narrative

ADDENDUM NO. ONE DATE:      FROM:      TO:      PROJECT:  September 25, 2012  Lavin Architects  Plan Holders of Record ...

0 downloads 86 Views 743KB Size
ADDENDUM NO. ONE DATE:      FROM:      TO:      PROJECT: 

September 25, 2012  Lavin Architects  Plan Holders of Record  Toot’ N Totum   2700 I‐40 West  Amarillo, Texas 79102 

  This Addendum forms a part of the Contract Documents and modifies the original Bidding Documents dated  September 4, 2012. Work not specifically deleted, modified, changed or altered by the Addendum should remain in  effect as part of the Contract Documents.  Acknowledge receipt of this Addendum in the space provided on the Bid  Form.  Failure to do so may subject Bidder to disqualification.    IN THE PROJECT MANUAL:    Section 07920        Add “Sonneborn” to list of Joint Sealant Manufacturers.      Section 15000‐2  1. a)Maximum mounting height to the top of the device is “48 inches” in lieu of “54 inches”     ON THE DRAWINGS:    Clarification ‐ Cast Stone:  No sealant at cast stone head joints on screen wall – provide tooled joints as specified.    Rake all horizontal head joints and prepare for sealant as specified (at building coping).    No sealant required at cast stone to brick joints – provide tooled joints as specified.    No sealant required at cast stone vertical applications – provide tooled joints as specified.    Architect to pick color of mortar at cast stone and brick – provide samples and mock up panels as  specified.    Sheet G1.1  See attached sheet A2 for revised Signage Mounting Detail.    Sheet C3.1  See attached for revised grading at fuel islands.    Sheet C4.2  See attached for storm sewer connection (roof drains, overflow drains, and front awnings).    Sheet C5.1  See attached for revision on joint plan.    Sheet A1.1  Detail 3, 4, 6, 7, 10, 11, 12, & 13 – all monument sign and masonry fence/pilaster grade beam  stirrups to be “#3” bars in lieu of “#5” bars.  #5 horizontal bars to remain.   

2810 Duniven Circle

Amarillo, Texas

806/358-7069

ADDENDUM NO. ONE Sheet A1.2    Sheet A2.1    Sheet A2.2    Sheet A3.1 

Site Plan Note 13 between accessible parking spaces to read “…Surface to have no slope exceeding  2% in the direction of travel…” in lieu of 5%.  All other site plan note 13 to remain.  See attached sheet A1 for revised dimensions at accessible toilet.    Corridor 103 ‐ equipment notes 31 & 39 should be switched.  39 is a sink and 31 is millwork.    Add exit signs at doors 101 & 108A.  See attached sheet A2 for sign “D”.  Sign at door 101 to be hung  right of the right hand door. 

  Sheet A3.2  See attached sheet A1 & A2 for revised details 1, 2, 3/A3.2     Sheet A6.1  See attached sheet A2 for revised detail 2/A6.1.    Sheet P0.1  See attached for revised yard hydrant locations.    Attachments:    (2) – 11x17 sheets  See Attached Civil Addendum #1  (3) – 30x42 sheets  See Attached Plumbing Addendum #1  (1) – 8‐1/2x11 sheets  (1) ‐ 11x17 Sheets      END OF ADDENDUM NO. 1     

2810 Duniven Circle

Amarillo, Texas

806/358-7069