ABBREVIATIONS @ #
AT POUND OR NUMBER
A.C.T.
ACOUSTICAL CEILING TILE
ADA ADD
PC
PHOTO CELL
PLAM
PLASTIC LAMINATE
FLOOR DRAIN
POLYETH
POLYETHYLENE
FE
FIRE EXTINGUISHER
TITLE SHEETS
AMERICANS WITH DISABILITIES ACT
POLYISO
POLYISOCYANURATE
FEC
FIRE EXTINGUISHER CABINET
T1.11
ADDENDUM
PRV
POWER ROOF VENTILATOR
FRP
FIBERGLASS REINFORCED PLASTIC
QT
QUARRY TILE
RA
RETURN AIR
RB
RESILIENT BASE
RD
ROOF DRAIN
REFR
REFRIGERATOR
REINF
REINFORCING / REINFORCE
REQD
REQUIRED
REV
REVISED / REVISION
RM
ROOM
RO
ROUGH OPENING
R.O.W.
RIGHT OF WAY
RTU
ROOF TOP UNIT
FRZ
FREEZER
ADJ
ADJACENT
FTG
FOOTING
AFF
ABOVE FINISH FLOOR
GA
GAUGE
AHU
AIR HANDLING UNIT
GALV
GALVANIZED
A1.11 A1.31 M2.11
GC
GENERAL CONTRACTOR
ALUM
ALUMINUM
GFCI
GROUND FAULT CIRCUIT INTERRUPT
APPROX
APPROXIMATE
GYP
GYPSUM
ARCH.
ARCHITECTURAL
HDW
HARDWARE
BD
BOARD
HM
HOLLOW METAL
BLDG
BUILDING
HORIZ HVAC
HORIZONTAL HEATING VENTILATION AND AIR CONDITIONING
ID
INSIDE DIAMETER
SA
SUPPLY AIR
IG
ISOLATED GROUND
SF
SQUARE FOOT
INFO
INFORMATION
SIM
SIMILAR
INSUL
INSULATION
SM
SURFACE MOUNTED
INT
INTERIOR
SPEC
SPECIFICATION
JAN
JANITOR
STD
STANDARD
JST
JOIST
STOR
STORAGE
CLEANOUT
LAV
LAVATORY
SUSP
SUSPENDED
CONF
CONFERENCE
LB
POUND
T&G
TONGUE AND GROOVE
CONT
CONTINUOUS
LLH
LONG LEG HORIZONTAL
T&P
TEMPERATURE AND PRESSURE
CARPET
LLV
LONG LEG VERTICAL
TEL
TELEPHONE
CERAMIC TILE
MATL
MATERIAL
TEMP
TEMPORARY
MAX
MAXIMUM
TER
TERRAZZO
MECH
MECHANICAL
T.O.
TOP OF
MEZZ
MEZZANINE
TR
TAMPER RESISTANT
MFR
MANUFACTURER
TRANSF
TRANSFORMER
MH
MANHOLE
TS
TUBE STEEL
MIN
MINIMUM
TV
TELEVISION
MISC
MISCELLANEOUS
TYP
TYPICAL
MO
MASONRY OPENING
UH
UNIT HEATER
BEARING BASEMENT
CIP
CAST IN PLACE
CJ
CONTROL JOINT
CL
CENTERLINE
CLG
CEILING
CLR
CLEAR
CMU
CONCRETE MASONRY UNIT
CO
CPT CT DEMO
DEMOLITION
DIAM
DIAMETER
DF
DRINKING FOUNTAIN
DH
DOOR HOLDER (MAGNETIC)
PROJECT MANAGER: JUSTIN STEFFL HVAC
ELECTRICAL
E2.11
ELECTRICAL PLAN
I&S GROUP 115 EAST HICKORY STREET SUITE 300 MANKATO, MN 56001 PHONE: 507-387-6651
KEY PLAN
EA
EXHAUST AIR
EF
EXHAUST FAN
EIFS
EXTERIOR INSULATION FINISH SYSTEM
ELEV
ELEVATION
MTD
MOUNTED
UNO
UNLESS NOTED OTHERWISE
ELEC
ELECTRICAL
MULL
MULLION
VCT
VINYL COMPOSITE TILE
EMERG
EMERGENCY
NA
NOT APPLICABLE
VERT
VERTICAL
ENCL
ENCLOSURE
NIC
NOT IN CONTRACT
VEST
VESTIBULE
EPDM
ETHYLENE PROPYLENE DIENE MONOMER
NTS
NOT TO SCALE
VIF
VERIFY IN FIELD
EQ
EQUAL
OC
ON CENTER
VTR
VENT THROUGH ROOF
EQUIP
EQUIPMENT
OCEW
ON CENTER EACH WAY
W/
WITH
EWC
ELECTRIC WATER COOLER
OD
OUTSIDE DIAMETER
W/O
WITHOUT
ETC
ETCETERA
OH
OVERHEAD
WC
WATER CLOSET
EXP
EXPANSION
OL
OVERALL LENGTH
WH
WALL HYDRANT
EXT
EXTERIOR
OPNG
OPENING
WHTR
WATER HEATER
FA FAAP
FRESH AIR FIRE ALARM ANNUNCIATOR PANEL
OSB
ORIENTED STRAND BOARD
WP
WEATHER PROOF (ELEC)
WWF
WELDED WIRE FABRIC
MATERIALS KEY
THIRD FLOOR DEMOLITION, FLOOR PLANS, DOOR SCHEDULE THIRD FLOOR REFLECTED CEILING PLANS, INTERIOR ELEVATIONS
MECHANICAL
ALTERNATE
BOTTOM OF
TITLE SHEET
ARCHITECTURAL
ALT
BSMT
ARCHITECT MECHANICAL ENGINEER ELECTRICAL ENGINEER
FIRE ALARM CONTROL PANEL
FD
ADDITIONAL
BRG
PROJECT CONTACT LIST
FACP
ADDL
BO
SHEET INDEX
PROJECT LOCATION MINNESOTA STATE UNIVERSITY, MANKATO MEMORIAL LIBRARY 601 MAYWOOD AVENUE MANKATO, MINNESOTA 56001
DATE
GENERAL NOTES 1.
TAGS AND SYMBOLS 2.
SECTION NUMBER SHEET NUMBER
BATT INSULATION
SECTION
1 BRICK
AX.XX
3. ELEVATION NUMBER
CONCRETE (SECTION)
1
SHEET NUMBER
AX.XX
INTERIOR / EXTERIOR ELEVATION
CMU (SECTION) 2 EARTH
1
GRANULAR FILL
3 INTERIOR ELEVATION (ALTERNATIVE) 2 A1.21
GRAVEL
DETAIL NUMBER SHEET NUMBER
GYPSUM BOARD OR SHEATHING
5.
DETAILS SHOWN ARE INTENDED TO BE INDICATIVE OF THE PROFILES AND TYPE OF DETAILING REQUIRED THROUGHOUT THE WORK. DETAILS NOT SHOWN ARE SIMILAR IN CHARACTER TO DETAILS SHOWN. WHERE SPECIFIC DIMENSIONS, DETAILS OR DESIGN INTENT CANNOT BE DETERMINED, NOTIFY ARCHITECT / ENGINEER BEFORE PROCEEDING WITH THE WORK.
6.
ALL MANUFACTURED ARTICLES, MATERIALS AND EQUIPMENT SHALL BE APPLIED, INSTALLED, CONNECTED, ERECTED, CLEANED AND CONDITIONED ACCORDING TO MANUFACTURERS' INSTRUCTIONS. IN CASE OF DISCREPANCIES BETWEEN MANUFACTURERS' INSTRUCTIONS AND THE CONTRACT DOCUMENTS, NOTIFY ARCHITECT / ENGINEER BEFORE PROCEEDING WITH THE WORK.
AREA OF DETAIL DETAIL
RIGID INSULATION
LEVEL 1 100'-0"
PLYWOOD
ELEVATION 7.
VIEW NAME
SAND
1
TITLE
1/4" = 1'-0"
STEEL
ROOM NAME ROOM NAME AND NUMBER
101
SYNTHETIC STUCCO
ONLY ONE DOOR IN A ROOM WOOD
100
100A
DOOR NUMBER
MULTIPLE DOORS IN A ROOM W1
WINDOW TYPE
1A
WALL TYPE
1 NEW CONSTRUCTION GRID
1"
2"
A
I HEREBY CERTIFY THAT THIS DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENCED ARCHITECT UNDER THE LAWS OF THE STATE OF MINNESOTA.
LARGE-SCALE, MORE SPECIFIC DETAILS TAKE PRECEDENCE OVER SMALLER-SCALE, LESS SPECIFIC DETAILS AND INFORMATION. MORE STRINGENT REQUIREMENTS FOR CODE, PRODUCTS AND INSTALLATION TAKE PRECEDENCE OVER LESS STRINGENT REQUIREMENTS. NOTIFY ARCHITECT/ENGINEER OF ANY DISCREPANCIES OR CONDITIONS REQUIRING INFORMATION OR CLARIFICATION BEFORE PROCEEDING WITH THE WORK.
PROVIDE CONTINUOUS SEALANT AROUND ALL MATERIALS AT EXTERIOR WALL PENETRATIONS. REFER TO SPECIFICATIONS FOR APPROPRIATE SEALANT. 9. ALL DISSIMILAR METALS SHALL BE EFFECTIVELY ISOLATED FROM EACH OTHER TO AVOID GALVANIC CORROSION. 10. SEAL ALL OPENINGS IN WALLS, FLOORS, CEILINGS, AND ROOFS, AROUND DUCTS, PIPES, VENTS, TRAPS, CONDUIT AND ALL OTHER PENETRATIONS WITH FIRESTOPPING AS SPECIFIED AND REQUIRED BY CODES. 11. PROVIDE TEMPORARY WALLS, ENCLOSURES, DUST SHIELDS AND WALK-OFF MATS AS REQUIRED TO SEPARATE DEMOLITION AND CONSTRUCTION FROM EXISTING BUILDING. 12. PROVIDE BRACING AND SHORING AS REQUIRED TO PROTECT EXISTING STRUCTURE TO REMAIN. PROVIDE SECURE AND WEATHERPROOF ENCLOSURE OF TEMPORARY OPENINGS IN EXTERIOR WALLS. PROTECT ALL BUILDING COMPONENTS FROM DAMAGE DURING DEMOLITION AND CONSTRUCTION.
ALYSSA F. CAMPBELL
1/21/2013
DATE
LIC. NO.
PROJECT
MINNESOTA STATE UNIVERSITY, MANKATO ITS PRIVATE OFFICES MANKATO NO
DATE
MINNESOTA REVISION SCHEDULE DESCRIPTION
8.
PROJECT NO.
12-14656
FILE NAME
14656 Arch.rvt
DRAWN BY
DMW
DESIGNED BY
AFC
REVIEWED BY
JDS
ISSUE DATE
1/21/2013
CLIENT PROJECT NO.
TITLE
TITLE SHEET
EXISTING CONSTRUCTION GRID SHEET
0 1/4" 1/2"
49026
THIS DOCUMENT IS THE PROPERTY OF I&S GROUP, INC. AND MAY NOT BE USED, COPIED OR DUPLICATED WITHOUT PRIOR WRITTEN CONSENT.
13. RESTORE ALL EXISTING AREAS AFFECTED BY DEMOLITION AND RELATED NEW CONSTRUCTION TO THEIR ORIGINAL CONDITION, INCLUDING BUT NOT LIMITED TO WALLS, FLOORS, AND CEILINGS AND THEIR ASSOCIATED FINISHES.
2 B
CONTRACT DOCUMENTS SHALL BE ISSUED TO ALL SUBCONTRACTORS BY THE GENERAL CONTRACTOR IN COMPLETE SETS IN ORDER TO ACHIEVE THE FULL EXTENT AND COMPLETE COORDINATION OF ALL WORK. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. NOTIFY ARCHITECT/ENGINEER OF ANY DISCREPANCIES OR CONDITIONS REQUIRING INFORMATION OR CLARIFICATION BEFORE PROCEEDING WITH THE WORK. FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS. NOTIFY ARCHITECT / ENGINEER OF ANY DISCREPANCIES OR CONDITIONS REQUIRING INFORMATION OR CLARIFICATION BEFORE PROCEEDING WITH THE WORK.
4
LIC. NO.
ALL WORK SHALL CONFORM TO THE CONTRACT DOCUMENTS, WHICH INCLUDE, BUT ARE NOT LIMITED TO, THE OWNER - CONTRACTOR AGREEMENT. DRAWINGS OF ALL DISCIPLINES AND ALL ADDENDA, MODIFICATIONS AND CLARIFICATIONS ISSUED BY THE ARCHITECT / ENGINEER.
4.
ELEVATION NUMBERS SHEET NUMBER
AX.XX
I HEREBY CERTIFY THAT THIS DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENCED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA.
T1.11
ISSUE DATE 01/21/2013
MANKATO, MINNESOTA
MINNESOTA STATE UNIVERSITY, MANKATO MEMORIAL LIBRARY ITS PRIVATE OFFICES I&S PROJECT NO. 12-14656
PL 02
PL 08
PL 13
PL 19
PL 02
T
PL 08
PL 13
SHEET NOTES
PL 19
T
1 T
1. OWNER TO REMOVE ALL LOOSE SHELVING, LOOSE FURNITURE AND LOOSE EQUIPMENT FROM AREA OF WORK PRIOR TO CONTRACTOR ARRIVING ON SITE.
6
T
3
5
OFFICE 3021
1
PL 01
PL 07
PL 12
PL 18
2
PL 01
3 OFFICE
1
PL 07
PL 12
PL 18
WALL LEGEND
3021
1
EXISTING CONSTRUCTION TO REMAIN
6 3
IT 32
IT 33
5
4
IT 34
IT 31
2. CONTRACTOR TO REMOVE ALL FIXED CASEWORK, FIXED FURNITURE AND FIXED EQUIPMENT IN AREA OF WORK. SALVAGE TO OWNER.
IT 32
IT 33
DEMOLITION
IT 34
NEW CONSTRUCTION
IT 31
1
KEYNOTE LEGEND 1 2 3 4 5
3 A1.11
IT 26
IT 27
IT 28
IT 29
IT 30 OFFICE 3020
IT 07
IT
IT
IT
IT
IT
26
27
28
29
30
T
IT 21
IT 22
IT 23
IT 24
6
OFFICE 3020
IT 07
REMOVE PARTITION AND SALVAGE TO OWNER. REMOVE CARPET AS INDICATED BY HATCH. REMOVE BASE. REMOVE DOOR AND SALVAGE TO OWNER. PATCH AND REPAIR WALLS AS NECESSARY TO MATCH EXISTING IN ALL RESPECTS. PATCH AND REPAIR CARPET AS NECESSARY TO MATCH EXISTING IN ALL RESPECTS.
T
IT 21
IT 25
IT
IT
35
35
IT 22
IT 23
IT 24
IT 25
SHADED REGIONS INDICATE AREAS OF WORK
T
N
A1.31 KEY PLAN
IT 17
IT 18
IT 19
IT 20
OFFICE 3019
IT 16
IT 17
IT 18
IT 19
IT 20
1
OFFICE 3019 2' - 9"
IT 15
T
IT 37
OFFICE 3016
IT 09
IT 10
IT 12
T
IT 14
IT 15
T
IT 37
STAIRWELL A IT 09
OFFICE 3016
IT 11
IT 10
STAIRWELL A
IT 11
IT 36 T
IT
IT
IT
IT
02
03
04
05
1
T 3
1
IT
IT
IT
IT
IT
01
02
03
04
05
T
6
EQ EQ
OFFICE 3021 FF-1 B-1 WF-1 P-1
5
"
OFFICE 06
3
4
A1.31
OFFICE 3018
N 6
N
CARPET TILE
--
--
COLOR
24x24
--
COMMENTS SELECTION BY OWNER
MARK
WIDTH
HEIGHT
06
3' - 0"
8' - 0"
1
302
3' - 0"
8' - 0"
1
DOOR MATERIAL 1/2" TEMPERED GLASS 1/2" TEMPERED GLASS
DOOR SCHEDULE FRAME FRAME TYPE MATERIAL
HDW GROUP
N/A
REFER TO INTERIOR ELEVATION FOR FRAME
N/A
N/A
REFER TO INTERIOR ELEVATION FOR FRAME
--
4" HIGH
--
COMMENTS SELECTION BY OWNER
WF-1
PAINT
--
--
SIZE --
PATTERN/COLOR
COMMENTS
--
REFER TO PAINT SCHEDULE
1 2"
P-1
PAINT
--
COLOR
FINISH
LOCATION
COMMENTS
--
--
--
SELECTION BY OWNER
5
2' - 6"
2'-6"
7
1/4" = 1'-0"
0 1/4" 1/2"
1"
A1.31
4
FILE NAME
14656 Arch.rvt
DRAWN BY
DMW
DESIGNED BY
AFC
REVIEWED BY
JDS
ISSUE DATE
1/21/2013
THIRD FLOOR DEMOLITION, FLOOR PLANS, DOOR SCHEDULE
FIELD VERIFY
2' - 6"
DOOR TYPES
12-14656
TITLE
PAINT LEGEND MARK MATERIAL TYPE MANUFACTURER
PROJECT NO.
CLIENT PROJECT NO.
GL-1 2' - 6"
MODEL/FINISH
6
A1.31
WALL FINISH LEGEND MARK MATERIAL TYPE MANUFACTURER
T
2' - 6"
--
COLOR
REVISION SCHEDULE DESCRIPTION
2' - 6"
OFFICE 06 FF-1 B-1 WF-1 P-1
2' - 6"
VINYL
SIZE
HOLD
B-1
SERIES/FINISH
06
DATE
MINNESOTA
COMMENTS
N/A
BASE FINISH LEGEND MARK MATERIAL TYPE MANUFACTURER
2' - 6"
EQ EQ
2' - 6"
EQ EQ
FF-1
SIZE
DOOR TYPE
1/8" = 1'-0" 3' - 0" 5 1/4"
FLOOR FINISH LEGEND
THIRD FLOOR FLOOR PLAN
NO
5 HOLD
2' - 6"
1/8" = 1'-0"
MANKATO
A1.31
2' - 6"
2
MODEL/TYPE
1/4" = 1'-0"
N
THIRD FLOOR DEMOLITION PLAN
MARK MATERIAL TYPE MANUFACTURER
ENLARGED OFFICE FLOOR PLAN
3
4 A1.11
1
2' - 0"
IT 13 T
1
OFFICE 3017
T
T
T
IT 13
OFFICE 3018
T
T
3
OFFICE 3017
12 3.5 3°
A1.31 3" 2'-
1
49026
MINNESOTA STATE UNIVERSITY, MANKATO ITS PRIVATE OFFICES
-0
3
OFFICE 3012
LIC. NO.
THIS DOCUMENT IS THE PROPERTY OF I&S GROUP, INC. AND MAY NOT BE USED, COPIED OR DUPLICATED WITHOUT PRIOR WRITTEN CONSENT.
302
3'
2
1/21/2013
PROJECT
J
OFFICE 3012
ALYSSA F. CAMPBELL
DATE
" /32 27 - 7 LD FIE RIFY VE
IT
1'
T
LIC. NO.
I HEREBY CERTIFY THAT THIS DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENCED ARCHITECT UNDER THE LAWS OF THE STATE OF MINNESOTA.
47° 146.
IT 36
01
2
A1.31
DATE
EQ EQ
IT 14
HOLD
IT 12
T
2' - 9"
T
2' - 7 3/16" 2' - 7 3/16" 2' - 7 3/16" 2' - 7 3/16" 2' - 7 3/16"
T
I HEREBY CERTIFY THAT THIS DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENCED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA.
HOLD
ENLARGED OFFICE FLOOR PLAN 1/4" = 1'-0"
N
SHEET
A1.11
ISSUE DATE 01/21/2013
IT 16
2' - 0"
FROSTED GLAZING
FROSTED GLAZING
EXISTING CONSTRUCTION TO REMAIN
FROSTED GLAZING
INTERIOR ELEVATION 1/4" = 1'-0"
GL-1
GL-1
GL-1
GL-1
GL-1
GL-1
GL-1
GL-1
GL-1
GL-1
GL-1
FROSTED GLAZING
NEW CONSTRUCTION
6' - 3"
GL-1
3' - 0"
GLAZING NOTES
2
1. FROST DENSITY SHOULD BE AS FOLLOWS: FROSTED GLAZING SHALL BE 100% ACID-ETCHED; CLEAR GLAZING SHALL BE 0% ACID-ETCHED. POLISH AND BEVELED ALL EXPOSED EDGES. SUBMIT SAMPLES FOR ARCHITECT'S REVIEW AND APPROVAL OF EACH GLAZING TYPE. INCLUDE ONE POLISHED AND BEVELED EDGE ON EACH SAMPLE SUBMITTED.
INTERIOR ELEVATION
3
1/4" = 1'-0"
INTERIOR ELEVATION 1/4" = 1'-0"
4
INTERIOR ELEVATION
5
1/4" = 1'-0"
INTERIOR ELEVATION
GLAZING LEGEND
1/4" = 1'-0"
MARK MATERIAL TYPE MANUFACTURER GL-1
CLEAR GLAZING
GL-1
GL-1
GL-1
GL-1
MARK MATERIAL TYPE MANUFACTURER
GL-1
GL-1
GL-1
FINISH
COMMENTS
-
VARIES
VARIES
SEE ELEVATIONS FOR FINISHES
CEILING FINISH LEGEND C-1
GL-1
SIZE
-
FROSTED GLAZING
FROSTED GLAZING
GL-1
1/2" TEMPERED GLASS
MODEL
ACOUSTICAL CEILING TILE
ARMSTRONG
MODEL
SIZE
FINISH
COMMENTS
CIRRUS
24" X 24"
TEGULAR
9/16" GRID
GL-1
LIGHT FIXTURE REFER TO ELECTICAL DOCUMENTS - TYP.
DIFFUSER REFER TO MECHANICAL DOCUMENTS-TYP
SHADED REGIONS INDICATE AREAS OF WORK NEW BULKHEAD 8'-0" AFF; CENTER ABOVE GLAZING SYSTEM; TYPICAL
DIFFUSER REFER TO MECHANICAL DOCUMENTS-TYP.
6
INTERIOR ELEVATION 1/4" = 1'-0"
7
LIGHT FIXTURE REFER TO ELECTICAL DOCUMENTS - TYP.
INTERIOR ELEVATION
KEY PLAN I HEREBY CERTIFY THAT THIS DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENCED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA.
DIFFUSER REFER TO MECHANICAL DOCUMENTS - TYP
1/4" = 1'-0"
DATE
OFFICE 3021 8
OFFICE 3021
A1.31
TYPICAL
I HEREBY CERTIFY THAT THIS DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENCED ARCHITECT UNDER THE LAWS OF THE STATE OF MINNESOTA.
C-1 9' - 4"
ALYSSA F. CAMPBELL
DATE
EXTEND GYPSUM BOARD TO DECK ABOVE
THIS DOCUMENT IS THE PROPERTY OF I&S GROUP, INC. AND MAY NOT BE USED, COPIED OR DUPLICATED WITHOUT PRIOR WRITTEN CONSENT.
A.C.T., GRID, AND LIGTING TO REMAIN
A.C.T 109'-4" REMOVED AND SALVAGED A.C.T
C-1
10
REMOVE AND SALVAGE A.C.T. AND GRID
REMOVE 12" X12" A.C.T., GRID, AND LIGHTING, REFER TO ELECTRICAL DOCUMENTS
REINSTALL SALVAGED A.C.T AND GRID; MODIFY AS NECESSARY TO MATCH EXISTING IN ALL RESPECTS
A.C.T. AND GRID TO REMAIN
PARTIAL DEMOLITION REFLECTED CEILING PLAN 1/4" = 1'-0"
NEW BULKHEAD 8'-0" AFF, CENTER ABOVE GLAZING SYSTEM; TYPICAL
A.C.T., GRID, AND LIGHTING TO REMAIN
5 1/2" FIBERGLASS INSULATION IN EACH STUD SPACE
REMOVE AND SALVAGE A.C.T AND GRID OFFICE
LIGHT FIXTURE REFER TO ELECTRICAL DOCUMENTS -TYP.
MANKATO DATE
MINNESOTA REVISION SCHEDULE DESCRIPTION
OFFICE 06
06
5/8" TYPE X GYPSUM BOARD EQ.
LIGHT FIXTURE REFER TO ELECTRICAL DOCUMENTS TYP.
C-1 9' - 4"
A.C.T. AND GRID TO REMAIN 8 A1.31
8
49026
MINNESOTA STATE UNIVERSITY, MANKATO ITS PRIVATE OFFICES
1/4" = 1'-0" LIGHT FIXTURE REFER TO ELECTICAL DOCUMENTS -TYP.
LIC. NO.
PROJECT
NO
3 5/8" STEEL STUD @ 16" OC TO DECK ABOVE
1/21/2013
PARTIAL REFLECTED CEILING PLAN
11
DIFFUSER REFER TO MECHANICAL DOCUMENTS - TYP.
EQ.
LIC. NO.
1/4" X 1 3/4" TAPCON SCREW INTO CONCRETE DECK @ 16" O.C.
3 5/8" STUD BRACING @ 48" O.C.
BOTTOM OF BULKHEAD 108'-0" 1 1/2” DEEP U CHANNEL; ANODIZED ALUMINUM GLAZING GASKET 1/2" TEMPERED GLASS
TYPICAL
GLAZING DETAIL IT 06
3" = 1'-0"
PROJECT NO.
12-14656
FILE NAME
14656 Arch.rvt
DRAWN BY
DMW
DESIGNED BY
AFC
REVIEWED BY
JDS
ISSUE DATE
1/21/2013
CLIENT PROJECT NO.
TITLE
2"
1/2" TEMPERED GLASS
GLAZING GASKET
PLASTIC CHANNEL GLASS SETTING BLOCKS
1" 0 1/4" 1/2"
A.C.T., GRID, AND LIGHTING TO REMAIN
1 1/2” DEEP U CHANNEL ANODIZED ALUMINUM FLOOR 100'-0"
DIFFUSER REFER TO MECHANICAL DOCUMENTS TYP.
REMOVE 12"X 12" A.C.T., GRID, AND LIGHTING, REFER TO ELECTRICAL DOCUMENTS
REINSTALL SALVAGED A.C.T. AND GRID; MODIFY AS NECESSARY TO MATCH EXISTING IN ALL RESPECTS
THIRD FLOOR REFLECTED CEILING PLANS, INTERIOR ELEVATIONS
SHEET
9
N
GLAZING DETAIL 6" = 1'-0"
12
PARTIAL DEMOLITION REFLECTED CEILING PLAN 1/4" = 1'-0"
13
PARTIAL REFLECTED CEILING PLAN 1/4" = 1'-0"
A1.31
ISSUE DATE 01/21/2013
1
1' - 6"
TOP AND BOTTOM CHANNEL WITH END CAPS, TYPICAL UNO
TYPICAL DIMENSIONS
GL-1
WALL LEGEND
CLEAR GLAZING
DEMOLITION 3" 3" 1' - 6" 6" 6" 3' - 3"
GL-1
4' - 9"
FROSTED GLAZING
TYPICAL DIMENSIONS
2' - 0"
CLEAR GLAZING
KEYNOTE LEGEND 1 2 10
DEMO EXISTING DIFFUSERS AND FLEX DUCT SALVAGE EXISTING RETURN GRILLES AND DUCT DUCTWORK TO GO THROUGH WALL INTO INTERSTITIAL SPACE
10
B RA 24/8
A 100
1
2
1
A 100
12/12
B RA
SHADED REGIONS INDICATE AREAS OF WORK
North 2.01 Demo Third Floor HVAC 1/4" = 1'-0"
2
North 3.01 New Third Floor HVAC KEY PLAN
1/4" = 1'-0"
I HEREBY CERTIFY THAT THIS DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA.
2
ANTHONY J. EFFENBERGER
1
1-21-13
DATE T
13/7
13/7
25/7
M
ACTUATOR
DIFFUSER
TIE-IN A 125
B RA
A 125
DUCT COIL
BACKDRAFT DAMPER
DUCT WORK (UNLINED)
FLEXIBLE DUCT
DUCT WORK (LINED)
T P PNUEMATIC THERMOSTAT
HUMIDISTAT
CUH-
CO DETECTOR
CO 2
DC-
ENERGY RECOVERY VENTILATOR HEATING VENTILLATION AIR CONDITIONING UNIT
DATE
LIC. NO.
THIS DOCUMENT IS THE PROPERTY OF I&S GROUP, INC. AND MAY NOT BE USED, COPIED OR DUPLICATED WITHOUT PRIOR WRITTEN CONSENT.
LOUVER POWER ROOF VENTILATOR PUMP ROOF TOP UNIT TRANSFER AIR GRILLE
UH-
UNIT HEATER
AIR COOLED CONDENSING UNIT AIR HANDLING UNIT
XX"xXX"Ø
CABINET UNIT HEATER
XX"xXX"
DUST COLLECTOR X"Ø
FIRE DAMPER
T
T
F
EXHAUST FAN
TG-
A.F.F. AHU-
SMOKE SENSOR
S
RTU-
NEW MECHANICAL EQUIPMENT CU-
41935
PROJECT
NEW MECHANICAL DUCTWORK
DUCT SMOKE DETECTOR
H
PRV-
DUCT WORK (DOUBLE WALL / PERFORATED INNER)
D 10
L-
P-
ELECTRIC THERMOSTAT
S 1
HVAC-
T S TEMPERATURE SENSOR
24/8
ERV-
EXHAUST OR RETURN GRILLE
MANUAL AIR BALANCING DAMPER
T
B RA
EF-
MANUAL OPPOSED BLADE DAMPER
LIC. NO.
I HEREBY CERTIFY THAT THIS DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED ARCHITECT UNDER THE LAWS OF THE STATE OF MINNESOTA.
T
MECHANICAL HVAC SYMBOL SCHEDULE 25/7
ABOVE FINISHED FLOOR
MSU ITS PRIVATE OFFICES
FLAT OVAL DUCT RECTANGULAR DUCT ROUND DUCT
MANKATO FLEX DUCT (7'-0" MAX. LENGTH OF ONE BRANCH
SUPPLY AIR DUCT DOWN
GALVANIZED STEEL ELBOW AT DIFFUSER CONNECTION
NO
DATE
MN REVISION SCHEDULE DESCRIPTION
GALVANIZED STEEL ELBOW
3
South 2.01 Demo Third Floor HVAC
4
1/4" = 1'-0"
South 3.01 New Third Floor HVAC
F/S
FIRE/SMOKE DAMPER
S
SMOKE DAMPER
1/4" = 1'-0"
DIFFUSER EXISTING DUCTWORK TO REMAIN
C
F
FIRE DAMPER
D
MANUAL DAMPER
G
GRAVITY BACKDRAFT DAMPER
M
MOTORIZED DAMPER
ROUND SPIN-IN TAKE-OFF
CEILING RADIATION DAMPER
DUCTWORK TO BE REMOVED PROJECT NO.
24/12
MITERED ELBOWS TURNING VANES
DUCT SIZE IN FREE AREA 45 DEGREE SHOE-TAP TAKE-OFF
VOLUME DAMPER (TYP.)
2" 1" 0 1/4" 1/2"
MFG
A B
PRICE INDUSTRIES PRICE INDUSTRIES
DIFFUSER, REGISTER AND GRILLE SCHEDULE MODEL # REMARKS 8" / 24" x 24" / SCD / 31 / 3C / B12 EXISTING
SQUARE CONE DIFFUSER EXISTING
"R
TYPICAL FLEXIBLE DUCT CONNECTION (BEFORE AND AFTER EQUIPMENT) EXHAUST OR REUTRN AIR INLET
DRAWN BY
TJI
DESIGNED BY
AJE
REVIEWED BY
AJE
ISSUE DATE
1-21-13
CLIENT PROJECT NO.
TITLE
NOTE: "R" SHALL BE 1.5 TIME DUCT WIDTH
RETURN AIR DUCT DOWN
12-14656
FILE NAME
SUPPLY AIR DUCT UP
NOTE: DUCT SIZE; FIRST NUMBER INDICATES DIMENSION OF SIDE SHOWN. THE SECOND NUMBER INDICATES SIDE NOT SHOWN
MARK
N
EXHAUST OR RETURN AIR GRILLE
TYPICAL HVAC SYMBOLS AND DETAILS
HVAC
"
EXHAUST OR RETURN AIR DUCT UP
NOTE: THIS DRAWING IS FOR INFORMATIONAL PURPOSES ONLY. ITEMS SHOWN ARE NOT NECESSARILY USED ON THIS PROJECT.
N SHEET
M2.11
ISSUE DATE 01/21/2013
1
12/12
2
X
KEY
1
X
1 2 3 4
X
X
X
X
XD 1
A
1
2
5
X
X
8 9
XD A
10
XD
10
X
XD
X
9
XD
OS
ELECTRICAL KEYNOTE LEGEND KEYNOTE TEXT ALL DEVICES NOTATED WITH AN 'X' ARE EXISTING AND ARE TO REMAIN. TYPICAL LIGHT FIXTURE TO BE DEMOLISHED. DUAL CHANNEL SURFACE RACEWAY TO REMAIN ON THIS WALL. DISCONNECT POWERED CUBICLE WALLS FROM SURFACE RACEWAY. PROVIDE BLANK PLATE OVER OPENING IN RACEWAY. EXISTING LIGHT FIXTURES TO BE REMOVED FOR CONSTRUCTION OF NEW OFFICE AND REINSTALLED IN SAME LOCATION. PROVIDE NEW LIGHT SWITCH, CONCEAL IN WALL IF POSSIBLE. CEILING MOUNTED OCCUPANCY SENSOR. SENSOR TO BE LEVITON #ODC05-MDW OR EQUAL. CONTRACTOR TO CONNECT LIGHT FIXTURES TO THE NEAREST 277V CIRCUIT. CONTRACTOR MAY UTILIZE EXISTING LIGHT CIRCUIT BUT CONNECTION TO BE MADE ON THE LINE SIDE OF LIGHTING CONTACTOR WHICH WAS CONTROLLING THE LIGHTS. EXISTING PANEL IS LOCATED APPROXIMATELY 165 FEET AWAY. FIELD VERIFY CONDITIONS.
A
XD 8
X
X
XD
SHADED REGIONS INDICATE AREAS OF WORK
PARTIAL ELECTRICAL DEMOLITION PLAN NORTH
1
1/4" = 1'-0"
KEY PLAN
PARTIAL ELECTRICAL PLAN NORTH
3
N
I HEREBY CERTIFY THAT THIS DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA.
1/4" = 1'-0"
MICHAEL D. NELSON
XR
XD
5
8
I HEREBY CERTIFY THAT THIS DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED ARCHITECT UNDER THE LAWS OF THE STATE OF MINNESOTA.
1 X
XR
47560
LIC. NO.
5 X A
X
XR
XD XD
J
10
DATE
4
2
XR
X
XD
THIS DOCUMENT IS THE PROPERTY OF I&S GROUP, INC. AND MAY NOT BE USED, COPIED OR DUPLICATED WITHOUT PRIOR WRITTEN CONSENT.
3 9
OS
XR
XD
LIC. NO.
A
PROJECT
3 1
MINNESOTA STATE UNIVERSITY, MANKATO ITS PRIVATE OFFICES
XR XD
X
A
X
XR
XD
XR 1 1
TYPE DESCRIPTION MANUFACTURER A X XD XR
2-LAMP TROFFER -
WILLIAMS -
X
LIGHT FIXTURE SCHEDULE MODEL LAMP 50G-S24-232-SA12125-EB2-277 --
2-F32T835K -
X
X
X
X
MANKATO
X
TYPE COMMENTS NO EXISTING FIXTURE TO REMAIN EXISTING FIXTURE TO BE DEMOLISHED EXISTING FIXTURE TO BE REMOVED AND REINSTALLED
DATE
MINNESOTA REVISION SCHEDULE DESCRIPTION
N 2
PARTIAL ELECTRICAL DEMOLITION PLAN SOUTH
4
1/4" = 1'-0"
PARTIAL ELECTRICAL PLAN SOUTH 1/4" = 1'-0"
ELECTRICAL SYMBOLS LEGEND RECEPTACLES
SWITCHES
SIMPLEX
SINGLE POLE
DISCONNECT
FACP
FIRE ALARM CONTROL PANEL
FAN
FAAP
FIRE ALARM ANNUNICATOR PNL
N
DOME LIGHT
S
SMOKE DETECTOR
ND
DUTY STATION
ELECTRICAL CONTROLED VALVE
S
SMOKE DETECTOR 120V
Z
NCP
IG
ISOLATED GROUND
3
3-WAY
TR
TAMPER RESISTANT
4
4-WAY
WP
WEATHER PROOF W/GFI
E
EMERGENCY
F
FUSESTAT
H
HEAT DETECTOR
SS
ZONE LIGHT STAFF STATION
GFI
GROUND FAULT INTERRUPT
F
FAN
D
HAND DRYER
F
HORN STROBE
N
NURSE/TOILET STATION
CTR
COUNTERTOP RECEPTACLE
K
KEY OPERATED
H
HAIR DRYER
HIGH VOLTAGE
LV
LOW VOLTAGE
H
HEATER
SPLIT WIRE
P
PILOT LIGHT
J
JUNCTION BOX
T
TIMER
MOTOR
CIRCUIT BREAKER
MOTOR WITH DISCONNECT
M
MINI HORN
RELAY
A
ANSUL TIE
SOLENOID VALVE
TS
SPRINKLER TAMPER SWITCH
FS
SPRINKLER FLOW SWITCH
CB
SPECIAL PURPOSE
D
DIMMER
CEILING MOUNTED RECPT
H
ILLUMINATED HANDLE
M
MOTOR
SC
SPEED CONTROLLER
W
SPRING WOUND TIMER
MC
MOMENTARY CONTACT
WP
R
T
S F
COMBINATION STARTER & DISC
WS F
MOTOR STARTER
CS F
THERMOSTAT
WEATHER PROOF
SD OS OCCUPANCY SENSOR-WALL OCCUPANCY SENSOR-CEILING OS PHOTO CELL PC 3-BUTTON SWITCH
HORN ONLY
DATA JACK C
SECURITY DAA
TELEPHONE JACK TV
TELEVISION JACK
S
SPEAKER - CEILING
CAMERA CR
CARD READER - ELECTRONIC
SEC
DOOR SECURITY MONITOR
K
KEY CARD PAD
P
STROBE ONLY SPEAKER STROBE
S
SPEAKER - WALL
C
CLOCK
R
EXTERIOR HORN WITH STROBE
B
BELL
DL
WALL SPEAKER - FIRE
BUZZER I M
DOOR ALARM ANNUNICATOR ADA DOOR OPERATOR
FLOOR DATA JACK DATA/VOICE JACK
ELECTRICAL PANELS
PUSH BUTTON
P1 P1 PHONE
FLUSH MOUNT PANELBOARD SURFACE MOUNT PANELBOARD PHONE SYSTEM
PROJECT NO.
12-14656
FILE NAME
14656 ELECTRICAL.RVT
DRAWN BY
MDN
DESIGNED BY
MDN
REVIEWED BY
CWR
ISSUE DATE
01/21/2013
CLIENT PROJECT NO.
AREA OF RESCUE-REMOTE CALL ELECTRIC LOCK
TITLE
SECURITY ALARM HORN
INTERCOM MICROPHONE
ELECTRICAL PLAN
SPEAKER/CLOCK TC
TIME CLOCK
CEILING SPEAKER - FIRE MAGNETIC DOOR HOLDER MANUAL PULL STATION
F
DUCT-TYPE SMOKE DETECTOR
COMMUNICATIONS
NURSE CONTROL PANEL
DOUBLE POLE
FLOOR BOX RECEPTACLE
2"
NURSE CALL SYSTEM
2
220 VOLT
1"
FIRE PROTECTION SYSTEM
DUPLEX
QUADRUPLEX
0 1/4" 1/2"
MISC. POWER SYMBOLS
AIM AOM
ADDRESSABLE INPUT MODULE ADDRESSABLE OUTPUT MODULE ABORT SWITCH
C EOLD
BELL-CHIME END OF LINE RESISTOR
SHEET
E2.11
ISSUE DATE 01/21/2013
01/21/2013
DATE