dab DP

® DP FOR DEEP SUCTION DP 81-100 DP 151-251 Operating range: from 0.15 to 4.3 m3/h Liquid temperature range: from 0°C...

0 downloads 102 Views 131KB Size
®

DP FOR DEEP SUCTION

DP 81-100

DP 151-251

Operating range: from 0.15 to 4.3 m3/h Liquid temperature range: from 0°C to +40°C for other uses from 0°C to +35° C for domestic use Pumped liquid characteristics: clean, free from solids or abrasive substances, not viscous, not aggressive, not crystallised and chemically neutral. Maximum ambient temperature: +40°C Maximum working pressure: 6 bar (600 kPa) for DP 80 - DP 100 8 bar (800 kPa) for DP 151 - DP 251 Protection level: IP 44 Insulation class: F

Self-priming centrifugal pump for suction up to 27 metres , reached by means of an ejector. Cast iron pump body and motor support. Technopolymer impeller and diffusers. Stainless steel adjustment rings. Carbon/ceramic mechanical seal. Cast iron ejector body, technopolymer Venturi tube and brass nozzle. Asynchronous motor closed and cooled by external ventilation. Built-in thermal and current overload protection and a capacitor permanently on in the single-phase version. For the protection of the three-phase motor it is advisable to use a suitable overload protection complying with the regulations in force.

ELECTRICAL DATA

ELECTRICAL DATA VOLTAGE 50 Hz

P1 MAX kW

P2 NOMINAL kW HP

1x220-240 V ~ 3x230-400 V ~ 1x220-240 V ~ 3x230-400 V ~ 1x220-240 V ~ 3x230-400 V ~ 1x220-240 V ~ 3x230-400 V ~

0,69 0,66 0,79 0,64 1,56 1,45 – –

0,44 0,44 0,75 0,75 1,1 1,1 1,85 1,85

MODEL

DP 81 M DP 81 T DP 100 M DP 100 T DP 151 M DP 151 T DP 251 M DP 251 T

Performance range

0,6 0,6 1 1 1,5 1,5 2,5 2,5

In A

CAPACITOR µF

Vc

3,2 2,,6-1,5 3,8 2,6-1,5 7 4,7-2,7 8,3 5,6-3,2

12,5 – 16 – 31,5 – 40 –

450 – 450 – 450 – 450 –

HYDRAULIC DATA (n ∼ 2800 r.p.m.) PUMP TYPE

EJECTOR TYPE

1,5

2

2,5

3

9 12 15 9 12 15

2140 1730 1220 1790 1500 1260

1410 1000 580 1340 1100 880

730 400 – 950 740 570

– – – 620 460 320

360 250 –

– – –

E 25

9 12 15

2580 1990 1400

1870 1400 950

1120 720 380

470 – –

– – –

E 30

12 15 18 21

1770 1500 1260 –

1350 1120 910 720

980 775 600 450

650 500 350 250

E 20

9 12 15 18

– – – –

– – – –

– – – –

E 25

15 18 21

– – –

– – –

E 30

21 24 27

– – –

E 20

9 12 15 18

E 25

E 30

E 25

DP 81 E 30

DP 100

DP 151

DP 251

Delivery pressure in bar 4 4,5 Capacity table in l/h – – – – – – – – –

SUCTION DEPTH

3,5

5

5,5

6

6,5

7

– – –

– – –

– – –

– – –

– – –

– – –

– – –

– – –

– – –

– – –

– – –

– – –

– – –

– – –

– – –

– – –

– – –

– – –

400 280 150 –

– – – –

– – – –

– – – –

– – – –

– – – –

– – – –

– – – –

3470 3110 2710 2360

2890 2510 2100 1700

2220 1850 1380 950

1500 1100 640 –

750 300 – –

– – – –

– – – –

– – – –

– – – –

– – –

2800 2530 2280

2330 2050 1800

1830 1550 1300

1350 1090 860

900 680 470

520 300 –

– – –

– – –

– – –

– – –

– – –

1820 1680 1550

1650 1520 1360

1410 1260 1110

1160 1020 880

910 780 680

700 580 490

520 420 330

– – –

– – –

– – – –

– – – –

– – – –

4300 3750 – –

3600 3140 2780 2340

2900 2540 2040 1610

2180 1700 1300 820

1400 940 500 –

640 – – –

– – – –

– – – –

– – – –

15 18 21 24

– – – –

– – – –

– – – –

– – – –

2920 2600 2350 2050

2400 2110 1850 1550

1900 1620 1350 1080

1400 1150 900 660

950 720 510 300

570 360 – –

– – – –

– – – –

21 24 27

– – –

– – –

– – –

– – –

– – –

1710 1580 1440

1480 1330 1200

1220 1080 950

980 850 750

770 670 560

590 490 400

420 330 250

®

DIMENSIONS AND WEIGHTS DP 81-100

MODEL

DP 81

DP 151-251 Convertible

EJECTOR H1 x

A

B

C

E

G



H

H1

H2

DNA

DNM

DNE

385

180

90

202

140

9,5

225

47

92

1 1/4” G

1” G

1” G

1” G

1” G

97

295

143

1” G

1” G

97

295

143

A

H

97

295

143

y

z

WEIGHT Kg

1” G

1 1/4” G

13

1” G

1” G

1 1/4” G

15,7

1” G

1” G

1 1/4” G

28 32,5 27,9

1” G

DP 100

385

180

90

202

140

9,5

225

47

92

1 1/4” G

DP 151

388

210

50

197

145

11

155

52

108

1 1/4” G

1” G

1” G

97

295

143

1” G

1” G

1 1/4” G

1” G

1” G

97

295

143

1” G

1” G

1 1/4” G

DP 251 M

462

210

50

197

145

11

155

53

108

1 1/4” G

DP 251 T

388

210

50

197

145

11

155

53

108

1 1/4” G

INSTRUCTION FOR CONVERSION

Conversion from DP 151-251 to JET 151-251 Screw the nozzle (9) into place on the ejector’s body (2) and the Venturi tube (8). Put the O-rings (27) and (29) in their respective places and fix the ejector body (2) to the pump body (1) using the two screws (62).

Conversion from JET 151-251 to DP 151-251 Loosen and remove the two screws (62) connecting the ejector body (2) to the pump body (1). Save the O-rings (27) and (29), the Venturi tube (8) and the nozzle (9).