18

Dish type special shape 1 Kg/Sq. Cm. Tubular Structure with Powder Coating Tubular Structure made from 2.5 MM GI Sheet

9.19 10.01 10.02 10.03 10.04 10.05 11.01 11.02 11.03 11.04 11.05 12.01 12.02 12.03 12.04 12.05 12.06

Finish System interconnecting piping GI pipe size-------------------mm. Class as per IS:1239 Insulation material, density and thickness Thickness of aluminum cladding Heat Exchanger Type Material and Grade of Tubes Thickness of Tubes Material of header & thickness Water Meter Size.------------------Make------------------Model-----------------ISI marked---------------Yes/No End connection------------------Size, Make, Model and end connections for 13.1 sacrificial anode to prevent galvanic corrosion

Pure Polyester Powder Coating GI Pipes / EPDM hose 25.4 mm Medium Class 'B' Rock wool with 48 Kg/m3 0.45 mm CRCA Jacket Type Not Applicable Jacket Thickness 2 mm. NA Not Provided NA NA NA NA NA Not Provided

14.1 15.01 15.02 15.03 15.04 15.05 16.01 16.02 16.03 16.04 16.05 17.01 17.02 17.03 17.04 17.05 18.01 18.02

10 Liter made from CRCA Low cabon steel Ball Two GM 25.4 mm Ball with handleType Yes 3 kw x 03 nos. Schott Schott 1.25" BSP No NA NA NA NA NA No

Capacity and material of the make up tank Valves No. of valves Make of valves Size of each valve Type of each valves Electrical Back-up Rating of heater ----------------Make---------------------Model--------------------End connection------------Strainer Size----------------Type----------------Material------------------End connection----------------Gauges Temp. Gauge (ISI marked)-------------Yes/No.

18.03 Type---------------Dial Range.--------------------degree C to----------------18.04 18.05

Any other gauge provided-----------------------------

NA NA No

Whether the system confirms to compliance with Yes 19.1 Household Electrical appliance (Quality control, order, 1981of Ministry of Industry. List of authorized service centers throughout the Enclosed country with complete address, telephone 20.1 number, fax and email address etc. (please enclose a list)