Precision flow solutions
an ISO 9001:2008 certified company
Model G015 Gear Flow Meter (Frequency) 0.15 to 15 liters/min SPECIFICATIONS Flow Range 0.15 to 15 liters/min. Maximum Operating Pressure 414 bar (6000 psi) Displacement 4.2 cc/rev Weight 1.8 kg Recommended Filtration 15 micron Port Size(s) 3/8" NPT or #6 SAE Accuracy (at 30 cP) ± 0.3% of reading over a 100:1 turndown (30 cP) Fluids Most non-aqueous, hydrocarbon based fluids
MATERIALS OF CONSTRUCTION Body Stainless steel, type 303 Gears and Shafts Stainless steel, type 17-4 Bearings All ball bearings, 440C stainless steel Seals Viton®- standard, Teflon®, Perfluoro elastomer FREQUENCY TRANSMITTER Output Signal Output Resolution Min-max frequency Power Supply Requirements Ambient Operational Range Metered Liquid Temp Range
5 Vdc square wave (TTL and CMOS compatible) Selectable: 1-1000 pulses/rev (2 - 235 pulses/cc) 0 - 60 Khz 5 - 26 Vdc, @ 30 mA -40°C to 80°C -40°C to 90°C, standard model
(Based on 20° ambient, using 5v power)
-40°C to 155°C, high temperature model -40°C to 218°C, ultra high temperature model CE Certified
Compliance CONNECTIVITY/DIMENSIONS 4
3 5
Turck® Connector Mating Cable Wire Color
Pin #
Case Ground
Blue
3
Common
Black
4
Power (+5-26Vdc)
Brown
1
Pulse Output
White
2
1
N/A
2
Grey
5
1.36"
(35 mm)
2.6"
(66 mm)
3.0"
(97 mm)
2.0"
(63 mm)
1/4" - 20NC mounting (4) on bottom
0.5" 1.75"
(57 mm)
3/8" NPT 3.25"
(102 mm)
G015-000-300 • 8/2010 • ©2007-10 Max Machinery, Inc.
`
(16 mm)
Model G015 Flow Meter ACCURACY (Sample Curves)
1.5
1.0
% Error
-0.5
100:1 +0.3%
100 cP fluid 0.0
30 cP fluid -0.5
-0.3%
-1.0
-1.5
0.01
0.1
1
10
100
10
100
Flow Rate (liters/min)
TYPICAL PRESSURE DROP Expected Failure Area 140
Intermittent Duty Area
100 80 — 6 bar
60
— 4 bar
10 00 cP
— 8 bar
10,0 00 cP
Pressure Drop (psi)
120
Continuous Duty Area
40 — — 2 bar 20
cP 100 30 cP 2 cP
0.01
0.1
1
Flow Rate (liters/min)
Max Machinery, Inc. maxmachinery.com
33A Healdsburg Avenue
T + 1 707.433.2662
Healdsburg, CA 95448
F + 1 707.433. 1 8 1 8