LPV 100 LPV 100 SPEC

L P V- 1 0 0 100W Single Output Switching Power Supply series ■ Features : Constant voltage design Universal AC in...

0 downloads 189 Views 63KB Size
L P V- 1 0 0

100W Single Output Switching Power Supply

series

■ Features :

Constant voltage design Universal AC input / Full range Fully encapsulated with IP67 level (Note.8) Withstand 300VAC surge input for 5 seconds Protections: Short circuit / Overload / Over voltage Fully isolated plastic case Cooling by free air convection 100% full load burn-in test Low cost, high reliability Suitable for LED lighting and moving sign applications(Note 7.) 2 years warranty

IP67

SPECIFICATION MODEL

LPV-100-12

LPV-100-15

LPV-100-24

LPV-100-36

LPV-100-48

5V

12V

15V

24V

36V

48V

RATED CURRENT

12A

8.5A

6.7A

4.2A

2.8A

2.1A

CURRENT RANGE

0 ~ 12A

0 ~ 8.5A

0 ~ 6.7A

0 ~ 4.2A

0 ~ 2.8A

0 ~ 2.1A

RATED POWER

60W

102W

100.5W

100.8W

100.8W

100.8W

RIPPLE & NOISE (max.) Note.2 80mVp-p

120mVp-p

120mVp-p

150mVp-p

150mVp-p

150mVp-p

VOLTAGE TOLERANCE Note.3 ±8.0%

±5.0%

88%

88%

89%

41.4 ~ 48.6V

55.2 ~ 64.8V

±1.0%

LINE REGULATION

±6.0%

LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE

INPUT

50ms/230VAC Note.4 90 ~ 264VAC

127 ~ 370VDC

47 ~ 63Hz

EFFICIENCY (Typ.)

80%

AC CURRENT INRUSH CURRENT(Typ.)

2.2A/115VAC 1.2A/230VAC COLD START 75A(twidth=700μs measured at 50% Ipeak) at 230VAC

OVERLOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT

85%

87%

0.25mA / 240VAC 110 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V Protection type : Shut down o/p voltage, re-power on to recover -25 ~ +70℃ (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -40 ~ +80℃, 10 ~ 95% RH ±0.03%/℃ (0 ~ 50℃)

VIBRATION

10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes

SAFETY STANDARDS

UL8750,CSA C22.2 No 250.13-12,UL879,CSA C22.2 No.207-M89,IP67 approved. Design refer to EN60950-1

SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMC EMISSION EMC IMMUNITY MTBF DIMENSION PACKING NOTE

2000ms, 25ms / 115VAC

14ms/115VAC at full load

FREQUENCY RANGE

LEAKAGE CURRENT

OTHERS

±2.0%

Note.6 2000ms, 25ms / 230VAC

I/P-O/P:3KVAC I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH Compliance to EN55022 (CISPR22) Class B, EN61000-3-2 Class A(≤80% load), EN61000-3-3 Compliance to EN61000-4-2,3,4,5,6,8,11; EN55024, light industry level, criteria A 703Khrs min.

MIL-HDBK-217F (25℃)

190*52*37mm (L*W*H) 0.63Kg;20pcs/13.6Kg/0.55CUFT

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltage. Please check the static characteristics for more details. 5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 7. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit. 8. Suitable for indoor use or outdoor use without direct sunlight exposure.

‘

OUTPUT

LPV-100-5 DC VOLTAGE

File Name:LPV-100-SPEC 2014-08-28

L P V- 1 0 0

100W Single Output Switching Power Supply Mechanical Specification

Case No. 999A

300±20

series

Unit:mm

300±20

190

30

52

3.57

AC IN

4.5

ψ

97

T case

ψ

UL 1015 14AWG

+V(Red) -V(Black)

DC OUT

4.5

UL 1015 18AWG

AC/N(Blue) AC/L(Brown)

3.57

3.65

3.65

8

37

※ T case: Max. Case Temperature.

Recommend Mounting Direction

Block Diagram fosc : 65KHz

EMI FILTER & RECTIFIERS

I/P

RECTIFIERS & FILTER

POWER SWITCHING

O.L.P.

+V -V

DETECTION CIRCUIT

PWM CONTROL

O.V.P.

Derating Curve

Static Characteristics

100

Others

100

90 80

80

5V,12V

70

LOAD (%)

LOAD (%)

60 40

20

-25

-15

0

15

30

40

50

AMBIENT TEMPERATURE (℃)

60

70 (HORIZONTAL)

60 50 40

90

100

125

135

145

155 165

175

180

200

230

264

INPUT VOLTAGE (V) 60Hz File Name:LPV-100-SPEC 2014-08-28