Item Description Item No. 1 Diesel Generating Sets M/s Electro Equipments Guaranteed Technical Particulars (GTP) of DG Furnished Below Sets (To be furnished by tenderers for each quoted item separately) Name of DG Set Manufacturer Electro Equipments Model number SEKG5AS7 Rated power output and duty cycle 3.5 KVA, CONTINUOUS Rated voltage, current, power factor and 240V, 14.58A, 0.8PF, 50HZ frequency Voltage regulation VG-1 or Better GRADE UPTO 82.5KVA AND VG-3 GRADE ABOVE 82.5 KVA Maximum temperature rise above ambient AS PER INSULATION (for engine) Class of insulation H or BETTER Efficiency of the alternator AS PER MANUFACTURER TYPE TEST CERTIFICATE Speed of revolution (RPM) at no load and 1500 RPM + 4.5% rated voltage Type of excitation and excitation voltage SELF EXCITED Ambient conditions for which the DG set is AS PER IS STANDARD suitable Type of enclosure SPDP Type of loads for which the genset is suitable 0.8 POWER FACTOR (LAG) Maximum load that can be switched on or off and voltage drop/rise permitted Engine model number & manufacturer Type of cooling Fuel tank capacity (it shall be suitable for 12 hours minimum at rated load and at continuous operation) Total fuel consumption in liters/KWh Rated engine power and the ambient conditions at which rated power is defined

FULL LOAD, AS PER IS STANDARD EA10 / KIRLOSKAR AIR COOLED SUITABLE FOR MINIMUM12 HRS.

AS PER MANUFACTURER 10 BHP, AT STANDARD CONDITIONS

2.07

Other standard fittings of the engine to be AS PER MANUFACTURER specified by the tenderers Specific fuel consumption (in gms/kwh) 230 gms/kw-hr/ AS PER IS 10000

3.01

Dry weight of the DG Set with canopy

650 kg Approx

4

Maximum continuous operating time at rated load Peak power output and the duration for which the DG set can deliver this output

AS PER RELAVENT IS STANDARD AS APPLICABLE 10% OVERLOAD FOR 1 HR FOR EVERY 11HRS CONTINUOUS RUNNING AT RATED LOAD.

6

Manual control panel with composite digital display meter, make, class & range for measurement of voltage, current, pf, frequency, kwh.

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKECONZERVE/SECURE/AE/L&T/INDOTECH/ HPL/ NIPPEN/ AS PER DGS&D NORMS

7

Microprocessor based AMF control panel with composite digital display meter, make, class & range for measurement of voltage,current, pf, frequency, kwh.

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKEUTOPIA/KIRLOSKAR/AS PER DGS&D NORMS

8

Submission of valid and renewed COP Attached certificate of DG Set from an authorized certification agency.

9

Submission of valid and renewed TAC CONFIRMED certificate of DG set from an authorized certification agency.

10

Vibration level maximum

AS PER IS:8528-9

11

Type of coupling and mounting details

CLOSED COUPLED OR DIAPHRAGM COUPLING AS PER ENGINE MANUFACTURE STANDARD

12

Deviation in the generator specification from IS specification, if any. Confirmation regarding submission of copy of type approval certificate form an authorized agency for emission norms for each model of engine quoted to D(QA) at the time of inspection.

5

13

NIL CONFIRMED

14

Valid BIS license no.,rating & date of validity for engine.

Attached

15

Valid BIS license no.,rating & date of validity for alternator.

Attached

16

Confirmation regarding COP certificate of DG Sets from an authorized agency for emission norms for each model of engine quoted, to D(QA) at the time of inspection.

CONFIRMED

17

Make/Model/RPM of alternator

TRIDENT-BRAND KIRLOSKAR GREENKG164G/DGS&D TYPE TESTED/1500

QUESTIONNAIRE DIESEL GENERATING SET WITH AMF CONTROL PANEL: S.no 1 1.01

1.02 1.03 1.04 1.05 1.06 1.07 1.08 1.09 1.1 1.11 1.12 1.13 1.14 1.15 2.01 2.02 2.03

2.04 2.05

2.06

Item Description Item No. 2 Diesel Generating Sets M/s Electro Equipments Guaranteed Technical Particulars (GTP) of DG Furnished Below Sets (To be furnished by tenderers for each quoted item separately) Name of DG Set Manufacturer Electro Equipments Model number SEKG5AS7 Rated power output and duty cycle 5 KVA, CONTINUOUS Rated voltage, current, power factor and 240V, 20.8A, 0.8PF, 50HZ frequency Voltage regulation VG-1 or Better GRADE UPTO 82.5KVA AND VG-3 GRADE ABOVE 82.5 KVA Maximum temperature rise above ambient AS PER INSULATION (for engine) Class of insulation H or BETTER Efficiency of the alternator AS PER MANUFACTURER TYPE TEST CERTIFICATE Speed of revolution (RPM) at no load and 1500 RPM+4.5% rated voltage Type of excitation and excitation voltage SELF EXCITED Ambient conditions for which the DG set is AS PER IS suitable Type of enclosure SPDP Type of loads for which the genset is suitable 0.8 POWER FACTOR (LAG) Maximum load that can be switched on or off and voltage drop/rise permitted Engine model number & manufacturer Type of cooling Fuel tank capacity (it shall be suitable for 12 hours minimum at rated load and at continuous operation) Total fuel consumption in liters/KWh Rated engine power and the ambient conditions at which rated power is defined

FULL LOAD, AS PER IS 10000 EA10 / KIRLOSKAR AIR COOLED SUITABLE FOR MINIMUM12 HRS.

AS PER MANUFACTURER 10 BHP, AT STANDARD CONDITIONS

2.07

Other standard fittings of the engine to be AS PER MANUFACTURER specified by the tenderers Specific fuel consumption (in gms/kwh) 230 gms/kw-hr/ AS PER IS STANDARD

3.01

Dry weight of the DG Set with canopy

650 kg Approx

4

Maximum continuous operating time at rated load Peak power output and the duration for which the DG set can deliver this output

AS PER RELAVENT IS/BS STANDARD AS APPLICABLE 10% OVERLOAD FOR 1 HR FOR EVERY 11HRS CONTINUOUS RUNNING AT RATED LOAD.

6

Manual control panel with composite digital display meter, make, class & range for measurement of voltage, current, pf, frequency, kwh.

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKECONZERVE/SECURE/AE/L&T/INDOTECH/ HPL/ NIPPEN/ AS PER DGS&D NORMS

7

Microprocessor based AMF control panel with composite digital display meter, make, class & range for measurement of voltage,current, pf, frequency, kwh.

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKEUTOPIA/KIRLOSKAR/AS PER DGS&D NORMS

8

Submission of valid and renewed COP Attached certificate of DG Set from an authorized certification agency.

9

Submission of valid and renewed TAC CONFIRMED certificate of DG set from an authorized certification agency.

10

Vibration level maximum

AS PER IS:8528-9

11

Type of coupling and mounting details

CLOSED COUPLED OR DIAPHRAGM COUPLING AS PER ENGINE MANUFACTURE STANDARD

12

Deviation in the generator specification from IS specification, if any. Confirmation regarding submission of copy of type approval certificate form an authorized agency for emission norms for each model of engine quoted to D(QA) at the time of inspection.

5

13

NIL CONFIRMED

14

Valid BIS license no.,rating & date of validity for engine.

Attached

15

Valid BIS license no.,rating & date of validity for alternator.

Attached

16

Confirmation regarding COP certificate of DG Sets from an authorized agency for emission norms for each model of engine quoted, to D(QA) at the time of inspection.

CONFIRMED

17

Make/Model/RPM of alternator

TRIDENT-BRAND KIRLOSKAR GREENKG164G/DGS&D TYPE TESTED/1500

QUESTIONNAIRE DIESEL GENERATING SET WITH AMF CONTROL PANEL: S.no 1 1.01

1.02 1.03 1.04 1.05 1.06 1.07 1.08 1.09 1.1 1.11 1.12 1.13 1.14 1.15 2.01 2.02 2.03

2.04 2.05

2.06

Item Description Item No. 3 Diesel Generating Sets M/s Electro Equipments Guaranteed Technical Particulars (GTP) of DG Furnished Below Sets (To be furnished by tenderers for each quoted item separately) Name of DG Set Manufacturer Electro Equipments Model number SEKG7.5AS5 Rated power output and duty cycle 7.5 KVA, CONTINUOUS Rated voltage, current, power factor and 240V, 31.3A, 0.8PF, 50HZ frequency Voltage regulation VG-1 or Better GRADE UPTO 82.5KVA AND VG-3 GRADE ABOVE 82.5 KVA Maximum temperature rise above ambient AS PER INSULATION (for engine) Class of insulation H or BETTER Efficiency of the alternator AS PER MANUFACTURER TYPE TEST CERTIFICATE Speed of revolution (RPM) at no load and 1500 RPM+4.5% rated voltage Type of excitation and excitation voltage SELF EXCITED Ambient conditions for which the DG set is AS PER IS suitable Type of enclosure SPDP Type of loads for which the genset is suitable 0.8 POWER FACTOR (LAG) Maximum load that can be switched on or off and voltage drop/rise permitted Engine model number & manufacturer Type of cooling Fuel tank capacity (it shall be suitable for 12 hours minimum at rated load and at continuous operation) Total fuel consumption in liters/KWh Rated engine power and the ambient conditions at which rated power is defined

FULL LOAD, AS PER IS STANDARD EA16 / KIRLOSKAR AIR COOLED SUITABLE FOR MINIMUM 12 HRS.

AS PER MANUFACTURER 16 BHP, AT STANDARD CONDITIONS

2.07

Other standard fittings of the engine to be AS PER MANUFACTURER specified by the tenderers Specific fuel consumption (in gms/kwh) 235 gms/kw-hr/ AS PER IS 10000

3.01

Dry weight of the DG Set with canopy

850 kg approx

4

Maximum continuous operating time at rated load Peak power output and the duration for which the DG set can deliver this output

AS PER RELAVENT IS STANDARD AS APPLICABLE 10% OVERLOAD FOR 1 HR FOR EVERY 11HRS CONTINUOUS RUNNING AT RATED LOAD.

6

Manual control panel with composite digital display meter, make, class & range for measurement of voltage, current, pf, frequency, kwh.

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKECONZERVE/SECURE/AE/L&T/INDOTECH/ HPL/ NIPPEN/ AS PER DGS&D NORMS

7

Microprocessor based AMF control panel with composite digital display meter, make, class & range for measurement of voltage,current, pf, frequency, kwh.

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKEUTOPIA/KIRLOSKAR/AS PER DGS&D NORMS

8

Submission of valid and renewed COP Attached certificate of DG Set from an authorized certification agency.

9

Submission of valid and renewed TAC CONFIRMED certificate of DG set from an authorized certification agency.

10

Vibration level maximum

AS PER IS:8528-9

11

Type of coupling and mounting details

CLOSED COUPLED OR DIAPHRAGM COUPLING AS PER ENGINE MANUFACTURE STANDARD

12

Deviation in the generator specification from IS specification, if any. Confirmation regarding submission of copy of type approval certificate form an authorized agency for emission norms for each model of engine quoted to D(QA) at the time of inspection.

5

13

NIL CONFIRMED

14

Valid BIS license no.,rating & date of validity for engine.

Attached

15

Valid BIS license no.,rating & date of validity for alternator.

Attached

16

Confirmation regarding COP certificate of DG Sets from an authorized agency for emission norms for each model of engine quoted, to D(QA) at the time of inspection.

CONFIRMED

17

Make/Model/RPM of alternator

TRIDENT-BRAND KIRLOSKAR GREENKG164H/DGS&D TYPE TESTED/1500

QUESTIONNAIRE DIESEL GENERATING SET WITH AMF CONTROL PANEL: S.no 1 1.01

1.02 1.03 1.04 1.05 1.06 1.07 1.08 1.09 1.1 1.11 1.12 1.13 1.14 1.15 2.01 2.02 2.03

2.04 2.05

2.06

Item Description Item No. 4 Diesel Generating Sets M/s Electro Equipments Guaranteed Technical Particulars (GTP) of DG Furnished Below Sets (To be furnished by tenderers for each quoted item separately) Name of DG Set Manufacturer Electro Equipments Model number SEKG10AS5 Rated power output and duty cycle 10 KVA, CONTINUOUS Rated voltage, current, power factor and 240V, 41.7A, 0.8PF, 50HZ frequency Voltage regulation VG-1 or Better GRADE UPTO 82.5KVA AND VG-3 GRADE ABOVE 82.5 KVA Maximum temperature rise above ambient AS PER INSULATION (for engine) Class of insulation H or BETTER Efficiency of the alternator AS PER MANUFACTURER TYPE TEST CERTIFICATE Speed of revolution (RPM) at no load and 1500 RPM+ 4.5% rated voltage Type of excitation and excitation voltage SELF EXCITED Ambient conditions for which the DG set is AS PER IS suitable Type of enclosure SPDP Type of loads for which the genset is suitable 0.8 POWER FACTOR (LAG) Maximum load that can be switched on or off and voltage drop/rise permitted Engine model number & manufacturer Type of cooling Fuel tank capacity (it shall be suitable for 12 hours minimum at rated load and at continuous operation) Total fuel consumption in liters/KWh Rated engine power and the ambient conditions at which rated power is defined

FULL LOAD, AS PER IS STANDARD EA16 / KIRLOSKAR AIR COOLED SUITABLE FOR MINIMUM 12 HRS.

AS PER MANUFACTURER 16 BHP, AT STANDARD CONDITIONS

2.07

Other standard fittings of the engine to be AS PER MANUFACTURER specified by the tenderers Specific fuel consumption (in gms/kwh) 235 gms/kw-hr/ AS PER IS 10000

3.01

Dry weight of the DG Set with canopy

850 kg approx

4

Maximum continuous operating time at rated load Peak power output and the duration for which the DG set can deliver this output

AS PER RELAVENT IS STANDARD AS APPLICABLE 10% OVERLOAD FOR 1 HR FOR EVERY 11HRS CONTINUOUS RUNNING AT RATED LOAD.

6

Manual control panel with composite digital display meter, make, class & range for measurement of voltage, current, pf, frequency, kwh.

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKECONZERVE/SECURE/AE/L&T/INDOTECH/ HPL/ NIPPEN/ AS PER DGS&D NORMS

7

Microprocessor based AMF control panel with composite digital display meter, make, class & range for measurement of voltage,current, pf, frequency, kwh.

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKEUTOPIA/KIRLOSKAR/AS PER DGS&D NORMS

8

Submission of valid and renewed COP Attached certificate of DG Set from an authorized certification agency.

9

Submission of valid and renewed TAC CONFIRMED certificate of DG set from an authorized certification agency.

10

Vibration level maximum

AS PER IS:8528-9

11

Type of coupling and mounting details

CLOSED COUPLED OR DIAPHRAGM COUPLING AS PER ENGINE MANUFACTURE STANDARD

12

Deviation in the generator specification from IS specification, if any. Confirmation regarding submission of copy of type approval certificate form an authorized agency for emission norms for each model of engine quoted to D(QA) at the time of inspection.

5

13

NIL CONFIRMED

14

Valid BIS license no.,rating & date of validity for engine.

Attached

15

Valid BIS license no.,rating & date of validity for alternator.

Attached

16

Confirmation regarding COP certificate of DG Sets from an authorized agency for emission norms for each model of engine quoted, to D(QA) at the time of inspection.

CONFIRMED

17

Make/Model/RPM of alternator

TRIDENT-BRAND KIRLOSKAR GREENKG164J/DGS&D TYPE TESTED/1500

QUESTIONNAIRE DIESEL GENERATING SET WITH AMF CONTROL PANEL: S.no 1 1.01

1.02 1.03 1.04 1.05 1.06 1.07 1.08 1.09 1.1 1.11 1.12 1.13 1.14 1.15 2.01 2.02 2.03

2.04 2.05

2.06

Item Description Item No. 5 Diesel Generating Sets M/s Electro Equipments Guaranteed Technical Particulars (GTP) of DG Furnished Below Sets (To be furnished by tenderers for each quoted item separately) Name of DG Set Manufacturer Electro Equipments Model number KG15AS4 Rated power output and duty cycle 15 KVA, CONTINUOUS Rated voltage, current, power factor and 240V, 62.5A, 0.8PF, 50HZ frequency Voltage regulation VG-1 or Better GRADE UPTO 82.5KVA AND VG-3 GRADE ABOVE 82.5 KVA Maximum temperature rise above ambient AS PER INSULATION (for engine) Class of insulation H or BETTER Efficiency of the alternator AS PER MANUFACTURER TYPE TEST CERTIFICATE Speed of revolution (RPM) at no load and 1500 RPM+4.5% rated voltage Type of excitation and excitation voltage SELF EXCITED Ambient conditions for which the DG set is AS PER IS suitable Type of enclosure SPDP Type of loads for which the genset is suitable 0.8 POWER FACTOR (LAG) Maximum load that can be switched on or off and voltage drop/rise permitted Engine model number & manufacturer Type of cooling Fuel tank capacity (it shall be suitable for 12 hours minimum at rated load and at continuous operation) Total fuel consumption in liters/KWh Rated engine power and the ambient conditions at which rated power is defined

FULL LOAD, AS PER IS STANDARD HA294 SR III / KIRLOSKAR AIR COOLED SUITABLE FOR MINIMUM12 HRS.

AS PER MANUFACTURER 20.5 BHP, AT STANDARD CONDITIONS

2.07

Other standard fittings of the engine to be AS PER MANUFACTURER specified by the tenderers Specific fuel consumption (in gms/kwh) 242 GMS/KW-HR/AS PER IS 10000

3.01

Dry weight of the DG Set with canopy

900 KG APPROX

4

Maximum continuous operating time at rated load Peak power output and the duration for which the DG set can deliver this output

AS PER RELAVENT IS/BS STANDARD AS APPLICABLE 10% OVERLOAD FOR 1 HR FOR EVERY 11HRS CONTINUOUS RUNNING AT RATED LOAD.

6

Manual control panel with composite digital display meter, make, class & range for measurement of voltage, current, pf, frequency, kwh.

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKECONZERVE/SECURE/AE/L&T/INDOTECH/ HPL/ NIPPEN/ AS PER DGS&D NORMS

7

Microprocessor based AMF control panel with composite digital display meter, make, class & range for measurement of voltage,current, pf, frequency, kwh.

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKEUTOPIA/KIRLOSKAR/AS PER DGS&D NORMS

8

Submission of valid and renewed COP Attached certificate of DG Set from an authorized certification agency.

9

Submission of valid and renewed TAC CONFIRMED certificate of DG set from an authorized certification agency.

10

Vibration level maximum

AS PER IS:8528-9

11

Type of coupling and mounting details

CLOSED COUPLED OR DIAPHRAGM COUPLING AS PER ENGINE MANUFACTURE STANDARD

12

Deviation in the generator specification from IS specification, if any. Confirmation regarding submission of copy of type approval certificate form an authorized agency for emission norms for each model of engine quoted to D(QA) at the time of inspection.

5

13

NIL CONFIRMED

14

Valid BIS license no.,rating & date of validity for engine.

Attached

15

Valid BIS license no.,rating & date of validity for alternator.

Attached

16

Confirmation regarding COP certificate of DG Sets from an authorized agency for emission norms for each model of engine quoted, to D(QA) at the time of inspection.

CONFIRMED

17

Make/Model/RPM of alternator

TRIDENT-BRAND KIRLOSKAR GREENKG184B/DGS&D TYPE TESTED/1500

QUESTIONNAIRE DIESEL GENERATING SET WITH AMF CONTROL PANEL: S.no 1 1.01

1.02 1.03 1.04 1.05 1.06 1.07 1.08 1.09 1.1 1.11 1.12 1.13 1.14 1.15 2.01 2.02 2.03

2.04 2.05

2.06

Item Description Item No. 5A Diesel Generating Sets M/s Electro Equipments Guaranteed Technical Particulars (GTP) of DG Furnished Below Sets (To be furnished by tenderers for each quoted item separately) Name of DG Set Manufacturer Electro Equipments Model number SEKG15AS6 Rated power output and duty cycle 15 KVA, CONTINUOUS Rated voltage, current, power factor and 240V, 62.5A, 0.8PF, 50HZ frequency Voltage regulation VG-1 or Better GRADE UPTO 82.5KVA AND VG-3 GRADE ABOVE 82.5 KVA Maximum temperature rise above ambient AS PER INSULATION (for engine) Class of insulation H or BETTER Efficiency of the alternator AS PER MANUFACTURER TYPE TEST CERTIFICATE Speed of revolution (RPM) at no load and 1500 RPM+4.5% rated voltage Type of excitation and excitation voltage SELF EXCITED Ambient conditions for which the DG set is AS PER IS suitable Type of enclosure SPDP Type of loads for which the genset is suitable 0.8 POWER FACTOR (LAG) Maximum load that can be switched on or off and voltage drop/rise permitted Engine model number & manufacturer Type of cooling Fuel tank capacity (it shall be suitable for 12 hours minimum at rated load and at continuous operation) Total fuel consumption in liters/KWh Rated engine power and the ambient conditions at which rated power is defined

FULL LOAD, AS PER IS STANDARD EA20 / KIRLOSKAR AIR COOLED SUITABLE FOR MINIMUM12 HRS.

AS PER MANUFACTURER 20 BHP, AT STANDARD CONDITIONS

2.07

Other standard fittings of the engine to be AS PER MANUFACTURER specified by the tenderers Specific fuel consumption (in gms/kwh) 242 GMS/KW-HR/AS PER IS 10000

3.01

Dry weight of the DG Set with canopy

900 KG APPROX

4

Maximum continuous operating time at rated load Peak power output and the duration for which the DG set can deliver this output

AS PER RELAVENT IS/BS STANDARD AS APPLICABLE 10% OVERLOAD FOR 1 HR FOR EVERY 11HRS CONTINUOUS RUNNING AT RATED LOAD.

6

Manual control panel with composite digital display meter, make, class & range for measurement of voltage, current, pf, frequency, kwh.

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKECONZERVE/SECURE/AE/L&T/INDOTECH/ HPL/ NIPPEN/ AS PER DGS&D NORMS

7

Microprocessor based AMF control panel with composite digital display meter, make, class & range for measurement of voltage,current, pf, frequency, kwh.

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKEUTOPIA/KIRLOSKAR/AS PER DGS&D NORMS

8

Submission of valid and renewed COP Attached certificate of DG Set from an authorized certification agency.

9

Submission of valid and renewed TAC CONFIRMED certificate of DG set from an authorized certification agency.

10

Vibration level maximum

AS PER IS:8528-9

11

Type of coupling and mounting details

CLOSED COUPLED OR DIAPHRAGM COUPLING AS PER ENGINE MANUFACTURE STANDARD

12

Deviation in the generator specification from IS specification, if any. Confirmation regarding submission of copy of type approval certificate form an authorized agency for emission norms for each model of engine quoted to D(QA) at the time of inspection.

5

13

NIL CONFIRMED

14

Valid BIS license no.,rating & date of validity for engine.

Attached

15

Valid BIS license no.,rating & date of validity for alternator.

Attached

16

Confirmation regarding COP certificate of DG Sets from an authorized agency for emission norms for each model of engine quoted, to D(QA) at the time of inspection.

CONFIRMED

17

Make/Model/RPM of alternator

TRIDENT-BRAND KIRLOSKAR GREENKG164J/DGS&D TYPE TESTED/1500

QUESTIONNAIRE DIESEL GENERATING SET WITH AMF CONTROL PANEL: S.no 1 1.01

1.02 1.03 1.04 1.05 1.06 1.07 1.08 1.09 1.1 1.11 1.12 1.13 1.14 1.15 2.01 2.02 2.03

2.04 2.05

2.06

Item Description Item No. 6 Diesel Generating Sets M/s Electro Equipments Guaranteed Technical Particulars (GTP) of DG Furnished Below Sets (To be furnished by tenderers for each quoted item separately) Name of DG Set Manufacturer Electro Equipments Model number KG25AS-C Rated power output and duty cycle 20 KVA, CONTINUOUS Rated voltage, current, power factor and 240V, 83.3A, 0.8PF, 50HZ frequency Voltage regulation VG-1 or Better GRADE UPTO 82.5KVA AND VG-3 GRADE ABOVE 82.5 KVA Maximum temperature rise above ambient AS PER INSULATION (for engine) Class of insulation H or BETTER Efficiency of the alternator AS PER MANUFACTURER TYPE TEST CERTIFICATE Speed of revolution (RPM) at no load and 1500 RPM +4.5% rated voltage Type of excitation and excitation voltage SELF EXCITED Ambient conditions for which the DG set is AS PER IS suitable Type of enclosure SPDP Type of loads for which the genset is suitable 0.8 POWER FACTOR (LAG) Maximum load that can be switched on or off and voltage drop/rise permitted Engine model number & manufacturer Type of cooling Fuel tank capacity (it shall be suitable for 12 hours minimum at rated load and at continuous operation) Total fuel consumption in liters/KWh Rated engine power and the ambient conditions at which rated power is defined

FULL LOAD, AS PER IS STANDARD HA394/ KIRLOSKAR AIR COOLED SUITABLE FOR MINIMUM12 HRS.

AS PER MANUFACTURER 32 BHP, AT STANDARD CONDITIONS

2.07

Other standard fittings of the engine to be AS PER MANUFACTURER specified by the tenderers Specific fuel consumption (in gms/kwh) 174 GMS/HP-HR/AS PER IS 10000

3.01

Dry weight of the DG Set with canopy

1050 KG APPROX

4

Maximum continuous operating time at rated load Peak power output and the duration for which the DG set can deliver this output

AS PER RELAVENT IS/BS STANDARD AS APPLICABLE 10% OVERLOAD FOR 1 HR FOR EVERY 11HRS CONTINUOUS RUNNING AT RATED LOAD.

6

Manual control panel with composite digital display meter, make, class & range for measurement of voltage, current, pf, frequency, kwh.

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKECONZERVE/SECURE/AE/L&T/INDOTECH/ HPL/ NIPPEN/ AS PER DGS&D NORMS

7

Microprocessor based AMF control panel with composite digital display meter, make, class & range for measurement of voltage,current, pf, frequency, kwh.

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKEUTOPIA/KIRLOSKAR/AS PER DGS&D NORMS

8

Submission of valid and renewed COP ATTACHED certificate of DG Set from an authorized certification agency.

9

Submission of valid and renewed TAC CONFIRMED certificate of DG set from an authorized certification agency.

10

Vibration level maximum

AS PER IS:8528-9

11

Type of coupling and mounting details

CLOSED COUPLED OR DIAPHRAGM COUPLING AS PER ENGINE MANUFACTURE STANDARD

12

Deviation in the generator specification from IS specification, if any. Confirmation regarding submission of copy of type approval certificate form an authorized agency for emission norms for each model of engine quoted to D(QA) at the time of inspection.

5

13

NIL CONFIRMED

14

Valid BIS license no.,rating & date of validity for engine.

N.A

15

Valid BIS license no.,rating & date of validity for alternator.

N.A

16

Confirmation regarding COP certificate of DG Sets from an authorized agency for emission norms for each model of engine quoted, to D(QA) at the time of inspection.

CONFIRMED

17

Make/Model/RPM of alternator

TRIDENT-BRAND KIRLOSKAR GREENKG184D/DGS&D TYPE TESTED/1500

QUESTIONNAIRE DIESEL GENERATING SET WITH AMF CONTROL PANEL: S.no 1 1.01

1.02 1.03 1.04 1.05 1.06 1.07 1.08 1.09 1.1 1.11 1.12 1.13 1.14 1.15 2.01 2.02 2.03

2.04 2.05

2.06

Item Description Item No. 8 Diesel Generating Sets M/s Electro Equipments Guaranteed Technical Particulars (GTP) of DG Furnished Below Sets (To be furnished by tenderers for each quoted item separately) Name of DG Set Manufacturer Electro Equipments Model number KG7.5WS Rated power output and duty cycle 7.5 KVA, CONTINUOUS Rated voltage, current, power factor and 240V, 31.3A, 0.8PF, 50HZ frequency Voltage regulation VG-1 or Better GRADE UPTO 82.5KVA AND VG-3 GRADE ABOVE 82.5 KVA Maximum temperature rise above ambient AS PER INSULATION (for engine) Class of insulation H or BETTER Efficiency of the alternator AS PER MANUFACTURER TYPE TEST CERTIFICATE Speed of revolution (RPM) at no load and 1500 RPM+ 4.5% rated voltage Type of excitation and excitation voltage SELF EXCITED Ambient conditions for which the DG set is AS PER IS suitable Type of enclosure SPDP Type of loads for which the genset is suitable 0.8 POWER FACTOR (LAG) Maximum load that can be switched on or off and voltage drop/rise permitted Engine model number & manufacturer Type of cooling Fuel tank capacity (it shall be suitable for 12 hours minimum at rated load and at continuous operation) Total fuel consumption in liters/KWh Rated engine power and the ambient conditions at which rated power is defined

FULL LOAD, AS PER IS STANDARD EW14/ KIRLOSKAR WATER COOLED SUITABLE FOR MINIMUM 12 HRS.

AS PER MANUFACTURER 14 BHP, AT STANDARD CONDITIONS

2.07

Other standard fittings of the engine to be AS PER MANUFACTURER specified by the tenderers Specific fuel consumption (in gms/kwh) 230 GMS/KW-HR/AS PER IS10000

3.01

Dry weight of the DG Set with canopy

850 KG APPROX

4

Maximum continuous operating time at rated load Peak power output and the duration for which the DG set can deliver this output

AS PER RELAVENT IS/BS STANDARD AS APPLICABLE 10% OVERLOAD FOR 1 HR FOR EVERY 11HRS CONTINUOUS RUNNING AT RATED LOAD.

6

Manual control panel with composite digital display meter, make, class & range for measurement of voltage, current, pf, frequency, kwh.

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKECONZERVE/SECURE/AE/L&T/INDOTECH/ HPL/ NIPPEN/ AS PER DGS&D NORMS

7

Microprocessor based AMF control panel with composite digital display meter, make, class & range for measurement of voltage,current, pf, frequency, kwh.

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKEUTOPIA/KIRLOSKAR/AS PER DGS&D NORMS

8

Submission of valid and renewed COP ATTACHED certificate of DG Set from an authorized certification agency.

9

Submission of valid and renewed TAC CONFIRMED certificate of DG set from an authorized certification agency.

10

Vibration level maximum

AS PER IS:8528-9

11

Type of coupling and mounting details

CLOSED COUPLED OR DIAPHRAGM COUPLING AS PER ENGINE MANUFACTURE STANDARD

12

Deviation in the generator specification from IS specification, if any. Confirmation regarding submission of copy of type approval certificate form an authorized agency for emission norms for each model of engine quoted to D(QA) at the time of inspection.

5

13

NIL CONFIRMED

14

Valid BIS license no.,rating & date of validity for engine.

ATTACHED

15

Valid BIS license no.,rating & date of validity for alternator.

ATTACHED

16

Confirmation regarding COP certificate of DG Sets from an authorized agency for emission norms for each model of engine quoted, to D(QA) at the time of inspection.

CONFIRMED

17

Make/Model/RPM of alternator

TRIDENT-BRAND KIRLOSKAR GREENKG164H/DGS&D TYPE TESTED/1500

QUESTIONNAIRE DIESEL GENERATING SET WITH AMF CONTROL PANEL: S.no 1 1.01

1.02 1.03 1.04 1.05 1.06 1.07 1.08 1.09 1.1 1.11 1.12 1.13 1.14 1.15 2.01 2.02 2.03

2.04 2.05

2.06

Item Description Item No. 9 Diesel Generating Sets M/s Electro Equipments Guaranteed Technical Particulars (GTP) of DG Furnished Below Sets (To be furnished by tenderers for each quoted item separately) Name of DG Set Manufacturer Electro Equipments Model number KG10WS Rated power output and duty cycle 10 KVA, CONTINUOUS Rated voltage, current, power factor and 240V, 41.7A, 0.8PF, 50HZ frequency Voltage regulation VG-1 or Better GRADE UPTO 82.5KVA AND VG-3 GRADE ABOVE 82.5 KVA Maximum temperature rise above ambient AS PER INSULATION (for engine) Class of insulation H or BETTER Efficiency of the alternator AS PER MANUFACTURER TYPE TEST CERTIFICATE Speed of revolution (RPM) at no load and 1500 RPM+ 4.5% rated voltage Type of excitation and excitation voltage SELF EXCITED Ambient conditions for which the DG set is AS PER IS suitable Type of enclosure SPDP Type of loads for which the genset is suitable 0.8 POWER FACTOR (LAG) Maximum load that can be switched on or off and voltage drop/rise permitted Engine model number & manufacturer Type of cooling Fuel tank capacity (it shall be suitable for 12 hours minimum at rated load and at continuous operation) Total fuel consumption in liters/KWh Rated engine power and the ambient conditions at which rated power is defined

FULL LOAD, AS PER IS STANDARD EW14/ KIRLOSKAR WATER COOLED SUITABLE FOR MINIMUM 12 HRS.

AS PER MANUFACTURER 14 BHP, AT STANDARD CONDITIONS

2.07

Other standard fittings of the engine to be AS PER MANUFACTURER specified by the tenderers Specific fuel consumption (in gms/kwh) 230 GMS/KW-HR/AS PER IS10000

3.01

Dry weight of the DG Set with canopy

850 KG APPROX

4

Maximum continuous operating time at rated load Peak power output and the duration for which the DG set can deliver this output

AS PER RELAVENT IS/BS STANDARD AS APPLICABLE 10% OVERLOAD FOR 1 HR FOR EVERY 11HRS CONTINUOUS RUNNING AT RATED LOAD.

6

Manual control panel with composite digital display meter, make, class & range for measurement of voltage, current, pf, frequency, kwh.

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKECONZERVE/SECURE/AE/L&T/INDOTECH/ HPL/ NIPPEN/ AS PER DGS&D NORMS

7

Microprocessor based AMF control panel with composite digital display meter, make, class & range for measurement of voltage,current, pf, frequency, kwh.

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKEUTOPIA/KIRLOSKAR/AS PER DGS&D NORMS

8

Submission of valid and renewed COP ATTACHED certificate of DG Set from an authorized certification agency.

9

Submission of valid and renewed TAC CONFIRMED certificate of DG set from an authorized certification agency.

10

Vibration level maximum

AS PER IS:8528-9

11

Type of coupling and mounting details

CLOSED COUPLED OR DIAPHRAGM COUPLING AS PER ENGINE MANUFACTURE STANDARD

12

Deviation in the generator specification from IS specification, if any. Confirmation regarding submission of copy of type approval certificate form an authorized agency for emission norms for each model of engine quoted to D(QA) at the time of inspection.

5

13

NIL CONFIRMED

14

Valid BIS license no.,rating & date of validity for engine.

ATTACHED

15

Valid BIS license no.,rating & date of validity for alternator.

ATTACHED

16

Confirmation regarding COP certificate of DG Sets from an authorized agency for emission norms for each model of engine quoted, to D(QA) at the time of inspection.

CONFIRMED

17

Make/Model/RPM of alternator

TRIDENT-BRAND KIRLOSKAR GREENKG164J/DGS&D TYPE TESTED/1500

QUESTIONNAIRE DIESEL GENERATING SET WITH AMF CONTROL PANEL: S.no 1 1.01

1.02 1.03 1.04 1.05 1.06 1.07 1.08 1.09 1.1 1.11 1.12 1.13 1.14 1.15 2.01 2.02 2.03

2.04 2.05

2.06

Item Description Item No. 12 Diesel Generating Sets M/s Electro Equipments Guaranteed Technical Particulars (GTP) of DG Furnished Below Sets (To be furnished by tenderers for each quoted item separately) Name of DG Set Manufacturer Electro Equipments Model number SEKG10AS5 Rated power output and duty cycle 10 KVA, CONTINUOUS Rated voltage, current, power factor and 415V, 13.9A, 0.8PF, 50HZ frequency Voltage regulation VG-1 or Better GRADE UPTO 82.5KVA AND VG-3 GRADE ABOVE 82.5 KVA Maximum temperature rise above ambient AS PER INSULATION (for engine) Class of insulation H or BETTER Efficiency of the alternator AS PER MANUFACTURER TYPE TEST CERTIFICATE Speed of revolution (RPM) at no load and 1500 RPM+ 4.5% rated voltage Type of excitation and excitation voltage SELF EXCITED Ambient conditions for which the DG set is AS PER IS suitable Type of enclosure SPDP Type of loads for which the genset is suitable 0.8 POWER FACTOR (LAG) Maximum load that can be switched on or off and voltage drop/rise permitted Engine model number & manufacturer Type of cooling Fuel tank capacity (it shall be suitable for 12 hours minimum at rated load and at continuous operation) Total fuel consumption in liters/KWh Rated engine power and the ambient conditions at which rated power is defined

FULL LOAD, AS PER IS STANDARD EA16/ KIRLOSKAR AIR COOLED SUITABLE FOR MINIMUM 12 HRS.

AS PER MANUFACTURER 16 BHP, AT STANDARD CONDITIONS

2.07

Other standard fittings of the engine to be AS PER MANUFACTURER specified by the tenderers Specific fuel consumption (in gms/kwh) 235 gms/kw-hr/ AS PER IS 10000

3.01

Dry weight of the DG Set with canopy

850 KG APPROX

4

Maximum continuous operating time at rated load Peak power output and the duration for which the DG set can deliver this output

AS PER RELAVENT IS/BS STANDARD AS APPLICABLE 10% OVERLOAD FOR 1 HR FOR EVERY 11HRS CONTINUOUS RUNNING AT RATED LOAD.

6

Manual control panel with composite digital display meter, make, class & range for measurement of voltage, current, pf, frequency, kwh.

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKECONZERVE/SECURE/AE/L&T/INDOTECH/ HPL/ NIPPEN/ AS PER DGS&D NORMS

7

Microprocessor based AMF control panel with composite digital display meter, make, class & range for measurement of voltage,current, pf, frequency, kwh.

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKEUTOPIA/KIRLOSKAR/AS PER DGS&D NORMS

8

Submission of valid and renewed COP ATTACHED certificate of DG Set from an authorized certification agency.

9

Submission of valid and renewed TAC CONFIRMED certificate of DG set from an authorized certification agency.

10

Vibration level maximum

AS PER IS:8528-9

11

Type of coupling and mounting details

CLOSED COUPLED OR DIAPHRAGM COUPLING AS PER ENGINE MANUFACTURE STANDARD

12

Deviation in the generator specification from IS specification, if any. Confirmation regarding submission of copy of type approval certificate form an authorized agency for emission norms for each model of engine quoted to D(QA) at the time of inspection.

5

13

NIL CONFIRMED

14

Valid BIS license no.,rating & date of validity for engine.

ATTACHED

15

Valid BIS license no.,rating & date of validity for alternator.

ATTACHED

16

Confirmation regarding COP certificate of DG Sets from an authorized agency for emission norms for each model of engine quoted, to D(QA) at the time of inspection.

CONFIRMED

17

Make/Model/RPM of alternator

TRIDENT-BRAND KIRLOSKAR GREENKG164G/DGS&D TYPE TESTED/1500

QUESTIONNAIRE DIESEL GENERATING SET WITH AMF CONTROL PANEL: S.no 1 1.01

1.02 1.03 1.04 1.05 1.06 1.07 1.08 1.09 1.1 1.11 1.12 1.13 1.14 1.15 2.01 2.02 2.03

2.04 2.05

2.06

Item Description Item No. 13 Diesel Generating Sets M/s Electro Equipments Guaranteed Technical Particulars (GTP) of DG Furnished Below Sets (To be furnished by tenderers for each quoted item separately) Name of DG Set Manufacturer Electro Equipments Model number KG15AS4 Rated power output and duty cycle 15 KVA, CONTINUOUS Rated voltage, current, power factor and 415V, 20.9A, 0.8PF, 50HZ frequency Voltage regulation VG-1 or Better GRADE UPTO 82.5KVA AND VG-3 GRADE ABOVE 82.5 KVA Maximum temperature rise above ambient AS PER INSULATION (for engine) Class of insulation H or BETTER Efficiency of the alternator AS PER MANUFACTURER TYPE TEST CERTIFICATE Speed of revolution (RPM) at no load and 1500 RPM+ 4.5% rated voltage Type of excitation and excitation voltage SELF EXCITED Ambient conditions for which the DG set is AS PER IS suitable Type of enclosure SPDP Type of loads for which the genset is suitable 0.8 POWER FACTOR (LAG) Maximum load that can be switched on or off and voltage drop/rise permitted Engine model number & manufacturer Type of cooling Fuel tank capacity (it shall be suitable for 12 hours minimum at rated load and at continuous operation) Total fuel consumption in liters/KWh Rated engine power and the ambient conditions at which rated power is defined

FULL LOAD, AS PER IS STANDARD HA294 SR III/ KIRLOSKAR AIR COOLED SUITABLE FOR MINIMUM 12 HRS.

AS PER MANUFACTURER 20.5 BHP, AT STANDARD CONDITIONS

2.07

Other standard fittings of the engine to be AS PER MANUFACTURER specified by the tenderers Specific fuel consumption (in gms/kwh) 242 GMS/KW-HR/AS PER IS 10000

3.01

Dry weight of the DG Set with canopy

900 KG APPROX

4

Maximum continuous operating time at rated load Peak power output and the duration for which the DG set can deliver this output

AS PER RELAVENT IS/BS STANDARD AS APPLICABLE 10% OVERLOAD FOR 1 HR FOR EVERY 11HRS CONTINUOUS RUNNING AT RATED LOAD.

6

Manual control panel with composite digital display meter, make, class & range for measurement of voltage, current, pf, frequency, kwh.

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKECONZERVE/SECURE/AE/L&T/INDOTECH/ HPL/ NIPPEN/ AS PER DGS&D NORMS

7

Microprocessor based AMF control panel with composite digital display meter, make, class & range for measurement of voltage,current, pf, frequency, kwh.

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKEUTOPIA/KIRLOSKAR/AS PER DGS&D NORMS

8

Submission of valid and renewed COP ATTACHED certificate of DG Set from an authorized certification agency.

9

Submission of valid and renewed TAC CONFIRMED certificate of DG set from an authorized certification agency.

10

Vibration level maximum

AS PER IS:8528-9

11

Type of coupling and mounting details

CLOSED COUPLED OR DIAPHRAGM COUPLING AS PER ENGINE MANUFACTURE STANDARD

12

Deviation in the generator specification from IS specification, if any. Confirmation regarding submission of copy of type approval certificate form an authorized agency for emission norms for each model of engine quoted to D(QA) at the time of inspection.

5

13

NIL CONFIRMED

14

Valid BIS license no.,rating & date of validity for engine.

ATTACHED

15

Valid BIS license no.,rating & date of validity for alternator.

ATTACHED

16

Confirmation regarding COP certificate of DG Sets from an authorized agency for emission norms for each model of engine quoted, to D(QA) at the time of inspection.

CONFIRMED

17

Make/Model/RPM of alternator

TRIDENT-BRAND KIRLOSKAR GREENKG164J/DGS&D TYPE TESTED/1500

QUESTIONNAIRE DIESEL GENERATING SET WITH AMF CONTROL PANEL: S.no 1 1.01

1.02 1.03 1.04 1.05 1.06 1.07 1.08 1.09 1.1 1.11 1.12 1.13 1.14 1.15 2.01 2.02 2.03

2.04 2.05

2.06

Item Description Item No. 13A Diesel Generating Sets M/s Electro Equipments Guaranteed Technical Particulars (GTP) of DG Furnished Below Sets (To be furnished by tenderers for each quoted item separately) Name of DG Set Manufacturer Electro Equipments Model number SEKG15AS6 Rated power output and duty cycle 15 KVA, CONTINUOUS Rated voltage, current, power factor and 240V, 62.5A, 0.8PF, 50HZ frequency Voltage regulation VG-1 or Better GRADE UPTO 82.5KVA AND VG-3 GRADE ABOVE 82.5 KVA Maximum temperature rise above ambient AS PER INSULATION (for engine) Class of insulation H or BETTER Efficiency of the alternator AS PER MANUFACTURER TYPE TEST CERTIFICATE Speed of revolution (RPM) at no load and 1500 RPM+4.5% rated voltage Type of excitation and excitation voltage SELF EXCITED Ambient conditions for which the DG set is AS PER IS suitable Type of enclosure SPDP Type of loads for which the genset is suitable 0.8 POWER FACTOR (LAG) Maximum load that can be switched on or off and voltage drop/rise permitted Engine model number & manufacturer Type of cooling Fuel tank capacity (it shall be suitable for 12 hours minimum at rated load and at continuous operation) Total fuel consumption in liters/KWh Rated engine power and the ambient conditions at which rated power is defined

FULL LOAD, AS PER IS STANDARD EA20 / KIRLOSKAR AIR COOLED SUITABLE FOR MINIMUM12 HRS.

AS PER MANUFACTURER 20 BHP, AT STANDARD CONDITIONS

2.07

Other standard fittings of the engine to be AS PER MANUFACTURER specified by the tenderers Specific fuel consumption (in gms/kwh) 242 GMS/KW-HR/AS PER IS 10000

3.01

Dry weight of the DG Set with canopy

900 KG APPROX

4

Maximum continuous operating time at rated load Peak power output and the duration for which the DG set can deliver this output

AS PER RELAVENT IS/BS STANDARD AS APPLICABLE 10% OVERLOAD FOR 1 HR FOR EVERY 11HRS CONTINUOUS RUNNING AT RATED LOAD.

6

Manual control panel with composite digital display meter, make, class & range for measurement of voltage, current, pf, frequency, kwh.

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKECONZERVE/SECURE/AE/L&T/INDOTECH/ HPL/ NIPPEN/ AS PER DGS&D NORMS

7

Microprocessor based AMF control panel with composite digital display meter, make, class & range for measurement of voltage,current, pf, frequency, kwh.

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKEUTOPIA/KIRLOSKAR/AS PER DGS&D NORMS

8

Submission of valid and renewed COP Attached certificate of DG Set from an authorized certification agency.

9

Submission of valid and renewed TAC CONFIRMED certificate of DG set from an authorized certification agency.

10

Vibration level maximum

AS PER IS:8528-9

11

Type of coupling and mounting details

CLOSED COUPLED OR DIAPHRAGM COUPLING AS PER ENGINE MANUFACTURE STANDARD

12

Deviation in the generator specification from IS specification, if any. Confirmation regarding submission of copy of type approval certificate form an authorized agency for emission norms for each model of engine quoted to D(QA) at the time of inspection.

5

13

NIL CONFIRMED

14

Valid BIS license no.,rating & date of validity for engine.

Attached

15

Valid BIS license no.,rating & date of validity for alternator.

Attached

16

Confirmation regarding COP certificate of DG Sets from an authorized agency for emission norms for each model of engine quoted, to D(QA) at the time of inspection.

CONFIRMED

17

Make/Model/RPM of alternator

TRIDENT-BRAND KIRLOSKAR GREENKG164J/DGS&D TYPE TESTED/1500

QUESTIONNAIRE DIESEL GENERATING SET WITH AMF CONTROL PANEL: S.no 1 1.01

1.02 1.03 1.04 1.05 1.06 1.07 1.08 1.09 1.1 1.11 1.12 1.13 1.14 1.15 2.01 2.02 2.03

2.04 2.05

2.06

Item Description Item No. 14 Diesel Generating Sets M/s Electro Equipments Guaranteed Technical Particulars (GTP) of DG Furnished Below Sets (To be furnished by tenderers for each quoted item separately) Name of DG Set Manufacturer Electro Equipments Model number KG25AS-C Rated power output and duty cycle 20 KVA, CONTINUOUS Rated voltage, current, power factor and 415V, 27.8A, 0.8PF, 50HZ frequency Voltage regulation VG-1 or Better GRADE UPTO 82.5KVA AND VG-3 GRADE ABOVE 82.5 KVA Maximum temperature rise above ambient AS PER INSULATION (for engine) Class of insulation H or BETTER Efficiency of the alternator AS PER MANUFACTURER TYPE TEST CERTIFICATE Speed of revolution (RPM) at no load and 1500 RPM + 4.5% rated voltage Type of excitation and excitation voltage SELF EXCITED Ambient conditions for which the DG set is AS PER IS suitable Type of enclosure SPDP Type of loads for which the genset is suitable 0.8 POWER FACTOR (LAG) Maximum load that can be switched on or off and voltage drop/rise permitted Engine model number & manufacturer Type of cooling Fuel tank capacity (it shall be suitable for 12 hours minimum at rated load and at continuous operation) Total fuel consumption in liters/KWh Rated engine power and the ambient conditions at which rated power is defined

FULL LOAD, AS PER IS STANDARD HA394 / KIRLOSKAR AIR COOLED SUITABLE FOR MINIMUM 12 HRS.

AS PER MANUFACTURER 32 BHP, AT STANDARD CONDITIONS

2.07

Other standard fittings of the engine to be AS PER MANUFACTURER specified by the tenderers Specific fuel consumption (in gms/kwh) 174 GMS/HP-HR/AS PER IS 10000

3.01

Dry weight of the DG Set with canopy

1050 KG APPROX

4

Maximum continuous operating time at rated load Peak power output and the duration for which the DG set can deliver this output

AS PER RELAVENT IS/BS STANDARD AS APPLICABLE 10% OVERLOAD FOR 1 HR FOR EVERY 11HRS CONTINUOUS RUNNING AT RATED LOAD.

6

Manual control panel with composite digital display meter, make, class & range for measurement of voltage, current, pf, frequency, kwh.

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKECONZERVE/SECURE/AE/L&T/INDOTECH/ HPL/ NIPPEN/ AS PER DGS&D NORMS

7

Microprocessor based AMF control panel with composite digital display meter, make, class & range for measurement of voltage,current, pf, frequency, kwh.

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKEUTOPIA/KIRLOSKAR/AS PER DGS&D NORMS

8

Submission of valid and renewed COP ATTACHED certificate of DG Set from an authorized certification agency.

9

Submission of valid and renewed TAC CONFIRMED certificate of DG set from an authorized certification agency.

10

Vibration level maximum

AS PER IS:8528-9

11

Type of coupling and mounting details

CLOSED COUPLED OR DIAPHRAGM COUPLING AS PER ENGINE MANUFACTURE STANDARD

12

Deviation in the generator specification from IS specification, if any. Confirmation regarding submission of copy of type approval certificate form an authorized agency for emission norms for each model of engine quoted to D(QA) at the time of inspection.

5

13

NIL CONFIRMED

14

Valid BIS license no.,rating & date of validity for engine.

N.A

15

Valid BIS license no.,rating & date of validity for alternator.

N.A

16

Confirmation regarding COP certificate of DG Sets from an authorized agency for emission norms for each model of engine quoted, to D(QA) at the time of inspection.

CONFIRMED

17

Make/Model/RPM of alternator

TRIDENT-BRAND KIRLOSKAR GREENKG184A/DGS&D TYPE TESTED/1500

QUESTIONNAIRE DIESEL GENERATING SET WITH AMF CONTROL PANEL: S.no 1 1.01

1.02 1.03 1.04 1.05 1.06 1.07 1.08 1.09 1.1 1.11 1.12 1.13 1.14 1.15 2.01 2.02 2.03

2.04 2.05

2.06

Item Description Item No. 15 Diesel Generating Sets M/s Electro Equipments Guaranteed Technical Particulars (GTP) of DG Furnished Below Sets (To be furnished by tenderers for each quoted item separately) Name of DG Set Manufacturer Electro Equipments Model number KG25AS-C Rated power output and duty cycle 25 KVA, CONTINUOUS Rated voltage, current, power factor and 240V, 34.8A, 0.8PF, 50HZ frequency Voltage regulation VG-1 or Better GRADE UPTO 82.5KVA AND VG-3 GRADE ABOVE 82.5 KVA Maximum temperature rise above ambient AS PER INSULATION (for engine) Class of insulation H or BETTER Efficiency of the alternator AS PER MANUFACTURER TYPE TEST CERTIFICATE Speed of revolution (RPM) at no load and 1500 RPM+4.5% rated voltage Type of excitation and excitation voltage SELF EXCITED Ambient conditions for which the DG set is AS PER IS suitable Type of enclosure ACOUSTIC Type of loads for which the genset is suitable 0.8 POWER FACTOR (LAG) Maximum load that can be switched on or off and voltage drop/rise permitted Engine model number & manufacturer Type of cooling Fuel tank capacity (it shall be suitable for 12 hours minimum at rated load and at continuous operation) Total fuel consumption in liters/KWh Rated engine power and the ambient conditions at which rated power is defined

FULL LOAD, AS PER IS STANDARD HA394 / KIRLOSKAR AIR COOLED SUITABLE FOR MINIMUM 12 HRS.

AS PER MANUFACTURER 32 BHP, AT STANDARD CONDITIONS

2.07

Other standard fittings of the engine to be AS PER MANUFACTURER specified by the tenderers Specific fuel consumption (in gms/kwh) 174 GMS/HP-HR/ AS PER IS 10000

3.01

Dry weight of the DG Set with canopy

1030 KG APPROX

4

Maximum continuous operating time at rated load Peak power output and the duration for which the DG set can deliver this output

AS PER RELAVENT IS/BS STANDARD AS APPLICABLE 10% OVERLOAD FOR 1 HR FOR EVERY 11HRS CONTINUOUS RUNNING AT RATED LOAD.

6

Manual control panel with composite digital display meter, make, class & range for measurement of voltage, current, pf, frequency, kwh.

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKECONZERVE/SECURE/AE/L&T/INDOTECH/ HPL/ NIPPEN/ AS PER DGS&D NORMS

7

Microprocessor based AMF control panel with composite digital display meter, make, class & range for measurement of voltage,current, pf, frequency, kwh.

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKEUTOPIA/KIRLOSKAR/AS PER DGS&D NORMS

8

Submission of valid and renewed COP ATTACHED certificate of DG Set from an authorized certification agency.

9

Submission of valid and renewed TAC CONFIRMED certificate of DG set from an authorized certification agency.

10

Vibration level maximum

AS PER IS:8528-9

11

Type of coupling and mounting details

CLOSED COUPLED COUPLING AS MANUFACTURE

12

Deviation in the generator specification from IS specification, if any. Confirmation regarding submission of copy of type approval certificate form an authorized agency for emission norms for each model of engine quoted to D(QA) at the time of inspection.

5

13

OR DIAPHRAGM PER ENGINE

NIL CONFIRMED

14

Valid BIS license no.,rating & date of validity for engine.

N.A

15

Valid BIS license no.,rating & date of validity for alternator.

N.A

16

Confirmation regarding COP certificate of DG Sets from an authorized agency for emission norms for each model of engine quoted, to D(QA) at the time of inspection.

CONFIRMED

17

Make/Model/RPM of alternator

TRIDENT-BRAND KIRLOSKAR GREENKG184B/DGS&D TYPE TESTED/1500

QUESTIONNAIRE DIESEL GENERATING SET WITH AMF CONTROL PANEL: S.no 1 1.01

1.02 1.03 1.04 1.05 1.06 1.07 1.08 1.09 1.1 1.11 1.12 1.13 1.14 1.15 2.01 2.02 2.03

2.04 2.05

2.06

Item Description Item No. 16 Diesel Generating Sets M/s Electro Equipments Guaranteed Technical Particulars (GTP) of DG Furnished Below Sets (To be furnished by tenderers for each quoted item separately) Name of DG Set Manufacturer Electro Equipments Model number KG35AS Rated power output and duty cycle 30 KVA, CONTINUOUS Rated voltage, current, power factor and 240V, 41.7A, 0.8PF, 50HZ frequency Voltage regulation VG-1 or Better GRADE UPTO 82.5KVA AND VG-3 GRADE ABOVE 82.5 KVA Maximum temperature rise above ambient AS PER INSULATION (for engine) Class of insulation H or BETTER Efficiency of the alternator AS PER MANUFACTURER TYPE TEST CERTIFICATE Speed of revolution (RPM) at no load and 1500 RPM +4.5% rated voltage Type of excitation and excitation voltage SELF EXCITED Ambient conditions for which the DG set is AS PER IS suitable Type of enclosure ACOUSTIC Type of loads for which the genset is suitable 0.8 POWER FACTOR (LAG) Maximum load that can be switched on or off and voltage drop/rise permitted Engine model number & manufacturer Type of cooling Fuel tank capacity (it shall be suitable for 12 hours minimum at rated load and at continuous operation) Total fuel consumption in liters/KWh Rated engine power and the ambient conditions at which rated power is defined

FULL LOAD, AS PER IS STANDARD HA494 / KIRLOSKAR AIR COOLED SUITABLE FOR 12 HRS.

AS PER MANUFACTURER 43 BHP, AT STANDARD CONDITIONS

2.07

Other standard fittings of the engine to be AS PER MANUFACTURER specified by the tenderers Specific fuel consumption (in gms/kwh) 163 GMS/HP-HR/ AS PER IS 10000

3.01

Dry weight of the DG Set with canopy

1440 KG APPROX

4

Maximum continuous operating time at rated load Peak power output and the duration for which the DG set can deliver this output

AS PER RELAVENT IS STANDARD AS APPLICABLE 10% OVERLOAD FOR 1 HR FOR EVERY 11HRS CONTINUOUS RUNNING AT RATED LOAD.

6

Manual control panel with composite digital display meter, make, class & range for measurement of voltage, current, pf, frequency, kwh.

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKECONZERVE/SECURE/AE/L&T/INDOTECH/ HPL/ NIPPEN/ AS PER DGS&D NORMS

7

Microprocessor based AMF control panel with composite digital display meter, make, class & range for measurement of voltage,current, pf, frequency, kwh.

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKEUTOPIA/KIRLOSKAR/AS PER DGS&D NORMS

8

Submission of valid and renewed COP ATTACHED certificate of DG Set from an authorized certification agency.

9

Submission of valid and renewed TAC CONFIRMED certificate of DG set from an authorized certification agency.

10

Vibration level maximum

AS PER IS:8528-9

11

Type of coupling and mounting details

CLOSED COUPLED COUPLING AS MANUFACTURE

12

Deviation in the generator specification from IS specification, if any. Confirmation regarding submission of copy of type approval certificate form an authorized agency for emission norms for each model of engine quoted to D(QA) at the time of inspection.

5

13

OR DIAPHRAGM PER ENGINE

NIL CONFIRMED

14

Valid BIS license no.,rating & date of validity for engine.

N.A

15

Valid BIS license no.,rating & date of validity for alternator.

N.A

16

Confirmation regarding COP certificate of DG Sets from an authorized agency for emission norms for each model of engine quoted, to D(QA) at the time of inspection.

CONFIRMED

17

Make/Model/RPM of alternator

TRIDENT-BRAND KIRLOSKAR GREENKG184C/DGS&D TYPE TESTED/1500

QUESTIONNAIRE DIESEL GENERATING SET WITH AMF CONTROL PANEL: S.no 1 1.01

1.02 1.03 1.04 1.05 1.06 1.07 1.08 1.09 1.1 1.11 1.12 1.13 1.14 1.15 2.01 2.02 2.03

2.04 2.05

2.06

Item Description Item No. 18 Diesel Generating Sets M/s Electro Equipments Guaranteed Technical Particulars (GTP) of DG Furnished Below Sets (To be furnished by tenderers for each quoted item separately) Name of DG Set Manufacturer Electro Equipments Model number KG40AS Rated power output and duty cycle 40 KVA, CONTINUOUS Rated voltage, current, power factor and 415V, 55.6A, 0.8PF, 50HZ frequency Voltage regulation VG-1 or Better GRADE UPTO 82.5KVA AND VG-3 GRADE ABOVE 82.5 KVA Maximum temperature rise above ambient AS PER INSULATION (for engine) Class of insulation H or BETTER Efficiency of the alternator AS PER MANUFACTURER TYPE TEST CERTIFICATE Speed of revolution (RPM) at no load and 1500 RPM + 4.5% rated voltage Type of excitation and excitation voltage SELF EXCITED Ambient conditions for which the DG set is AS PER IS suitable Type of enclosure SPDP Type of loads for which the genset is suitable 0.8 POWER FACTOR (LAG) Maximum load that can be switched on or off and voltage drop/rise permitted Engine model number & manufacturer Type of cooling Fuel tank capacity (it shall be suitable for 12 hours minimum at rated load and at continuous operation) Total fuel consumption in liters/KWh Rated engine power and the ambient conditions at which rated power is defined

FULL LOAD, AS PER IS STANDARD HA494T / KIRLOSKAR AIR COOLED SUITABLE FOR MINIMUM 12 HRS.

AS PER MANUFACTURER 56 BHP, AT STANDARD CONDITIONS

2.07

Other standard fittings of the engine to be AS PER MANUFACTURER specified by the tenderers Specific fuel consumption (in gms/kwh) 166 GMS/HP-HR/AS PER IS 10000

3.01

Dry weight of the DG Set with canopy

1580 KG APPROX

4

Maximum continuous operating time at rated load Peak power output and the duration for which the DG set can deliver this output

AS PER RELAVENT IS/BS STANDARD AS APPLICABLE 10% OVERLOAD FOR 1 HR FOR EVERY 11HRS CONTINUOUS RUNNING AT RATED LOAD.

6

Manual control panel with composite digital display meter, make, class & range for measurement of voltage, current, pf, frequency, kwh.

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKECONZERVE/SECURE/AE/L&T/INDOTECH/ HPL/ NIPPEN/ AS PER DGS&D NORMS

7

Microprocessor based AMF control panel with composite digital display meter, make, class & range for measurement of voltage,current, pf, frequency, kwh.

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKEUTOPIA/KIRLOSKAR/AS PER DGS&D NORMS

8

Submission of valid and renewed COP ATTACHED certificate of DG Set from an authorized certification agency.

9

Submission of valid and renewed TAC CONFIRMED certificate of DG set from an authorized certification agency.

10

Vibration level maximum

AS PER IS:8528-9

11

Type of coupling and mounting details

CLOSED COUPLED COUPLING AS MANUFACTURE

12

Deviation in the generator specification from IS specification, if any. Confirmation regarding submission of copy of type approval certificate form an authorized agency for emission norms for each model of engine quoted to D(QA) at the time of inspection.

5

13

OR DIAPHRAGM PER ENGINE

NIL CONFIRMED

14

Valid BIS license no.,rating & date of validity for engine.

N.A

15

Valid BIS license no.,rating & date of validity for alternator.

N.A

16

Confirmation regarding COP certificate of DG Sets from an authorized agency for emission norms for each model of engine quoted, to D(QA) at the time of inspection.

CONFIRMED

17

Make/Model/RPM of alternator

TRIDENT-BRAND KIRLOSKAR GREENKG184E/DGS&D TYPE TESTED/1500

QUESTIONNAIRE DIESEL GENERATING SET WITH AMF CONTROL PANEL: S.no 1 1.01

1.02 1.03 1.04 1.05 1.06 1.07 1.08 1.09 1.1 1.11 1.12 1.13 1.14 1.15 2.01 2.02 2.03

2.04 2.05

2.06

Item Description Item No. 19 Diesel Generating Sets M/s Electro Equipments Guaranteed Technical Particulars (GTP) of DG Furnished Below Sets (To be furnished by tenderers for each quoted item separately) Name of DG Set Manufacturer Electro Equipments Model number KG10WS Rated power output and duty cycle 10 KVA, CONTINUOUS Rated voltage, current, power factor and 415V, 13.9A, 0.8PF, 50HZ frequency Voltage regulation VG-1 or Better GRADE UPTO 82.5KVA AND VG-3 GRADE ABOVE 82.5 KVA Maximum temperature rise above ambient AS PER INSULATION (for engine) Class of insulation H or BETTER Efficiency of the alternator AS PER MANUFACTURER TYPE TEST CERTIFICATE Speed of revolution (RPM) at no load and 1500 RPM +4.5% rated voltage Type of excitation and excitation voltage SELF EXCITED Ambient conditions for which the DG set is AS PER IS suitable Type of enclosure SPDP Type of loads for which the genset is suitable 0.8 POWER FACTOR (LAG) Maximum load that can be switched on or off and voltage drop/rise permitted Engine model number & manufacturer Type of cooling Fuel tank capacity (it shall be suitable for 12 hours minimum at rated load and at continuous operation) Total fuel consumption in liters/KWh Rated engine power and the ambient conditions at which rated power is defined

FULL LOAD, AS PER IS STANDARD EW14 / KIRLOSKAR WATER COOLED SUITABLE FOR 12 HRS.

AS PER MANUFACTURER 14 BHP, AT STANDARD CONDITIONS

2.07

Other standard fittings of the engine to be AS PER MANUFACTURER specified by the tenderers Specific fuel consumption (in gms/kwh) 230 GMS/KW-HR/AS PER IS10000

3.01

Dry weight of the DG Set with canopy

850 KG APPROX

4

Maximum continuous operating time at rated load Peak power output and the duration for which the DG set can deliver this output

AS PER RELAVENT IS/BS STANDARD AS APPLICABLE 10% OVERLOAD FOR 1 HR FOR EVERY 11HRS CONTINUOUS RUNNING AT RATED LOAD.

6

Manual control panel with composite digital display meter, make, class & range for measurement of voltage, current, pf, frequency, kwh.

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKECONZERVE/SECURE/AE/L&T/INDOTECH/ HPL/ NIPPEN/ AS PER DGS&D NORMS

7

Microprocessor based AMF control panel with composite digital display meter, make, class & range for measurement of voltage,current, pf, frequency, kwh.

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKEUTOPIA/KIRLOSKAR/AS PER DGS&D NORMS

8

Submission of valid and renewed COP ATTACHED certificate of DG Set from an authorized certification agency.

9

Submission of valid and renewed TAC CONFIRMED certificate of DG set from an authorized certification agency.

10

Vibration level maximum

AS PER IS:8528-9

11

Type of coupling and mounting details

CLOSED COUPLED OR DIAPHRAGM COUPLING AS PER ENGINE MANUFACTURE STANDARD

12

Deviation in the generator specification from IS specification, if any. Confirmation regarding submission of copy of type approval certificate form an authorized agency for emission norms for each model of engine quoted to D(QA) at the time of inspection.

5

13

NIL CONFIRMED

14

Valid BIS license no.,rating & date of validity for engine.

ATTACHED

15

Valid BIS license no.,rating & date of validity for alternator.

ATTACHED

16

Confirmation regarding COP certificate of DG Sets from an authorized agency for emission norms for each model of engine quoted, to D(QA) at the time of inspection.

CONFIRMED

17

Make/Model/RPM of alternator

TRIDENT-BRAND KIRLOSKAR GREENKG164G/DGS&D TYPE TESTED/1500

QUESTIONNAIRE DIESEL GENERATING SET WITH MANUAL CONTROL PANEL S.no 1 1.01

Item Description Diesel Generating Sets Guaranteed Technical Particulars (GTP) of DG Sets (To be furnished by tenderers for each quoted item separately)

1.02 1.03 1.04 1.05

Name of DG Set Manufacturer Electro Equipments Model number SEKG5AS7 Rated power output and duty cycle 3.5 KVA, CONTINUOUS Rated voltage, current, power factor and 240V, 14.58A, 0.8PF, 50HZ frequency Voltage regulation VG-1 or Better GRADE UPTO 82.5KVA AND VG-3 GRADE ABOVE 82.5 KVA Maximum temperature rise above ambient AS PER INSULATION (for engine) Class of insulation H or BETTER Efficiency of the alternator AS PER MANUFACTURER TYPE TEST CERTIFICATE Speed of revolution (RPM) at no load and 1500 RPM + 4.5% rated voltage Type of excitation and excitation voltage SELF EXCITED Ambient conditions for which the DG set is AS PER IS STANDARD suitable Type of enclosure SPDP Type of loads for which the genset is suitable 0.8 POWER FACTOR (LAG)

1.06 1.07 1.08 1.09 1.1 1.11 1.12 1.13 1.14 1.15 2.01 2.02 2.03

2.04 2.05

2.06 2.07

Maximum load that can be switched on or off and voltage drop/rise permitted Engine model number & manufacturer Type of cooling Fuel tank capacity (it shall be suitable for 12 hours minimum at rated load and at continuous operation) Total fuel consumption in liters/Kwh Rated engine power and the ambient conditions at which rated power is defined Other standard fittings of the engine to be specified by the tenderers Specific fuel consumption (in gms/kwh)

Item No.26 M/s Electro Equipments Furnished Below

FULL LOAD, AS PER IS STANDARD EA10 / KIRLOSKAR AIR COOLED SUITABLE FOR MINIMUM12 HRS.

AS PER MANUFACTURER 10 BHP, AT STANDARD CONDITIONS

AS PER MANUFACTURER 230 gms/kw-hr/ AS PER IS 10000

3.01 4 5

6

Dry weight of the DG Set with canopy Maximum continuous operating time at rated load Peak power output and the duration for which the DG set can deliver this output

650 kg Approx AS PER RELAVENT IS STANDARD AS APPLICABLE 10% OVERLOAD FOR 1 HR FOR EVERY 11HRS CONTINUOUS RUNNING AT RATED LOAD. Manual control panel with composite digital CLASS 1 OR AS PER SPECIFICATION, display meter, make, class & range for SUITABLE RANGE, MAKEmeasurement of voltage, current, pf, CONZERVE/SECURE/AE/L&T/INDOTECH/ frequency, kwh. HPL/ NIPPEN/ AS PER DGS&D NORMS

7

Microprocessor based AMF control panel with composite digital display meter, make, class & range for measurement of voltage,current, pf, frequency, kwh.

8

Attached Submission of valid and renewed COP certificate of DG Set from an authorized certification agency. CONFIRMED Submission of valid and renewed TAC certificate of DG set from an authorized certification agency. Vibration level maximum AS PER IS:8528-9 Type of coupling and mounting details CLOSED COUPLED OR DIAPHRAGM COUPLING AS PER ENGINE MANUFACTURE STANDARD

9

10 11

12 13

14 15 16

17

Deviation in the generator specification from IS specification, if any. Confirmation regarding submission of copy of type approval certificate form an authorized agency for emission norms for each model of engine quoted to D(QA) at the time of inspection. Valid BIS license no.,rating & date of validity for engine. Valid BIS license no.,rating & date of validity for alternator. Confirmation regarding COP certificate of DG Sets from an authorized agency for emission norms for each model of engine quoted, to D(QA) at the time of inspection. Make/Model/RPM of alternator

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKEUTOPIA/KIRLOSKAR/AS PER DGS&D NORMS

NIL CONFIRMED

Attached Attached CONFIRMED

TRIDENT-BRAND KIRLOSKAR GREENKG164G/DGS&D TYPE TESTED/1500

QUESTIONNAIRE DIESEL GENERATING SET WITH MANUAL CONTROL PANEL S.no 1 1.01

Item Description Diesel Generating Sets Guaranteed Technical Particulars (GTP) of DG Sets (To be furnished by tenderers for each quoted item separately)

1.02 1.03 1.04 1.05

Name of DG Set Manufacturer Electro Equipments Model number SEKG5AS7 Rated power output and duty cycle 5 KVA, CONTINUOUS Rated voltage, current, power factor and 240V, 20.8A, 0.8PF, 50HZ frequency Voltage regulation VG-1 or Better GRADE UPTO 82.5KVA AND VG-3 GRADE ABOVE 82.5 KVA Maximum temperature rise above ambient AS PER INSULATION (for engine) Class of insulation H or BETTER Efficiency of the alternator AS PER MANUFACTURER TYPE TEST CERTIFICATE Speed of revolution (RPM) at no load and 1500 RPM+4.5% rated voltage Type of excitation and excitation voltage SELF EXCITED Ambient conditions for which the DG set is AS PER IS suitable Type of enclosure SPDP Type of loads for which the genset is suitable 0.8 POWER FACTOR (LAG)

1.06 1.07 1.08 1.09 1.1 1.11 1.12 1.13 1.14 1.15 2.01 2.02 2.03

2.04 2.05

2.06 2.07

Maximum load that can be switched on or off and voltage drop/rise permitted Engine model number & manufacturer Type of cooling Fuel tank capacity (it shall be suitable for 12 hours minimum at rated load and at continuous operation) Total fuel consumption in liters/Kwh Rated engine power and the ambient conditions at which rated power is defined

Item No.27 M/s Electro Equipments Furnished Below

FULL LOAD, AS PER IS 10000 EA10 / KIRLOSKAR AIR COOLED SUITABLE FOR MINIMUM12 HRS.

AS PER MANUFACTURER 10 BHP, AT STANDARD CONDITIONS

Other standard fittings of the engine to be AS PER MANUFACTURER specified by the tenderers Specific fuel consumption (in gms/kwh) 230 gms/kw-hr/ AS PER IS STANDARD

3.01 4 5

6

Dry weight of the DG Set with canopy Maximum continuous operating time at rated load Peak power output and the duration for which the DG set can deliver this output

650 kg Approx AS PER RELAVENT IS/BS STANDARD AS APPLICABLE 10% OVERLOAD FOR 1 HR FOR EVERY 11HRS CONTINUOUS RUNNING AT RATED LOAD. Manual control panel with composite digital CLASS 1 OR AS PER SPECIFICATION, display meter, make, class & range for SUITABLE RANGE, MAKEmeasurement of voltage, current, pf, CONZERVE/SECURE/AE/L&T/INDOTECH/ frequency, kwh. HPL/ NIPPEN/ AS PER DGS&D NORMS

7

Microprocessor based AMF control panel with composite digital display meter, make, class & range for measurement of voltage,current, pf, frequency, kwh.

8

Submission of valid and renewed COP Attached certificate of DG Set from an authorized certification agency. Submission of valid and renewed TAC CONFIRMED certificate of DG set from an authorized certification agency. Vibration level maximum AS PER IS:8528-9 Type of coupling and mounting details CLOSED COUPLED OR DIAPHRAGM COUPLING AS PER ENGINE MANUFACTURE STANDARD

9

10 11

12 13

14 15 16

17

Deviation in the generator specification from IS specification, if any. Confirmation regarding submission of copy of type approval certificate form an authorized agency for emission norms for each model of engine quoted to D(QA) at the time of inspection. Valid BIS license no.,rating & date of validity for engine. Valid BIS license no.,rating & date of validity for alternator. Confirmation regarding COP certificate of DG Sets from an authorized agency for emission norms for each model of engine quoted, to D(QA) at the time of inspection. Make/Model/RPM of alternator

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKEUTOPIA/KIRLOSKAR/AS PER DGS&D NORMS

NIL CONFIRMED

Attached Attached CONFIRMED

TRIDENT-BRAND KIRLOSKAR GREENKG164G/DGS&D TYPE TESTED/1500

QUESTIONNAIRE DIESEL GENERATING SET WITH MANUAL CONTROL PANEL S.no 1 1.01

Item Description Diesel Generating Sets Guaranteed Technical Particulars (GTP) of DG Sets (To be furnished by tenderers for each quoted item separately)

1.02 1.03 1.04 1.05

Name of DG Set Manufacturer Electro Equipments Model number SEKG7.5AS5 Rated power output and duty cycle 7.5 KVA, CONTINUOUS Rated voltage, current, power factor and 240V, 31.3A, 0.8PF, 50HZ frequency Voltage regulation VG-1 or Better GRADE UPTO 82.5KVA AND VG-3 GRADE ABOVE 82.5 KVA Maximum temperature rise above ambient AS PER INSULATION (for engine) Class of insulation H or BETTER Efficiency of the alternator AS PER MANUFACTURER TYPE TEST CERTIFICATE Speed of revolution (RPM) at no load and 1500 RPM+4.5% rated voltage Type of excitation and excitation voltage SELF EXCITED Ambient conditions for which the DG set is AS PER IS suitable Type of enclosure SPDP Type of loads for which the genset is suitable 0.8 POWER FACTOR (LAG)

1.06 1.07 1.08 1.09 1.1 1.11 1.12 1.13 1.14 1.15 2.01 2.02 2.03

2.04 2.05

2.06 2.07

Maximum load that can be switched on or off and voltage drop/rise permitted Engine model number & manufacturer Type of cooling Fuel tank capacity (it shall be suitable for 12 hours minimum at rated load and at continuous operation) Total fuel consumption in liters/Kwh Rated engine power and the ambient conditions at which rated power is defined Other standard fittings of the engine to be specified by the tenderers Specific fuel consumption (in gms/kwh)

Item No.28 M/s Electro Equipments Furnished Below

FULL LOAD, AS PER IS STANDARD EA16 / KIRLOSKAR AIR COOLED SUITABLE FOR MINIMUM 12 HRS.

AS PER MANUFACTURER 16 BHP, AT STANDARD CONDITIONS

AS PER MANUFACTURER 235 gms/kw-hr/ AS PER IS 10000

3.01 4 5

6

Dry weight of the DG Set with canopy Maximum continuous operating time at rated load Peak power output and the duration for which the DG set can deliver this output

850 kg approx AS PER RELAVENT IS STANDARD AS APPLICABLE 10% OVERLOAD FOR 1 HR FOR EVERY 11HRS CONTINUOUS RUNNING AT RATED LOAD. Manual control panel with composite digital CLASS 1 OR AS PER SPECIFICATION, display meter, make, class & range for SUITABLE RANGE, MAKEmeasurement of voltage, current, pf, CONZERVE/SECURE/AE/L&T/INDOTECH/ frequency, kwh. HPL/ NIPPEN/ AS PER DGS&D NORMS

7

Microprocessor based AMF control panel with composite digital display meter, make, class & range for measurement of voltage,current, pf, frequency, kwh.

8

Submission of valid and renewed COP Attached certificate of DG Set from an authorized certification agency. Submission of valid and renewed TAC CONFIRMED certificate of DG set from an authorized certification agency. Vibration level maximum AS PER IS:8528-9 Type of coupling and mounting details CLOSED COUPLED OR DIAPHRAGM COUPLING AS PER ENGINE MANUFACTURE STANDARD

9

10 11

12 13

14 15 16

17

Deviation in the generator specification from IS specification, if any. Confirmation regarding submission of copy of type approval certificate form an authorized agency for emission norms for each model of engine quoted to D(QA) at the time of inspection. Valid BIS license no.,rating & date of validity for engine. Valid BIS license no.,rating & date of validity for alternator. Confirmation regarding COP certificate of DG Sets from an authorized agency for emission norms for each model of engine quoted, to D(QA) at the time of inspection. Make/Model/RPM of alternator

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKEUTOPIA/KIRLOSKAR/AS PER DGS&D NORMS

NIL CONFIRMED

Attached Attached CONFIRMED

TRIDENT-BRAND KIRLOSKAR GREENKG164H/DGS&D TYPE TESTED/1500

QUESTIONNAIRE DIESEL GENERATING SET WITH MANUAL CONTROL PANEL S.no 1 1.01

Item Description Diesel Generating Sets Guaranteed Technical Particulars (GTP) of DG Sets (To be furnished by tenderers for each quoted item separately)

1.02 1.03 1.04 1.05

Name of DG Set Manufacturer Electro Equipments Model number SEKG10AS5 Rated power output and duty cycle 10 KVA, CONTINUOUS Rated voltage, current, power factor and 240V, 41.7A, 0.8PF, 50HZ frequency Voltage regulation VG-1 or Better GRADE UPTO 82.5KVA AND VG-3 GRADE ABOVE 82.5 KVA Maximum temperature rise above ambient AS PER INSULATION (for engine) Class of insulation H or BETTER Efficiency of the alternator AS PER MANUFACTURER TYPE TEST CERTIFICATE Speed of revolution (RPM) at no load and 1500 RPM+ 4.5% rated voltage Type of excitation and excitation voltage SELF EXCITED Ambient conditions for which the DG set is AS PER IS suitable Type of enclosure SPDP Type of loads for which the genset is suitable 0.8 POWER FACTOR (LAG)

1.06 1.07 1.08 1.09 1.1 1.11 1.12 1.13 1.14 1.15 2.01 2.02 2.03

2.04 2.05

2.06 2.07

Maximum load that can be switched on or off and voltage drop/rise permitted Engine model number & manufacturer Type of cooling Fuel tank capacity (it shall be suitable for 12 hours minimum at rated load and at continuous operation) Total fuel consumption in liters/Kwh Rated engine power and the ambient conditions at which rated power is defined Other standard fittings of the engine to be specified by the tenderers Specific fuel consumption (in gms/kwh)

Item No.29 M/s Electro Equipments Furnished Below

FULL LOAD, AS PER IS STANDARD EA16 / KIRLOSKAR AIR COOLED SUITABLE FOR MINIMUM 12 HRS.

AS PER MANUFACTURER 16 BHP, AT STANDARD CONDITIONS

AS PER MANUFACTURER 235 gms/kw-hr/ AS PER IS 10000

3.01 4 5

6

Dry weight of the DG Set with canopy Maximum continuous operating time at rated load Peak power output and the duration for which the DG set can deliver this output

850 kg approx AS PER RELAVENT IS STANDARD AS APPLICABLE 10% OVERLOAD FOR 1 HR FOR EVERY 11HRS CONTINUOUS RUNNING AT RATED LOAD. Manual control panel with composite digital CLASS 1 OR AS PER SPECIFICATION, display meter, make, class & range for SUITABLE RANGE, MAKEmeasurement of voltage, current, pf, CONZERVE/SECURE/AE/L&T/INDOTECH/ frequency, kwh. HPL/ NIPPEN/ AS PER DGS&D NORMS

7

Microprocessor based AMF control panel with composite digital display meter, make, class & range for measurement of voltage,current, pf, frequency, kwh.

8

Submission of valid and renewed COP Attached certificate of DG Set from an authorized certification agency. Submission of valid and renewed TAC CONFIRMED certificate of DG set from an authorized certification agency. Vibration level maximum AS PER IS:8528-9 Type of coupling and mounting details CLOSED COUPLED OR DIAPHRAGM COUPLING AS PER ENGINE MANUFACTURE STANDARD

9

10 11

12 13

14 15 16

17

Deviation in the generator specification from IS specification, if any. Confirmation regarding submission of copy of type approval certificate form an authorized agency for emission norms for each model of engine quoted to D(QA) at the time of inspection. Valid BIS license no.,rating & date of validity for engine. Valid BIS license no.,rating & date of validity for alternator. Confirmation regarding COP certificate of DG Sets from an authorized agency for emission norms for each model of engine quoted, to D(QA) at the time of inspection. Make/Model/RPM of alternator

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKEUTOPIA/KIRLOSKAR/AS PER DGS&D NORMS

NIL CONFIRMED

Attached Attached CONFIRMED

TRIDENT-BRAND KIRLOSKAR GREENKG164J/DGS&D TYPE TESTED/1500

QUESTIONNAIRE DIESEL GENERATING SET WITH MANUAL CONTROL PANEL S.no 1 1.01

Item Description Diesel Generating Sets Guaranteed Technical Particulars (GTP) of DG Sets (To be furnished by tenderers for each quoted item separately)

1.02 1.03 1.04 1.05

Name of DG Set Manufacturer Electro Equipments Model number KG15AS4 Rated power output and duty cycle 15 KVA, CONTINUOUS Rated voltage, current, power factor and 240V, 62.5A, 0.8PF, 50HZ frequency Voltage regulation VG-1 or Better GRADE UPTO 82.5KVA AND VG-3 GRADE ABOVE 82.5 KVA Maximum temperature rise above ambient AS PER INSULATION (for engine) Class of insulation H or BETTER Efficiency of the alternator AS PER MANUFACTURER TYPE TEST CERTIFICATE Speed of revolution (RPM) at no load and 1500 RPM+4.5% rated voltage Type of excitation and excitation voltage SELF EXCITED Ambient conditions for which the DG set is AS PER IS suitable Type of enclosure SPDP Type of loads for which the genset is suitable 0.8 POWER FACTOR (LAG)

1.06 1.07 1.08 1.09 1.1 1.11 1.12 1.13 1.14 1.15 2.01 2.02 2.03

2.04 2.05

2.06 2.07

Item No.30 M/s Electro Equipments Furnished Below

Maximum load that can be switched on or off FULL LOAD, AS PER IS STANDARD and voltage drop/rise permitted Engine model number & manufacturer HA294 SR III / KIRLOSKAR Type of cooling AIR COOLED Fuel tank capacity (it shall be suitable for 12 SUITABLE FOR MINIMUM12 HRS. hours minimum at rated load and at continuous operation) Total fuel consumption in liters/Kwh AS PER MANUFACTURER Rated engine power and the ambient 20.5 BHP, AT STANDARD CONDITIONS conditions at which rated power is defined Other standard fittings of the engine to be specified by the tenderers Specific fuel consumption (in gms/kwh)

AS PER MANUFACTURER 242 GMS/KW-HR/AS PER IS 10000

3.01 4 5

6

Dry weight of the DG Set with canopy Maximum continuous operating time at rated load Peak power output and the duration for which the DG set can deliver this output

900 KG APPROX AS PER RELAVENT IS/BS STANDARD AS APPLICABLE 10% OVERLOAD FOR 1 HR FOR EVERY 11HRS CONTINUOUS RUNNING AT RATED LOAD. Manual control panel with composite digital CLASS 1 OR AS PER SPECIFICATION, display meter, make, class & range for SUITABLE RANGE, MAKEmeasurement of voltage, current, pf, CONZERVE/SECURE/AE/L&T/INDOTECH/ frequency, kwh. HPL/ NIPPEN/ AS PER DGS&D NORMS

7

Microprocessor based AMF control panel with composite digital display meter, make, class & range for measurement of voltage,current, pf, frequency, kwh.

8

Submission of valid and renewed COP Attached certificate of DG Set from an authorized certification agency. Submission of valid and renewed TAC CONFIRMED certificate of DG set from an authorized certification agency. Vibration level maximum AS PER IS:8528-9 Type of coupling and mounting details CLOSED COUPLED OR DIAPHRAGM COUPLING AS PER ENGINE MANUFACTURE STANDARD

9

10 11

12 13

14 15 16

17

Deviation in the generator specification from IS specification, if any. Confirmation regarding submission of copy of type approval certificate form an authorized agency for emission norms for each model of engine quoted to D(QA) at the time of inspection. Valid BIS license no.,rating & date of validity for engine. Valid BIS license no.,rating & date of validity for alternator. Confirmation regarding COP certificate of DG Sets from an authorized agency for emission norms for each model of engine quoted, to D(QA) at the time of inspection. Make/Model/RPM of alternator

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKEUTOPIA/KIRLOSKAR/AS PER DGS&D NORMS

NIL CONFIRMED

Attached Attached CONFIRMED

TRIDENT-BRAND KIRLOSKAR GREENKG184B/DGS&D TYPE TESTED/1500

QUESTIONNAIRE DIESEL GENERATING SET WITH MANUAL CONTROL PANEL S.no 1 1.01

Item Description Diesel Generating Sets Guaranteed Technical Particulars (GTP) of DG Sets (To be furnished by tenderers for each quoted item separately)

1.02 1.03 1.04 1.05

Name of DG Set Manufacturer Electro Equipments Model number SEKG15AS6 Rated power output and duty cycle 15 KVA, CONTINUOUS Rated voltage, current, power factor and 240V, 62.5A, 0.8PF, 50HZ frequency Voltage regulation VG-1 or Better GRADE UPTO 82.5KVA AND VG-3 GRADE ABOVE 82.5 KVA Maximum temperature rise above ambient AS PER INSULATION (for engine) Class of insulation H or BETTER Efficiency of the alternator AS PER MANUFACTURER TYPE TEST CERTIFICATE Speed of revolution (RPM) at no load and 1500 RPM+4.5% rated voltage Type of excitation and excitation voltage SELF EXCITED Ambient conditions for which the DG set is AS PER IS suitable Type of enclosure SPDP Type of loads for which the genset is suitable 0.8 POWER FACTOR (LAG)

1.06 1.07 1.08 1.09 1.1 1.11 1.12 1.13 1.14 1.15 2.01 2.02 2.03

2.04 2.05

2.06 2.07

Maximum load that can be switched on or off and voltage drop/rise permitted Engine model number & manufacturer Type of cooling Fuel tank capacity (it shall be suitable for 12 hours minimum at rated load and at continuous operation) Total fuel consumption in liters/Kwh Rated engine power and the ambient conditions at which rated power is defined

Item No. 30A M/s Electro Equipments Furnished Below

FULL LOAD, AS PER IS STANDARD EA20 / KIRLOSKAR AIR COOLED SUITABLE FOR MINIMUM12 HRS.

AS PER MANUFACTURER 20 BHP, AT STANDARD CONDITIONS

Other standard fittings of the engine to be AS PER MANUFACTURER specified by the tenderers Specific fuel consumption (in gms/kwh) 242 GMS/KW-HR/AS PER IS 10000

3.01 4 5

6

Dry weight of the DG Set with canopy Maximum continuous operating time at rated load Peak power output and the duration for which the DG set can deliver this output

900 KG APPROX AS PER RELAVENT IS/BS STANDARD AS APPLICABLE 10% OVERLOAD FOR 1 HR FOR EVERY 11HRS CONTINUOUS RUNNING AT RATED LOAD. Manual control panel with composite digital CLASS 1 OR AS PER SPECIFICATION, display meter, make, class & range for SUITABLE RANGE, MAKEmeasurement of voltage, current, pf, CONZERVE/SECURE/AE/L&T/INDOTECH/ frequency, kwh. HPL/ NIPPEN/ AS PER DGS&D NORMS

7

Microprocessor based AMF control panel with composite digital display meter, make, class & range for measurement of voltage,current, pf, frequency, kwh.

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKEUTOPIA/KIRLOSKAR/AS PER DGS&D NORMS

8

Submission of valid and renewed COP certificate of DG Set from an authorized certification agency. Submission of valid and renewed TAC certificate of DG set from an authorized certification agency. Vibration level maximum Type of coupling and mounting details

Attached

9

10 11

12 13

14 15 16

17

Deviation in the generator specification from IS specification, if any. Confirmation regarding submission of copy of type approval certificate form an authorized agency for emission norms for each model of engine quoted to D(QA) at the time of inspection. Valid BIS license no.,rating & date of validity for engine. Valid BIS license no.,rating & date of validity for alternator. Confirmation regarding COP certificate of DG Sets from an authorized agency for emission norms for each model of engine quoted, to D(QA) at the time of inspection. Make/Model/RPM of alternator

CONFIRMED

AS PER IS:8528-9 CLOSED COUPLED OR DIAPHRAGM COUPLING AS PER ENGINE MANUFACTURE STANDARD NIL CONFIRMED

Attached Attached CONFIRMED

TRIDENT-BRAND KIRLOSKAR GREENKG164J/DGS&D TYPE TESTED/1500

QUESTIONNAIRE DIESEL GENERATING SET WITH MANUAL CONTROL PANEL S.no 1 1.01

Item Description Diesel Generating Sets Guaranteed Technical Particulars (GTP) of DG Sets (To be furnished by tenderers for each quoted item separately)

1.02 1.03 1.04 1.05

Name of DG Set Manufacturer Electro Equipments Model number KG25AS-C Rated power output and duty cycle 20 KVA, CONTINUOUS Rated voltage, current, power factor and 240V, 83.3A, 0.8PF, 50HZ frequency Voltage regulation VG-1 or Better GRADE UPTO 82.5KVA AND VG-3 GRADE ABOVE 82.5 KVA Maximum temperature rise above ambient AS PER INSULATION (for engine) Class of insulation H or BETTER Efficiency of the alternator AS PER MANUFACTURER TYPE TEST CERTIFICATE Speed of revolution (RPM) at no load and 1500 RPM +4.5% rated voltage Type of excitation and excitation voltage SELF EXCITED Ambient conditions for which the DG set is AS PER IS suitable Type of enclosure SPDP Type of loads for which the genset is suitable 0.8 POWER FACTOR (LAG)

1.06 1.07 1.08 1.09 1.1 1.11 1.12 1.13 1.14 1.15 2.01 2.02 2.03

2.04 2.05

2.06 2.07

Maximum load that can be switched on or off and voltage drop/rise permitted Engine model number & manufacturer Type of cooling Fuel tank capacity (it shall be suitable for 12 hours minimum at rated load and at continuous operation) Total fuel consumption in liters/Kwh Rated engine power and the ambient conditions at which rated power is defined Other standard fittings of the engine to be specified by the tenderers Specific fuel consumption (in gms/kwh)

Item No.31 M/s Electro Equipments Furnished Below

FULL LOAD, AS PER IS STANDARD HA394/ KIRLOSKAR AIR COOLED SUITABLE FOR MINIMUM12 HRS.

AS PER MANUFACTURER 32 BHP, AT STANDARD CONDITIONS

AS PER MANUFACTURER 174 GMS/HP-HR/AS PER IS 10000

3.01 4 5

6

Dry weight of the DG Set with canopy Maximum continuous operating time at rated load Peak power output and the duration for which the DG set can deliver this output

1050 KG APPROX AS PER RELAVENT IS/BS STANDARD AS APPLICABLE 10% OVERLOAD FOR 1 HR FOR EVERY 11HRS CONTINUOUS RUNNING AT RATED LOAD. Manual control panel with composite digital CLASS 1 OR AS PER SPECIFICATION, display meter, make, class & range for SUITABLE RANGE, MAKEmeasurement of voltage, current, pf, CONZERVE/SECURE/AE/L&T/INDOTECH/ frequency, kwh. HPL/ NIPPEN/ AS PER DGS&D NORMS

7

Microprocessor based AMF control panel with composite digital display meter, make, class & range for measurement of voltage,current, pf, frequency, kwh.

8

Submission of valid and renewed COP ATTACHED certificate of DG Set from an authorized certification agency. Submission of valid and renewed TAC CONFIRMED certificate of DG set from an authorized certification agency. Vibration level maximum AS PER IS:8528-9 Type of coupling and mounting details CLOSED COUPLED OR DIAPHRAGM COUPLING AS PER ENGINE MANUFACTURE STANDARD

9

10 11

12 13

14 15 16

17

Deviation in the generator specification from IS specification, if any. Confirmation regarding submission of copy of type approval certificate form an authorized agency for emission norms for each model of engine quoted to D(QA) at the time of inspection. Valid BIS license no.,rating & date of validity for engine. Valid BIS license no.,rating & date of validity for alternator. Confirmation regarding COP certificate of DG Sets from an authorized agency for emission norms for each model of engine quoted, to D(QA) at the time of inspection. Make/Model/RPM of alternator

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKEUTOPIA/KIRLOSKAR/AS PER DGS&D NORMS

NIL CONFIRMED

N.A N.A CONFIRMED

TRIDENT-BRAND KIRLOSKAR GREENKG184D/DGS&D TYPE TESTED/1500

QUESTIONNAIRE DIESEL GENERATING SET WITH MANUAL CONTROL PANEL S.no 1 1.01

Item Description Diesel Generating Sets Guaranteed Technical Particulars (GTP) of DG Sets (To be furnished by tenderers for each quoted item separately)

1.02 1.03 1.04 1.05

Name of DG Set Manufacturer Electro Equipments Model number KG7.5WS Rated power output and duty cycle 7.5 KVA, CONTINUOUS Rated voltage, current, power factor and 240V, 31.3A, 0.8PF, 50HZ frequency Voltage regulation VG-1 or Better GRADE UPTO 82.5KVA AND VG-3 GRADE ABOVE 82.5 KVA Maximum temperature rise above ambient AS PER INSULATION (for engine) Class of insulation H or BETTER Efficiency of the alternator AS PER MANUFACTURER TYPE TEST CERTIFICATE Speed of revolution (RPM) at no load and 1500 RPM+ 4.5% rated voltage Type of excitation and excitation voltage SELF EXCITED Ambient conditions for which the DG set is AS PER IS suitable Type of enclosure SPDP Type of loads for which the genset is suitable 0.8 POWER FACTOR (LAG)

1.06 1.07 1.08 1.09 1.1 1.11 1.12 1.13 1.14 1.15 2.01 2.02 2.03

2.04 2.05

2.06 2.07

Maximum load that can be switched on or off and voltage drop/rise permitted Engine model number & manufacturer Type of cooling Fuel tank capacity (it shall be suitable for 12 hours minimum at rated load and at continuous operation) Total fuel consumption in liters/Kwh Rated engine power and the ambient conditions at which rated power is defined Other standard fittings of the engine to be specified by the tenderers Specific fuel consumption (in gms/kwh)

Item No.33 M/s Electro Equipments Furnished Below

FULL LOAD, AS PER IS STANDARD EW14/ KIRLOSKAR WATER COOLED SUITABLE FOR MINIMUM 12 HRS.

AS PER MANUFACTURER 14 BHP, AT STANDARD CONDITIONS

AS PER MANUFACTURER 230 GMS/KW-HR/AS PER IS10000

3.01 4 5

6

Dry weight of the DG Set with canopy Maximum continuous operating time at rated load Peak power output and the duration for which the DG set can deliver this output

850 KG APPROX AS PER RELAVENT IS/BS STANDARD AS APPLICABLE 10% OVERLOAD FOR 1 HR FOR EVERY 11HRS CONTINUOUS RUNNING AT RATED LOAD. Manual control panel with composite digital CLASS 1 OR AS PER SPECIFICATION, display meter, make, class & range for SUITABLE RANGE, MAKEmeasurement of voltage, current, pf, CONZERVE/SECURE/AE/L&T/INDOTECH/ frequency, kwh. HPL/ NIPPEN/ AS PER DGS&D NORMS

7

Microprocessor based AMF control panel with composite digital display meter, make, class & range for measurement of voltage,current, pf, frequency, kwh.

8

Submission of valid and renewed COP ATTACHED certificate of DG Set from an authorized certification agency. Submission of valid and renewed TAC CONFIRMED certificate of DG set from an authorized certification agency. Vibration level maximum AS PER IS:8528-9 Type of coupling and mounting details CLOSED COUPLED OR DIAPHRAGM COUPLING AS PER ENGINE MANUFACTURE STANDARD

9

10 11

12 13

14 15 16

17

Deviation in the generator specification from IS specification, if any. Confirmation regarding submission of copy of type approval certificate form an authorized agency for emission norms for each model of engine quoted to D(QA) at the time of inspection. Valid BIS license no.,rating & date of validity for engine. Valid BIS license no.,rating & date of validity for alternator. Confirmation regarding COP certificate of DG Sets from an authorized agency for emission norms for each model of engine quoted, to D(QA) at the time of inspection. Make/Model/RPM of alternator

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKEUTOPIA/KIRLOSKAR/AS PER DGS&D NORMS

NIL CONFIRMED

ATTACHED ATTACHED CONFIRMED

TRIDENT-BRAND KIRLOSKAR GREENKG164H/DGS&D TYPE TESTED/1500

QUESTIONNAIRE DIESEL GENERATING SET WITH MANUAL CONTROL PANEL S.no 1 1.01

Item Description Diesel Generating Sets Guaranteed Technical Particulars (GTP) of DG Sets (To be furnished by tenderers for each quoted item separately)

1.02 1.03 1.04 1.05

Name of DG Set Manufacturer Electro Equipments Model number KG10WS Rated power output and duty cycle 10 KVA, CONTINUOUS Rated voltage, current, power factor and 240V, 41.7A, 0.8PF, 50HZ frequency Voltage regulation VG-1 or Better GRADE UPTO 82.5KVA AND VG-3 GRADE ABOVE 82.5 KVA Maximum temperature rise above ambient AS PER INSULATION (for engine) Class of insulation H or BETTER Efficiency of the alternator AS PER MANUFACTURER TYPE TEST CERTIFICATE Speed of revolution (RPM) at no load and 1500 RPM+ 4.5% rated voltage Type of excitation and excitation voltage SELF EXCITED Ambient conditions for which the DG set is AS PER IS suitable Type of enclosure SPDP Type of loads for which the genset is suitable 0.8 POWER FACTOR (LAG)

1.06 1.07 1.08 1.09 1.1 1.11 1.12 1.13 1.14 1.15 2.01 2.02 2.03

2.04 2.05

2.06 2.07

Maximum load that can be switched on or off and voltage drop/rise permitted Engine model number & manufacturer Type of cooling Fuel tank capacity (it shall be suitable for 12 hours minimum at rated load and at continuous operation) Total fuel consumption in liters/Kwh Rated engine power and the ambient conditions at which rated power is defined Other standard fittings of the engine to be specified by the tenderers Specific fuel consumption (in gms/kwh)

Item No.34 M/s Electro Equipments Furnished Below

FULL LOAD, AS PER IS STANDARD EW14/ KIRLOSKAR WATER COOLED SUITABLE FOR MINIMUM 12 HRS.

AS PER MANUFACTURER 14 BHP, AT STANDARD CONDITIONS

AS PER MANUFACTURER 230 GMS/KW-HR/AS PER IS10000

3.01 4 5

6

Dry weight of the DG Set with canopy Maximum continuous operating time at rated load Peak power output and the duration for which the DG set can deliver this output

850 KG APPROX AS PER RELAVENT IS/BS STANDARD AS APPLICABLE 10% OVERLOAD FOR 1 HR FOR EVERY 11HRS CONTINUOUS RUNNING AT RATED LOAD. Manual control panel with composite digital CLASS 1 OR AS PER SPECIFICATION, display meter, make, class & range for SUITABLE RANGE, MAKEmeasurement of voltage, current, pf, CONZERVE/SECURE/AE/L&T/INDOTECH/ frequency, kwh. HPL/ NIPPEN/ AS PER DGS&D NORMS

7

Microprocessor based AMF control panel with composite digital display meter, make, class & range for measurement of voltage,current, pf, frequency, kwh.

8

Submission of valid and renewed COP ATTACHED certificate of DG Set from an authorized certification agency. Submission of valid and renewed TAC CONFIRMED certificate of DG set from an authorized certification agency. Vibration level maximum AS PER IS:8528-9 Type of coupling and mounting details CLOSED COUPLED OR DIAPHRAGM COUPLING AS PER ENGINE MANUFACTURE STANDARD

9

10 11

12 13

14 15 16

17

Deviation in the generator specification from IS specification, if any. Confirmation regarding submission of copy of type approval certificate form an authorized agency for emission norms for each model of engine quoted to D(QA) at the time of inspection. Valid BIS license no.,rating & date of validity for engine. Valid BIS license no.,rating & date of validity for alternator. Confirmation regarding COP certificate of DG Sets from an authorized agency for emission norms for each model of engine quoted, to D(QA) at the time of inspection. Make/Model/RPM of alternator

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKEUTOPIA/KIRLOSKAR/AS PER DGS&D NORMS

NIL CONFIRMED

ATTACHED ATTACHED CONFIRMED

TRIDENT-BRAND KIRLOSKAR GREENKG164J/DGS&D TYPE TESTED/1500

QUESTIONNAIRE DIESEL GENERATING SET WITH MANUAL CONTROL PANEL S.no 1 1.01

Item Description Diesel Generating Sets Guaranteed Technical Particulars (GTP) of DG Sets (To be furnished by tenderers for each quoted item separately)

1.02 1.03 1.04 1.05

Name of DG Set Manufacturer Electro Equipments Model number SEKG10AS5 Rated power output and duty cycle 10 KVA, CONTINUOUS Rated voltage, current, power factor and 415V, 13.9A, 0.8PF, 50HZ frequency Voltage regulation VG-1 or Better GRADE UPTO 82.5KVA AND VG-3 GRADE ABOVE 82.5 KVA Maximum temperature rise above ambient AS PER INSULATION (for engine) Class of insulation H or BETTER Efficiency of the alternator AS PER MANUFACTURER TYPE TEST CERTIFICATE Speed of revolution (RPM) at no load and 1500 RPM+ 4.5% rated voltage Type of excitation and excitation voltage SELF EXCITED Ambient conditions for which the DG set is AS PER IS suitable Type of enclosure SPDP Type of loads for which the genset is suitable 0.8 POWER FACTOR (LAG)

1.06 1.07 1.08 1.09 1.1 1.11 1.12 1.13 1.14 1.15 2.01 2.02 2.03

2.04 2.05

2.06 2.07

Maximum load that can be switched on or off and voltage drop/rise permitted Engine model number & manufacturer Type of cooling Fuel tank capacity (it shall be suitable for 12 hours minimum at rated load and at continuous operation) Total fuel consumption in liters/Kwh Rated engine power and the ambient conditions at which rated power is defined Other standard fittings of the engine to be specified by the tenderers Specific fuel consumption (in gms/kwh)

Item No.37 M/s Elmech Engineers Furnished Below

FULL LOAD, AS PER IS STANDARD EA16/ KIRLOSKAR AIR COOLED SUITABLE FOR MINIMUM 12 HRS.

AS PER MANUFACTURER 16 BHP, AT STANDARD CONDITIONS

AS PER MANUFACTURER 235 gms/kw-hr/ AS PER IS 10000

3.01 4 5

6

Dry weight of the DG Set with canopy Maximum continuous operating time at rated load Peak power output and the duration for which the DG set can deliver this output

850 KG APPROX AS PER RELAVENT IS/BS STANDARD AS APPLICABLE 10% OVERLOAD FOR 1 HR FOR EVERY 11HRS CONTINUOUS RUNNING AT RATED LOAD. Manual control panel with composite digital CLASS 1 OR AS PER SPECIFICATION, display meter, make, class & range for SUITABLE RANGE, MAKEmeasurement of voltage, current, pf, CONZERVE/SECURE/AE/L&T/INDOTECH/ frequency, kwh. HPL/ NIPPEN/ AS PER DGS&D NORMS

7

Microprocessor based AMF control panel with composite digital display meter, make, class & range for measurement of voltage,current, pf, frequency, kwh.

8

Submission of valid and renewed COP ATTACHED certificate of DG Set from an authorized certification agency. Submission of valid and renewed TAC CONFIRMED certificate of DG set from an authorized certification agency. Vibration level maximum AS PER IS:8528-9 Type of coupling and mounting details CLOSED COUPLED OR DIAPHRAGM COUPLING AS PER ENGINE MANUFACTURE STANDARD

9

10 11

12 13

14 15 16

17

Deviation in the generator specification from IS specification, if any. Confirmation regarding submission of copy of type approval certificate form an authorized agency for emission norms for each model of engine quoted to D(QA) at the time of inspection. Valid BIS license no.,rating & date of validity for engine. Valid BIS license no.,rating & date of validity for alternator. Confirmation regarding COP certificate of DG Sets from an authorized agency for emission norms for each model of engine quoted, to D(QA) at the time of inspection. Make/Model/RPM of alternator

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKEUTOPIA/KIRLOSKAR/AS PER DGS&D NORMS

NIL CONFIRMED

ATTACHED ATTACHED CONFIRMED

TRIDENT-BRAND KIRLOSKAR GREENKG164G/DGS&D TYPE TESTED/1500

QUESTIONNAIRE DIESEL GENERATING SET WITH MANUAL CONTROL PANEL S.no 1 1.01

Item Description Diesel Generating Sets Guaranteed Technical Particulars (GTP) of DG Sets (To be furnished by tenderers for each quoted item separately)

1.02 1.03 1.04 1.05

Name of DG Set Manufacturer Electro Equipments Model number KG15AS4 Rated power output and duty cycle 15 KVA, CONTINUOUS Rated voltage, current, power factor and 415V, 20.9A, 0.8PF, 50HZ frequency Voltage regulation VG-1 or Better GRADE UPTO 82.5KVA AND VG-3 GRADE ABOVE 82.5 KVA Maximum temperature rise above ambient AS PER INSULATION (for engine) Class of insulation H or BETTER Efficiency of the alternator AS PER MANUFACTURER TYPE TEST CERTIFICATE Speed of revolution (RPM) at no load and 1500 RPM+ 4.5% rated voltage Type of excitation and excitation voltage SELF EXCITED Ambient conditions for which the DG set is AS PER IS suitable Type of enclosure SPDP Type of loads for which the genset is suitable 0.8 POWER FACTOR (LAG)

1.06 1.07 1.08 1.09 1.1 1.11 1.12 1.13 1.14 1.15 2.01 2.02 2.03

2.04 2.05

2.06 2.07

Item No.38 M/s Electro Equipments Furnished Below

Maximum load that can be switched on or off FULL LOAD, AS PER IS STANDARD and voltage drop/rise permitted Engine model number & manufacturer HA294 SR III/ KIRLOSKAR Type of cooling AIR COOLED Fuel tank capacity (it shall be suitable for 12 SUITABLE FOR MINIMUM 12 HRS. hours minimum at rated load and at continuous operation) Total fuel consumption in liters/Kwh AS PER MANUFACTURER Rated engine power and the ambient 20.5 BHP, AT STANDARD CONDITIONS conditions at which rated power is defined Other standard fittings of the engine to be specified by the tenderers Specific fuel consumption (in gms/kwh)

AS PER MANUFACTURER 242 GMS/KW-HR/AS PER IS 10000

3.01 4 5

6

Dry weight of the DG Set with canopy Maximum continuous operating time at rated load Peak power output and the duration for which the DG set can deliver this output

900 KG APPROX AS PER RELAVENT IS/BS STANDARD AS APPLICABLE 10% OVERLOAD FOR 1 HR FOR EVERY 11HRS CONTINUOUS RUNNING AT RATED LOAD. Manual control panel with composite digital CLASS 1 OR AS PER SPECIFICATION, display meter, make, class & range for SUITABLE RANGE, MAKEmeasurement of voltage, current, pf, CONZERVE/SECURE/AE/L&T/INDOTECH/ frequency, kwh. HPL/ NIPPEN/ AS PER DGS&D NORMS

7

Microprocessor based AMF control panel with composite digital display meter, make, class & range for measurement of voltage,current, pf, frequency, kwh.

8

Submission of valid and renewed COP ATTACHED certificate of DG Set from an authorized certification agency. Submission of valid and renewed TAC CONFIRMED certificate of DG set from an authorized certification agency. Vibration level maximum AS PER IS:8528-9 Type of coupling and mounting details CLOSED COUPLED OR DIAPHRAGM COUPLING AS PER ENGINE MANUFACTURE STANDARD

9

10 11

12 13

14 15 16

17

Deviation in the generator specification from IS specification, if any. Confirmation regarding submission of copy of type approval certificate form an authorized agency for emission norms for each model of engine quoted to D(QA) at the time of inspection. Valid BIS license no.,rating & date of validity for engine. Valid BIS license no.,rating & date of validity for alternator. Confirmation regarding COP certificate of DG Sets from an authorized agency for emission norms for each model of engine quoted, to D(QA) at the time of inspection. Make/Model/RPM of alternator

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKEUTOPIA/KIRLOSKAR/AS PER DGS&D NORMS

NIL CONFIRMED

ATTACHED ATTACHED CONFIRMED

TRIDENT-BRAND KIRLOSKAR GREENKG164J/DGS&D TYPE TESTED/1500

QUESTIONNAIRE DIESEL GENERATING SET WITH MANUAL CONTROL PANEL S.no 1 1.01

Item Description Diesel Generating Sets Guaranteed Technical Particulars (GTP) of DG Sets (To be furnished by tenderers for each quoted item separately)

1.02 1.03 1.04 1.05

Name of DG Set Manufacturer Electro Equipments Model number SEKG15AS6 Rated power output and duty cycle 15 KVA, CONTINUOUS Rated voltage, current, power factor and 240V, 62.5A, 0.8PF, 50HZ frequency Voltage regulation VG-1 or Better GRADE UPTO 82.5KVA AND VG-3 GRADE ABOVE 82.5 KVA Maximum temperature rise above ambient AS PER INSULATION (for engine) Class of insulation H or BETTER Efficiency of the alternator AS PER MANUFACTURER TYPE TEST CERTIFICATE Speed of revolution (RPM) at no load and 1500 RPM+4.5% rated voltage Type of excitation and excitation voltage SELF EXCITED Ambient conditions for which the DG set is AS PER IS suitable Type of enclosure SPDP Type of loads for which the genset is suitable 0.8 POWER FACTOR (LAG)

1.06 1.07 1.08 1.09 1.1 1.11 1.12 1.13 1.14 1.15 2.01 2.02 2.03

2.04 2.05

2.06 2.07

Maximum load that can be switched on or off and voltage drop/rise permitted Engine model number & manufacturer Type of cooling Fuel tank capacity (it shall be suitable for 12 hours minimum at rated load and at continuous operation) Total fuel consumption in liters/Kwh Rated engine power and the ambient conditions at which rated power is defined

Item No. 38A M/s Electro Equipments Furnished Below

FULL LOAD, AS PER IS STANDARD EA20 / KIRLOSKAR AIR COOLED SUITABLE FOR MINIMUM12 HRS.

AS PER MANUFACTURER 20 BHP, AT STANDARD CONDITIONS

Other standard fittings of the engine to be AS PER MANUFACTURER specified by the tenderers Specific fuel consumption (in gms/kwh) 242 GMS/KW-HR/AS PER IS 10000

3.01 4 5

6

Dry weight of the DG Set with canopy Maximum continuous operating time at rated load Peak power output and the duration for which the DG set can deliver this output

900 KG APPROX AS PER RELAVENT IS/BS STANDARD AS APPLICABLE 10% OVERLOAD FOR 1 HR FOR EVERY 11HRS CONTINUOUS RUNNING AT RATED LOAD. Manual control panel with composite digital CLASS 1 OR AS PER SPECIFICATION, display meter, make, class & range for SUITABLE RANGE, MAKEmeasurement of voltage, current, pf, CONZERVE/SECURE/AE/L&T/INDOTECH/ frequency, kwh. HPL/ NIPPEN/ AS PER DGS&D NORMS

7

Microprocessor based AMF control panel with composite digital display meter, make, class & range for measurement of voltage,current, pf, frequency, kwh.

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKEUTOPIA/KIRLOSKAR/AS PER DGS&D NORMS

8

Submission of valid and renewed COP certificate of DG Set from an authorized certification agency. Submission of valid and renewed TAC certificate of DG set from an authorized certification agency. Vibration level maximum Type of coupling and mounting details

Attached

9

10 11

12 13

14 15 16

17

Deviation in the generator specification from IS specification, if any. Confirmation regarding submission of copy of type approval certificate form an authorized agency for emission norms for each model of engine quoted to D(QA) at the time of inspection. Valid BIS license no.,rating & date of validity for engine. Valid BIS license no.,rating & date of validity for alternator. Confirmation regarding COP certificate of DG Sets from an authorized agency for emission norms for each model of engine quoted, to D(QA) at the time of inspection. Make/Model/RPM of alternator

CONFIRMED

AS PER IS:8528-9 CLOSED COUPLED OR DIAPHRAGM COUPLING AS PER ENGINE MANUFACTURE STANDARD NIL CONFIRMED

Attached Attached CONFIRMED

TRIDENT-BRAND KIRLOSKAR GREENKG164J/DGS&D TYPE TESTED/1500

QUESTIONNAIRE DIESEL GENERATING SET WITH MANUAL CONTROL PANEL S.no 1 1.01

Item Description Diesel Generating Sets Guaranteed Technical Particulars (GTP) of DG Sets (To be furnished by tenderers for each quoted item separately)

1.02 1.03 1.04 1.05

Name of DG Set Manufacturer Electro Equipments Model number KG25AS-C Rated power output and duty cycle 20 KVA, CONTINUOUS Rated voltage, current, power factor and 415V, 27.8A, 0.8PF, 50HZ frequency Voltage regulation VG-1 or Better GRADE UPTO 82.5KVA AND VG-3 GRADE ABOVE 82.5 KVA Maximum temperature rise above ambient AS PER INSULATION (for engine) Class of insulation H or BETTER Efficiency of the alternator AS PER MANUFACTURER TYPE TEST CERTIFICATE Speed of revolution (RPM) at no load and 1500 RPM + 4.5% rated voltage Type of excitation and excitation voltage SELF EXCITED Ambient conditions for which the DG set is AS PER IS suitable Type of enclosure SPDP Type of loads for which the genset is suitable 0.8 POWER FACTOR (LAG)

1.06 1.07 1.08 1.09 1.1 1.11 1.12 1.13 1.14 1.15 2.01 2.02 2.03

2.04 2.05

2.06 2.07

Maximum load that can be switched on or off and voltage drop/rise permitted Engine model number & manufacturer Type of cooling Fuel tank capacity (it shall be suitable for 12 hours minimum at rated load and at continuous operation) Total fuel consumption in liters/Kwh Rated engine power and the ambient conditions at which rated power is defined Other standard fittings of the engine to be specified by the tenderers Specific fuel consumption (in gms/kwh)

Item No.39 M/s Electro Equipments Furnished Below

FULL LOAD, AS PER IS STANDARD HA394 / KIRLOSKAR AIR COOLED SUITABLE FOR MINIMUM 12 HRS.

AS PER MANUFACTURER 32 BHP, AT STANDARD CONDITIONS

AS PER MANUFACTURER 174 GMS/HP-HR/AS PER IS 10000

3.01 4 5

6

Dry weight of the DG Set with canopy Maximum continuous operating time at rated load Peak power output and the duration for which the DG set can deliver this output

1050 KG APPROX AS PER RELAVENT IS/BS STANDARD AS APPLICABLE 10% OVERLOAD FOR 1 HR FOR EVERY 11HRS CONTINUOUS RUNNING AT RATED LOAD. Manual control panel with composite digital CLASS 1 OR AS PER SPECIFICATION, display meter, make, class & range for SUITABLE RANGE, MAKEmeasurement of voltage, current, pf, CONZERVE/SECURE/AE/L&T/INDOTECH/ frequency, kwh. HPL/ NIPPEN/ AS PER DGS&D NORMS

7

Microprocessor based AMF control panel with composite digital display meter, make, class & range for measurement of voltage,current, pf, frequency, kwh.

8

Submission of valid and renewed COP ATTACHED certificate of DG Set from an authorized certification agency. Submission of valid and renewed TAC CONFIRMED certificate of DG set from an authorized certification agency. Vibration level maximum AS PER IS:8528-9 Type of coupling and mounting details CLOSED COUPLED OR DIAPHRAGM COUPLING AS PER ENGINE MANUFACTURE STANDARD

9

10 11

12 13

14 15 16

17

Deviation in the generator specification from IS specification, if any. Confirmation regarding submission of copy of type approval certificate form an authorized agency for emission norms for each model of engine quoted to D(QA) at the time of inspection. Valid BIS license no.,rating & date of validity for engine. Valid BIS license no.,rating & date of validity for alternator. Confirmation regarding COP certificate of DG Sets from an authorized agency for emission norms for each model of engine quoted, to D(QA) at the time of inspection. Make/Model/RPM of alternator

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKEUTOPIA/KIRLOSKAR/AS PER DGS&D NORMS

NIL CONFIRMED

N.A N.A CONFIRMED

TRIDENT-BRAND KIRLOSKAR GREENKG184A/DGS&D TYPE TESTED/1500

QUESTIONNAIRE DIESEL GENERATING SET WITH MANUAL CONTROL PANEL S.no 1 1.01

Item Description Diesel Generating Sets Guaranteed Technical Particulars (GTP) of DG Sets (To be furnished by tenderers for each quoted item separately)

1.02 1.03 1.04 1.05

Name of DG Set Manufacturer Electro Equipments Model number KG25AS-C Rated power output and duty cycle 25 KVA, CONTINUOUS Rated voltage, current, power factor and 240V, 34.8A, 0.8PF, 50HZ frequency Voltage regulation VG-1 or Better GRADE UPTO 82.5KVA AND VG-3 GRADE ABOVE 82.5 KVA Maximum temperature rise above ambient AS PER INSULATION (for engine) Class of insulation H or BETTER Efficiency of the alternator AS PER MANUFACTURER TYPE TEST CERTIFICATE Speed of revolution (RPM) at no load and 1500 RPM+4.5% rated voltage Type of excitation and excitation voltage SELF EXCITED Ambient conditions for which the DG set is AS PER IS suitable Type of enclosure ACOUSTIC Type of loads for which the genset is suitable 0.8 POWER FACTOR (LAG)

1.06 1.07 1.08 1.09 1.1 1.11 1.12 1.13 1.14 1.15 2.01 2.02 2.03

2.04 2.05

2.06 2.07

Maximum load that can be switched on or off and voltage drop/rise permitted Engine model number & manufacturer Type of cooling Fuel tank capacity (it shall be suitable for 12 hours minimum at rated load and at continuous operation) Total fuel consumption in liters/Kwh Rated engine power and the ambient conditions at which rated power is defined Other standard fittings of the engine to be specified by the tenderers Specific fuel consumption (in gms/kwh)

Item No.40 M/s Electro Equipments Furnished Below

FULL LOAD, AS PER IS STANDARD HA394 / KIRLOSKAR AIR COOLED SUITABLE FOR MINIMUM 12 HRS.

AS PER MANUFACTURER 32 BHP, AT STANDARD CONDITIONS

AS PER MANUFACTURER 174 GMS/HP-HR/ AS PER IS 10000

3.01 4 5

6

Dry weight of the DG Set with canopy Maximum continuous operating time at rated load Peak power output and the duration for which the DG set can deliver this output

1030 KG APPROX AS PER RELAVENT IS/BS STANDARD AS APPLICABLE 10% OVERLOAD FOR 1 HR FOR EVERY 11HRS CONTINUOUS RUNNING AT RATED LOAD. Manual control panel with composite digital CLASS 1 OR AS PER SPECIFICATION, display meter, make, class & range for SUITABLE RANGE, MAKEmeasurement of voltage, current, pf, CONZERVE/SECURE/AE/L&T/INDOTECH/ frequency, kwh. HPL/ NIPPEN/ AS PER DGS&D NORMS

7

Microprocessor based AMF control panel with composite digital display meter, make, class & range for measurement of voltage,current, pf, frequency, kwh.

8

Submission of valid and renewed COP ATTACHED certificate of DG Set from an authorized certification agency. Submission of valid and renewed TAC CONFIRMED certificate of DG set from an authorized certification agency. Vibration level maximum AS PER IS:8528-9 Type of coupling and mounting details CLOSED COUPLED OR DIAPHRAGM COUPLING AS PER ENGINE MANUFACTURE

9

10 11

12 13

14 15 16

17

Deviation in the generator specification from IS specification, if any. Confirmation regarding submission of copy of type approval certificate form an authorized agency for emission norms for each model of engine quoted to D(QA) at the time of inspection. Valid BIS license no.,rating & date of validity for engine. Valid BIS license no.,rating & date of validity for alternator. Confirmation regarding COP certificate of DG Sets from an authorized agency for emission norms for each model of engine quoted, to D(QA) at the time of inspection. Make/Model/RPM of alternator

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKEUTOPIA/KIRLOSKAR/AS PER DGS&D NORMS

NIL CONFIRMED

N.A N.A CONFIRMED

TRIDENT-BRAND KIRLOSKAR GREENKG184B/DGS&D TYPE TESTED/1500

QUESTIONNAIRE DIESEL GENERATING SET WITH MANUAL CONTROL PANEL S.no 1 1.01

Item Description Diesel Generating Sets Guaranteed Technical Particulars (GTP) of DG Sets (To be furnished by tenderers for each quoted item separately)

1.02 1.03 1.04 1.05

Name of DG Set Manufacturer Electro Equipments Model number KG35AS Rated power output and duty cycle 30 KVA, CONTINUOUS Rated voltage, current, power factor and 240V, 41.7A, 0.8PF, 50HZ frequency Voltage regulation VG-1 or Better GRADE UPTO 82.5KVA AND VG-3 GRADE ABOVE 82.5 KVA Maximum temperature rise above ambient AS PER INSULATION (for engine) Class of insulation H or BETTER Efficiency of the alternator AS PER MANUFACTURER TYPE TEST CERTIFICATE Speed of revolution (RPM) at no load and 1500 RPM +4.5% rated voltage Type of excitation and excitation voltage SELF EXCITED Ambient conditions for which the DG set is AS PER IS suitable Type of enclosure ACOUSTIC Type of loads for which the genset is suitable 0.8 POWER FACTOR (LAG)

1.06 1.07 1.08 1.09 1.1 1.11 1.12 1.13 1.14 1.15 2.01 2.02 2.03

2.04 2.05

2.06 2.07

Maximum load that can be switched on or off and voltage drop/rise permitted Engine model number & manufacturer Type of cooling Fuel tank capacity (it shall be suitable for 12 hours minimum at rated load and at continuous operation) Total fuel consumption in liters/Kwh Rated engine power and the ambient conditions at which rated power is defined Other standard fittings of the engine to be specified by the tenderers Specific fuel consumption (in gms/kwh)

Item No.41 M/s Electro Equipments Furnished Below

FULL LOAD, AS PER IS STANDARD HA494 / KIRLOSKAR AIR COOLED SUITABLE FOR 12 HRS.

AS PER MANUFACTURER 43 BHP, AT STANDARD CONDITIONS

AS PER MANUFACTURER 163 GMS/HP-HR/ AS PER IS 10000

3.01 4 5

6

Dry weight of the DG Set with canopy Maximum continuous operating time at rated load Peak power output and the duration for which the DG set can deliver this output

1440 KG APPROX AS PER RELAVENT IS STANDARD AS APPLICABLE 10% OVERLOAD FOR 1 HR FOR EVERY 11HRS CONTINUOUS RUNNING AT RATED LOAD. Manual control panel with composite digital CLASS 1 OR AS PER SPECIFICATION, display meter, make, class & range for SUITABLE RANGE, MAKEmeasurement of voltage, current, pf, CONZERVE/SECURE/AE/L&T/INDOTECH/ frequency, kwh. HPL/ NIPPEN/ AS PER DGS&D NORMS

7

Microprocessor based AMF control panel with composite digital display meter, make, class & range for measurement of voltage,current, pf, frequency, kwh.

8

Submission of valid and renewed COP ATTACHED certificate of DG Set from an authorized certification agency. Submission of valid and renewed TAC CONFIRMED certificate of DG set from an authorized certification agency. Vibration level maximum AS PER IS:8528-9 Type of coupling and mounting details CLOSED COUPLED OR DIAPHRAGM COUPLING AS PER ENGINE MANUFACTURE

9

10 11

12 13

14 15 16

17

Deviation in the generator specification from IS specification, if any. Confirmation regarding submission of copy of type approval certificate form an authorized agency for emission norms for each model of engine quoted to D(QA) at the time of inspection. Valid BIS license no.,rating & date of validity for engine. Valid BIS license no.,rating & date of validity for alternator. Confirmation regarding COP certificate of DG Sets from an authorized agency for emission norms for each model of engine quoted, to D(QA) at the time of inspection. Make/Model/RPM of alternator

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKEUTOPIA/KIRLOSKAR/AS PER DGS&D NORMS

NIL CONFIRMED

N.A N.A CONFIRMED

TRIDENT-BRAND KIRLOSKAR GREENKG184C/DGS&D TYPE TESTED/1500

QUESTIONNAIRE DIESEL GENERATING SET WITH MANUAL CONTROL PANEL S.no 1 1.01

Item Description Diesel Generating Sets Guaranteed Technical Particulars (GTP) of DG Sets (To be furnished by tenderers for each quoted item separately)

1.02 1.03 1.04 1.05

Name of DG Set Manufacturer Electro Equipments Model number KG40AS Rated power output and duty cycle 40 KVA, CONTINUOUS Rated voltage, current, power factor and 415V, 55.6A, 0.8PF, 50HZ frequency Voltage regulation VG-1 or Better GRADE UPTO 82.5KVA AND VG-3 GRADE ABOVE 82.5 KVA Maximum temperature rise above ambient AS PER INSULATION (for engine) Class of insulation H or BETTER Efficiency of the alternator AS PER MANUFACTURER TYPE TEST CERTIFICATE Speed of revolution (RPM) at no load and 1500 RPM + 4.5% rated voltage Type of excitation and excitation voltage SELF EXCITED Ambient conditions for which the DG set is AS PER IS suitable Type of enclosure SPDP Type of loads for which the genset is suitable 0.8 POWER FACTOR (LAG)

1.06 1.07 1.08 1.09 1.1 1.11 1.12 1.13 1.14 1.15 2.01 2.02 2.03

2.04 2.05

2.06 2.07

Maximum load that can be switched on or off and voltage drop/rise permitted Engine model number & manufacturer Type of cooling Fuel tank capacity (it shall be suitable for 12 hours minimum at rated load and at continuous operation) Total fuel consumption in liters/Kwh Rated engine power and the ambient conditions at which rated power is defined Other standard fittings of the engine to be specified by the tenderers Specific fuel consumption (in gms/kwh)

Item No.43 M/s Electro Equipments Furnished Below

FULL LOAD, AS PER IS STANDARD HA494T / KIRLOSKAR AIR COOLED SUITABLE FOR MINIMUM 12 HRS.

AS PER MANUFACTURER 56 BHP, AT STANDARD CONDITIONS

AS PER MANUFACTURER 166 GMS/HP-HR/AS PER IS 10000

3.01 4 5

6

Dry weight of the DG Set with canopy Maximum continuous operating time at rated load Peak power output and the duration for which the DG set can deliver this output

1580 KG APPROX AS PER RELAVENT IS/BS STANDARD AS APPLICABLE 10% OVERLOAD FOR 1 HR FOR EVERY 11HRS CONTINUOUS RUNNING AT RATED LOAD. Manual control panel with composite digital CLASS 1 OR AS PER SPECIFICATION, display meter, make, class & range for SUITABLE RANGE, MAKEmeasurement of voltage, current, pf, CONZERVE/SECURE/AE/L&T/INDOTECH/ frequency, kwh. HPL/ NIPPEN/ AS PER DGS&D NORMS

7

Microprocessor based AMF control panel with composite digital display meter, make, class & range for measurement of voltage,current, pf, frequency, kwh.

8

Submission of valid and renewed COP ATTACHED certificate of DG Set from an authorized certification agency. Submission of valid and renewed TAC CONFIRMED certificate of DG set from an authorized certification agency. Vibration level maximum AS PER IS:8528-9 Type of coupling and mounting details CLOSED COUPLED OR DIAPHRAGM COUPLING AS PER ENGINE MANUFACTURE

9

10 11

12 13

14 15 16

17

Deviation in the generator specification from IS specification, if any. Confirmation regarding submission of copy of type approval certificate form an authorized agency for emission norms for each model of engine quoted to D(QA) at the time of inspection. Valid BIS license no.,rating & date of validity for engine. Valid BIS license no.,rating & date of validity for alternator. Confirmation regarding COP certificate of DG Sets from an authorized agency for emission norms for each model of engine quoted, to D(QA) at the time of inspection. Make/Model/RPM of alternator

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKEUTOPIA/KIRLOSKAR/AS PER DGS&D NORMS

NIL CONFIRMED

N.A N.A CONFIRMED

TRIDENT-BRAND KIRLOSKAR GREENKG184E/DGS&D TYPE TESTED/1500

QUESTIONNAIRE DIESEL GENERATING SET WITH MANUAL CONTROL PANEL S.no 1 1.01

Item Description Diesel Generating Sets Guaranteed Technical Particulars (GTP) of DG Sets (To be furnished by tenderers for each quoted item separately)

1.02 1.03 1.04 1.05

Name of DG Set Manufacturer Electro Equipments Model number KG10WS Rated power output and duty cycle 10 KVA, CONTINUOUS Rated voltage, current, power factor and 415V, 13.9A, 0.8PF, 50HZ frequency Voltage regulation VG-1 or Better GRADE UPTO 82.5KVA AND VG-3 GRADE ABOVE 82.5 KVA Maximum temperature rise above ambient AS PER INSULATION (for engine) Class of insulation H or BETTER Efficiency of the alternator AS PER MANUFACTURER TYPE TEST CERTIFICATE Speed of revolution (RPM) at no load and 1500 RPM +4.5% rated voltage Type of excitation and excitation voltage SELF EXCITED Ambient conditions for which the DG set is AS PER IS suitable Type of enclosure SPDP Type of loads for which the genset is suitable 0.8 POWER FACTOR (LAG)

1.06 1.07 1.08 1.09 1.1 1.11 1.12 1.13 1.14 1.15 2.01 2.02 2.03

2.04 2.05

2.06 2.07

Maximum load that can be switched on or off and voltage drop/rise permitted Engine model number & manufacturer Type of cooling Fuel tank capacity (it shall be suitable for 12 hours minimum at rated load and at continuous operation) Total fuel consumption in liters/Kwh Rated engine power and the ambient conditions at which rated power is defined Other standard fittings of the engine to be specified by the tenderers Specific fuel consumption (in gms/kwh)

Item No.44 M/s Electro Equipments Furnished Below

FULL LOAD, AS PER IS STANDARD EW14 / KIRLOSKAR WATER COOLED SUITABLE FOR 12 HRS.

AS PER MANUFACTURER 14 BHP, AT STANDARD CONDITIONS

AS PER MANUFACTURER 230 GMS/KW-HR/AS PER IS10000

3.01 4 5

6

Dry weight of the DG Set with canopy Maximum continuous operating time at rated load Peak power output and the duration for which the DG set can deliver this output

850 KG APPROX AS PER RELAVENT IS/BS STANDARD AS APPLICABLE 10% OVERLOAD FOR 1 HR FOR EVERY 11HRS CONTINUOUS RUNNING AT RATED LOAD. Manual control panel with composite digital CLASS 1 OR AS PER SPECIFICATION, display meter, make, class & range for SUITABLE RANGE, MAKEmeasurement of voltage, current, pf, CONZERVE/SECURE/AE/L&T/INDOTECH/ frequency, kwh. HPL/ NIPPEN/ AS PER DGS&D NORMS

7

Microprocessor based AMF control panel with composite digital display meter, make, class & range for measurement of voltage,current, pf, frequency, kwh.

8

Submission of valid and renewed COP ATTACHED certificate of DG Set from an authorized certification agency. Submission of valid and renewed TAC CONFIRMED certificate of DG set from an authorized certification agency. Vibration level maximum AS PER IS:8528-9 Type of coupling and mounting details CLOSED COUPLED OR DIAPHRAGM COUPLING AS PER ENGINE MANUFACTURE STANDARD

9

10 11

12 13

14 15 16

17

Deviation in the generator specification from IS specification, if any. Confirmation regarding submission of copy of type approval certificate form an authorized agency for emission norms for each model of engine quoted to D(QA) at the time of inspection. Valid BIS license no.,rating & date of validity for engine. Valid BIS license no.,rating & date of validity for alternator. Confirmation regarding COP certificate of DG Sets from an authorized agency for emission norms for each model of engine quoted, to D(QA) at the time of inspection. Make/Model/RPM of alternator

CLASS 1 OR AS PER SPECIFICATION, SUITABLE RANGE, MAKEUTOPIA/KIRLOSKAR/AS PER DGS&D NORMS

NIL CONFIRMED

ATTACHED ATTACHED CONFIRMED