COPS RSDB
NRNAC101
ROSINA HK monitoring PDS Keyword
HK-Mnemonic Description old
COPS Std. HK Header Range Status ROSINA_COPS_COMMAND_ERR Command COPS command Error OR_FLAG Error Spare ROSINA_COPS_FIL_ION_R_FLAG Filament Ion Config of the Range electrometer for the Ion current in Nude Gauge
HK Type
Flag
1, 18.10.2006, K.A.
Std./Ex Monitoring if Sampl Transmi Range ssion t. Pack. ing frequ frequen ency cy S/C
Std.
Flag
Measurement
2s
1min
On / Off
Measurement 2s with Nude Gauge
1min
Low / Medium / High
Criti- Action, calit if outside y range
TBD 4 no action
Std. ROSINA_COPS_MIC_ION_R_FLA Microtip Ion G Range
Config of the electrometer for the Ion current in Ram Gauge
Flag
ROSINA_COPS_FIL_EMISSION_R Filament _FLAG Imission Range
Config for the Immision current measurement in Nude Gauge
Flag
Config for the Immision current measurement in Ram Gauge
Flag
Measurement with Ram Gauge Std.
ROSINA_COPS_MIC_EMISSION_ Microtip R_FLAG Imission Range NRNAC102 ROSINA_COPS_HK_COUNTER
COPS HK counter
Housekeeping counter Command counter
Std.
Command error counter
Std.
COPS Cmd Error position COPS HK Error counter
1min
Low / High
4 no action
2s
1min
Low / High
4 no action
2s
1min
not applicable TBD
2s
1min
not applicable TBD
2s
1min
not applicable TBD
2s
1min
not applicable TBD
4 no action
Measurement
counter
Measurement
counter
Measurement
counter Std.
NRNAC105 ROSINA_COPS_CMD_ERROR_P OSITION NRNAC106 ROSINA_COPS_HK_ERROR_COU NTER
2s Measurement with Ram Gauge
Std. NRNAC104 ROSINA_COPS_CMD_ERROR_C COPS Cmd OUNTER Error counter
1min
Measurement with Nude Gauge
Std. NRNAC103 ROSINA_COPS_CMD_COUNTER COPS Cmd counter
2s
Low / Medium / High
Housekeeping errors counter counter
Measurement Std.
Remarks Used for regulati on
COPS RSDB
ROSINA HK monitoring PDS Keyword
NRNAC107 ROSINA_COPS_MODE
HK-Mnemonic Description old
NRNAC109 ROSINA_COPS_PRESSURE_NG
COPS S/W mode COPS S/W status Pressure NG
NRNAC10A ROSINA_COPS_PRESSURE_RG
Pressure RG
NRNAC108 ROSINA_COPS_STATUS
HK Type
Std./Ex Monitoring if Sampl Transmi Range ssion t. Pack. ing frequ frequen ency cy S/C
Pressure in the Nude Calculat Gauge ed Std. Pressure in the Ram Calculat Gauge ed Std.
NRNAC10B ROSINA_COPS_CALIB_FAC_OFF Calibration SET_NG factor NG
NRNAC10C ROSINA_COPS_CALIB_FAC_OFF Calibration SET_RG factor RG
NRNAC10D
Value entering in the calculation of the Nude Gauge pressure
Fixed value
Value entering in the calculation of the Ram Gauge pressure
Fixed value
Active Filament or/and Filament/Microt Microtips activated ips Spare
2, 18.10.2006, K.A.
Std.
Std. Flag Std.
Measurement with Nude Gauge 2s Measurement with Ram Gauge 2s Measurement with Nude Gauge 2s Measurement with Ram Gauge 2s Measurement 2s
Criti- Action, calit if outside y range
1min